A CASE REPORT OF CORRECTION OF MANDIBULAR PROGNATHISM BY INTRAORAL OBLIQUE SPLITTING OSTEOTOMY OF MANDIBULAR RAMI (구내 경사 분열 골절단술(Intraoral oblique splitting osteotomy)에 의한 하악 전돌증의 치험례)

  • Park, Hui-Dae;Doe, Kee-Yong;Bae, Yun-Ho;Byun, Sang-Kill;Chin, Byung-Rho;Lee, Hee-Keung
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.183-194
    • /
    • 1989
  • This is a report of 2-cases of mandibular prognathism corrected by Intraoral oblique splitting osteotomy of mandibular ramus. The Intraoral oblique splitting osteotomy is a modification of sagittal split osteotomy of ramus and it is documented by Yoshida, on 1985. By this method. authors obtained the following results. 1. The patients' esthetic, psychological and functional problems were dissolved by setback of mandibular prognathism. 2. The postoperative infection, splitted bone segments fracture, paresthesia of the face and T.M.J. dysfunction were not appeared. 3. Postoperative intermaxillary fixation was maintained for 8 weeks. The patients could open their mouths in normal range after a week of intermaxillary fixation removal. 4. The soft tissue changes of lower lip and chin were about 1:1 to the hard tissue changes. 5. During intermaxillary fixation period and postoperative orthodontic treatment, slight relapse was observed. Now, the patients are under postoperative orthodontic treatment.

  • PDF

The Relationship between Food Habit, Nutrient Intakes and Bone Mineral Density and Bone Mineral Content in Adult Women (성인여성의 식습관과 영양섭취상태와 골밀도 및 골무기질함량과의 관계)

  • 최미자;정윤정
    • Journal of Nutrition and Health
    • /
    • v.31 no.9
    • /
    • pp.1446-1456
    • /
    • 1998
  • Bones are important parts in sustaining the shape of the body, but they are also metabolic organs which undergo bone remodeling by constant bone resorption and formation. Osteoporosis, the typical metabolic bone disease, is characterized by a reduction in bone mineral density (BMD). Women more than men are at risk fir osteoporosis-related fractures, especially in the lumbar spine, wrist, and hip region. Risk of fracture depends on one's BMD, which open determined by the peak bone mass value achieved at skeletal maturity and followed by subsequent age-and menopause-related bone loss. Genetic and environmental factors are known to play a key role in bone metabolism and diet is considered as one of the important environmental factors. The purpose of the present study was to assess the status of BMD and bone mineral content(BMC) to clarify the relationships between dietary intakes and the risk of osteoporosis in adult women in Taegu. Subjects were 130 healthy females in between 20 and 69 years of age. BMD and BMC of the lumbar spine(venebrae L2-4) of the subjects were measured by dual energy X-ray absorptiometry. The average age of the subjects was 47.4${\pm}$11.7 years old, the average weight was 57.2${\pm}$8.4kg, the average age of menarche was 16.6${\pm}$1.9 years old and the average age of menopause was 48.4${\pm}$5.3 years old. The nutrient intakes of the subjects measured by the convenient method were generally lower than the level of RDA. The result of nutrient intake assessed has shown that the average energy intake was 1701${\pm}$316kca1 which is 85.1% of the RDA and the average calcium intake was 485.4${\pm}$172.3mg which is 69.3% of the RDA. The intakes of protein, vitamin A, vitamin B$_1$, niacin were greater than the RDA, whereas the remaining nutrient intakes were lower than the RDA. The average BMD of the subjects was shown to be 1.06${\pm}$1.09g/$\textrm{cm}^2$. The highest BMD of 1.24${\pm}$0.14g/$\textrm{cm}^2$ was noticed in the subjects of 30s compared to 20s, 40s, 50s, 60s. The BMD values were compared by the relative body weight(R3W) of the menopause subjects, and it was found that the underweight group had significant lower BMB while the rest of the groups did not have any differences in BMD. The most strongly correlated nutrient with BMD among the menopause subjects appeared to be calcium. The women whose Ca intakes were higher than 500mg showed the significantly higher BMD than those with Ca intakes lower than 500mg. This study suggests that the most effective way to prevent osteoporosis and to reduce the incidences of fractures seems to be minimizing bone loss through the adequate intake of calcium as well as avoiding underweight, especially in menopausal women. (Korean J Nutrition 31(9) . 1446-1456, 1998)

  • PDF

Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device (T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향)

  • ;;;C. Soutis
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

Detection of Inflow Permeable Zones Using Fluid Replacement Conductivity Logging in Coastal Aquifer (공내수 치환 전기전도도검층을 이용한 연안지역 대수층의 탐지)

  • Hwang, Se-Ho;Park, Yun-Seong;Shin, Je-Hyun;Park, Kwon-Gyu
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • Fluid replacement and conductivity logging have been applied to three boreholes in coastal aquifer in order to identify permeable fractures and to estimate the origin of saline groundwater. Fluid replacement technique measures and monitors the change of borehole fluid conductivity with depth under ambient or pumping condition after replacing the original borehole fluid with different one (by pumping out original one and injecting simultaneously new one at the hole bottom). After the replacement of borehole fluid, the change of fluid conductivity can be the direct indicator of the intake flow of formation water through aquifer such as permeable fractures or porous formations. The conductivity profiles measured with times therefore indicate the locations of permeable zone or fractures within the open hole or the fully slotted casing hole. As a result of fluid conductivity logging for three boreholes at coastal area in Yeonggwang, Jeonam Province, it is interpreted that the seawater intrusion in this area is not by remnant saline groundwater after land reclamation but mainly by intrusion of saline water through fractured rock. This approach might be useful for assessing the characteristics of seawater intrusion, the design of optimal pumping, the mitigation of seawater intrusion using freshwater injection, and estimating the hydraulic characteristics in coastal aquifer.

THE STUDY ON THE DEVELOPMENT OF RELATIVE VALUE IN MEDICAL TREATMENT OF THE ORAL AND MAXILLOFACIAL SURGERY (구강악안면외과 의료행위 상대가치 개발에 대한 조사연구)

  • Song, Gin-Ah;Baek, Kyung-Won;Hwang, Jong-Min;Yu, Soon-Yong;Choi, Jin-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.334-347
    • /
    • 2006
  • The aim of this study is to evaluate the reasonableness of the medical fee on oral and maxillofacial surgery field according to surgeon's opinions and actual conditions. The medical fee has significant influence on hospital income, the supply and distribution of medical manpower, quality and facilities of medical services. Questionnaire survey was sent to 86 oral and maxillofacial surgeons who worked more than 3 years in general hospital. Among them, 25 doctors replied the 109 answers survey and the average of treatment time and physician work relative value on each category was calculated. And the health insurance cost (that has been applied since 2003) was compared with the questionnaire results. And finally we investigated items that health insurance system did not include in oral and maxillofacial field but actually performed in oral and maxillofacial surgery clinic. The result was that the medical fee did not properly reflect physician work relative value of actual treatments. In case of complicated extraction, work relative value needed 3.5 times enhancement of present value. For simple impacted tooth extraction 1.8 times, for impacted tooth extraction including odontomy 1.7 times, and for fully impacted tooth more than 2/3 of it located into the alveolar bone, 1.8 times enhancement needed. In respect of the present physician work relative value, hemimandibulectomy with neck lymph node dissection for the malignancy is appropriated as 3.3 times of open reduction and internal fixation for the mandibular fracture, but the questionnaire result showed 25 times discrepancy. In conclusion, this research shows the need for intervention that health insurance included items and legal relative medical value must act in union with treatment in clinic to reduce the imbalance between them.

FALSE ANEURYSM IN INTERNAL MAXILLARY ARTERY (내악 동맥에 발생한 가성 동맥류)

  • Lee, Jong-Ho;Hong, Soon-Min;Lee, Eun-Jin;Ahn, Kang-Min;Kim, Sung-Min;Myoung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choi, Jin-Young;Choung, Pill-Hoon;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.56-59
    • /
    • 2003
  • The incident of false aneurysm of internal maxillary artery in the oral and maxillofacial region is known to be very rare. One case of false aneurysm in the internal maxillary artery is presented, which was experienced in our department. The etiology of this case is regarded as the mandibular condyle fracture, and/or iatrogenic trauma during open reduction. Clinically, there were systolic bruit on auscultation, pulsation and massive bleeding during operation. The lesion was finally diagnosed with angiography and treated by embolization procedure. False aneurysm can cause so massive bleeding as to threat the life of the patients. Therefore accurate diagnosis and treatment is very important. Angiography enables the solid diagnosis for the clinical one. And as the embolization has many advantages over the ligation, it can be a good treatment method.

Experience and education needs on medication and emergency situations for young children of child caregivers (보육교사의 영유아 대상 투약과 응급상황 경험 및 교육 요구)

  • Noh, Yoon Goo;Lee, Insook;Park, Bohyun
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.359-371
    • /
    • 2018
  • The aim of this study was to investigate experience and education needs on medication and emergency situations for young children of child caregivers. The data from 190 caregivers were collected using open-ended questionnaires composed of four items and analysed by content analysis. The categories derived for each theme were as follows: experience of medication of six categories(no referral for medication, young children refused medication, inaccurate referral, a variety of medication, sick children but not having medication), education need of four categories(for child caregivers, for parents, for children, guideline required), experience of emergency situation of six categories(skin damage or bleeding, decreased consciousness due to seizures, high fever persisted, asphyxiation due to foreign body, dislocation or fracture, emergency not knowing how to cope), education need of emergency situation of five categories(contents, methods, cycle, necessity, institutionalization). It is required to improve more practically the education contents and methods related to medication and emergency situation of child caregivers.

Efficacy and Safety of a Newly Developed Self-Expanding Open-Cell Type Nitinol Stent for Peripheral Arteries: A Preclinical Study in Minipigs (새로 개발된 말초동맥용 자가팽창성 개방형 니티놀 스텐트의 유효성 및 안전성 평가: 미니피그 전임상실험)

  • Min Uk Kim;Jae Hwan Lee;Chang Jin Yoon;Won Seok Choi;Saebeom Hur;Jin Wook Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.899-911
    • /
    • 2020
  • Purpose To evaluate the safety and efficacy of the newly designed open-cell type self-expandable nitinol stent (NiTi-stent) for peripheral arteries. Materials and Methods Twenty-eight limbs of 14 minipigs were randomly assigned to the NiTistent group or conventional nitinol stent group. Stents were symmetrically implanted into the iliac arteries of each animal using carotid artery approach and were observed for 1 month (n = 5) and 6 months (n = 9). The angiographic lumen diameter (ALD), late lumen loss, angiographic stenosis, histomorphometric lumen area, neointimal area, and area stenosis were analyzed and compared between the groups. Results Stent migration, stent fracture, or thrombus formation were not observed in either group. At the 1-month follow-up, the neointimal area (p = 0.008) and area stenosis (p = 0.016) were significantly smaller in the NiTi-stent group than in the control group. At the 6-months followup, the NiTi-stent group showed significantly larger ALD (p = 0.014), less late lumen loss (p = 0.019), less angiographic stenosis (p = 0.014), larger lumen area (p = 0.040), and smaller neointimal area and area stenosis (p = 0.004 and p = 0.014, respectively) compared with the control group. Conclusion The NiTi-stent is as safe and effective as the conventional nitinol stent and induces less neointimal hyperplasia in a minipig iliac artery model.

Determination of Total CO2 and Total Alkalinity of Seawater Based on Thermodynamic Carbonate Chemistry (해수중의 총이산화탄소와 총알칼리도 분석을 위한 탄산염 화학 이론 및 측정방법)

  • Mo, Ahra;Son, Juwon;Park, Yongchul
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • To evaluate accuracy and precision of determination of total alkalinity ($Alk_T$) and carbon dioxide ($TCO_2$) derived from present study, experiment was applied with $CO_2$ CRM (Batch 132, Scripps Institution of Oceanography; $Alk_T=2229.24{\pm}0.39{\mu}mol/kg$, $TCO_2=2032.65{\pm}0.45{\mu}mol/kg$). As the result, average concentration of $Alk_T$ and $TCO_2$ was $2354.09{\mu}mol/kg$ (~5.6% difference with $CO_2$ CRM) and $2089.60{\mu}mol/kg$ (~2.3% difference with $CO_2$ CRM), respectively. For previous method (Gran Titration) by addition $NaHCO_3$ to deionized water($Alk_T$ $2023.33{\mu}mol/kg$), average concentration was $2193.39{\mu}mol/kg$ (sd=57.15, n=7). Whereas, average concentration was $2017.02{\mu}mol/kg$ (sd=10.98, n=7) for the present study. Recovery yield experiments of total alkalinity in deionized water and seawater were implemented by addition of $NaHCO_3$. The recovery yield of deionized water in the range 0 to $4952.39{\mu}mol/kg$ was 100.8% ($R^2$=0.999), and seawater in the range 0 to $2041.32{\mu}mol/kg$ was 102.3% ($R^2$=0.999). Comparison of $pCO_2$ sensor (PSI $CO_2-Pro^{TM}$) with present method showed very meaningful correlation coefficient ($R^2$=0.977) in the range of 427 to $705{\mu}atm$ and 9.16 to $15.24{\mu}mol/kg$ throught elapsed time for two weeks. Field experiment of diurnal variation of total carbon dioxide was accomplished at Sachon harbor in the coastal waters of East Sea of Korea. Concentration of $Alk_T$ and $TCO_2$ was increased during night, and decreased during daylight hours. The results showed mirror type between $TCO_2$ and dissolved oxygen, which was attributable to photosynthesis and respiration of phytoplankton. Also, open ocean field study was performed to obtain vertical profile of $Alk_T$ and $TCO_2$ in C-C zone (Clarion-Clipperton Fracture Zone), Northeastern Pacific. Average concentrations of $Alk_T$ in the surface mixed layer (0~60 m) and deeper layer below 200 m were $2422.38{\mu}mol/kg$ (sd=78.73, n=20) and $2465.87{\mu}mol/kg$ (sd=57.68, n=103), respectively. And average concentrations of $TCO_2$ were $2134.47{\mu}mol/kg$ (sd=65.4, n=20) and $2431.87{\mu}mol/kg$ (sd=65.02, n=103) in the same depth ranges such as $Alk_T$. Vertical distributions of $Alk_T$ and $TCO_2$ concentrations tended to increase with depth, and analyzed concentrations showed slightly higher than those of previous studies in this area.

Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device (좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과)

  • ;;C. Soutis
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section ($length{\;}{\times}{\;}width$) was investigated on the compressive behavior of a T300/924 $\textrm{[}45/-45/0/90\textrm{]}_{3s}$, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm{\;}and{\;}90mm{\;}{\times}{\;}90mm$ gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.