• Title/Summary/Keyword: odor pollutants

Search Result 68, Processing Time 0.023 seconds

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.

A Study on Water Quality for Golf Course Pond in Northern Areas in Gyeonggi Porvince (경기도 북부지역 골프장연못 수질특성에 관한 연구)

  • Kim, Jae-Kwang;Hwang, Chan Won;Park, Jin-Ho;Kim, Ji Young;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.323-329
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate the water quality of 16 golf course ponds located in northern areas Gyeonggi province by investigating residual pesticides, organic matters (BOD, TOC) and nutrients (TN, TP). Methods: The result data for the residual pesticides were used from 2014 to 2017. and other result data were used for April and July in 2017. The residual pesticides analytical method was based on 'Golf course residual pesticides inspection method', The others analytical method was based on 'The water pollution process test standard' Results: Very toxic pesticides and banned pesticides were not detected but general pesticides were detected. In case of the water quality of the golf course pond was applied to the lake water quality standard. In April the average TOC concentration was V grade to 6.46 mg/L, TP V grade to 0.13 mg/L, TN VI grade to 1.6 mg/L, In July TOC average concentration was VI grade to 8.65 mg/L, TP VI grade to 0.17 mg/L, TN V to 1.5 mg/L. All TN and TP concentrations corresponded to eutrophication. Compared with lake water quality monitoring, the concentrations of BOD, TOC and TP were high but the TN concentration was low in April and July. Conclusions: It is considered that water quality managements are necessary for the golf course pond. The first reason is that the pollutants of pond are discarded to river during rainfall and act as pollution sources. The second reason is that the golf course users are uncomfortable because of odor caused by the pollutants of the pond.

Cost Evaluation for the Decision of Advanced Treatment Processes (최적 고도정수처리공정 선정을 위한 경제성 평가)

  • Lee, Kyung-Hyuk;Shin, Heung-Sup;An, Hyo-Won;Chae, Sun-Ha;Lim, Jae-Lim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.511-516
    • /
    • 2008
  • Since 1989, Advanced drinking water treatment processes began to build in Korea, especially the water treatment plants around the Nak-dong river stream due to sequential pollutant accidents. Moreover, Advanced drinking water treatment processes, ozone and GAC, are again to be built in water treatment plants around Han-river stream to control taste and odor, micro pollutants. However, there are still a lot of discussion to decide the processes to apply for advanced treatment. Thus there are still need to understand clearly on the cost evaluation of each advanced treatment processes. The cost evaluation was accomplished based on the data of six water treatment plants which are currently being either operating or constructing. Exceptionally, PAC(Powdered Activated Carbon) process was evaluated with cost estimation from construction company. The capital cost per unit volume of ozone process was significantly decreased as the treatment capacity increased. The capital cost was in the order of GAC, ozone and GAC. The operation cost decreased in the order of PAC, GAC and ozone. The total cost considering present value shows that ozone process covers 84% of ozone and GAC process for $30,000m^3/d$ capacity while it covers less than 35% for over 140 thousands $m^3/d$ capacity. Comparing GAC only, and ozone/GAC process, ozone/GAC process is more cost effective for high capacity water treatment plant.

Characteristics Analysis of Water Quality for A Small Stream in Urban Watershed (소규모 도시 하천 유역의 수질 특성 연구)

  • Kwak, Jae Won;Jung, Jong Tae;Kim, Hung Soo;Ahn, Kyoung Soo
    • Journal of Wetlands Research
    • /
    • v.10 no.2
    • /
    • pp.129-141
    • /
    • 2008
  • This study analyzed and assessed the water quality of a small urban stream in the apartment complex of Yewol-Dong, Buchun-Si at Korea. The flows in the stream due to the interceptions of sewage and normal flow are usually low and the water quality and offensive odor problems by inflows of the sewage and other pollutants are occurred in the study area. Therefore we intended to monitor and identify the water quality conditions. Based on this, we simulated water quality using QUAL2E model and investigated water quality characteristics for the future. As the results, we found that the water quality depended on the inflows of point and non-point sources and so it is important to maintain instream flow for improvement of water quality problem and to intercept point and non-point sources in this study area.

  • PDF

A Study on Behavior Characteristics of Volatile Organic Compound Caused by Ventilation in a Room (통풍에 의한 휘발성 유기화합물의 실내 거동 특성에 대한 연구)

  • Kim, Jang-Woo;Chung, Jin-Do
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1011-1016
    • /
    • 2006
  • Recently, volatile organic compound(VOC) has been noted as a main cause of air pollution. VOC, with its toxic and offensive odor, is hazardous to health. Furthermore indoor, underground and hish-rise buildings are preferable living spaces. People spend more than 80% of the day indoor, so indoor air pollution is a matter of importance. In Korea, from 2004, 10 types of indoor pollutants in public facilities have been identified. However, there is no standard for individual VOC, so the regulation has not yet effectively been carried out. In this study, we have studied on the diffusion of Benzene in a room using a numerical analysis for various air-controlled conditions consisted of door, window and ventilation system. This study investigates spatial concentration distribution and time-history of room-averaged benzene concentration for several cases. The results of this study show that when the room is ventilated by a small fan only for 30 minutes, the average concentration of benzene is decreased a very little, thus the impact to human body would be serious compared to the case of natural ventilation by window and door, In the case of natural ventilation by window and door, if the wind speed is higher than 0.5m/s, it takes small than 4 minutes for benzene to spread to the target concentration of $1.2mg/m^3$.

Prevalence of Children's Allergic Diseases in Ulsan: Local Differences and Environmental Risk Factors (울산지역 초등학생 알레르기 질환 유병률: 지역적 차이와 환경위험인자)

  • Oh, In-Bo;Kim, Yangho;Sim, Chang Sun;Lee, Ji Ho
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.472-481
    • /
    • 2012
  • Objectives: This study aims to investigate the AD (allergic diseases: asthma, allergic rhinitis and atopic dermatitis) prevalence among elementary schoolchildren in an industrial city, Ulsan, and identify major environmental risk factors associated with AD prevalence. Methods: Data on the physician-diagnosed prevalence over the past 12 months and potential risk factors of AD were collected through a questionnaire from a 2009-2010 survey of 4,067 schoolchildren living in different urban environments. The logistic regression analysis was performed to assess differences in AD prevalence among the areas and to determine which environmental factors impacted AD. Results: Our survey results showed that the AD prevalence rate ranged between 26.2% and 35.9%. Children living in polluted areas (near industrial and central urban areas) had about a 10% higher prevalence of AD than did those living in coastal or suburban residences. The Chi-Square test demonstrated that this local difference was statistically significant before and after adjustment of major confounders such as parental AD history and parental education. The results of the logistic regression analysis showed a statistically significant association between several environmental factors (ventilation in winter, odor conditions and exposure to traffic smoke, and outdoor $PM_{10}/O_3$ pollution) and the prevalence of AD found by multivariate model after adjusting confounders. Conclusion: These results suggest that local differences in AD prevalence are significantly associated with outdoor environmental factors. Although there are likely to be other risk factors for AD, living in a polluted area and exposure to high levels of air pollutants can contribute to an increased risk of childhood AD.

Quantification of Volatile Organic Compounds in Gas Sample Using Headspace Solid-Phase Microextraction (고상 미세 추출법을 이용한 가스시료 중 휘발성유기화합물의 정량 분석)

  • Kim, Jae Hyuck;Kim, Hyunook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.906-917
    • /
    • 2013
  • The purpose of this study is to quantify volatile organic compounds (VOCs) in gas sample using headspace solid-phase microextraction (HS-SPME) coupled to GC analysis. The optimal HS-SPME conditions was CAR/PDMS fiber and 30 min absorprion time for the analysis of various VOCs. In optimal conditions, 80 VOCs could be detected within 1 ppbv and even less than 0.0005 ppbv especially in the case of BTEX. However, fiber reproducibility on adsorption efficiency was 1~9.2% (between the same fiber) and 5.9~13.5% (between the other fiber). We successfully determined 35 VOCs in landfill gas with this method and found that VOCs of high concentration are emitting from vent pipe of closed/open landfill site under the HS-SPME conditions. This method may apply to VOCs/odor determination from various atmospheric environmental samples as well as landfills.

Variation of Water Quality around the Chudong Intake Tower in Daechung Reservoir (대청호 추동취수탑 부근의 수질변화 특성)

  • Ma, Xin-Chao;Lim, Bong-Su;Heo, Soon-Uk;Kwak, Mi-Ae
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.637-643
    • /
    • 2015
  • This study has been carried out to provide the basic data obtained from the evaluation of the variation of water quality around the Chudong intake tower in Daechung resevoir, which may be able to help the establishment of a pure water supply policy. Five sites around the Chudong intake tower were selected, and the average data for recent ten years(from year 2004 to year 2013) were analysed. The average water quality around Chudong intake tower are as followed; pH 7.5, DO 8.7 mg/L, BOD 1.0 mg/L, COD 3.0 mg/L, SS 3.0 mg/L, TN 1.495 mg/L, TP 0.017 mg/L, and Chlorophyll-a 6.5 mg/m3 were matched the good class by comparing with the living environment standard of reservoir. COD values of higher than 3.0 mg/L after July were likely due to non-point pollutants and algae outbreak during rainy summer season. Total phosphorus rose sharply in the summer season, and then algae watch was issued consistently for average 40 days. Total nitrogen to total phosphorus ratio was average 90, and it is important to control the inflow phosphrous from small stream for proper management to block an algae growth according to eutrophication. It was recommended to operate the algae removing boats around intake tower from July to October, and was required advanced water treatment processes to remove NBD COD and bad odor and taste due to algae growth.

Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology (전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Bitog, Jessie.P.;Hong, Se-Woon;Seo, Il-Hwan;Choi, Ji-Sun;Song, Sang-Hyeon;Moon, Oun-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

Preparation and Application of Charcoal-Encapsulated Methyl Silica Microcapsules (활성탄을 함유한 메틸실리카 마이크로캡슐의 제조 및 응용)

  • Ahn, Bok-Yeop;Lee, Yu-Mi;Ham, Myung-Kyung;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.199-206
    • /
    • 2003
  • The charcoal-encapsulated methyl silica microcapsules were prepared by a O/W microemulsion sol-gel method, and the adsorption properties on aquatic humic acid were investigated. The capsules prepared were spherical, $100{\sim}1000{\mu}m$ in size. The size distribution was controllable by adjusting the size of charcoal powder, charcoal/methyl silica ratio, and agitating speed in O/W sol-gel process. Adsorption efficiency of charcoal for aquatic humic acid was decreased after encapsulation by methyl silica shell. The decreased adsorption efficiency can be dependent on the decrease of the BET surface area and pore volume after encapsulation. Diffusion properties of humic acid through the capsule shell also played an important role on adsorption efficiency. Therefore, the reasonable target pollutants for the capsules can be VOC or odor molecules which can overcome diffusion barrier through shell of capsules in air condition. Functionalization methods for the charcoal-encapsulated $CH_3(SiO)_n$ microcapsules by incorporation of $TiO_3$ as a phtocatalytic function and by incorporation of inorganic pigment as a color function were also investigated. $TiO_2$ coating properties were controllable by adjusting pH, temperature, and the concentration of $TiOSO_4$. In XRD measurement, the crystal form of the coated $TiO_2$ was anatase. For the colorization of the capsules, inorganic pigments were more efficient than organic dyes, and various color was introduced to the capsules using inorganic pigments.

  • PDF