• Title/Summary/Keyword: on-line measurement

Search Result 1,874, Processing Time 0.028 seconds

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

Studies on the fabrication of transmission line with high and low $Z_0$ using BCB layer (BCB를 이용한 High & Low$Z_0$전송선로 제작에 대한 연구)

  • 한효종;이성대;전영훈;윤관기;김삼동;황인석;이진구;류기현
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.57-60
    • /
    • 2002
  • In this paper, transmission lines with low and high characteristic impedance (Z$_{0}$) are fabricated and analyzed. The transmission lines are fabricated on the benzo-cyclo-butene (BCB) films of a low dielectric constant. For the low Z$_{0}$, two types of coplanar waveguide (CPW) structures are fabricated, which include bottom-ground and double-ground type. Measurement shows that Z$_{0}$ values for each CPW type are 7.3 and 9.4$\Omega$, respectively, at a signal line width of 100 #m. Whit the ratio between the spacing of bottom-ground and the signal line with becomes greater than 2.5, the Z$_{0}$ is nearly saturated. In addition, thin film microstrip lines fabricated using the BCB insertion layers show very low Z$_{0}$ of 25.5$\Omega$, and this impedance is ~64 % of the values obtained from the BCB-based CPW structures of the same line width. Measurement result of CPW on BCB layer is 100.5 Ω.s 100.5 Ω.

  • PDF

Measurement and Analysis for Electric Locomotive Modeling (전기철도 부하모델링을 위한 신형 전기기관차 측정 및 결과분석)

  • Kim Joorak;Han Moonseob;Jang Donguk;Lee Kiwon;Shim Keonbo;Kim Junghoon
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.403-408
    • /
    • 2003
  • This paper presents measurement to develop load model for electric locomotive. Load model is defined as polynomial form and each coefficient is solved by the least square method. Therefore, many data is required for using this method. The measurement is performed on KNR line, from Chongryangri to Donghae. The subject of measurement is voltage, current, active power, reactive power an frequency for EL8100.

  • PDF

Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System (개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가)

  • Kim, Geun-Jun;Kang, Bongsoon
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.619-623
    • /
    • 2018
  • Due to the development of society, the demand for electric power has increased and the quality control of electric power has become an important issue. In order to efficiently perform such power management, we propose a DSP based power measurement system for multi-wire power measurement. Since the conventional power measurement system can measure only the power of one line, a power quality measurement device is required for each line in order to measure the power quality of the individual line. Respectively. The system proposed in this paper proposes a system capable of real-time measurement of power quality at up to 12 points using digital signal processing algorithm, and the prototype based on this system was evaluated through the official test report of Korea Electrotechnology Research Institute. As a result of the performance test, it was evaluated that the error range is excellent at ${\pm}0.3%$.

Optimization of In-line Coagulation/MF Process Using On-line Streaming Potential Measurement (On-line streaming potential 측정에 의한 in-line 약품응집/정밀여과 공정의 최적화)

  • Oh, Jeong-Ik;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.522-528
    • /
    • 2004
  • Microfiltration with in-line rapid coagulation for drinking water production was examined. The in-line rapid coagulation was conducted using newly developed mixing device instantaneous flash mixer. The flux decline during membrane filtration was monitored with coagulant dosage varied. Flux decline was minimized at 1.1mg/L of coagulant dosage, where streaming potential of coagulated water was near zero. The optimum dosage for the process control was explained by dimensionless distance (${\kappa}{\times}a$) of particle pairs, obtained from electrophoresis parameter describing electrostatic repulsion relative to Van der Waals energy between particle pairs in the pre-coagulated water.

A Study of Power Line Network Description Method for Multi path Analysis (다중경로 분석을 위한 전력선 네트워크 기술 방법에 관한 연구)

  • Oh, Hui-Myoung;Choi, Sung-Soo;Lee, Won-Tae;Kim, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2986-2988
    • /
    • 2005
  • To improve the reliability of power-line communication systems, the measurement and analysis has been proceeded in many power-line channel environments. In spite of the wired channel, power line channel has many multi-paths that are changing with load-variation, line-interconnection, impedance mismatching and so on. We accordingly need an analysis method based on the multi-path channel impulse response. Recently, a method to describe the homogeneous Power-line network has been published[1]. In this paper the modified method that can describe both the homogeneous and non -homogeneous power-line network has presented.

  • PDF

Research on the Correlation of Control Malfunction with Induced Voltage of Control Signal Line According to Voltage Change of a Power Line

  • Kang, Dong-Woo;Kim, In-Gun;Ham, Sang-Hwan;Kim, Sung-Yul;Bae, Sungwoo;Kim, Dae-Nyeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.775-780
    • /
    • 2016
  • This induced voltage measurement test and electromagnetic field simulation are related to the possibility of control signal malfunction by power line. Through an experiment, this research analyzed whether the voltage causing control malfunction according to the on/off status of power permitted to power line was induced to control signal line. Also, the research calculated the voltage induced to control signal line and examined the phenomenon by conducting an electro-magnetic field-specific simulation through the finite element method for the cable model used in the experiment.

A Study of Tight-fit Bodice Pattern for 20's Women (20대 여성의 Tight-fit원형설계에 관한 연구)

  • 정복희;나미향
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.8
    • /
    • pp.137-154
    • /
    • 2001
  • This study was made to draft the tight fitting bodice pattern which horizontal and perpendicular stands are to be lightly set, with the consideration of characteristics of body shape in design of clothes. Measurement of body was conducted on 53 women in twenties, and observation was made on surface development pattern by adhesive tape addition method and gypsum method on three standard objects. In the study, bodice pattern was completed by using already made Somato- measurer, compared with existing bodice pattern, and the results are as follows. The result of the correlation analysis by body measurement shows that chest circumference has a relation to B$.$P-front neck point, side neck point, shoulder point, front interscye breadth point, and the item in spine scapulae point has relation to the item of back neck line, and front & back horizontal values. The degree of shoulder slant, width of armhole and of its depth, the amount of breast, back space, back length were shown to be directly measured from the body. In surface development pattern, tight-fit bodice pattern necessary to the breast volume and back space were shown to be investigated and these volume have to be given in setting up basic line for clothes design together with body measurement value. The result of sensory evaluation for appearance test on fitness shows higher value of research bodice including line of shoulder line, front and back interscye breadth, chest circumference, waist circumference, armhole circumference and of its depth, compared with the research bodice in most items. The result of this study is seen showing high effectiveness for the basic data to design the ready-made dress of high sensitivity of high value added tat.

  • PDF

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.