Characteristics of Interior Space and Planning for Elderly Day Care Center in Korea (우리나라 노인주간보호시설의 실내공간 특성과 계획안)

  • 이선주;권오정
    • Journal of Families and Better Life
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • Day care center for the elderly is an alternative for community care for frail elderly who need social participation and physical cares and services outside the family. The purpose of this study was to identify the present situation of day care center for the elderly and to suggest desirable interior space plans for elderly day care center. Data were collected by two ways; a mail survey and case studies of existing day care centers. Five cases of day care centers were analyzed to find out Physical and space problems, available programs and services. Also, the staffs in 96 day care centers for the elderly in nationwide were selected for a mail survey and 68.8 percentage of all was collected and analyzed. From the result of case studies, narrow space and lack of accessibility features for wheelchair or other prosthetic devices were the major problems. From the result of a mail survey analysis, the elderly users were over 73 years old, and high proportion had suffered from dementia and apoplexy Also, staffing ration was 1:7 In other words, one staff was caring of 7 old people, and supporting staff was insufficient. Therefore, supportive, therapeutic environment Was more important issue to improve quality of care. Separate program room and outdoor space, lounging space, treatment room by gardening, separate counselling room, bedroom, a simple kitchen unit, staff office, separate physical treatment room, resting room for staff was indicated more necessarily. When priority of planning interior space was safety followed by accessability and convenience, it was also reported that sire of each room was generally narrow. The most serious problem in interior space was the lack and narrowness of space, and accessible features for mobility. Based on the literature review and the findings of this study, two types of floor plans for elderly day care center were suggested;‘a mixed type for the elderly with and without dementia’and‘a separate type for the elderly with dementia.’The main goals for designing interior space for two types of elderly day care center were to provide safe environment, encouraging environment for remaining abilities of users, sanitary environment, therapeutic environment, familiar environment, and socially-encouraging environment. The recommendations for further studies were suggested.

Consideration on design procedure of room-and-pillar underground structure part I: parametric study (주방식 지하구조물의 설계 방법 고찰 Part I: 매개변수 연구)

  • Lee, Chulho;Hwang, Jedon;Kim, Eunhye;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.5
    • /
    • pp.487-495
    • /
    • 2014
  • In this study, in order to suggest the design method for supports in the room-and-pillar underground structure, the case study was carried out. In the case study, shape of rock pillar and room was mainly considered. From the analysis, a displacement at the roof, the maximum principle stress and plastic state were examined. To optimize variables in the case study, cases from the Seoul metro station were analyzed, then a target depth of the underground structure and ground conditions were determined. And the height of rock pillar and room were chosen from the assumed purpose of underground space, i.e. living/office and warehouse. Total cases of analysis was 180 cases including 3 types of ground condition, 5 types of rock pillar and 6 types of roof span. It is expected that results from analysis can be used to determine the installation of support in room-and-pillar underground structure with stability, utilization efficiency of underground space and applicability of vehicles.

Stereo Acoustic Echo Canceller Using Difference Components of Channel Signals (채널 신호의 차성분을 이용한 스테레오 음향 반향 제거기)

  • Kim Hyun Tae;Park Jang Sik;Son Kyung Sik
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.119-122
    • /
    • 1999
  • In stereo acoustic echo canceller scheme, adaptive filters coefficients converge very slowly or misconverge to real acoustic echo path in receiving room. This is due to cross-correlation between channel signals. In this paper, new preprocessor using absolute difference factor between stereo signals is proposed to reduce cross-correlation between signals. Computer simulations demonstrate that this preprocessor perform well to the half wave rectifier which has simple and good performance of the several preprocessors in recent papers. When the paths in transmitting room change, performance does not degrade in proposed preprocessor.

  • PDF

Application of the Worksheet for Economics Evaluation of Lighting Systems (조명시스템의 경제성 평가를 위한 Worksheet 적용)

  • Sim, Sang-Man;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • It is important to decide the best beneficial lighting system in the space when we design the lighting at first stage. A Worksheet to simplify the evaluation of the economics of the lighting system was developed. And it was applied to a general office room for each lamp and ballast combinations, and to a factory room with a high ceiling for each HID lamp systems. When we design the lighting system using the Worksheet, we can easily evaluate the economics through converting the total cost invested on the lighting system to the present value or the annual cost.

  • PDF

A Study on the Evaluation for Reduction Effect of Hydraulic Turbine Dynamo Noise after Establishment of Soundproof Measure (방음대책 수립 후 수차발전기 소음의 저감효과 평가에 관한 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.133-137
    • /
    • 2007
  • As the waterpower generation plant, the subject of this Study, is a facility that produces plenty of electricity corresponds to $196{\sim}240GWh$ annually, and in its generation process it creates a loud noise when the turbine related to the hydraulic turbine dynamo revolves, and since such loud noise must be transmitted to the dynamo room and amplified, it is effecting a lot of influences to the adjacent office and space. In such viewpoint, this Research, based on the soundproof measure presented at the preceding research, has attempted to evaluate about the effect of noise-reduction countermeasure against the hydraulic turbine dynamo using Auralizational Technique through Psycho-Acoustics Experiment. It deems that such result could be applied hereafter as the useful material when setting up a soundproof countermeasure for the hydraulic turbine dynamo room in dam.

  • PDF

The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory (화학공장의 소방안전을 위한 원격감시 제어시스템 개발)

  • Kim, Hyung-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

A Fundamental Study for Calculation of Daylight Responsive Dimming Control Slope in different Height of Roller Shade (Roller Shade 높이 변화에 따른 광센서 조광제어기울기 산정을 위한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.257-262
    • /
    • 2008
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in the room. But, it has a problem of an excessive direct sunlight. This study calculated daylight responsive dimming control slope by Roller Shade system with Mock-up test. With three 1/2 scale Mock-up rooms, we performed a test for calculation of daylight responsive dimming control slope in different shade height of each room through the different height of roller shade systems. This research will be used as a fundamental study for automated roller shade systems.

  • PDF

A Study of communication specification of a steam turbine digital control system (증기터빈 디지털 제어 시스템 통신 사양 고찰)

  • Sur, Joong-Surk;Yook, Sim-Kyun;Cho, Chang-Ho;Jung, Chang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.752-754
    • /
    • 1999
  • When we are trying to retrofit turbine control system from analog system to digital one, a new communication network is required to be contstructed. In this paper, we are going to introduce one example of economic communication network, which is reliable in operation from control room and field instruments to office and computer room. It will be installed in a power plant in the case of retrofiting control system of medium size steam turbine.

  • PDF

Transient Flow Characteristics of the Room Air Conditioner (룸에어컨 내부 유동의 과도현상에 대한 수치적 연구)

  • Seo, Hyeon-Seok;Kim, Jin-Baek;Kim, Youn-Jea
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.526-529
    • /
    • 2008
  • Air Conditioner has become a popular comfort providing device since two decades, whether in an office or home especially for warm and wet climate countries. The RAC (Room Air Conditioner) is widely used in various working spaces and residences. It composed of heat exchager, cross-flow fan, stabilizer, rearguider and blade of diffuser region, etc. In this study, numerical analyses based on the prediction of transient phenomena were carried out to investigate the flow characteristics in the RAC, including the impeller, the rearguider, the stabilizer and the blade of the diffuser region. Using a commercial code, FLUENT, the velocity, pressure and streamlines were obtained with unsteady, turbulent flow and no-slip condition. The angular velocities of impeller are located in the 900 rpm. Turbulent closure was achieved using a standard k-${\varepsilon}$ model. A moving reference frame (MRF) approach was adopted to simulate the flow field generated by impeller in the RAC. Results were graphically depicted with various geometrical configurations and operating conditions.

  • PDF

Study of Room Indicator Using Display (디스플레이를 이용한 재실표시장치 연구)

  • Song, Jae-Heon;Choi, Nack-Beom;Lee, Seung-Ho;Lee, Julia;Park, Yong-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1087-1092
    • /
    • 2017
  • This paper describes a work that makes convenient use of room indicator of a professors' office. The functions are divided into two main functions, the main function being the display panel and the additional function LCD display. Both of these functions are designed to be controlled by smart phone application using bluetooth wireless communication.