• Title/Summary/Keyword: on/off stimulation

Search Result 67, Processing Time 0.023 seconds

The Effect of Repetitive Magnetic Stimulation in an SCI Rat Model with Stem Cell Transplantation (줄기세포를 이식한 척수손상 흰쥐에서 반복자기자극의 효과)

  • Bae, Young-Kyung;Park, Hea-Woon;Cho, Yun-Woo;Kim, Su-Jeong;Lee, Joon-Ha;Kwon, Jung-Gu;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Purpose: We tested whether repetitive transcranial magnetic stimulation (rTMS) improved recovery following spinal cord injury (SCI) in rats with transplantation of adipose tissue-derived stromal cells (ATSCs). Methods: Twenty Sprague-Dawley rats (200-250 g, female) were used. Moderate spinal cord injury was induced at the T9 level by a New York University (NYU) impactor. The rat ATSCs (approximately $5{\times}10^5$ cells) were injected into the perilesional area at 9 days after SCI. Starting four days after transplantation, rTMS (25 Hz, 0.1 Tesla, pulse width=$370{\mu}s$, on/off time=3 sec/3 sec) was applied daily for 7 weeks. Functional recovery was assessed using the Basso, Beattie, and Bresnahan (BBB) locomotor rating scale as well as pain responses for thermal and cold stimuli. Results: Both groups showed similar, gradual improvement of locomotor function. rTMS stimulation decreased thermal and cold hyperalgesia after 7 weeks, but sham stimulation did not. Conclusion: rTMS after transplantation of ATSCs in an SCI model may reduce thermal hyperalgesia and cold allodynia, and may be an adjuvant therapeutic tool for pain control after stem cell therapy in SCI.

Successful Motor Evoked Potential Monitoring in Cervical Myelopathy : Related Factors and the Effect of Increased Stimulation Intensity

  • Shim, Hyok Ki;Lee, Jae Meen;Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.78-87
    • /
    • 2021
  • Objective : Intraoperative neurophysiological monitoring (IONM) has been widely used during spine surgery to reduce or prevent neurologic deficits, however, its application to the surgical management for cervical myelopathy remains controversial. This study aimed to assess the success rate of IONM in patients with cervical myelopathy and to investigate the factors associated with successful baseline monitoring and the effect of increasing the stimulation intensity by focusing on motor evoked potentials (MEPs). Methods : The data of 88 patients who underwent surgery for cervical myelopathy with IONM between January 2016 and June 2018 were retrospectively reviewed. The success rate of baseline MEP monitoring at the initial stimulation of 400 V was investigated. In unmonitorable cases, the stimulation intensity was increased to 999 V, and the success rate final MEP monitoring was reinvestigated. In addition, factors related to the success rate of baseline MEP monitoring were investigated using independent t-test, Wilcoxon rank-sum test, chi-squared test, and Fisher's exact probability test for statistical analysis. The factors included age, sex, body mass index, diabetes mellitus, smoking history, symptom duration, Torg-Pavlov ratio, space available for the cord (SAC), cord compression ratio (CCR), intramedullary increased signal intensity (SI) on magnetic resonance imaging, SI length, SI ratio, the Medical Research Council (MRC) grade, the preoperative modified Nurick grade and Japanese Orthopedic Association (JOA) score. Results : The overall success rate for reliable MEP response was 52.3% after increasing the stimulation intensity. No complications were observed to be associated with increased intensity. The factors related to the success rate of final MEP monitoring were found to be SAC (p<0.001), CCR (p<0.001), MRC grade (p<0.001), preoperative modified Nurick grade (p<0.001), and JOA score (p<0.001). The cut-off score for successful MEP monitoring was 5.67 mm for SAC, 47.33% for the CCR, 3 points for MRC grade, 2 points for the modified Nurick grade, and 12 points for the JOA score. Conclusion : Increasing the stimulation intensity could significantly improve the success rate of baseline MEP monitoring for unmonitorable cases at the initial stimulation in cervical myelopathy. In particular, the SAC, CCR, MRC grade, preoperative Nurick grade and JOA score may be considered as the more important related factors associated with the success rate of MEP monitoring. Therefore, the degree of preoperative neurological functional deficits and the presence of spinal cord compression on imaging could be used as new detailed criteria for the application of IONM in patients with cervical myelopathy.

The Change Characteristic of the Stimulation and Satisfaction of the Brain Wave Reaction to the Visual Stimulation in the Space - Focus on the Influence of the Halogen and Wall - (시각적 공간자극에 나타난 뇌파반응의 자극 정도와 만족도 변화특성 - 할로겐 조명과 벽의 영향을 중심으로 -)

  • Seo, Ji-Eun
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.5
    • /
    • pp.99-107
    • /
    • 2015
  • The purpose of this study is to analyze the change of visual stimulus of users to the space through the experiment of EEG and the satisfaction of users depends on the lighting. To do that, the results measured with EEG experiment focusing on Beta ${\beta}$ were compared to each other to figure out difference in the changes of the activation of human brain on lighting's situation as the lighting off and on in the same space. The difference in the results was verified according to the characteristic of users which classified with 4 types of the spatial sensitivities. The results of this study are as following. Firstly, the spacial sensitivity of user is to communicate well with the different senses with stimulus through interaction among the elements. At this time, the brain plays a major role in build the spacial sensitivity of users as the place to make form. Secondly, there are the differences in the activation of brain depends on lighting situation even in the same space. The stimulus into the brain became generally stronger in images with lighting on than off. Especially, the response in the occipital lobe which connected with the visual center turn out strongly in the image of 'modern natural'. Because the visual stimulus interact well with the bright color, the reflectional texture and the rough texture painted the dark color. Thirdly, the satisfaction of users changed with lighting in the space. But we could know that the satisfaction of users isn't be related to the visual stimulus through the results of this study. Finally, there isn't the difference in the activation degree of brain according to the characteristic which are preference of users into 4 types of the spatial sensitivity through the results came from ANCOVA(analysis of covariance) with SPSS Program 22.

Characterization of Rabbit Retinal Ganglion Cells with Multichannel Recording (다채널기록법을 이용한 토끼 망막 신경절세포의 특성 분석)

  • Cho Hyun Sook;Jin Gye-Hwan;Goo Yong Sook
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.228-236
    • /
    • 2004
  • Retinal ganglion cells transmit visual scene as an action potential to visual cortex through optic nerve. Conventional recording method using single intra- or extra-cellular electrode enables us to understand the response of specific neuron on specific time. Therefore, it is not possible to determine how the nerve impulses in the population of retinal ganglion cells collectively encode the visual stimulus with conventional recording. This requires recording the simultaneous electrical signals of many neurons. Recent advances in multi-electrode recording have brought us closer to understanding how visual information is encoded by population of retinal ganglion cells. We examined how ganglion cells act together to encode a visual scene with multi-electrode array (MEA). With light stimulation (on duration: 2 sec, off duration: 5 sec) generated on a color monitor driven by custom-made software, we isolated three functional types of ganglion cell activities; ON (35.0$\pm$4.4%), OFF (31.4$\pm$1.9%), and ON/OFF cells (34.6$\pm$5.3%) (Total number of retinal pieces = 8). We observed that nearby neurons often fire action potential near synchrony (< 1 ms). And this narrow correlation is seen among cells within a cluster which is made of 6~8 cells. As there are many more synchronized firing patterns than ganglion cells, such a distributed code might allow the retina to compress a large number of distinct visual messages into a small number of ganglion cells.

  • PDF

Efficacy of active noise-canceling headphones in patients undergoing ultrasonic scaling

  • Jeong-Woong Kim;Bo-Ah Lee;Yu-Seon Park;Jinho Chung;Seong-Ho Choi;Young-Taek Kim
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.4
    • /
    • pp.269-282
    • /
    • 2023
  • Purpose: Dental fear hinders patients from receiving appropriate dental treatment. In particular, the noise generated by high-speed air turbines and ultrasonic scalers can adversely affect patients. Many efforts have been made to reduce the discomfort caused by noise, but no methods are definitively recommended. The purpose of this study was to determine the efficacy of active noise-canceling (ANC) headphones in reducing the pain and discomfort associated with dental scaling. Methods: Fifty-five patients requiring scaling and root planing, aged ≥19 years and showing no auditory problems, were included. Scaling was performed for the bilateral maxillary molars and premolars while patients wore headphones, with ANC turned either on or off. The degree of noise and pain reduction in the on and off conditions were surveyed using a visual analog scale (VAS). The Wilcoxon signed-rank test was performed to compare noise-and pain-related discomfort with ANC turned on and off. Results: The sample included 28 men and 27 women with a mean age of 45.45±13.12 years. The average noise-related discomfort score was 3.84±2.12 and 2.95±1.99 when noise-canceling was turned off and on, respectively, with a statistically significant difference (P<0.05). Similarly, the average pain-related discomfort score was 3.78h±2.00 and 3.09±1.96 when noise-canceling was turned off and on, respectively, which was a statistically significant difference (P<0.05). Conclusions: The use of ANC headphones seems to reduce the discomfort caused by noise and pain in patients undergoing scaling.

The Effect of Acupuncture on the Intestinal Smooth Muscle Dysfunction Caused by Enteric Bacterial Infection in Weaning Piglet (돼지의 세균성 위장관 질환에 따른 평활근 기능 이상에 대한 침술의 효과)

  • Kim, Tae-wan;La, Jun-ho;Sung, Tae-sik;Kang, Jeong-woo;Nam, Tchi-chou;Choi, Min-cheol;Yoon, Yeo-sung;Yang, Il-suk
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.415-421
    • /
    • 2003
  • It is now generally accepted that acupuncture is effective in diarrhea caused by bacterial infection. However, its effect on the intestinal smooth muscle dysfunction is not clear. Therefore, we investigated the effect of acupuncture therapy at Jiao-chao (GV-1) on the intestinal muscle dysfunction in weaning piglets orally infected by Escherichia coli. The animals are divided into four groups; 1) E. coli + no-treatment, 2) E. coli + antibiotic, 3) E. coli + acupuncture, 4) normal group. In the three E. coli infected groups, low frequency electrical field stimulation (EFS, 1 Hz) provoked triphasic responses composed of initial relaxation followed by on-contraction and off-contraction. While in the normal group, EFS (1Hz) induced biphasic responses composed of relaxation during the stimulation and off-contraction. At the high frequency (16Hz) EFS, both on-contraction and off-contraction of the E. coli + antibiotic, E. coli + acupuncture and the normal group were larger than those of the E. coli + no-treatment group. In the non-adrenergic non-cholinergic (NANC) condition, only biphasic responses occurred to EFS in all experimental groups and the off-contraction of E. coli + antibiotic, E. coli + acupuncture and the normal group were larger than those of the E. coli + no-treatment group. The response to carbachol of those three groups was also significantly greater than that of the E. coli + no-treatment group. These results suggest that acupuncture is as effective as antibiotic in the dysfunction of colonic circular muscle caused by E. coli infection. The maintenance of contractile neuromuscular transmission seems to be involved in the mechanism of the acupuncture effects on diarrhea.

'OFF' Response and Its Characteristics of Guinea Pig Ureter (기니픽 요관(尿管)에 있어서 OFF Response 발생과 그 특징)

  • Hong, K.W.;Rhim, B.Y.;Peter Binancani;Weiss Robert M.
    • The Korean Journal of Pharmacology
    • /
    • v.16 no.1 s.26
    • /
    • pp.25-34
    • /
    • 1980
  • The in vitro guinea pig ureter responded to 5 sec trains of electrical stimuli with two contractions; the first an 'on response' (ON) occurred with $0.1{\sim}0.3$ sec after the onset o the stimulus train, the second an 'off response'(OFF) occurred $0.2{\sim}1.0$ sec after the termination of the stimulus train. Relaxation occurred between the two responses during a time when the stimulus was still being delivered. Longer duration and/or higher frequencies of stimuli within the train were required to elicit the OFF than the ON. Decreasing temperature from $37^{\circ}$ to $22^{\circ}$ decreased ON amplitude and increased OFF amplitude. $Ca^{++}$-free solution, 2 mM EDTA, 1 mM $Mn^{++}$ or $1{\mu}M$ verapamil rapidly abolished ON. OFF persisted when ON had disappeared by repeated stimulation at 0.12 train per sec. Conversely, caffeine, $50{\mu}M$ and theophylline, $10{\mu}M$ abolished OFF with only slight reduction of ON, and sodium nitroprusside decreased preferentially ON amplitude rather than OFF. Relaxation between ON and OFF was incomplete in low $Na^+$ solution. ON and OFF were not affected by the neural blockers tetrodotoxin, atropine or phentolamine, also pyrilamine and methysergide, and relaxation between ON and OFF was $Na^+$ dependent. Furthermore, ON depends on free $Ca^{++}$ and OFF is more dependent on bound or stored $Ca^{++}$.

  • PDF

Effects of Frequency Type on Muscle Function of the Thigh during Electrical Muscle Stimulation (전기근육자극 시 주파수 차이가 대퇴 근육 기능에 미치는 영향)

  • Woen-Sik Chae;Jae-Hu Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.17-24
    • /
    • 2023
  • Objective: The purpose of this study was to investigate the effects of different frequency on of knee extensors muscle function during electrical muscle stimulation (EMS). Method: In this research, 40 subjects who have no musculoskeletal disorder, and less than a year workout experience were recruited in order to analyze effects of EMS with different stimulus frequency. Forty subjects were randomly divided into four groups of ten subjects in each group. A EMS training program with different frequencies (without EMS [WE], EMS with frequency 30 Hz [E30], EMS with frequency 60 Hz [E60], EMS with frequency 90 Hz [E90]) was assigned to each group. Throughout eight weeks of training, test subjects were simultaneously carried out knee extension exercises such as squat, leg extension, and leg-press while using EMS with different frequency (20 min, pulse width 250 ㎲, on-off ratio 1:1). Isokinetic knee extension strength, muscle activity of the rectus femoris (RF), the vastus medialis (VM), and the vastus lateralis (VL), and the median frequency of the RF, the VM, and the VL were collected and compared between pre and post training in order to find effects of applying EMS with different frequencies. For each dependent variable, a one-way ANOVA was to determine whether there were significant differences among four different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: When compared to WE and E90, E30 causes significant increase in isokinetic knee extension strength. No significant differences were found in EMG values across different EMS conditions. However, the median frequency of the VM in E30 was significantly increased than the corresponding value for WE. Conclusion: The results of this study showed that EMS training with 30 Hz frequency had positive effect on knee extensor. Based of the findings of the present study, EMS training with lower frequency may help the performer to focus on developing strength in knee extensor muscles.

Dynamics of Facial Subcutaneous Blood Flow Recovery in Post-stress Period

  • Sohn, Jin-Hun;Estate M. Sokhadze;Lee, Kyung-Hwa;Lee, Jong-Mi;Park, Mi-Kyung;Park, Ji-Yeon
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.62-68
    • /
    • 2000
  • The aim of the study was to compare effects of music and white noise on the recovery of facial blood flow parameters after stressful visual stimulation. Twenty-nine subjects participated in the experiment. Three visual stimulation sessions with aversive slides (the IAPS, disgust category) were followed by subjectively "pleasant" (in the first session), "sad" music (in the second ), and white noise (in the third ). Order of sessions was counterbalanced. Blood flow parameters (peak blood flow, blood flow velocity, blood volume) were recorded by Laser Doppler single-crystal system (LASERFLO BPM 403A) interfaced through BIOPAC 100WS with AcqKnowledge software (v.3.5) and analyzed in off-line mode. Aversive visual stimulation itself decreased blood flow and velocity in all 3 sessions. Both "pleasant" and "sad" music led to the restoration of baseline levels in all blood flow parameters, while noise did not enhance recovery process. Music on post-stress recovery had significant change in peak blood flow and blood flow velocity, but not in blood volume measures. Pleasant music had bigger effects on post-stress recovery in peak blood flow and flow velocity than white noise. It reveals that music exerted positive modulatory effects on facial vascular activity measures during recovery from negative emotional state elicited by stressful slides. Results partially support the undoing hypothesis of Levenson (1994), which states that positive emotions may facilitate process of recovery from negative emotions.

  • PDF

Development and Performance Testing of a Time-resolved OSL Measurement System

  • Hong, Duk-Geun;Kim, Myung-Jin
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.69-76
    • /
    • 2017
  • Background: Time-resolved optically stimulated luminescence (TR-OSL) is a very useful method for calculating the lifetimes of crystalline quartz and feldspar. Materials and Methods: A compact TR-OSL system was developed, comprising a heater assembly manufactured using Kanthal wire, 2 powerful blue light-emitting diodes (LED, LXHL-PB02) for optical stimulation equipped with VIS liquid light guides, and a photomultiplier tube combined with an optical filter for luminescence detection. A pulse generated from the data acquisition board (NI PCI 6250) was used to initiate on/off signals in LED and TR-OSL measurements. Results and Discussion: The TR-OSL and background signals measured using this TR-OSL system using quartz samples were very similar to those reported in a previous study. Additionally, the lifetimes of the build-up and TR-OSL signals were calculated as $27.4{\pm}2.2{\mu}s$ and $30.3{\pm}0.6{\mu}s$, respectively, in good agreement with the findings of a previous study. Conclusion: It was concluded that the developed TR-OSL system was very reliable for TR-OSL signal measurements and lifetime calculations.