• 제목/요약/키워드: office room

검색결과 289건 처리시간 0.025초

TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교 (Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement)

  • 김두용;정혁;박재홍;현준호;황정호
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.

일본 노인복지센터의 공간구성 특성에 관한 연구 (A Study on the Characteristics of Space Programs for Senior Center in Japan)

  • 소준영
    • 한국실내디자인학회논문집
    • /
    • 제29호
    • /
    • pp.153-162
    • /
    • 2001
  • This study suggests the basic data required in setting up the standard for the architectural planning of Korean senior center by analyzing the standard and current situation of a senior center in Japan that has the welfare facility system similar to that of Korea and understanding its architectural characteristics. 1) Basic spaces that constitute the senior center in Japan are meeting room, lecture room, library, multipurpose meeting room, conference room, game-recreation room, kitchen, lounge, locker room and office. ADL, kitchen, relaxing room, private bathroom, and special bathroom are needed for adult day care as establishments as an annex and work room is also required for Job training. 2) The area of a senior center is calculated in consideration of its space organization that are required as basic. For the type "A", minimum area of 1,256.42 $m^2$2 and maximum area of 2,050.56$m^2$ and for the type "B", minimum area of 812000$m^2$ and maximum area of 1,604.14$m^2$ are suggested as optimum areas. 3) The circulation planning is presented by the connected between the space organization as well as the circulation system in day care center.

  • PDF

핵의학 종사자의 방사선 피폭에 따른 생체신호 변화 분석 (Analysis of Changed Bio-Signal to Radiation Exposure of Nuclear Medicine Worker)

  • 이훈재;이상복
    • Journal of Radiation Protection and Research
    • /
    • 제32권1호
    • /
    • pp.27-34
    • /
    • 2007
  • 본 논문에서는 일반인과 상대적으로 방사선피폭이 많은 핵의학 종사자들의 생체신호를 측정하여 방사선 피폭에 따른 생체신호 변화 정도를 비교 평가하고자 하였다. 핵의학과 종사자와 타부서 종사자들의 생체신호를 비교평가 하기 위하여 핵의학 종사자는 충북대학교 병원 핵의학과 종사자를 타부서 종사자는 전남대학교 병원 CT설, 일반촬영실, 의무기록실, 접수실 그리고 일반 사무실 종사자들에게 실험을 실시하였다. 실험에 쓰인 계측 장비들은 방사선량 계측을 위하여 Arrow -Tech사(社)의 poket dosimeter를 사용하였고, 생체신호인 심박수, 혈압을 측정하기 위하여 GE Medical Systems사(社)의 TONOPORT V, Heat flux, Skin temperature, Energy expenditure을 측정하기 위하여 Body Media사(社)의 Armband 인 SenseWare 2000을 사용하였다. 실험 결과 다음과 같은 결론을 얻었다. 1) 일일 장소에 따른 개인별 피폭 선량은 핵의학과가 3.05 uSv를 기록하였고, CT실, 일반촬영실, 병원 의무기록실, 병원 접수실, 일반 사무실, 교원 등이 뒤를 이었다. 핵의학과가 다른 장소(핵의학과를 제외한 나머지)에 비해 약1.4배 선량이 많았다. 2) 방사선 누적선량이 Heat flux, Skin temperature, Energy expenditure와는 별다른 관계가 없는 것을 알 수 있었다. 3) Blood pressure 에서는 Systolic blood pressure와 Diastolic blood pressure 이 핵의학과 종사자, 일반사무직 종사자, 일반인이 고르게 나타났다. 방사선선량이 상대적으로 많은 곳에서 근무하는 핵의학 종사자와 다른 직종에 종사하는 사람의 혈압을 비교해 왔을 때 변화가 없었다. 이 같은 결과로 볼 때 방사선 피폭이 상대적으로 많은 핵의학종사자들의 방사선 피폭에 따른 유해는 없다는 것을 알 수 있었다.

난류유동해석을 통한 환기효율의 수치해석적 연구 (Numerical Analysis of Ventilation Effectiveness using Turbulent Airflow Modeling)

  • 한화택
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.253-262
    • /
    • 1992
  • A numerical procedure is introduced to calculate local ventilation effectiveness using the definitions of local decay rate and local mean age. A low Reynolds number $k-{\varepsilon}$ model is implemented to calculate steady state turbulent velocity distributions, and a step-down method is used to calculate transient concentration distributions. Simulations are carried out for several different values of air change rates and several different diffuser angles in a two-dimensional model of a half scale office room. The results show that the local ventilation effectiveness within a room could vary significantly from one location to another. The nominal air change rate based on the assumption of complete mixing of room air does not provide the local ventilation effectiveness information. It is numerically proved that the local mean age distribution obtained from the transient calculation is equivalent to the steady state concentration distribution with homogeneously distributed contaminant sources.

  • PDF

수요계층별 특성에 맞는 원룸주택 계획지침에 관한 연구 - 서울시 강남 및 신촌지역을 중심으로 - (A Study of planning guide on the one-room housing by user characteristics - Focused on Kangnam & Sinchon area, Seoul -)

  • 최은실;최상헌
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.29-34
    • /
    • 2001
  • The purpose of this study is to provide a practical planning guide for the actual conditions and the preference by user characteristics in one-room housing. The data collected through questionnaire surveys from the residents of one-room housing in kangnam & sinchon. 259 samples we collected and are analyzed by using SPSS-PC. The results are follows : 1) Students: Students prefer monthly rent, down town, of officetel type, 8-l0py room size, and semi-furnished 2)Business men: They prefer multi function housing mixed office and residence, down town, officetel type, 11-l5py, and fully furnished housing. 3)Newly marriged couples: Ordinary habitation site, apt type, 16-l8py ,and 5: 5 division of space(bedroom:others) 4) Old age: normal habitation site, residence-commerce complex building type, middle corridor type, and 11-l5py. 5)Couple+child: lease of deposit basis, apt complex site, and 16-l8py.

  • PDF

유니버설 디자인 관점에서 성당 비전례공간 평가 - 부산교구 6개 사례를 중심으로 - (Evaluation on Non-liturgical Space of Catholic Churches from the Perspective of Universal Design - Focused on 6 Cases in Busan Parish -)

  • 조연주;남경화;신경주
    • 한국실내디자인학회논문집
    • /
    • 제24권3호
    • /
    • pp.38-47
    • /
    • 2015
  • This study evaluated non-liturgical space of catholic churches based on the four principles of universal design; accessible design, supportive design, safety-oriented design, and adaptable design. To design those spaces in terms of supportive design principle, diaper exchanging station needs to be placed in the restroom. Findings of this study are as follows: In terms of accessible design, valid width of entrance door to each room(more than 800mm), installation of elevator, height of riser in the stair, and width of step board were appropriate, but there were many spaces where door sils were not removed. In terms of supportive design, notice board at teacher's room and installation of storage closet, and width of passage to office(more than 1,200mm) were also appropriate, but storage closet at a meeting and prayer room, and space for storing flowers appeared inappropriate. To design those spaces in terms of supportive design principle, diaper exchanging station needs to be placed in the restroom. In terms of safety-oriented design, installation of round-edged furniture, use of non-slip flooring material, installation of safety emergency bell at a restroom, and installation of wall handle were required. In terms of adaptable design, space for wheelchair users at each room, installation of the furniture that can adjust the height, installation of desk with different height at an office, installation of toilet and basin considering children were considered to be necessary.

일개 대학병원 간호사의 근골격계 부담작업 분석 (Analysis of Musculoskeletal Burdened Work among Nurses at a University Hospital)

  • 정은희;구정완
    • 대한인간공학회지
    • /
    • 제25권3호
    • /
    • pp.97-103
    • /
    • 2006
  • Severities of musculoskeletal diseases (MSDs) have been recognized at the regular work such as manufacturing but incidence of MSDs are increasing also at the atypical work. The examples of those are health medical workers, office workers and service workers etc. Nurses among health medical workers are accomplishing to manage and recover the patients' health in the first place. Therefore, they are exposed to very stressful work conditions during caring the patients. This study was performed to analyze the musculoskeletal burdened work among nurses at a university hospital, in order to grasp the realities of the MSDs, analyze and prevent MSDs. We surveyed risk factors for ward, intensive care unit, delivery room, newborn room, operation room, function test room and central supply room at a university hospital in Seoul. It was executed for 2 months as the field study that was composed of simulation, real measurement, work motion assessment and subjective assessment. And the results were analyzed into ergonomics techniques. Works according to the criteria of musculoskeletal burdened work by the Ministry of Labor were scrub in operation room and heart ultrasonic function test. And a lot of works that need attention and management were also detected. So it should be required the education and systematic managements of MSDs for nurses.

정보환경조건에 따른 대학도서관의 공간계획에 관한 연구 -도서관 건축 디자인에 관한 연구(II)- (A Study of the Space Planning of a University Library according to the Condition of the Information Environment - A Study on the Design of Library Architecture(II)-)

  • 이상호;신현수
    • 한국실내디자인학회논문집
    • /
    • 제18호
    • /
    • pp.31-37
    • /
    • 1999
  • This study aims to provide architectural basis of the new space planning in university library and anticipate direction in future. This study is to analyze the spatial transition in the existing facility, based on field observation of the domestic university library and on theoretical data from the related article. The result that include a transition of the existing facility and the present is as following as below. 1) Spatial transitions by networking are making specific system room. The minimum area of this specific system room is 33.95$m^2$. 2) Spatial transition by information service is forming computer room. the minimum area of a environmental carrel, which is possibly located to computer room, is 2.98~3.42$m^2$. 3) Spatial transition by spreading multimedia information is to make the multimedia information is to make the multimedia room. It is necessary to independent, flexibility, and extensionable space. 4) Library interior spatial transition by developing information technology is prospected that in case of reading room, office enlarge the scale, in case of stack decrease the scale. The university library must be kept up their function and also be functioned as electronic library which serve new information.

  • PDF

"K" 금융회사 인테리어 디자인 계획안 (A Plan for an Interior Design of the "K" Financial Company)

  • 류혜지;박현옥
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2007년도 추계학술발표대회 논문집
    • /
    • pp.206-209
    • /
    • 2007
  • Today rapid change in information and economy takes the changing of office design. It is very important to understand about the needs of employees and working environment. To promote the efficiency and comfort of the working environment, diverse employee's working characteristic and individual requirements have been observed. To build a good working environment, flexibility of space and communication between employees and employer in the office are very important. Due to the business growth, "K" financial company requires more working space. The design idea for the main areas such as the executive officer's room, the reception, the elevator hall, the conference rooms and the working areas in this project targets the harmony of the functionality and the aesthetic. This project could be able to deliver more convenient and comfortable working place by adopting three main concepts, which are modern, simplicity and moderation.

  • PDF

IP 기반의 다채널 엘리베이터 영상감시 시스템 (A new IP-based Multi-Channel Elevator Video Surveillance System)

  • 신재흥;김홍열
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.164-168
    • /
    • 2013
  • Recently, in the elevator of the buildings, such as apartment and office building, the visitor monitoring cameras for surveillance, advertising LCD to provide a variety of information, emergency call devices, and safe driving information sensors are installed. A variety of multimedia data from these devices to the central control office, management office, or to guard room are transmitted in real-time. Each sub-systems in the elevator are installed with a separate lines and operated independently and use different management principals, so integrated management for each sub-systems are very difficult. In this study, we develop a new IP-based multi-channel video surveillance system which is integrated surveillance camera, emergency call devices, communications devices, various sensors in the elevator, DVR, ODM, and can manage all devices by two-way communication and integrated interface. And we evaluated the performance of the developed system.