• 제목/요약/키워드: objective measurement

검색결과 1,917건 처리시간 0.035초

인삼세척기 내부유동장의 PIV계측 및 유동특성 (PIV Measurement and Flow Characteristics of Internal Flow Field within Ginseng Washing Machine)

  • 나은수;송치성
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.59-65
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry)to high_speed flow characteristics within Ginseng washing machine. Three different kinds of flow rate(15,20,27 $\ell$/min)are selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Instantaneous velocity distribution, time-mean velocity distribution and velocity profiles are represented quantitatively at the full-scale region for the deeper understanding of the flow characteristics in Ginseng washing machine.

  • PDF

식물성장 분석을 위한 시스템 소프트웨어 개발 (The Development of the System Software for Analysis of Plant's Growth)

  • 전성동;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.299-303
    • /
    • 2003
  • We research hardware and software for measurement of most suitable condition of the plant growth. that is put of the future oriented that plant growing system. The environment cannot offer the most suitable condition of the plant growth. so we are approached most suitable condition of the plant growth by adjustment of artificial condition of the plant growth but in theses experiment includes some fault that is subjectivity of observation. therefor we develop vision equipment and software for objective observation measurement.

  • PDF

속중성자선의 선량분포에 관한 연구 (Fast Neutron Beam Dosimetry)

  • 이효남;지영훈;지광수;이동한
    • 대한방사선치료학회지
    • /
    • 제9권1호
    • /
    • pp.71-81
    • /
    • 1997
  • I. Objective and Importance of the Project We have been using MC-50 cyclotron and NT-50 neutron therapy machine for treating cancer patients since 1986 at Korea Cancer Center Hospital. It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine (Task Group 18), European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induce the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. II. Scope and Contents of the Project For establishing a unique technique of measurement and inventing a standard method of measurement of fast neutron beam, 1. to grasp the physical characteristics of neutron therapy machine 2. to study the principles for measrement of fast neutron beam 3. to get the dose distribution (dose rate, percent-depth dose, flatness etc) throught the actual measurement 4. to compare our data with those being cited world-widely.

  • PDF

줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구 (A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position)

  • 김문환;윤성준;하성민
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

작업환경측정 신뢰성평가제도 개선방안에 관한 연구 (tudy on the Improvement of Reliability Assessment of Work Environment Measurement in Korea)

  • 황규석
    • 한국산업보건학회지
    • /
    • 제29권1호
    • /
    • pp.50-56
    • /
    • 2019
  • Objective: The aim of this study is to analyze the reliability assessment of work environment measurement, and to propose ways of improving the system. Methods: We have reviewed reports and articles on the reliability assessment written by KOSHA and academia in order to analyze problems related with the system and propose the alternatives. Results: There are three ways to improve the system of the reliability assessment. First of all, it is necessary to perform the reliability assessment by measuring the work environment when workers raise questions about the results so we can make workers trust these results of the reliability assessment. Secondly, we should inspect the workplace at first, not the work environment service provider, so we can increase the employer's recognition of his duty to practice the work environment measurement. Thirdly, the technical committee is needed for technical issues related with the work environment measurement. Conclusions: Above all, it is crucial to get the workers' interest and trust to improve the work environment measurement. The reliability assessment should support the meaning and value of the work environment measurement by practicing the reliability assessment whenever workers have a demand for this and operating the technical committee.

미곡(米穀)의 상온통풍건조(常温通風乾燥)를 위한 컴퓨터 계측(計測) 및 제어(制御)시스템 개발 (Development of a Computer Measurement and Control System for Rough Rice Drying by Natural Air)

  • 김태곤;장동일;김만수
    • Journal of Biosystems Engineering
    • /
    • 제13권4호
    • /
    • pp.46-55
    • /
    • 1988
  • The objective of this study was to develop a computer measurement and control system which enable it possible to manage the natural air rough rice drying and storage properly and safely. The following contents of work were taken in this study in order to fulfill the above goal: 1) Design and construction of measurement system which can measure the rough rice drying conditions automatically and transfer them to computer system for data processing. 2) Development of a management software which can determine the need of fan operation by the analysis of drying and/or storage conditions. 3) Design and construction of a control system which deliver the computer decision of fan operation and make it on and off. 4) Technical and economical analysis of the computer measurement and control system development by the comparison experiments of the computer management and of the manual.

  • PDF

선형홀센서를 이용한 전기식 구동장치의 속도 신호 구현 (A New Velocity Measurement Method using Linear Type Hall-effect Sensor for Electro-mechanical Fin Actuator)

  • 구정회;송치영
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.70-75
    • /
    • 2010
  • The objective of this paper is to propose a new velocity measurement method for an electro-mechanical fin actuator. The model of the electro-mechanical fin actuator includes uncertainties such as unknown disturbances and parameter variations in flight condition. So, an electro-mechanical fin actuator system needs robust control algorithm which requires not only position information but also velocity information. Usually, analog tachometers have been used for velocity feedback in an electro-mechanical fin actuator. However, using these types of sensors have problems such as the cost, space, and malfunction. These problems lead to propose a new velocity measurement method using linear type Hall-effect sensor. In order to verify the proposed method, several experiments are performed using Model Following Sliding Mode Controller(MFSMC). It is shown that the MFSMC with a new velocity measurement method using linear type Hall-effect sensor can satisfy the requirements without using of velocity sensor.

ECONOMIC DESIGN OF SCREENING PORCEDURES CONSIDERING INSPECTION ERRORS

  • Kim, Young-Jin
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2006년도 추계학술대회
    • /
    • pp.365-368
    • /
    • 2006
  • The implementation of a screening procedure for removing non-conforming products has become a common practice especially in high-tech manufacturing industries. Screening procedures involve a measurement on the quality characteristic of interest since decisions regarding the conformance to specifications are usually made on the basis of the realization of measurement. A significant variability in measurement procedures may result in the misclassification of an outgoing product (that is, falsely accepting defectives or falsely rejecting conforming items), which may lead to wrong interpretation on product quality, It may thus be necessary to consider the impacts of misclassification errors due to measurement variability when designing screening procedures. Along this line, this article investigates the design of screening procedures based on the assessment of misclassification errors. The main objective is to determine the screening limits on measured values so that two types of misclassification errors may properly be compromised.

  • PDF

Nonlinearity-Compensation Extended Kalman Filter for Handling Unexpected Measurement Uncertainty in Process Tomography

  • Kim, Jeong-Hoon;Ijaz, Umer Zeeshan;Kim, Bong-Seok;Kim, Min-Chan;Kim, Sin;Kim, Kyung-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1897-1902
    • /
    • 2005
  • The objective of this paper is to estimate the concentration distribution in flow field inside the pipeline based on electrical impedance tomography. Special emphasis is given to the development of dynamic imaging technique for two-phase field undergoing a rapid transient change. Nonlinearity-compensation extended Kalman filter is employed to cope with unexpected measurement uncertainty. The nonlinearity-compensation extended Kalman filter compensates for the influence of measurement uncertainty and solves the instability of extended Kalman filter. Extensive computer simulations are carried out to show that nonlinearity-compensation extended Kalman filter has enhanced estimation performance especially in the unexpected measurement environment.

  • PDF

볼바 시스템을 이용한 기상측정오차 보정 (On-Machine Measurement Error Compensation Using Ball-bar System)

  • 이세희;서태일;조명우
    • 한국공작기계학회논문집
    • /
    • 제10권2호
    • /
    • pp.56-63
    • /
    • 2001
  • The objective of this research is to develop a measurement error compensation method for On-Machine Measurement (OMM) process based on a closed-loop configuration. Geometric errors of vertical machining center are measured using ball-bar system, and probing errors are measured using master ball. The errors are represented using homogeneous trans-formation matrices and the closed-loop configuration method is applied to calculate 3-dimensional errors. To verify the effectiveness of the method proposed in this research, compensated results are compared to the data using CMM process, and the results are analyzed. The results show the proposed method can be applied in OMM process to make the measured data more reliable.

  • PDF