• Title/Summary/Keyword: old and new concrete

Search Result 108, Processing Time 0.021 seconds

A Study on The Example of the Seismic Performance Evaluation Method of Reinforced Concrete Wall Apartment (철근콘크리트 벽식 공동주택 내진성능 평가방법의 적용사례에 관한 연구)

  • Choi, Hyuk-Jun;Park, Tae-Won;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.343-346
    • /
    • 2005
  • Earthquake resistance design has been developed many countries like Japan, USA, Mexico, New Zealand etc., which countries have experienced many earthquakes. Nowadays, earthquake resistance design has come into worldwide use. In Korea, the seismic design regulations have been established since 1988 in order to minimize the economic losses. Recently performance based design method has been adopted as a new Earthquake resistance design method. These regulations, however, are targeted for newly constructed buildings, In Korea, there are no regulations for existing buildings that built before 1988. So, we need to prepare the regulations that evaluate the seismic performance, furthermore proper retrofitting design guideline needs to be proposed when remodeling old buildings. This study was performed that many existing apartments is being a Remodeling object when considering the present condition of existing apartment and the problems of cost and environment in the future plan. When Remodeling construction is reviewed by former the Seismic Performance Evaluation Method, generating problems is evaluation by using Push-over. According to this, it provides the appropriate method of calculating the Seismic Ship Performance Index.

  • PDF

Fundamental Properties of MgO Base Ceramic Mortar for Concrete Repair Material (MgO계 세라믹 모르타르를 활용한 콘크리트 보수재료의 기초물성평가)

  • Park, Joon-Woo;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.4
    • /
    • pp.407-413
    • /
    • 2017
  • The fundamental property of magnesia phosphate cement (MPC) for concrete repair material was investigated in this research. For mechanical properties, setting time, compressive strength and tensile/flexural bond strength were measured, and hydration products were detected by X-ray diffraction. The specimens were manufactured with dead burnt magnesia and potassium dihydrogen phosphate was admixed to activate the hydration of magnesia and a borax was used as a retarder. To observe the pore structure and ionic permeability of MPC mortar, mercury intrusion porosimetry was performed together with rapid chloride penetration test (RCPT). As a result, time to set of Fresh MPC mortar was in range of 16 to 21 min depend on the M/P ratio. Borax helped delaying setting time of MPC to 68 min. The compressive strength of MPC with M/P of 4 was sharply developed to 30 MPa within 12 hours. The compressive strength of MPC mortar was in range of 11.0 to 30.0 MPa depend on the M/P ratio at 12 hours of curing. Both tensile and flexural bond strength of MPC to old substrate (i.e. MPC; New substrate to OPC; Old substrate) were even higher than ordinary Portland cement mortar (i.e. [OPC; New substrate] to [OPC; Old substrate]) does, accounting 19 and 17 MPa, respectively. The total pore volume of MPC mortar was lower than that of OPC mortar. MPC mortar had the entrained air void rather than capillary pore. The RCPT showed that total charge passed of OPC mortar had more than that of MPC mortar, which can be explained by the pore volume and pore distribution.

Influence of post-pouring joint on long-term performance of steel-concrete composite beam

  • Huang, Dunwen;Wei, Jun;Liu, Xiaochun;Zhang, Shizhuo;Chen, Tao
    • Steel and Composite Structures
    • /
    • v.28 no.1
    • /
    • pp.39-49
    • /
    • 2018
  • The concrete bridge decks are usually precast and in-situ assembled with steel girders with post-pouring joint in the construction practice of super-wide steel-concrete composite beam. But the difference of concrete age between the precast slabs and the post-pouring joint has been not yet considered for the long-term performance analysis of this kind composite beam. A simply supported precast-assembled T-shaped beam was taken as an example to analyze the long-term performance of steel-concrete composite beam with post-pouring joint. Based on the deformation coordination conditions of the old-new concrete deck and steel girder, a theoretical model for the long-term behavior of precast-assembled composite beam is proposed in this paper according to age-adjusted effective modulus method. Then, the feasibility of the proposed model is verified by the available test data from the Gilbert's composite beams. Parametric studies were preformed to evaluate the influences of the cross-sectional area ratio of the post-pouring joint to the whole bridge deck, as well as the difference of concrete age between the precast slabs and the post-pouring joint, on the long-term performance of the composite beam. The results indicate that the traditional method without considering the age difference would seriously underestimate the effect of creep and shrinkage of concrete bridge decks. The concrete age difference between the precast slabs and the post-pouring joint should be demonstrated for the life cycle design and long-term performance analysis of precast-assembled steel-concrete composite beams.

A Study on Cheongju Townscape in the 1960s through the Restoration Model (1960년대 청주 도심경관고 -도심 복원모델의 제작을 통하여-)

  • Kim, Tai-Young;Oh, Sungjin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.4
    • /
    • pp.19-29
    • /
    • 2018
  • This study examines the 1960s' townscape through the small-scale restoration model in Seongan-dong and Jungang-dong, Cheongju, one of the historical cities in South Korea. In the 1960s, Jungang-dong actively was developed outside the north gate of Cheongju castle, and Cheongju's townscape was changed by the relocation of railway station and construction of city hall. In the streetscape, the new roads, the east-west Sajik-ro and north-south Sangdang-ro were opened instead of old railroads, and they clarified the typical grid road system with the existing Seongan-ro, which connected north and south gate of the old castle. In the buildingscape, city hall was built in front of the railway station outside the north gate of old castle, and had a great effect on the existing buildings and facilities. The public, educational, and commercial buildings had been replaced by reinforced concrete, and the cement brick & block public housing were distributed widely. But the existing dwelling areas, located in the inside of old castle and outside south gate, showed the low and dense townscape, sustaining the former streets and building types.

Dynamic Behavior of Concrete Dam Constructed with Different Concretes in Mechanical Properties (물성이 다른 콘크리트로 축조된 콘크리트댐의 동적거동 특성)

  • Lim, Jeong-Yeol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.43-50
    • /
    • 2004
  • A large concrete dam, of which construction work had not been continued for more than 20 years because of social problem, was investigated with emphasis on its seismic performance. Mechanical properties of the concrete dam material were estimated by performing uniaxial compression tests for obtained the samples from dam body. Borehole image Processing System (BIPS) was used to investigate the susceptible faults developed in the interface between old an new concretes. Using the results of several laboratory and field tests earthquake response analysis for the dam were done, The results of such investigation show that its physical and mechanical conditions are in a good condition, and the results earthquake response analysis imply that the dam, even it consists of two different concretes, show good seismic performance.

The Characteristics of the Households Prepared for the Stable Elderlyhood Financially and Analysis of Factors Influencing on them (안정적 노후준비 가계의 특성 및 이에 영향을 미치는 요인 분석 - 예비노인의 경제적 노후준비를 중심으로 -)

  • Lee, Sun-Hyung;Choe, Eun-Hee
    • Journal of Family Resource Management and Policy Review
    • /
    • v.14 no.4
    • /
    • pp.193-212
    • /
    • 2010
  • The pre-elderly approaching old age in our society confront having a harsh economic status. The main purpose of this study was to explore the factors influencing the preparation of the pre-elderly for overcoming this status. In particular, it focused on financially stable pre-elderly persons. The data from the 2008 Chungcheongnam-do Welfare Plan for Five Years collected by the Chungnam Women's Policy Development Institute was used to analyze the research questions. The participants in this study included 735 persons (ages 55-64) living in Chungcheongnam-do. Five hundred and eighty-one self-reported questionnaires were used for the final analysis using SAS, version 9.1. This study attempted to identify the important variables needed to find the factors related to socio-demographic and economic characteristics, the adult-child relationship, the preparation plan for old age, etc. The results showed that job and health status were key to preparation for financial stability among the elderly. Another finding was the importance of concrete financial planning for the elderly; that is to say, the pre-elderly who made more concrete plans than indefinite ones were likely to belong to stable households. Another significant finding was that it is important to consider both objective and subjective factors for the financial preparation of the elderly. These results should serve as reference data for the future welfare policy for the elderly, because the financial independence of the elderly will be vital for a healthy relationship between new and old generations.

  • PDF

A study on the seismic behavior of Reinforced Concrete (RC) wall piers strengthened with CFRP sheets: A pushover analysis approach

  • Fatemeh Zahiri;Ali Kheyroddin;Majid Gholhaki
    • Structural Engineering and Mechanics
    • /
    • v.88 no.5
    • /
    • pp.419-437
    • /
    • 2023
  • The use of reinforced concrete (RC) shear walls (SW) as an efficient lateral load-carrying system has gained recent attention. However, creating openings in RC shear walls is unavoidable due to architectural requirements. This reduces the walls' strength and stiffness, resulting in the development of wall piers. In this study, the cyclic behavior of RC shear walls with openings, reinforced with carbon fiber reinforced polymer (CFRP) sheets in various patterns, was numerically investigated. Finite element analysis (FEA) using ABAQUS software was employed. Additionally, the retrofitting of sub-standard buildings (5, 10, and 15-story structures) designed based on the old and new versions of the Iranian Code of Practice for Seismic-Resistant Structures was evaluated. Nonlinear static analyses, specifically pushover analyses, were conducted on the structures. The best pattern of CFRP wrapping was determined and utilized for retrofitting the sub-standard structures. Various structural parameters, such as load-carrying capacity, ductility, stress contours, and tension damage contours, were compared to assess the efficiency of the retrofit solution. The results indicated that the load-carrying capacity of the sub-standard structures was lower than that of standard ones by 57%, 69%, and 67% for 5, 10, and 15-story buildings, respectively. However, the retrofit solution utilizing CFRP showed promising results, enhancing the capacity by 10-25%. The retrofitted structures demonstrated increased yield strength, ultimate strength, and ductility through CFRP wrapping and effectively prevented wall slipping.

Cyclic loading test for concrete-filled hollow PC column produced using various inner molds

  • Chae-Rim Im;Sanghee Kim;Keun-Hyeok Yang;Ju-Hyun Mun;Jong Hwan Oh;Jae-Il Sim
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.793-804
    • /
    • 2023
  • In this study, cyclic loading tests were conducted to assess the seismic performance of cast-in-place (CIP) concrete-filled hollow core precast concrete columns (HPCC) constructed using steel ducts and rubber tubes. The outer shells of HPCC, with a hollow ratio of 47%, were fabricated using steel ducts and rubber tubes, respectively. Two combinations of shear studs & long threaded bars or cross-deformed bars & V-ties were employed to ensure the structural integrity of the old concrete (outer shell) and new CIP concrete. Up to a drift ratio of 3.8%, the hysteresis loop, yielding stiffness, dissipated energy, and equivalent damping ratio of the HPCC specimens were largely comparable to those of the solid columns. Besides the similarities in cyclic load-displacement responses, the strain history of the longitudinal bars and the transverse confinement of the three specimens also exhibited similar patterns. The measured maximum moment exceeded the predicted moment according to ACI 318 by more than 1.03 times. However, the load reduction of the HPCC specimen after reaching peak strength was marginally greater than that of the solid specimen. The energy dissipation and equivalent damping ratios of the HPCC specimens were 20% and 25% lower than those of the solid specimen, respectively. Taking into account the overall results, the structural behavior of HPCC specimens fabricated using steel ducts and rubber tubes is deemed comparable to that of solid columns. Furthermore, it was confirmed that the two combinations for securing structural integrity functioned as expected, and that rubber air-tubes can be effectively used to create well-shaped hollow sections.

An Experimental Study on the Bond Strength of Polymer-Modified Mortars (폴리머 시멘트 모르타르의 부착강도에 대한 실험적 연구)

  • Park, Hun-Il;Song, Ki-Min;Park, Sang-Sun;Sin, Hong-Chul;Sin, Ju-Jae;Kim, Young-Kun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.629-632
    • /
    • 2008
  • In the concrete repairing industry, it's very significant to apply adequate repair materials and construction method in order to extend service life of deteriorated concrete structure efficiently. also, adequate diagnosis of deteriorated structure's status should be involved. This paper describes an investigation of bond strength of polymer modified mortar applied both old deteriorated concrete surface substrate and well cured new concretes. The purpose of this investigation is comparing how much the tensile bond strength on construction site is different from laboratory test results. in the results of investigation, most of sample tested in laboratory is in compliance with KS F 4042's specification. and most of results of construction site are not in compliance with the specification cause of low tensile strength of concrete's surface.

  • PDF

A study on utilizatio of metal-mine tailings for polymer cement mortars (폴리머 시멘트 모르터용 골재로서 금속광산 폐광미의 활용연구)

  • 민경원
    • Economic and Environmental Geology
    • /
    • v.32 no.1
    • /
    • pp.13-18
    • /
    • 1999
  • The tailings stocked at two tailing piles in Sangdong aea have raised collapse hazards and various environmental problems. A trial for effective utilization of tailings as fine aggregates for polymer concrete has been performed along with mineralogical and physical characterization of tailings. The tailings from the Sangdong mine, mainly composed of quartz, orthoclase, amphiboles and muscovite, are alkaline and tailings at the new tailing pile are generally finer in grain size than those at the old tailing pile. In case of using New Tailings as fine aggregates, cement mortar with equivalent amounts of tailings and sands shows the highest compressive strength. Cement mortars containing tailings show lower values of compressive strength, splitting tensile strength and flexural strength than those not-containing tailings. Mixture of polymers such as SBR and EVA in cement mortars raises strengths of cement mortars effectively, which shows potential possiblity to utilize the tailings in Sangdong area as fine aggregates for polymer concretes.

  • PDF