• 제목/요약/키워드: open circuit potential

검색결과 207건 처리시간 0.026초

흡수식냉동기용 열교환기 세관의 부식에 관한 연구 (The Study of Corrosion of Heat Exchanger Tube for Absorption Refrigeration Machine)

  • 임우조;정기철;윤병두
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.147-152
    • /
    • 2002
  • This paper was studied on corrosion of heat exchanger tube for absorption refrigeration machine. In the 62 % lithium bromide solution at $60^{\circ}C$, polarization test of Cu, Al-brass, 10 % cupro nickel(90-10 % Cu-Ni) and 30 % cupronickel(70-30 % Cu-Ni) tube was carried out. And polarization behavior, polarization resistance characteristics, open circuit potential, anodic polarization of heat exchanger tube for absorption refrigeration machine were considered. The main results are as following: The open circuit potential of Al-brass tube becomes less noble than that of Cu tube, corrosion current density of that becomes lower than Cu tube. The open circuit potential of cupronickel tube is more noble than that of Cu tube, corrosion current density of that is controlled than Cu tube. The passivation critical current of 30 % Cu-Ni tube is lower than that of 10 % Cu-Ni tube, potential of passive region of that is more wide than 10 % Cu-Ni tube.

  • PDF

Investigation of buckling behavior of functionally graded piezoelectric (FGP) rectangular plates under open and closed circuit conditions

  • Ghasemabadian, M.A.;Kadkhodayan, M.
    • Structural Engineering and Mechanics
    • /
    • 제60권2호
    • /
    • pp.271-299
    • /
    • 2016
  • In this article, based on the higher-order shear deformation plate theory, buckling analysis of a rectangular plate made of functionally graded piezoelectric materials and its effective parameters are investigated. Assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for the buckling analysis of an FGP rectangular plate are established. In addition to the Maxwell equation, all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. Considering double sine solution (Navier solution) for displacement field and electric potential, an analytical solution is obtained for full simply supported boundary conditions. The accurate buckling load of FGP plate is presented for both open and closed circuit conditions. It is found that the critical buckling load for open circuit is more than that of closed circuit in all loading conditions. Furthermore, it is observed that the influence of dielectric constants on the critical buckling load is more than those of others.

고분자 전해질 연료전지의 개방회로 전위차 측정 및 분석 (Measurement and Analysis of Open Circuit Potential in PEFC)

  • 김홍건;김유신;김홍열
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.134-138
    • /
    • 2004
  • The discrepancies between theoretical values and measured data of PEFC(Proton Exchange Fuel Cell) is carried out for the machine tool power generation. Rudimental approach of theoretical fuel cell open circuit potential using Gibbs free energy is employed for the examination of PEFC module. The stack temperature, stack voltage and stack current are measured during the operation of PEFC module. It is found that stack voltage and current values show the pronounced discrepancy with the results calculated by Gibbs free energy approach. It is analysed that the discrepancy is due to activation polarization, concentration overvoltage and ohmic overvoltage.

  • PDF

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Stability analysis of transversely isotropic laminated Mindlin plates with piezoelectric layers using a Levy-type solution

  • Ghasemabadian, M.A.;Saidi, A.R.
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.675-693
    • /
    • 2017
  • In this paper, based on the first-order shear deformation plate theory, buckling analysis of piezoelectric coupled transversely isotropic rectangular plates is investigated. By assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for buckling analysis of plate with surface bonded piezoelectric layers are established. The Maxwell's equation and all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. The analytical solution is obtained for Levy type of boundary conditions. The accurate buckling load of laminated plate is presented for both open and closed circuit conditions. From the numerical results it is found that, the critical buckling load for open circuit is more than that of closed circuit in all boundary and loading conditions. Furthermore, the critical buckling loads and the buckling mode number increase by increasing the thickness of piezoelectric layers for both open and closed circuit conditions.

공작기계 동력용 연료전지의 전압과 전류특성에 관한 연구 (Electric Voltage and Current Characteristics of Fuel Cell for Machine Tool Power Supply)

  • 김홍건;김유신;김홍열
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2005
  • PEMFC (Proton Exchange Membrane Fuel Cell) is considered as an attractive option to produce electric power in manyapplications. A fundamental step of theoretical fuel cell open circuit potential is examined and compared with the measured data from 1.2KW PEMFC module. The hydrogen pressure and stack temperature are also measured during the operation of PEMFC module. It is found that the stack voltage and current data agree in general with the results calculated by chemical potential approach though they still have a discrepancy. It is analysed that the discrepancy is due to activation polarization, concentration overvoltage and ohmic overvoltage.

해양환경중에서 SS400강재의 간극부식거동에 관한 연구 (Study on the Crevice Corrosion Behavior of SS 400 in Marine Environment)

  • 임우조;정기철;안석환;윤병두
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.1-6
    • /
    • 2000
  • This paper was studied on the crevice corrosion behavior of SS 400 in marine environment. In 0%, 2%, 3.5%, 5% NaCl solution, the aspect of the crevice corrosion and polarization behavior under the crevice corrosion was investigated. And Weight loss rate of SS 400 with crevice and non-crevice was measured according to the NaCl concentration. The main results obtained are as follows : 1) Under crevice corrosion, the corrosion potential become less noble as the concentration of NaCl solution increased. 2) The current density under open circuit potential was high drained as concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, the current density was low drained. 3) The weight loss rate of SS400 was increased as concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, that of SS400 was decreased.

  • PDF

비정질실리콘 pin태양전지에서 입사광 세기에 따른 전류 저압특성 (Incident Light Intensity Dependences of Current Voltage Characteristics for Amorphous Silicon pin Solar Cells)

  • 장진;박민
    • 대한전자공학회논문지
    • /
    • 제23권2호
    • /
    • pp.236-242
    • /
    • 1986
  • The dependence of the current-voltage characteristics of hydrogenated amorphous silicon pin solar cells on the illumimination light intensity has been investigated. The open circuit voltage increases linearly with increasing the logarithm of light intensity up to AM 1, and nearly saturates above AM 1, indicating the open circuit voltage approaching the built-in potential of the pin solar cell above AM 1. The short circuit current density increase with light intensity in proportion to I**0.85 before and I**0.97 after light exposure. Since the series resistance devreses and shunt resistance increases with light intensily, the fill factor increases with light illumination. To increase the fill factor at high illumination in large area solar cells, t6he grid pattern on the ITO substrates should be made. Long light exposure on the solar cells gives rise to the increase of bulk resistance and defect states, resulting in the decrease of the fil factor and short circuit current density. The potential drop in the bulk of the a-Si:H pin solar cells at short circuit condition increases with decreasing temperature, and increases after long light exposure.

  • PDF

다극회전자를 갖는 영구자석기기의 코깅토크에 대한 해석적 예측 (Analytical Prediction for the Cogging Torque of the Permanent Magnet Machines With Multi-Pole Rotor)

  • 장석명;최장영;고경진;박지훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.56-58
    • /
    • 2007
  • This paper deals with analytical prediction for the cogging torque of permanent magnet machines with multi-pole rotor First. open-circuit field solutions are derived using a magnetic vector potential and a two-dimensional (2-d) polar coordinate systems. On the basis of derived open-circuit field solutions and 2-d permeance functions. we also derive the analytical solutions for the open-circuit field considering stator slotting effects and cogging torque. All analytical results are shown in goof agreement with those obtained from finite element (FE) analyses.

  • PDF

풍력발전용 영구자석 다극 동기발전기의 코깅토크의 해석 및 저감 (Reduction and Analysis for Cogging Torque of Permanent Magnet Synchronous Generators with Multi-Pole Rotor for Wind Power Application)

  • 장석명;이성호;최장영
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.375-383
    • /
    • 2008
  • This paper deals with reduction and analysis of cogging torque for permanent magnet synchronous generators with multi-pole rotor for wind power applications. Open-circuit field solutions are derived using a magnetic vector potential and a two-dimensional (2-d) polar coordinate systems. On the basis of derived open-circuit field solutions and 2-d permeance functions, we also derive open-circuit field solutions considering stator slotting effects. By using open-circuit field solutions considering stator slotting effects and energy variation methods, this paper analytically predicts the cogging torque considering skew effects. All analytical results are shown in good agreement with those obtained from finite element (FE) analyses. In order to reduce the cogging torque, by predicting the variation of the cogging torque according to pole arc/pitch ratio using analytical and FE methods, pole arc/pitch ratio which makes the cogging torque minimum are determined. However, we confirm that measured value for cogging torque of the PMG with determined pole arc/pitch ratio is twice higher than predicted value. Therefore, the reason for an error between measured and predicted cogging torque is discussed in terms of a shape of PMs and is proved experimentally.