• Title/Summary/Keyword: open cut

Search Result 242, Processing Time 0.031 seconds

Behavior of Braced Rib Arch in Shallow Tunnel Excavated by Semi-Cut and Cover Method (반개착식으로 굴착한 천층터널에서 Braced Rib Arch의 거동)

  • An, Joung-Hwan;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.419-425
    • /
    • 2009
  • Recently, the number of shallow tunnel construction increases to improve the structural safety and environment-friendliness. In Semi-Cut and Cover Method, ground is excavated to the crown arch level and braced rib arch is set to backfill before the excavation of lower face. Semi-Cut and Cover Method is proposed to solve the problems occurred by the conventional Cut and Cover Method, such as unstability, high-cost and the large cutting slope to be reinforced. In this paper, the behaviors of Braced Rib Arch in shallow tunnel excavated by semi-cut and cover method was studied. Model tests in 1:10 Scale were performed in real construction sequences. The distance between supports of rib arch was 1.8 m and the length of spacer was 1.0 m. the size of test pit was 4.0 m (width)$\times$3.3 m (length) 4.0 m (height) in dimension. Tests results show that backfill load acting on arch was smaller than that in the conventional Open-Cut Method.

Dust Fall Property of Open Cut Limestone Mine (석회석 노천채광장의 분진 비산특성)

  • 이상권;김복윤;조영도;김임호
    • Explosives and Blasting
    • /
    • v.17 no.2
    • /
    • pp.45-51
    • /
    • 1999
  • To find out the characteristics and trend of dust fall in open cut limestone mine in-situ measurement and wind tunnel tests were carried out. In-siti measurement was done by two dust fall samplers at the Halls mine for 60 days. The laboratory test was done in the 100m long temporary wind tunnel installed at the yard of the institute. The most of dust falled within 25m form the dust source and only less than 0.5% defused up to over 100 meters. It was known that the dust fall at 100m away from souces were negligible.

  • PDF

Embedded System Design with COS LoRa technology (COS LoRa 기반의 임베디드 시스템 설계)

  • Hong, Seonhack;Cho, Kyungsoon;Yoon, Jinseob
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.3
    • /
    • pp.29-38
    • /
    • 2018
  • It is the approach of embedded system design that analyzes COS(Cut Out Switch) failure in the power distribution and an instantaneous breakdown of power distribution supply could cause the weakness of industrial competence and therefore we need to feed the stable power distribution with developing the technology of open-source embedded system. In this paper, we apply the LoRa technology which is the Internet of Things(IoT) protocol for low data rate, low power, low cost and long range sensor applications. We designed the hardware and software architecture setup and experimented the embedded system with network architecture and COS monitoring system including accelerometer for detecting the failure of distribution line and sensing the failure of its fuse holder by recognizing the variation and collision and afterwards sending the information to a gateway. With experimenting we designed the embedded platform for sensing the variation and collision according to the COS failure, monitoring its fuse holder status and transferring the information of states with LoRa technology.

Temperature Dependence of Microwave Properties of HTS Multipole Lowpass Filters Consisting of Microstrip Open-Stub Lines

  • Kim, Je-Ha;Han, Seok-Kil;Kang, Kwnag-Yong;Ahn, Dal
    • ETRI Journal
    • /
    • v.19 no.2
    • /
    • pp.48-58
    • /
    • 1997
  • Using high quality high-$T_c$ superconducting (HTS) YBCO thin films, we designed and fabricated 3-pole, 5-pole, and 7-pole lowpass filters consisting of microstrip transmission lines and open-stub lines. We measured the microwave response of the filters in the temperature range of T=85 K to 27 K. AtT=30 K, the observed inband insertion loss was 0.14dB and 0.02dB for the 5-pole and 7-pole filters, respectively. The cut-off frequency was 4.7 GHz for the 5-pole filter and 7.9GHz for the 7-pole filter. To the authors' knowledge, the measured inband insertion losses are the best values reported so far for the open-stub line type HTS multipole lowpass filters. The skirt property of the 5-pole filter showed a large improvement over that of the 3-pole filter as predicted from the simulation. We found that, to obtain a stable performance, the HTS multipole lowpass filters should be operated at the temperatures between 60% and 70% of $T_c$.

  • PDF

Dynamic Analysis of a Chain of Rigid Rods

  • Attia, Hazem Ali
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.8 no.2
    • /
    • pp.75-86
    • /
    • 2004
  • In this study, a recursive algorithm for generating the equations of motion of a chain of rigid rods is presented. The methods rests upon the idea of replacing the rigid body by a dynamically equivalent constrained system of particles. The concepts of linear and angular momentums are used to generate the rigid body equations of motion without either introducing any rotational coordinates or the corresponding transformation matrices. For open-chain, the equations of motion are generated recursively along the serial chains. For closed-chain, the system is transformed to open-chain by cutting suitable kinematic joints with the addition of cut-joints kinematic constraints. An example of a closed-chain of rigid rods is chosen to demonstrate the generality and simplicity of the proposed method.

  • PDF

Development of Nondestructive Grouping System for Soil Organic Matter Using VIS and NIR Spectral Reflectance

  • Sung J.H.
    • Agricultural and Biosystems Engineering
    • /
    • v.6 no.1
    • /
    • pp.15-21
    • /
    • 2005
  • This study was conducted to develop a nondestructive grouping system for soil organic matter using visible (VIS) and near infrared (NIR) spectroscopic method. The artificial light was irradiated on the cut soil surface at 15 to 20 cm depths to reduce the errors of light at open field. The reflectance energy from the cut soil surface was measured to group the soil organic matter using VIS/NIR light sensor with narrow band pass filter. From reflectance spectra of soil samples, the sensitive wavelengths for measuring the soil organic matter were selected and compared to previous research results. The grouping system for soil organic matter consisted of light sensor with band pass filter measuring the reflectance energy of the cut soil surface, global positing system (GPS), analog-to-digital (AD) converter, computer and operating software. The regression models to predict the soil organic matter were developed and evaluated. From field test, the accuracies of the developed light sensor system were 81.3% for five-stage grouping of the soil organic matters and 91.0% for three-stages grouping of the soil organic matters, respectively. It could be possible to support the decision making for variable rate applications with the developed grouping system for soil organic matter in precision agriculture.

  • PDF

A Study on the Adapting for Interrupting Capacity Augmentation of Circuit Breaker (차단기의 차단합성성대기적에 관한 연구)

  • 황석영;조무제
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.299-309
    • /
    • 1984
  • This paper proposes the adapter for interrupting capacity augmentation of circuit breaker which can be applied in case of shortage in a existing circuit breaker's interrupting capacity due to utility system extension. The adapter utilizes two winding type of reactor instead of single winding type of reactor and the control of 2ry circuit is excuted by a triac interlocked with the system protective relays actuation so as to cut out the reactor by short circuit of the 2ry winding in normal situation and to cut in the reactor by open circuit of the 2ry winding in abnomal situation such as short circuit accident. As a result of the theoritical analysis and experiment, it is proved that the adaptor can reduce the voltage crop and iron loss due to the reactor signigicantly in normal system condition and do a role of reactor upon the power system accident.

A study on the flow charateristics of temperature control valve by pressure compensation (압력 평형식 온도 조절 밸브의 유동특성 연구)

  • Kim, T.-A.;Kim, Youn J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.419-424
    • /
    • 2001
  • TCV(Temperature control valve by pressure compensation) controls temperature constantly, when it is sending steam or high temperature water to heating device of heat exchanger. For designing TCV, the ratio of piston and hole diameters is one of the important design parameters. Numerical analysis is carried out to elucidate the flow characteristics in the TCV with different port areas of cold and hot waters, using the k-$\epsilon$ turbulence model and Cartesian cut-cell method. Numerical results show that the exit flow rate is mainly affected by pressure distribution in the piston.

  • PDF

A Computer Method for the Dynamic Analysis of a System of Rigid Bodies in Plane Motion

  • Attia, Hazem-Ali
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.193-202
    • /
    • 2004
  • This paper presents a computer method for the dynamic analysis of a system of rigid bodies in plane motion. The formulation rests upon the idea of replacing a rigid body by a dynamically equivalent constrained system of particles. Newton's second law is applied to study the motion of the resulting system of particles without introducing any rotational coordinates. A velocity transformation is used to transform the equations of motion to a reduced set. For an open-chain, this process automatically eliminates all of the non-working constraint forces and leads to an efficient integration of the equations of motion. For a closed-chain, suitable joints should be cut and few cut-joints constraint equations should be included. An example of a closed-chain is used to demonstrate the generality and efficiency of the proposed method.

A study of open cut box curvert tunnel strengthening systems in domestic underground railway (도시철도 개착식 터널의 내진성능보강시스템 개발에 대한 연구)

  • Kim, Ki-Hong;Kwon, Min-Ho;Kim, Jin-Ho;Hur, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1132-1137
    • /
    • 2010
  • There are execute of new laws about prevent of earthquake diaster in nation because of some increments of big earthquake occurence frequency. Now develope new composit plate by ductile fiber with strong mechanic materials, which compose of strengthening systems for the underground structures subject to forced displacements. This study is to focus to develop the retrofitting system for the cut and cuver tunnels built without earthquake type load scenario, so that it can provide the safety of existing urban subway system against earthquakes.

  • PDF