• Title/Summary/Keyword: oblique drop

Search Result 10, Processing Time 0.03 seconds

Analysis on Biomechanical Differences in Lower Limbs Caused by Increasing Heart Rates During Drop-landing (드롭랜딩 시 심박수 증가에 따른 하지의 생체역학적 차이 분석)

  • Hong, Wan-Ki;Kim, Do-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • Objective : This study aimed to understand how increased heart rates at the time of drop landing during a step test would affect biomechanical variables of the lower extremity limbs. Background : Ballet performers do more than 200 landings in a daily training. This training raises the heart rate and the fatigability of the lower extremity limbs. Ballet performance high heart rate can trigger lower extremity limb injury. Method : We instructed eight female ballet dancers with no instability in their ankle joints(mean ${\pm}$ SD: age, $20.7{\pm}0.7yr$; body mass index, $19.5{\pm}1.2kg/m^2$, career duration, $8.7{\pm}2.0yr$) to perform the drop landing under the following conditions: rest, 60% heart rate reserve (HRR) and 80% HRR. Results : First, the study confirmed that the increased heart rates of the female ballet dancers did not affect the working ranges of the knee joints during drop landing but only increased angular speeds, which was considered a negative shock-absorption strategy. Second, 80% HRR, which was increased through the step tests, led to severe fatigue among the female ballet dancers, which made them unable to perform a lower extremity limb-neutral position. Hence, their drop landing was unstable, with increased introversion and extroversion moments. Third, we observed that the increasing 80% HRR failed to help the dancers effectively control ground reaction forces but improved the muscular activities of the rectus femoris and vastus medialis oblique muscles. Fourth, the increasing heart rates were positively related to the muscular activities of the vastus medialis oblique and rectus femoris muscles, and the extroversion and introversion moments. Conclusion/Application : Our results prove that increased HRR during a step test negatively affects the biomechanical variables of the lower extremity limbs at the time of drop landing.

A Study on the Dynamic Behaviors of a Shipping Container Under Drop Impact Loading (낙하충격하중을 받는 방사성물질 수송용기의 동적거동에 관한 연구)

  • 이영신;김용재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2805-2816
    • /
    • 1994
  • This paper describes dynamic finite element analyses performed to study the dynamic behaviors of a shipping container under the impact onto rigid target due to the accidental fall from the hight of 9 m. Using two and three dimensional techniques, the shipping container which gave the maximum damage, ten different drop orientations are considered ; at intervals of $5^{\circ}$ from $45^{\circ}$ to $90^{\circ}$ According to the present results, the orientation of the shipping container which gave the maximum damage is $85^{\circ}$ from horizontal for oblique drop in the primary impact. In the optimal design of the shipping container, the impact limiter material must be considered importantly because it's proper selection affects the weight and the manufacturing cost of the shipping container. The analysis of the shipping container in this paper demonstrated that the shipping container is structurally sound relative to the regulatory drop test requirements.

Fracture mechanics analysis of multipurpose canister for spent nuclear fuels under horizontal/oblique drop accidents

  • Jae-Yoon Jeong;Cheol-Ho Kim;Hune-Tae Kim;Ji-Hye Kim;Yun-Jae Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4647-4658
    • /
    • 2023
  • In this paper, elastic-plastic fracture mechanics analysis is performed to determine the critical crack sizes of the multipurpose canister (MPC) manufactured using austenitic stainless steel under dynamic loading conditions that simulate drop accidents. Firstly, dynamic finite element (FE) analysis is performed using Abaqus v.2018 with the KORAD (Korea Radioactive Waste Agency)-21 model under two drop accident conditions. Through the FE analysis, critical locations and through-thickness stress distributions in the MPC are identified, where the maximum plastic strain occurs during impact loadings. Then, the evaluation using the failure assessment diagram (FAD) is performed by postulating an external surface crack at the critical location to determine the critical crack depth. It is found that, for the drop cases considered in this paper, the principal failure mechanism for the circumferential surface crack is found to be the plastic collapse due to dominant high bending axial stress in the thickness. For axial cracks, the plastic collapse is also the dominant failure mechanism due to high membrane hoop stress, followed by the ductile tearing analysis. When incorporating the strain rate effect on yield strength and fracture toughness, the critical crack depth increases from 10 to 20%.

Prediction of Dynamic Stability Derivatives Using Unsteady Euler Equations (비정상 Euler 방정식을 이용한 동안정 미계수 예측)

  • Park Soo Hyung;Kim Yoonsik;Kwon Jang Hyuk
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.78-84
    • /
    • 2001
  • A dual-time stepping algorithm combined with a parallelized multigrid DADI method is presented to predict the dynamic damping coefficients. The Basic Finner model is chosen to validate the prediction capability of the present unsteady Euler method. The linearity of the pitch- and roll-damping coefficients is shown in the low angular rates and the interesting large drop and stiff increment in transonic region for roll-damping coefficients are explained in detail. Through the analysis for the pressure distributions at Mach number 1.0 to 1.2, the sudden drop results from the normal shock and the stiff increment of roll-damping reflects the transition of the normal shock to the oblique shock. The results also show that the Euler equations can give the damping coefficients with a comparable accuracy.

  • PDF

An Numerical Study on the Flow Uniformity and Pressure Drop in Dual Monolith Catalytic Converter during the Rapid Acceleration/Deceleration Driving (급가감속 운전에 따른 듀얼 모노리스형 촉매변환기 내의 유동 균일도와 압력 강하에 관한 수치적 연구)

  • Kim, Young-Deuk;Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.63-71
    • /
    • 2007
  • The conversion efficiency, durability and pressure drop of the automotive exhaust catalysts are dependent on the flow distribution within the substrate. Conventional porous medium approaches assuming monolith resistance based on the one-dimensional laminar flow for simulating the flow through the automotive exhaust catalysts over-predict the flow uniformity in the monolith. In this study, additional pressure loss is also considered by accounting for entrance effects due to the oblique flow incident on the front face of monolith as a consequence of flow separation and recirculation within the diffuser. The incorporation of an additional pressure loss improves the predictions for the maximum flow velocity within the substrate. An numerical study has also been conducted for the three-dimensional unsteady incompressible non-reacting flow inside various dual-monolith catalytic converters for the rapid acceleration/deceleration driving.

Formulation on the Empirical Equation of the Cask Impact Forces by Dimensional Analysis (차원해석을 이용한 사용후 핵연료 수송용기의 충격력 실험식 공식화)

  • Kim Yong-Jae;Choi Young-Jin;Lee Young-Shin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.3
    • /
    • pp.245-254
    • /
    • 2005
  • Radioactive material is used in the various fields. The numbers of transport for radioactive material have been gradually increased in both domestic and International regions. The safety of the cask should be secured to safely transport of radioactive material. The korean atomic law and the IAEA safety standards prescribe regulations lot the safe transport of radioactive material The cask for spent fuel is comprised of the body and the impact limiter. In this study, the empirical equation of the cask impact force is proposed based on the dimensional analysis. Using this empirical equation the characteristics of the impact limiter are analyzed. The results are also validated by comparing with the previous results of the impact area method and the finite element analysis. The present method can be used to predict the impact force of the cask.

Hybrids of Au nanodishes and Au nanoparticles

  • Son, Jin Gyeong;Han, Sang Woo;Lee, Tae Geol;Wi, Jung-Sub
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.228.1-228.1
    • /
    • 2015
  • We demonstrate a simple route to hybridize two different nanomaterials by using three-dimensional nanodishes that can be used as small plasmonic containers to host guest nanoparticles. Our nanodishes were fabricated using nanoimprint lithography and oblique-angle film deposition, and the guest nanoparticles were drop-casted onto the host nanodishes. Based on the proposed method, colloidal Au nanoparticles were assembled inside Au nanodishes in the form of a labyrinth. These Au nanoparticle-nanodish hybrids excited a strong surface plasmon resonance, as verified by a numerical simulation of the local field enhancement and by direct observation of the enhanced Raman signals. Our results point to the potential of the nanodishes as a useful platform for combining diverse nanomaterials and their functionalities.

  • PDF

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF

Effect of Active Foot Arch Support on Lower Extremity Electromyographic Activity during Squat Exercise in Persons with Pronated Foot (회내족 대상자의 스쿼트 동안 능동적 족궁 지지가 하지근육의 근전도 활성도에 미치는 영향)

  • Nam, Ki-Seok;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.57-61
    • /
    • 2010
  • Purpose: The purpose of this study was to identify the effect of active foot arch support on the muscles of lower extremity electromyographic activity during squat exercise in persons with pronated foot. Methods: The study subjects were 16 persons with pronated foot. They have no history of surgery in lower extremity and trunk and limitation of range of motion or pain when performing squat exercise. Each subject was measured the navicular drop (ND) to determine the pronated foot. And then the subjects were asked to perform three repetitions of a $90^{\circ}$ knee flexion squat in both conditions which are 1) preferred squat and 2) squat with active foot arch support. Results: Paired t-test revealed that squat with active foot arch support produced significantly greater EMG activities in abductor hallucis (p=0.00), proneus longus (p=0.03) and gluteus medius (p=0.04) than preferred squat. But the EMG activities of tibialis anterior, vastus medialis oblique and vastus lateralis were not showed significantly different between the both squat conditions. Conclusion: The findings of this study suggest that active foot arch support during squat increase the activities of lower extremity muscles which are the abductor hallucis, proneus longus and gluteus medius. Also, the abductor hallucis which is one of the planter intrinsic muscle and peroneus longus play a role in support of the foot arch and active foot arch support induced the increase of the activity of gluteus medius. Therefore active foot arch support can change the lower extremity biomechanics as well as passive foot support such as foot orthotics and taping.

Performance of Oscillating Water Column type Wave Energy Converter in Oblique Waves (사파중 진동수주형 파력발전장치의 성능평가)

  • Jin, Jiyuan;Hyun, Beom-Soo;Hong, Keyyong;Liu, Zhen
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.182-188
    • /
    • 2014
  • In an oscillating water column (OWC)-type wave energy conversion system, the performance of the OWC chamber depends on the chamber shape, as well as the incident wave direction and pressure drop produced by the turbine. Although the previous studies on OWC chambers have focused on wave absorbing performance in ideal operating conditions, incident waves do not always arrive normally to the OWC chamber in real sea conditions, especially in fixed devices. The present study deals with experiments and numerical calculations to investigate the effects of wave direction on the performance of the OWC chamber. The experiments were carried out in a three-dimensional wave basin for five different wave directions, including the effect of turbine using the corresponding orifice. The wave elevation inside the chamber was measured at the center point under various incident wave conditions. The numerical study was conducted by using a numerical wave tank-based volume-of-fluid model to compare the results with experimental data and to reveal the detailed flows around the chamber.