• Title/Summary/Keyword: on/off stimulation

Search Result 67, Processing Time 0.019 seconds

Correlation between Real-Time and Off-Time Subjective Assessments and Physiological Responses for Visual Picture Stimulus (시각자극에 대한 실시간 및 비 실시간 주관적 평가와 생리반응과의 상관관계)

  • Jeong, Sun-Cheol;Min, Byeong-Chan;Min, Byeong-Un;Kim, Sang-Gyun;O, Ji-Yeong;Kim, Yu-Na;Kim, Cheol-Jung;Park, Se-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.27-39
    • /
    • 1999
  • The purpose of this study was to approve the capability of human sensibility evaluation based on physiological responses and real-time subjective assessments. Three well-trained healthy human subjects were participated in the experiments. We measured physiological responses such as Heart Rate Variability(HRV), Galvanic Skin Response(GSR) and skin temperature under rest and visual stimulation conditions, respectively. Off-time subjective assessments were recorded before and after visual stimulations. Real-time subjective assessments were recorded during visual stimulations. The results of physiological responses and off-time and real-time subjective assessments were quantified and compared. The results showed that the correlation between physiological responses and real-time subjective assessments was high (83%) for both the positive and negative visual stimulation. The correlation between the physiological responses and off-time subjective assessments was high (83%) for the negative visual stimulation but was low (15%) for the positive visual stimulation. Although the current observation is preliminary and requires more careful experimental study, it appears that the correlation between real-time subjective assessment and physiological responses is higher than that of the off-time subjective assessment and physiological responses.

  • PDF

A Multi-photodiode Array-based Retinal Implant IC with On/off Stimulation Strategy to Improve Spatial Resolution

  • Park, Jeong Hoan;Shim, Shinyong;Jeong, Joonsoo;Kim, Sung June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • We propose a novel multi-photodiode array (MPDA) based retinal implant IC with on/off stimulation strategy for a visual prosthesis with improved spatial resolution. An active pixel sensor combined with a comparator enables generation of biphasic current pulses when light intensity meets a threshold condition. The threshold is tuned by changing the discharging time of the active pixel sensor for various light intensity environments. A prototype of the 30-channel retinal implant IC was fabricated with a unit pixel area of $0.021mm^2$, and the stimulus level up to $354{\mu}A$ was measured with the threshold ranging from 400 lx to 13120 lx.

Analysis of Surface EMG Power Spectrum and Muscle Fatigue Depending on the Variable of Neuromuscular Electrical Stimulation (표면근전도를 이용한 신경근 전기자극 치료변수에 따른 근피로도 분석)

  • Kim, Gi-Won;Kim, Junesun
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.280-289
    • /
    • 2014
  • Purpose: This study was conducted in order to determine the stimulation variables which should be considered when neuromuscular electrical stimulation (NMES) is applied for a muscle under the normal innervation to minimize muscle fatigue and increase force-generating ability. Methods: A total of 23 healthy men participated in the study and all subjects were randomly assigned to the 1:1 group, 1:3 group, 1:5 group, and control group with on-off ratio of NMES. The subjects performed a fatigue task, consisting of 10 times of isometric contraction sustained by NMES. NMES using Russian current stimulation was applied to muscle fatigue and divided into three sessions by pulse frequency (10 bps, 30 bps, 90 bps). The EMG was recorded using an MP 100 system from the quadriceps femoris muscle in four groups. Results: The differences of delta MdF and delta MF of between on-off ratio groups of 10 bps, 30 bps, and 90 bps pulse frequencies were very significant (p<0.05). According to the results of post hoc of 10, 90 bps, it was greater in the 1:1 group and the 1:3 group compared with the 1:5 group, and no fatigue was observed in the control group. In 30 bps, it was greater in the 1:1 group compared with 1:3, 1:5, and control group (p<.05). Conclusion: Among NMES variables to minimize muscle fatigue, the larger on-off ratio by pulse frequency showed the lower muscle fatigue. Therefore, on-off ratio needs to be great enough, and will be more efficient with the frequency 30 bps rather than of 10 bps and 90 bps.

Effects of Medication and Deep Brain Stimulation on the Finger-tapping Speed and Amplitude of Parkinsonian Bradykinesia (파킨슨성 완서증의 손가락 마주치기 속도와 크기에 대한 약물과 뇌심부자극의 효과)

  • Kim, Ji-Won;Kwon, Yu-Ri;Park, Sang-Hoon;Eom, Gwang-Moon;Koh, Seong-Beom;Jang, Ji-Wan;Lee, Hye-Mi
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • The purpose of this study is to investigate whether medication and deep brain stimulation (DBS) have differential effects on the speed and amplitude of bradykinesia in patients with Parkinson's disease (PD). Five PD patients with implanted DBS electrodes (age: $60.6{\pm}7.4yrs$, H&Y stage: $3.1{\pm}0.2$) participated in this study. FT (finger tapping) movement was measured using a gyrosensor system in four treatment conditions: Med (Medication)-off/DBS-off, Med-off/DBS-on, Med-on/DBS-off and Med-on/DBS-on. Quantitative measures representing average speed and amplitude of FT movement included root-mean-squared (RMS) angular velocity and RMS angle. One-way repeated measures ANOVA showed that RMS angular velocity of Med-on/DBS-on was significantly greater than those of Med-off/DBS-off and Med-off/DBS-on (p < 0.01) whereas RMS angle was not different among conditions (p = 0.06). Two way repeated measures ANOVA showed that only medication improved RMS angular velocity (p < 0.01), whereas both medication and DBS had no significant effect on RMS angle (p > 0.02). Effect size of RMS angular velocity was greater than that of RMS angle in both medication and DBS. This suggests that medication and DBS have differential effects on FT bradykinesia and velocity and amplitude impairments may be associated with different functional aspects in PD.

Turning on the Left Side Electrode Changed Depressive State to Manic State in a Parkinson's Disease Patient Who Received Bilateral Subthalamic Nucleus Deep Brain Stimulation: A Case Report

  • Kinoshita, Makoto;Nakataki, Masahito;Morigaki, Ryoma;Sumitani, Satsuki;Goto, Satoshi;Kaji, Ryuji;Ohmori, Tetsuro
    • Clinical Psychopharmacology and Neuroscience
    • /
    • v.16 no.4
    • /
    • pp.494-496
    • /
    • 2018
  • No previous reports have described a case in which deep brain stimulation elicited an acute mood swing from a depressive to manic state simply by switching one side of the bilateral deep brain stimulation electrode on and off. The patient was a 68-year-old woman with a 10-year history of Parkinson's disease. She underwent bilateral subthalamic deep brain stimulation surgery. After undergoing surgery, the patient exhibited hyperthymia. She was scheduled for admission. On the first day of admission, it was clear that resting tremors in the right limbs had relapsed and her hyperthymia had reverted to depression. It was discovered that the left-side electrode of the deep brain stimulation device was found to be accidentally turned off. As soon as the electrode was turned on, motor impairment improved and her mood switched from depression to mania. The authors speculate that the lateral balance of stimulation plays an important role in mood regulation. The current report provides an intriguing insight into possible mechanisms of mood swing in mood disorders.

fMRI of Visual and Motor Stimuli : Difference of Total Activation Depends on Stimulation Paradigm (시각과 운동의 뇌기능영상 : 자극에 따른 총활성화의 차이)

  • 정순철;송인찬;장기현;유병기;문치웅;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • Purpose : To investigate the difference of total activation in visual area, motor area, and cerebellum according to the stimulation paradigm. Materials and Methods : Functional MR imaging was performed in 5 healthy volunteers with visual and motor activity using EPI technique. LED and Checker-Board stimulation were performed for visual activity. Thumb motion and Finger Tapping were performed for motor and cerebellum activity. Stimulus timing was 60sec. off, 120sec. on, 60sec. off. Data processing was carried out by using the cross-correlation method for each pixel. Each pixel was then selected and assumed activated if the correlation coefficient was equal or larger than a threshold value. Time course data was obtained by calculating the total activation which was defined as the number of activated pixel x averaged pixel intensity. Results : In the case of visual activity with LED stimulation, we found increased total activity of more than 100% compared with Checker-Board stimulation. In the case of motor area and cerebellum with Finger tapping stimulation, we found increased total activity of more than 10% and 150%, respectively compared with Thumb motion stimulation.

  • PDF

Stimulating Online Communities-of-Practice: The Influence of Sponsors in Organizations (온라인 실행공동체(Communities-of-Practice) 활성화 요인과 스폰서의 영향)

  • Koh, Joon;Om, Ki-Yong
    • Asia pacific journal of information systems
    • /
    • v.16 no.2
    • /
    • pp.183-203
    • /
    • 2006
  • Firms are increasingly adopting online communities-of-practice (CoPs) with strong managerial support in hopes of promoting knowledge sharing and creation within the organization. Excessive managerial concern and sponsoring, however, could harm the spontaneity of CoP participants, which is one of the pivotal characteristics of virtual communities, and in the end, have negative impact on their smooth operation. In this regard, this study examines the factors which affect the stimulation of CoPs and explores the difference in their operating mechanisms under two differing organizational structural settings by the existence of a sponsor. By analyzing 133 samples of CoPs in a globally leading company, this study found that the existence of a sponsor designated by the organization, has serious influence on the working of CoPs, That is, leaders' enthusiasm and the level of off-line activities are critical factors for the stimulation of CoPs which have no sponsor, while in case of CoPs that have their sponsors, neither leaders' enthusiasm nor the level of off-line activities are significantly related to the stimulation of CoPs. At the same time, the performance of CoPs which have their sponsors was found significantly higher than that of CoPs which have no sponsor. These results indicate that firms need to pay special attention to organizational sponsorship when introducing CoPs within their organizations.

The Influences of G Proteins, $Ca^{2+}$, and $K^+$ Channels on Electrical Field Stimulation in Cat Esophageal Smooth Muscle

  • Park, Jun-Hong;Kim, Hyun-Sik;Park, Sun-Young;Im, Chae-Uk;Jeong, Ji-Hoon;Kim, In-Kyeom;Sohn, Uy-Dong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.5
    • /
    • pp.393-400
    • /
    • 2009
  • NO released by myenteric neurons controls the off contraction induced by electrical field stimulation (EFS) in distal esophageal smooth muscle, but in the presence of nitric oxide synthase (NOS) inhibitor, L-NAME, contraction by EFS occurs at the same time. The authors investigated the intracellular signaling pathways related with G protein and ionic channel EFS-induced contraction using cat esophageal muscles. EFS-induced contractions were significantly suppressed by tetrodotoxin ($1\;{\mu}M$) and atropine ($1\;{\mu}M$). Furthermore, nimodipine inhibited both on and off contractions by EFS in a concentration dependent meaner. The characteristics of 'on' and 'off contraction and the effects of G-proteins, phospholipase, and $K^+$ channel on EFS-induced contraction in smooth muscle were also investigated. Pertussis toxin (PTX, a $G_i$ inactivator) attenuated both EFS-induced contractions. Cholera toxin (CTX, $G_s$ inactivator) also decreased the amplitudes of EFS-induced off and on contractions. However, phospholipase inhibitors did not affect these contractions. Pinacidil (a $K^+$ channel opener) decreased these contractions, and tetraethylammonium (TEA, ${K^+}_{Ca}$ channel blocker) increased them. These results suggest that EFS-induced on and off contractions can be mediated by the activations Gi or Gs proteins, and that L-type $Ca^{2+}$ channel may be activated by G-protein ${\alpha}$ subunits. Furthermore, ${K^+}_{Ca^-}$ channel involve in the depolarization of esophageal smooth muscle. Further studies are required to characterize the physiological regulation of $Ca^{2+}$ channel and to investigate the effects of other $K^+$ channels on EFS-induced on and off contractions.

Estimation of Visual Stimulus Intensity From Retinal Ganglion Cell Spike Trains Using Optimal Linear Filter (최적선형필터를 이용한 망막신경절세포 Spike Train으로부터의 시각자극 세기 변화 추정)

  • Ryu, Sang-Baek;Kim, Doo-Hee;Ye, Jang-Hee;Kim, Kyung-Hwan;Goo, Yong-Sook
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.212-217
    • /
    • 2007
  • As a preliminary study for the development of electrical stimulation strategy of artificial retina, we set up a method fur the reconstruction of input intensity variation from retinal ganglion cell(RGC) responses. In order to estimate light intensity variation, we used an optimal linear filter trained from given stimulus intensity variation and multiple single unit spike trains from RGCs. By applying ON/OFF stimulation(ON duration: 2 sec, OFF duration: 5 sec) repetitively, we identified three functional types of ganglion cells according to when they respond to the ON/OFF stimulus actively: ON cell, OFF cell, and ON-OFF cell. Experiments were also performed using a Gaussian random stimulus and a binary random stimulus. The input intensity was updated once every 90 msec(i. e. 11 Hz) to present the stimulus. The result of reconstructing 11 Hz Gaussian and binary random stimulus was not satisfactory and showed low correlation between the original and reconstructed stimulus. In the case of ON/OFF stimulus in which temporal variation is slow, successful reconstruction was achieved and the correlation coefficient was as high as 0.8.

Changes in Median Frequency of Quadriceps Muscle According to Application Modes of Neuromuscular Electrical Stimulation (신경근전기자극 적용양식에 따른 대퇴사두근의 중앙주파수 변화)

  • Choi, Soo-Hee;Oh, Myung-Hwa;Kim, Tae-Youl;Jeong, Jin-Gyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.49-59
    • /
    • 2005
  • This study assigns each 8 of 24 normal persons to control group(Group I), strength increase group(Group II) and endurance increase group(Group III) to analyze differences in changes of strength and endurance with surface electromyography and kinetics according to application modes of neuromuscular electrical stimulation(NMES). Group I had not any treatment, group II performed 15 repeated contraction with 60% intensity of maximal voluntary isometric contraction(MVIC) by setting 10-sec on time and 50-sec off time and group III conducted 30 repeated contraction with 30% intensity of MVIC by setting 10-sec on time and 20-sec off time. For neuromuscular electrical stimulation, 2,500 Hz of Russian current, 35 pps of pulse rate and 200 of pulse width. Neuromuscular electrical stimulation was conducted by five times for total 4 weeks. Before and after experimentmotor unit action potential of vastus medialis, rectus femoris and vastus lateralis were measured with sEMG, median frequency(MDF) was analyzed, and thus the following results were obtained. There was significant difference in the period of measuring vastus medialis and rectus femoris in change of MDF and interaction among groups with analysis of surface electromyography before and after neuromuscular electrical stimulation(p<.001) and in particular, there was a remarkable change among groups according to the period of measurement. In conclusion, NMES influenced changes of strength and endurance according to its application modes and in particular, it was found that strength increment application had a significant influence on strength increment in applying short-time NMES.

  • PDF