• Title/Summary/Keyword: objective measure

Search Result 1,798, Processing Time 0.033 seconds

A Study on Objective Speech Quality Measure under CDMA Telephone Networks Environment (CDMA 통신망에서의 객관적 음질 평가 척도에 관한 연구)

  • 김광수;김민정;석수영;정호열;정현열
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.4
    • /
    • pp.53-58
    • /
    • 2001
  • In this paper to develop objective speech quality measure for CDMA telephone network environments, recent developed measures are investigated first. But those measures show low performances in CDMA telephone networks. To solve this problem, new objective speech quality measure adopting noise masking threshold is proposed and studied. To acquire better performance, scaled noise masking threshold calculation for speech signals is employed instead of conventional tone signals. To verify effectiveness of proposed method performance comparison experiments are carried out for CDMA telephone network speech databases, for the results proposed methods show improved performances compared to existing meaures.

  • PDF

An Objective Speech Quality Measure using Masking Effect under Digital Mobile Telephone Network Environment (디지털 이동통신망 환경 하에서 마스킹 효과를 이용한 객관적 음질 평가 척도)

  • 김광수;김민정;석수영;정호열;정현일
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.4
    • /
    • pp.405-414
    • /
    • 2002
  • In this paper, we propose a new objective speech quality measure using noise masking threshold for speech quality assessment of mobile telephone network environments, and verify the effectiveness of the proposed method through the experiments. For such a purpose, well known objective speech quality measures such as BSD and PSQM are first evaluated for digital mobile telephone network environments. However, these conventional methods does not have good performance under mobile networks environments compared to literary results. To be mote effective objective speech quality measure under mobile telephone environments, the proposed method employs human psychoacoustic masking effect. The DMOS, instead of MOS, is used as a subjective speech quality measure for performance evaluation. The performance comparison are carried out with speech data collected from digital mobile telephone environments. As results, the proposed measure have and average 4% higher performance, in terms of correlation, than existing objective speech quality measures such as BSD and PSQM.

  • PDF

A Study on the Comparison of Digital Speech Coding Performance (디지털 음성방식의 성능 비교에 대한 연구)

  • 배철수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.8
    • /
    • pp.881-890
    • /
    • 1992
  • Resonable speech quality assessment methodologies are required for speech quality assessment model which is used at speech system and communication network. There are objectlve measuies and subjective measures and subjective measure has the variousproblems in speech quality assessment methodologies. The objective of this study is to compare objective measures with subjective measure and obtain the objective measure as close as possible to subjective measure.

  • PDF

Correlation Analysis of PESQ and MOS Evaluation for HMM-based Synthetic Korean Speech (HMM 기반의 한국어 합성음에 대한 PESQ 및 MOS 평가의 상관도 분석)

  • Lin, Cang-Song;Bae, Keun-Sung
    • Phonetics and Speech Sciences
    • /
    • v.2 no.1
    • /
    • pp.71-75
    • /
    • 2010
  • The PESQ is an objective speech quality evaluation measure that is known to have a high correlation with a subjective speech quality measure such as MOS. To examine whether it could be useful as an objective quality measure of synthetic speech, we carried out both subjective evaluation tests with MOS and DMOS and an objective evaluation test with PESQ for HMM-based Korean synthetic speech signals and analyzed the correlation between them. Experimental results have shown that the PESQ has correlations of 0.87 with MOS and 0.92 with DMOS. It means that the PESQ holds much promise for evaluating the quality of synthetic Korean speech.

  • PDF

Speech Quality Measure in a Mobile Communication System Using PLP Cepstral Distance with CMS (심리 음향 켑스트럼 평균 차감법을 이용한 이동 전화망에서의 음질 평가)

  • Yun, J.J.;Park, S.W.;Park, Y.C.;Youn, D.H.;Cha, I.H.
    • Speech Sciences
    • /
    • v.6
    • /
    • pp.163-179
    • /
    • 1999
  • For the set up, management and repair of a mobile communication system, continuous estimation of speech quality is required. Speech quality measurement can be conducted by listener's judgement in a subjective test such as MOS (Mean Opinion Score) test. However, this method is laborious, expensive and time-consuming, it is advisable to predict subjective speech quality via objective measures. This paper presents a robust objective speech quality measure, PLP-CMS (Perceptual Linear Predictive-Cepstral Mean Subtraction), which can predict subjective speech quality in mobile communication systems. PLP-CMS has a high correlation with subjective quality owing to PLP (Perceptual Linear Predictive) analysis and shows a robust performance not being influenced by PSTN (Public Switched Telephone Network) channel effects due to CMS (Cepstral Mean Subtraction). To prove the performance of our proposed algorithm, we carried out subjective and objective quality estimation on speech samples which are variously distorted in a real mobile communication system. As a result, we demonstrated that PLP-CMS has a higher correlation with subjective quality than PSQM (Perceptual Speech Quality Measure) and PLP-CD (Perceptual Linear Predictive-Cepstral Distance).

  • PDF

Calculation of Objective Quality-Evaluation-Index for Mosaic Imagery (모자이크 영상의 객관적 품질평가지수 산정 방법)

  • Woo, Hee-Sook;Noh, Myoung-Jong;Park, June-Ku;Cho, Woo-Sug;Kim, Byung-Guk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.3
    • /
    • pp.33-40
    • /
    • 2009
  • This paper proposes the assessment method for objective quality-evaluation-index of mosaic images. Quality assessment was evaluated using seam-line method and similarity and contrast of adjacent images. The evaluation measure was calculated based on selected evaluation criteria and compared with human visual inspection. It was found that quantitative quality evaluation measure showed that the evaluation results were similar to human visual check. Conclusively experimental results proved that proposed evaluation measure could be used for quantitative and objective quality assessment of mosaic images.

  • PDF

Correlations Among Objective Measurements of Spasticity in Patients With Brain Lesions

  • Kim, Yong-Wook
    • Physical Therapy Korea
    • /
    • v.14 no.4
    • /
    • pp.7-13
    • /
    • 2007
  • The purpose of this study was to investigate correlations among objective measurements of spasticity in patients with brain lesions. Thirty-two stroke and traumatic brain injury subjects participated in the study. Spasticity was quantified using the knee first flexion angle, relaxation index obtained from a pendulum drop test, and the amplitude of a knee tendon reflex test. Pearson's product correlation coefficient was used to examine relationships among these measurements of spasticity. There was a significant positive correlation between the relaxation index and knee first flexion angle in patients with brain lesions (r=.895, p<.01). There was also significant negative correlation between the amplitude of knee tendon reflex and relaxation index (r=-.612, p<.01), and between amplitude and knee first flexion angle (r=-.537, p<.01). Thus, it is possible to use the knee first flexion angle as an objective measure of spasticity, rather than relaxation index, which is more complicated to obtain. Further studies are needed to explore the effects of functional improvement and long-lasting carryover effects of spasticity using a simple objective measure such as the knee first flexion angle from a pendulum test.

  • PDF

Asynchronous Waste: An Alternative Performance Measure for Pull Production Control System

  • Kim, ll-hyung
    • Management Science and Financial Engineering
    • /
    • v.6 no.1
    • /
    • pp.37-63
    • /
    • 2000
  • An important objective of pull-based production control is to achieve synchronized and smooth production flow in a multi-stage system that is subject to uncertainty. To our knowledge, previous research has not generated a performance measure that captures this objective of pull-based probased production control system. This performance material with respect to the instant when the operation is required. We examine the issue of asynchronous waste in a two-stage kanban control system.

  • PDF

A Multi-Objective Genetic Algorithm Approach to the Design of Reliable Water Distribution Networks

  • T.Devi Prasad;Park, Nam-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2002.05b
    • /
    • pp.829-836
    • /
    • 2002
  • The paper presents a multi-objective genetic algorithm approach to the design of a water distribution network. The objectives considered are minimization of network cost and maximization of a reliability measure. In this study, a new reliability measure, called network resilience, is introduced. This measure mimics a designer's desire of providing excess power at nodes and designing reliable loops with practicable pipe diameters. The proposed method produces a set of Pareto-optimal solutions in the search space of cost and network resilience. Genetic algorithms are observed to be poor in handling constraints. To handle constraints in a better way, a constraint handling technique that does not require a penalty coefficient and applicable to water distribution systems is presented. The present model is applied to two example problems, which were widely reported. Pipe failure analysis carried out on some of the solutions obtained revealed that the network resilience based approach gave better results in terms of network reliability.

  • PDF

A Study on Objective Quality Assessment for Synthesized speech by Rule (규칙합성음의 객관적 품질평가에 관한 연구)

  • 홍진우;김순협
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.10
    • /
    • pp.42-49
    • /
    • 1993
  • In this paper, we evaluate the quality of synthesized speech by rule using the LPC CD as a objective measure, and then compare the test result with the subjective one. Speech used for the test consists of 108 words which are selected by word construction method using Korean attribute and frequency distribution, synthesized by demi-syllable rule. By evaluating the quality of synthesized speech by reule objectively, we have tried to resolve the problems such as lots of evaluation time, expansion of test scale, and variables of analysis result arised by subjective measure. We have, also, proved the validity of the objective test using the LPC CD, by comparing intelligibility which is the index for the subjective quality evaluation of synthesized speech by rule with MOS. From this results, we can provide a guide for quality assessment that would be useful in the R&D of synthesis method and the commercial products using synthesized speech.

  • PDF