• Title/Summary/Keyword: on vivo test

Search Result 651, Processing Time 0.022 seconds

Comparison of In Vitro, Ex Vivo, and In Vivo Antibacterial Activity Test Methods for Hand Hygiene Products (손 위생 제품에 대한 in vitro, ex vivo, in vivo 항균 시험법 비교)

  • Daeun Lee;Hyeonju Yeo;Haeyoon Jeong
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.1
    • /
    • pp.35-43
    • /
    • 2024
  • Numerous methods have been applied to assess the antibacterial effectiveness of hand hygiene products. However, the different results obtained through various evaluation methods have complicated our understanding of the real efficacy of the products. Few studies have compared test methods for assessing the efficacy of hand hygiene products. In particular, reports on ex vivo pig skin testing are limited. This study aimed to compare and characterize the methodologies applied for evaluating hand hygiene products, involving in vitro, ex vivo, and in vivo approaches, applicable to both leave-on sanitizers and wash-off products. Our further aim was to enhance the reliability of ex vivo test protocols by identifying influential factors. We performed an in vitro method (EN1276) and an in vivo test (EN1499 and ASTM2755) with at least 20 participants, against Serratia marcescens or Escherichia coli and Staphylococcus aureus. For the ex vivo experiment, we used pig skin squares prepared in the same way as those used in the in vivo test method and determined the optimal treated sample volumes for sanitizers and the amount of water required to wash off the product. The hand sanitizers showed at least a 5-log reduction in bacterial load in the in vitro test, while they showed little antibacterial activity in the in vivo and ex vivo tests, particularly those with a low alcohol content. For the hand wash products, the in vitro test was limited because of bubble formation or the high viscosity of the products and it showed low antibacterial activity of less than a 1-log reduction against E. coli. In contrast, significantly higher log reductions were observed in ex vivo and in vivo tests, consistently demonstrating these results across the two methods. Our findings revealed that the ex vivo and in vivo tests reflect the two different antibacterial mechanisms of leave-on and wash-off products. Our proposed optimized ex vivo test was more rapid and more precise than the in vitro test to evaluate antibacterial results.

Anticlastogenicity of $\beta$-Carotene and Galangin using in vivo Supravital Staining Micronucleus Test (In vivo Supravital Staining Micronucleus Test에 의한 $\beta$-Carotene과 Galangin의 소핵생성억제효과)

  • 허문영;김정한;류재천
    • Environmental Mutagens and Carcinogens
    • /
    • v.17 no.2
    • /
    • pp.92-96
    • /
    • 1997
  • The micronucleus test using peripheral blood reticulocytes (RETs) was evaluated in ICR mice treated with N-methyI-N-nitrosourea (MNU) and benzo(a)pyrene [B(a)P] as model clastogens. The frequency of micronucleated reticulocytes (MNRETs) in both positive compounds was similar to other results which were reported previously. On the other hand, an anticlastogenic effect of the natural antioxidant, $\beta$-carotene and one of taroholds, galangin as model anticlastogens were investigated using simultaneous treatment. Mice were treated with a model clastogen alone, or with a model clastogen and a model anficlastogen simultaneously. Both $\beta$-carotene and galangin showed anticlastogenic effects against MNU- or B(a)P-induced micronuclei in mice. However, galangin has stronger activity than $\beta$-carotene. Results from our experiment suggest that the in vivo supravital staining micronucleus test using peripheral blood is useful in the evaluation of clastogenic and anticlastogenic effects.

  • PDF

A STUDY ON A COMPARISON BETWEEN IN-VIVO AND IN-VITRO PHOTOTOXICITY TEST (IN-VIVO와 IN-VITRO에서의 광독성 시험법의 비교에 대한 연구)

  • Lee, Ho;Koh, Jae-Sook;Park, Won-Jae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.57-76
    • /
    • 1993
  • Phototoxicity is a complex phenomenon which may involve photochemical reaction and biological response mechanism. This complexicity and iii mal protecting tendency has led to the development of various in-vitro approaches as sensitive, alternative test to the in-vivo phototoxicity test. In this study, we investigated not only the sensitivity of two microorganism, (C. albicans and 5. typhimurium TA 98 about UV) but also a correlation between in-vitro and in-vivo phototoxicity test using UV A and 1 Furthermore, we studied the effect of irradiation method which were as follows 1) irradiate to material and microorganism, simultaneously 2) irradiate to only material 3) irradiate to material and microorganism, respectively In each irradiation method, it showed no significant difference, However we were able to observe the more sensitive phototoxicity in S. typhimurium TA 98 than C. albicans, and the results of in-vitro test using 5. typhimurium TA 98 had a good correlation with those of in-vivo test.

  • PDF

Fabrication of Ex vivo Cornea Model for a Drug Toxicity Evaluation (약물 독성 평가용 생체외 각막 모델 제작 연구)

  • Kim, Seon-Hwa;Park, Sang-Hyug
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.143-150
    • /
    • 2019
  • To evaluate the toxicity of ophthalmic drug, the Draize test and Bovine Corneal Opacity and Permeability (BCOP) test commonly used. In Draize test, experimental animals were under stress and pain due to long-term exposure of drug. In addition, regarding physiological functions, animal model is not perfectly reflected a human eye condition. Although some models such as $EpiOcular^{TM}$, HCE model, LabCyte Cornea-Model, and MCTT $HCE^{TM}$ were already presented advanced cornea ex-vivo model to replace animal test. In this sense, cornea tissue structure mimicked ex-vivo toxicity model was fabricated in this study. The corneal epithelial cells (CECs) and keratocytes (CKs) isolated from rabbit eyeball were seeded on non-patterned silk film (n-pSF) and patterned silk film (pSF) at $32,500cells/cm^2$ and $6,500cells/cm^2$. Sequentially, n-pSF and pSF were stacked to mimic a multi-layered stroma structure. The thickness of films was about $15.63{\mu}m$ and the distance of patterns was about $3{\mu}m$. H&E stain was performed to confirm the cell proliferation on silk film. F-actin of CKs was also stained with Phalloidin to observe the cytoskeletal alignment along with patterns of the pSF. In the results, CECs and CKs were shown the good cell attachment on the n-pSF and pSFs. Proliferated cells expressed the specific phenotype of cornea epithelium and stroma. In conclusion, we successfully established the ex-vivo cornea toxicity model to replace the eye irritation tests. In further study, we will set up the human ex-vivo cornea toxicity model and then will evaluate the drug screening efficacy.

Antigenotoxicity of Quercetin and its Glycosides (Quercetin 및 Quercetin 배당체들의 유전독성억제효과)

  • 허문영;김정한
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.2
    • /
    • pp.115-121
    • /
    • 1996
  • In order to compare the suppressive effect of quercetin and several its glycosides, such as quercitrin (quercetin-3-rhamnoside), isoquercitrin (quercetin-3-glucoside), hyperin (quercetin-3-galactoside) and tutin (quercetin-3-rhamnosyl glucoside), on the genotoxicity by N-methyl-N-nitrosourea(MNU), in vitro sister chromatid exchange(SCE) test using mouse spleen lymphocytes and in vivo micronucleus test using mouse peripheral blood were performed. MNU-induced SCEs in vitro were not decreased by the simultaneous treatment of test compounds. Among them, quercetin and hyperin showed significant suppressive effects at high dose(10-5M). On the other hand, MNU-induced micronucleated reticulocytes(MNRETS) in vivo were significantly decreased with good dose-dependent manner in all compound tested. However, there were not significant differences between quercetin aglycone and its glycosides in the suppressive aglycone and its glycosides may act as an antigenotoxic agent in vivo and may be useful as a chemopreventive agent of alkylating agent.

  • PDF

The screening test on the efficacy of anthelmintics by using third-stage larvae and adult of cultivation in vitro (시험관내에서 인공배양한 제 3기 자충 및 성충을 이용한 구충효능 선발시험)

  • Jee, Cha-ho;Park, Seung-jun
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.589-594
    • /
    • 1998
  • The in vitro screening tests against the in vitro cultivated $L_3$ of Ascaris suum (in vitro $L_3$), which were cultivated from the embryonated egg to third-stage larva on 7 days in culture(DIC) and the in vivo rat's lung-derived $L_3$ of Ascaris suum (in vivo $L_3$), which were recovered from the lungs of rat on 7 days after infection, carried out in order to compare the anthelmintic efficacy of in vitro $L_3$ and that of in vivo $L_3$ in RPMI medium 1640 with 5% bovine calf serum. And also a screening test of efficacy against adult worms of Trichuris suis performed. The efficacies of screening tests were as follows : 1. The screening efficacies of abamectin and ivermectin against the in vitro $L_3$ were all 100% at the 10ppm concentration in RPMI medium 1640 on 5 DIC. 2. The screening efficacies of abamectin and ivermectin against the in vivo $L_3$ were all 100% at the 20ppm on 5 DIC or at 40ppm on 3 DIC. 3. The screening efficacies of abamectin and ivermectin against the adult worms of Trichuris suis were all 100% at 20ppm on 4 DIC. And therefore, the in vitro cultivated $L_3$ of Ascaris suum were used in the screening test as well as the in vivo rat's lung-derived $L_3$ of Ascaris suum. And also the adult worms such as Trichuris suis and filaroids which is small size and difficult to cultivate to vitro, were used in the screening test in vitro.

  • PDF

IN VIVO AND IN VITRO WEAR TEST OF COMPOSSITE RESIN RETORATION (복합레진의 마모에 관한 임상적, 실험적 평가)

  • Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.129-135
    • /
    • 1999
  • In this review article, in vivo and in vitro wear test methods which measure the wear of tooth and restorative material were discribed. In vivo test, the criteria of each test were reviewed. The merits and limitations were also commented. In vitro tests, three dimensional scanning methods which scan the occlusal tooth surface three dimensionally were described. Profilometer method, Pin on disk method, laser scanner method were reviewed and the limitations of each test were commented. Additionally, the structer of the three dimensional scanner which has been developed in Zurich university and has been reputated as the most accurate one was described. This study was partly supported by 1997 post-doctoral foreign study program.

  • PDF

Assessment of genotoxicity of Ssanghwa-tang, an herbal formula, by using bacterial reverse mutation, chromosome aberration, and in vivo micronucleus tests

  • Jang, Ji-Hye;Seo, Chang-Seob;Lee, Mee-Young;Shin, Hyeun-Kyoo;Han, Su-Cheol;Ha, Hyekyung
    • The Journal of Korean Medicine
    • /
    • v.42 no.4
    • /
    • pp.25-39
    • /
    • 2021
  • Objectives: Ssanghwa-tang (SHT) is a traditional herbal formula comprising nine medicinal herbs, and it is used for reducing fatigue in Korea. SHT exerts various effects such as anti-inflammatory, antioxidant, and anti-aging activities, and protection against acute hepatotoxicity. However, the genotoxicity of SHT has not yet been established. Methods: Ten components were identified in SHT water extract by using high-performance liquid chromatography analysis. We assessed the genotoxicity of SHT by using bacterial reverse mutation (Ames test), chromosome aberration, and in vivo micronucleus tests. Results: The contents of paeoniflorin, glycyrrhizin, and liquiritin apioside in SHT were 15.57, 6.94, and 3.48 mg/g extract, respectively. SHT did not increase the revertant colonies of Salmonella typhimurium and Escherichia coli strains in the presence or absence of metabolic activity. Although SHT did not induce structurally abnormal chromosomes in Chinese hamster lung (CHL) cells in the presence of metabolic activity, the number of structurally aberrated chromosomes increased dose-dependently in the absence of metabolic activity. In the in vivo micronucleus test, SHT did not affect the formation of micronuclei compared with the vehicle control. Conclusions: Genotoxicity of SHT was not observed in the Ames test and in vivo micronucleus test. However, based on the results of chromosome aberration test, it can be presumed that SHT has the potential to induce genotoxicity because it induced structurally abnormal chromosomes in the absence of metabolic activity.

STUDIES ON THE IN VITRO SPF TEST METHOD OF SUNSCREEN PRODUCTS

  • K. H. Son;Kim, Y. O.;Lee, J. P.;S. J. Yang;Kim, W. H.;Kim, C. K.;M. Y. Heo;S. J. Jang;Park, S. S.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.528-528
    • /
    • 2003
  • The present study was undertaken to develop the in vitro sun protection factor(SPF) test method having good correlation with in vivo method using human. 8% homomentyl salicylate, P3 reference standard and commercially available sunscreen products were measured by the in vitro method using SPF 290S analyzer, and the SPFs were compared with the SPFs measured by in vivo test method. In vitro SPFs of 8% HMS and P3 reference standard were 4.59 $\pm$ 0.12 and 14.94 $\pm$ 0.83. There are good correspondence, correlation coefficients were 0.9506 and 0.9769 respectively, between the in vitro and in vivo SPFs for the sunscreen creams and lotions. Correlation coefficients of makeup base/liquid foundation, lotion labled with "shake before use" and compact powder were 0.8812, 0.8632 and 0.5984 respectively. The optimum mixture ratio of compact powder and cream base represents 1:0.8. These results suggest that the in vitro SPF test method will be able to be used as an alternative method for in vivo SPF in case of lotion and cream.

  • PDF

Correlation study of in vitro and in vivo test for SPF (Sun Protection Factor)

  • Jihyun, Jihyun-Bae;Sungyeon Ahn;Lee, Haekwang;Seongjoon Moon;Ihseop Chang
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.407-416
    • /
    • 2003
  • In this study, we evaluate the correlation between in vitro and in vivo determination of SPF of sunscreen products containing various ingredients depending on emulsification system. For in vitro approach, we determined SPF by the method of Diffey and Robson using an TransporeTM tape(3M Health care, USA) and SPF 290-analyzer(Optometrics Co. USA). SPF values and standard deviations are calculated and displayed after completion of the run. In vivo SPF values are determined according to KFDA (the Korea Food and Drug Administration) method in panels of Fitzpatrick's skin type II or III. We investigated the difference in SPF data of sunscreen ingredient according to emulsification system. The in vivo SPF data is high in water-in oil(W/O) emulsion than in oil-in water(O/W) emulsion samples. The difference may be due to the particular behavior in each vehicles and its presence on skin surface may produce a different sunscreen film. We obtained the corrlation coefficient between in vitro and in vivo SPF data for O/W (R-squre=0.72 )and W/O emulsion(R-squre=0.77). From these results, we suggest the improvement of methodology using Transpore$^{TM}$ tape as substrate to increase the predictability of in vitro method.d.

  • PDF