• 제목/요약/키워드: occluder

검색결과 33건 처리시간 0.027초

Surgical Extraction of an Embolized Atrial Septal Defect Occluder Device into Pulmonary Artery after Percutaneous Closure

  • Yolcu, Mustafa;Kaygin, Mehmet Ali;Ipek, Emrah;Ulusoy, Fatih Rifat;Erkut, Bilgehan
    • Journal of Chest Surgery
    • /
    • 제46권2호
    • /
    • pp.135-137
    • /
    • 2013
  • An atrial septal defect is the most common type of congenital heart disease among adults. Surgical repair or percutaneous closure of the defect is the treatment options. Even though percutaneous closure seems to be less risky than surgical repair, it may result in fatal complications like device embolism, cardiac perforation and tamponade. Herein we report a case of the embolism of a device into the pulmonary artery after one hour of percutaneous closure in which the embolized device was surgically removed and the defect was closed with a pericardial patch.

기계식 심장판막의 충격력에 관한 실험적 연구 (An Experimental Study on the Impact Force of a Mechanical HeBrt Valve Prostheses)

  • 이정한;천길정
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.215-220
    • /
    • 1996
  • Impact force and strains induced by impact between the occluder and the struts have been measured with force sensor and strain gages. The maximum reaction force was about 25N, and the calculated impact force on the root of the struts amount about 9-17W. Impact force on the inlet strut is greater than that of the outlet strut, but the strain on the outlet strut is much higher than that of the inlet strut. These values might cause severe damage on the valve in the critical cases. The results of this study may be extended for the analysis of the endurance limit and optimal design of the struts and occluder.

  • PDF

기계식 심장판막의 충격력에 관한 실험적 연구 (An Experimental Study on the Impact Force of a Mechanical Heart Valve Prostheses)

  • 이정한;천길정
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.167-171
    • /
    • 1996
  • Impact force and strains induced by impact between the occluder and the struts have been measured with force senfor and strain gages. The maximum reaction force was about 25N, and the calculated impact force on the root of the struts amount about $9{\sim}17N$. Impact force on the inlet strut is greater than that of the outlet strut, but the strain on the outlet strut is much higher than that of the inlet strut. These values might cause severe damage on the valve in the critical cases. The results of this study may be extended for the analysis of the endurance limit and optimal design of the struts and occluder.

  • PDF

The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder

  • Kim, Soo Jin;Huh, June;Song, Jin Young;Yang, Ji-Hyuk;Jun, Tae-Gook;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • 제56권4호
    • /
    • pp.176-181
    • /
    • 2013
  • Purpose: Apical muscular ventricular septal defects (MVSDs), especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies. We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO). Methods: We retrospectively reviewed the medical records of 5 patients who underwent hybrid perventricular closure of MVSDs with ADOs, from March 2006 to May 2011. The median patient age at the time of the procedure was 12 months (range, 25 days to 25 months), and the median body weight was 9.1 kg (range, 4.3 to 15 kg). Two patients had multiple ventricular septal defects (VSDs; additional perimembranous VSD in 1 patient and multiple MVSDs in the other) and 3 patients had associated cardiac anomalies; complete transposition of the great arteries in 1 patient and an atrial septal defect in 2 patients. All the procedures were performed on beating hearts, exception in 1 case. The ADO selected for the aortic side was at least 1 to 2 mm larger than the largest VSD in the left ventricle side. Results: The procedure was successful in all patients and each device was well positioned. During the median follow-up of 2.4 years, a small residual VSD was noted in 2 patients who had multiple VSDs and no leakage was seen in the other 3 patients. Conclusion: Perventricular closure of MVSD with an ADO is a good option for patients with apical MVSD. However, careful manipulation is important, especially in the case of small infants.

게임의 근접전투에서 카메라 샷을 적용한 오클루젼 해결 기법 (An Occlusion Resolution Technique Applying Camera Shots in Close Quater Combat of the Game)

  • 김방울;조경은;엄기현
    • 한국게임학회 논문지
    • /
    • 제11권2호
    • /
    • pp.105-114
    • /
    • 2011
  • MMORPG와 같은 게임에서 근접전투가 벌어지는 샷에서 프라이머리 액터들간의 오클루젼이 종종 발생한다. 본 논문은 미디엄 샷(medium shot) 기법으로 오클루젼을 해결하고 오버-숄더 샷(over-shoulder shot) 기법으로 대결구도를 강화하는 미디엄 오버-숄더(Medium and Oversholder, MOS) 기법을 제안한다. 미디엄 샷 기법은 4개의 기준점을 설정하고. 오버-숄더 샷 기법은 측면의 기준점을 가변적으로 위치시키며 오클루더는 두 개의 스피어로 대체한다. 레이와 스피어가 교차하는지 여부로 잠재적 오클루젼 상태가 판별되면 오클루더의 우측 또는 좌측으로 카메라를 이동시키고, 오클루젼이 해결되면 이동을 멈춘다. 실험결과 MOS 기법은 샷당 평균 $13.7{\mu}s$ 의 연산시간의 성능을 보였으며, 오클루젼은 평균 9.26% 비율로 뷰어의 시선 장애에 영향을 주진 않았다.

37마리 개의 동맥관 개존증의 임상소견과 비외과적 치료의 회고연구 (Retrospective Study of Patent Ductus Arteriosus in 37 Dogs: Clinical Presentations and Interventional Therapy)

  • 박종인;최란;이승곤;현창백
    • 한국임상수의학회지
    • /
    • 제30권2호
    • /
    • pp.87-94
    • /
    • 2013
  • 본 회고 연구에서는 동맥관 개존증에 이환된 개에서 심장중재술을 통한 치료증례의 임상적 특징과 치료예후를 조사하였다. 환축의 구성을 보면, 말티스와 암컷이 차지하는 비중이 컸다. Bounding pulse와 좌심저부의 심잡음이 가장 대표적인 신체검사 소견이며, differential cyanosis은 매우 드물게 관찰되었다. 심전도상 특징은 좌심종대소견과 동성빈맥이였다. 흉부방사선상 좌심실 종대와 대동맥 확장을 동반한 triple bumps가 대표적인 소견이 였다. 심초음파상 특징은 좌심실 종대를 동반한 폐동맥 단축단면상 심각한 와류 소견이였으며, 다수의 환자에서 이첨판 역류 소견도 관찰되었다. 37증례 중 32증례에서 thromboemolic coils (TCE)이나 Amplatz canine ductal occluder (ACDO)를 이용한 심장 중제술적 치료가 실시되었다. 일시적인 혈색소뇨가 관찰되었고 장착된 코일이나 ACDO가 이탈되는 부작용이 확인되었다. 하지만 장기 관찰이 가능했던 29증례에서 특별한 부작용은 관찰되지 않았다.

경피적 카테타 동매관 폐쇄술후 발생한 용혈 (Hemolysis after PDA Unbrella Occlusion; Surgical Treatment)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • 제26권11호
    • /
    • pp.890-893
    • /
    • 1993
  • The first successful percutaneous transcatheter occlusion technique for patent ductus arteriosus achived by Rashkind in 1977.Transcatheter occlusion with the Rashikind double umbrella device is now widely accepted as treatment for patent ductus arterisus. The reported complications include embolization of the device, psudocoarctation left pulmonary artery stenosis, residual shunts, and mechanical hemolysis. We report two cases of severe hemolysis after occlusion of PDA with Rashkind occluder.

  • PDF

그림자 아틀라스를 이용한 부드러운 그림자 생성 방법 (Real-time Soft-shadow using Shadow Atlas)

  • 박선용;양진석;오경수
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제17권2호
    • /
    • pp.11-16
    • /
    • 2011
  • 컴퓨터 그래픽스에서 그림자는 그림자 자체로서 뿐 아니라 장면 내 물체들 간의 거리감에 대한 단서를 제공함으로써 사실감 제고 측면의 매우 중요한 역할을 한다. 그림자를 표현하기 위한 전통적인 방법으로 그림자 매핑이나 그림자 볼륨 등의 기법들이 사용되지만 점광원(point light)을 가정하므로 결과가 자연스럽지 못하다. 반면, 면광원(area light)을 사용할 경우 부드러운 그림자를 생성하므로 좀 더 사실적인 그림자 표현이 가능하지만 광원면(light source surface) 전체에 대한 적분을 요구하기 때문에 계산비용이 매우 비싸다. 이러한 단점을 극복하기 위해 차폐물(occluder)의 광원으로의 역투사(back-projection)나 반영(penumbra)의 크기 계산을 통한 필터링 등 여러 방안들이 소개되었지만 낮은 수준(order)의 근사로 인한 누광(light bleeding)이나 물결현상(ringing effect), 그리고 성능저하 등의 문제가 발생한다. 본 논문에서는 그림자 아틀라스(shadow atlas)를 이용하여 이러한 문제들을 개선하는 방법에 대하여 기술한다.

외상성 심실중격결손 수술 후 잔존하는 심실중격결손에 대한 중재적 심도자술을 이용한 폐쇄 (Transcatheter Closure of a Residual Shunt after Surgical Repair of Traumatic Ventricular Septal Defect)

  • 정희정;임한혁;유재현;이재환;길홍량
    • Clinical and Experimental Pediatrics
    • /
    • 제48권10호
    • /
    • pp.1143-1143
    • /
    • 2005
  • 흉부 관통상에 의해 심실중격결손이 동반된 대부분의 환자들은 내원 시 활력징후가 불안정하여 심폐소생술 및 응급 개흉술을 시행받게 되는데, 이러한 경우 심장과 흉부 손상의 위치 및 정도에 대한 자세한 검사가 이루어지지 않은 상태이므로 발견되지 않았거나 잔존하는 이상 소견들이 수술 후 검사에서 발견될 수 있고 이에 대한 재수술을 필요로 하는 경우도 있다. 심실중격결손의 심도자술을 통한 폐쇄는 수술을 대처할 수 있는 방법으로서, 특히 수술 후 잔존하는 단락의 경우 이차 수술의 위험을 피할 수 있다. 저자들은 흉부 자상에 의한 심실벽의 열창 및 심실중격결손을 수술적 방법으로 봉합한 후 잔존하는 심실중격결손을 기구($Amplatzer^{(R)}$ VSD occluder)를 이용한 중재적 심도자술로 치료한 증례를 문헌 고찰과 함께 보고한다. 심도자술 6개월 후 시행한 심초음파검사에서 잔존하는 심실 좌우 단락은 없었고, 심실 크기와 기능도 정상이었고, 현재 상태는 양호하여 정상적으로 학교생활을 하고 있다.