• Title/Summary/Keyword: ondol floor

Search Result 143, Processing Time 0.027 seconds

Evaluation Methods on ONDOL Thermal Environmental Index (온돌 온열환경지표 평가방법)

  • Kim, Sung-Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.101-110
    • /
    • 2022
  • For this purpose, the authors proposed and proved usefulness of the modified mean skin temperature which is integrated mean radiation temperature and the effect of floor contacted heat conduction. The mean radiation temperature is applied form factor between half cross-legged human body and surrounding wall of indoor. In addition the floor contacted heat conduction is applied heat transfer coefficient of half cross-legged human body. Eight Korean young men were targeted for the experiment. From the experiment the authors excerpted physiological reaction and psychological reaction in Ondol environment which is combined physiccal environmental factor of artificial climate chamber, air and floor temperature. As a result of the experiment it is confirmed that heat conduction has more impact than heat exchange from existing research for the heat exchange between half cross-legged human body and surrounding wall in Ondol thermal environment. Thereby, it is proved the effectiveness of the modified mean skin temperature which is added floor contacted temperature to the Ondol thermal environmental evaluation index.

A Study on the Modernization of the Heating Method of Apartment Houses in the 1950s and 1960s Korea - Focusing on Haengchon, Jongam, Mapo Apartments - (1950~60년대 한국 아파트의 난방 방식 근대화에 관한 연구 - 행촌, 종암, 마포아파트를 중심으로 -)

  • Lee, Byoung-Heon;Kim, Hyon-Sob
    • Journal of architectural history
    • /
    • v.30 no.6
    • /
    • pp.33-44
    • /
    • 2021
  • The traditional Korean heating system ondol, one of the most important characteristics of Korean architecture, still remains as hydronic floor heating. Various studies have been conducted on the modernization of ondol, but the process of introducing the hydronic floor heating has not been seriously studied so far. Therefore, this paper aims to demonstrate how the hydronic floor heating had been introduced to Korea, taking the 1950s and 1960s Haengchon, Jongam, and Mapo Apartments for example - these three are regarded as the first Korean apartment houses after the Korean War. While Western advanced construction technology was imported for these apartments, various methods of modernizing ondol were also considered. What was remarkable in these attempts is that hydronic floor heating first appeared in Mapo 1st Apartment in 1962, because this is the universal heating method in the present Korea. This fact signifies that the traditional principle of floor heating has been maintained, and it would also be meaningful in terms of architectural exchanges between East and West, if considered along with Wright's application of the Korean heating principle to his houses since 1930s.

Theoretical Analysis on the Applications of the Double-Floor Ondol System (이중 바닥 온돌 시스템의 응용에 관한 이론적 분석)

  • Choi, Won-Ki;Lee, Kang-Young;Lee, Hyun-Geun;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.355-363
    • /
    • 2007
  • The Korean traditional 'Ondol' system has been a target for innovation to meet the requirements of sustainable domestic building and low carbon emission energy utilization. Simulation techniques provide designers and researchers with powerful tools to predict heating load and thermal behaviour of Ondol systems installed in various contexts. However, there are few studies on Ondol models, especially associated with multi-stories buildings of which type covers about 50% of Korean housing stock. In this study, we analyzed the double floor Ondol system on the multi-stories buildings using the ESP-r program. On the basis of the double floor Ondol system, we suggested the new modelling method that is composed of the Vent zone and Ondol zone. Using the this model, sensitivity analysis was carried out to refine the applicability of the model taking account of control conditions, constructions, air change and air flow network method and CFD analysis using the FLUENT. The air layer has enough temperature to use in heating zone. It is suggested that the simplicity of the model will allow building designers and mechanical engineers easily to implement scenario-based assessments of design options as well as control strategies. Later, we will simulate the real buildings and analyze the air distributions using the Fluent according to the various conditions.

Thermoregulatory Responses in the Elderly and the Young under the Ondol System (온돌난방에서 노인과 청년의 피부온 반응 비교)

  • 정유정;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.149-158
    • /
    • 1998
  • The purpose of this study was to investigate the effect of age on the human thermoregulatory responses and to obtain the basic information of the Korean thermophysiological characteristics under the traditional Korean floor heating system-Ondol. The participants consisted of 10 elderly women, 4 elderly men(over 65 years), 10 young women and 5 young men(in twenties). They were exposed to temperature-controlled Ondol room(20$\pm$1$^{\circ}C$, 50$\pm$5%R.H., floor surface temperature: 30$\pm$1$^{\circ}C$) for 60 minutes and wore the same experimental clothing. The postures were performed sitting and supine on the floor. In each pose, rectal temperature, skin.temperature of 10 areas, mean skin temperature, clothing microclimate, body fat were measured. The results were as follows; 1. The rectal temperature gradually decreased and mean skin temperature gradually increased in young and old groups in both supine and sitting pose on heated Ondol floor for 60 minutes. 2. Rectal temperature was different in each pose. The rectal temperature decreased 0.1$^{\circ}C$ in both groups under the condition of sitting and decreased 0.2'c in elderly group under the condition of supine. In supine pose, elderly group was more declined than young group. Mean skin temperature increased 0.5$^{\circ}C$ in both poses, both groups.

  • PDF

A study to choose damping material used to reduce floor impact noise considering structural stability of Ondol layer (온돌층의 구조안정성을 고려한 바닥충격음 완충재의 선정기준에 관한 연구)

  • Im, Jung-Bin;Lee, Byung-Kwon;Go, Jong-Chul;Hwang, Kyu-Sub
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.835-838
    • /
    • 2008
  • In this study, long-term compression displacement of damping materials used to reduce floor impact noise and compressive load that crack begins to happen in Ondol layers including the material were measured as basic research to make guide line for right choice of damping material considering structural stability of Ondol layer. From the result, it was found that compression displacement by elapsed time as well as early displacement of damping material when load is applied on Ondol layer are should be included in the guide line for the choice of damping materials. And no problem is expected to be in structural stability of Ondol layer in case choose a damping material that compression displacement at three months later from inflict load is within 10% than initial thickness.

  • PDF

The History and Characteristics of Korean Traditional Ondol(Gudle) studied through Document Analysis (문헌에 의해 분석된 한국 전통 온돌(구들)의 역사와 특성)

  • Kim, June Bong;Jeong, Sang Kyu
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.3-10
    • /
    • 2008
  • Since fire was founded in the world, human races have invented various heating methods. Ondol is traditional heating method in Korea. It is very the important work to trace the history and characteristics of Ondol which originated and was developed in the Korean peninsula. Especially, the study on Ondol will contribute to improving the present heating methods and predicting future ones. In this paper, we shall study through the analysis of documents such as oriental documents, the document of Choseon dynasty, European documents and American documents. In order to discover the origins of Ondol as one of the excellent heating method all over the world, This study aims at identifying the history and characteristics of Ondol in the Korean peninsula, through document analysis. Results of this study are as follows. 1) The first document about Ondol is Sookyongjoo(水經注), Chinese ancient geography book. Contents recorded in the book include the description related to Ondol at Kwankyesa temple which was located at the border land between Gogooryo(ancient Korea) and the northeast of China. 2) Ondol was popular heating method in Gogooryo(ancient Korea) and it was used in not only Gogooryo but also Silla Kingdom and Beakje Kingdom. Thereafter, it was also used widely in Goryo dynasty and Choseon dynasty. Thereby we know that Ondol has been used as a heating method for a long time in the Korean peninsula. 3) Ondol was covered with a floor paper since the beginning of Choseon dynasty. the paper made room clean and impacted on Korean life style. Because the floor was clean and warm, Koreans thus took off shoes and sat on the floor. 4) Ondol was spreaded to Jeju island in Korea before 16th century but wasn't used widely there. The reason was that Ondol was rare high class heating system and the weather was warm in Jeju island. 5) The overspreading of Ondol caused that poor people built roughly Ondol in the last of Choseon dynasty. So, the quality of Ondol gradually became lower and lower. 6) A westerner was impressed by the novelty of Ondol and Frank Lloyd Wright had played an important role to update and spread Ondol widely all over the world. Hailing Ondol as the ideal heating system, Frank Lloyd Wright began incorporating it in his buildings back in the U.S. and even invented a modified ondol system, using hot water running through pipes instead of the hot exhaust through flues.

A study on development of dry ondol access floor system for sustainable apartment (지속가능형 공동주택 구현을 위한 건식온돌 이중바닥 시스템 개발)

  • Oh, Jin-Kyun;Sohn, Jang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.689-689
    • /
    • 2010
  • Since the apartment was built by Korea National Housing Cooperation in 1961, the amount of its supply has been increased greatly, especially from the late 70's. Recently there are many ongoing studies regarding sustainable construction apartment in Korea, one of the research is developing sustainable apartment that has longer life cycle. Also according as life's quality of residents is upgrading, complain for impact noise and plumbing system noise from upstair or downstair are increasing more and more. To solve this complains, government established impact noise standard as lightweight impact noise of 58dB, heavyweight impact noise of 50dB and presented standard floor system or recognition floor system to satisfy this impact noise standard. So in this study, the aim is to develop dry ondol access floor system for sustainable apartment which have pleasant and quiet life environment.

  • PDF

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondol(II) - Focused on Theoretical Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성(II) - 이론적 분석을 중심으로 -)

  • Song, Hyun-Kap;Ryou, Young-Sun
    • Solar Energy
    • /
    • v.15 no.2
    • /
    • pp.13-24
    • /
    • 1995
  • Korean traditional Ondol with the sensible heat storage medium has been for a long time used as residential heating system, in these days the concrete Ondol without the heat storage medium was realized as the heating system in the private houses and the apartments. This floor heating system is good for our health. But the concrete Ondol is not desirable for the energy saving and for the maintenance of comfortable room temperature because the heat storage medium is not employed in the concrete Ondol. And as the hot water circulating pipes are buried under the concrete floor, the concrete Ondol system has some kind of problems to be improved. Therefore the new type of Ondol system was developed in this study. And the new Ondol was consisted of latent heat storage material as heat storage medium with a great heat capacity and bioceramics as medium to maintain comfortable room temperature. In this study, the heat transfer characteristics of latent heat storage-bioceramic Ondol was analyzed theoretically.

  • PDF

An experimental study on the heat transfer characteristics of a Ondol-heated space by varying pipe embedding depths and hot water supply conditions (보일러 운전조건 및 마감층 두께 변화에 따른 온돌난방공간의 열특성에 관한 실험연구)

  • 박병윤
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1991.09a
    • /
    • pp.41-47
    • /
    • 1991
  • This study reports the results of the transient temperature response of a floor heating panel according to variation of the hot water supply temperature and the pipe embedding depth. Also, this experiment compares the temperature responses of floor heating panels under the continuous and intermittent heating system. Furtthermore, this study presents some details of the thermal response of Ondol-heated buildings to varying loads and patterns of heat input. The analysis of the thermal performance fo Ondol heating system have been presented.

  • PDF