• Title/Summary/Keyword: numerical D/B

Search Result 732, Processing Time 0.038 seconds

3-D Numerical Simulation of Open-Channel Flows over Smooth-Rough Bed Strips (매끄러운 하상-거친 하상의 횡방향 연속구조를 갖는 개수로 흐름의 3차원 수치모의)

  • Choi, Sung-Uk;Park, Moonhyeong;Kang, Hyeongsik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.573-581
    • /
    • 2006
  • This paper presents a turbulence modeling of the open-channel flows over smooth-rough bed strips. A Reynolds stress model is used for the turbulence closure. The simulated mean flow and turbulence structures are compared with the previously reported experimental data. Comparisons reveal that the developed Reynolds stress model successfully predicts the mean flow and turbulence structures of open-channel flows over smooth-rough bed strips. The computed flow vectors show cellular secondary currents, of which the upflow occurs over the smooth bed strip and the downflow over the rough bed strip. It is found that the cellular secondary currents affect the mean flow and turbulence structure. A budget analysis of the streamwise vorticity equation is also carried out to investigate the mechanism by which the secondary currents are generated.

Development of 2D Finite Element Model for the Analysis of Shallow Water Flow (천수흐름 해석을 위한 2차원 유한요소모형의 개발)

  • Seo, Il Won;Song, Chang Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2B
    • /
    • pp.199-209
    • /
    • 2010
  • A finite element model for analyzing surface water flow was developed. Shallow water equation was discretized and solved by Galerkin and Newton-Raphson method. Triangular or rectangular elements can be mixed together to construct meshes. The algebraic equation was solved by frontal method which is very efficient in finite element problem. The developed model was applied to rectangular meandering channel with two bends and transverse velocities and water depth distributions were examined. High velocity was located near the inner bank at the apexes of the bends and velocity distribution was symmetrical about the centerline at the midsection of two bend and super elevation also occurred. Simulation results showed very good agreement with measured data. Another numerical simulation was carried out in mild, steep, adverse and abrupt bottom change slope and channels with weir. 12 water surface profiles of gradually varied flow were correct in terms of hydraulic interpretation.

A design of the microstrip phased array antenna with the slot-coupled structure for the base station of mobile communication (슬롯결합구조를 갖는 이동통신 기지국용 마이크로스트립 위상배열 안테나의 설계)

  • 장정필;장병준;윤영중;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3205-3214
    • /
    • 1996
  • In this paper, the microstrip phased array antennas with coupling-slots for the base station of mobile communication is proposed and anlyzed with accurate analysis method which is based on both reciprocity principle and full-wave analysis. The basis functions used for the numerical analysis are determined depending upon the accuracy, convergence properties of the solution, and the computation time. The patch uses 3 EB mode and the slot uses IPWS mode. The designed phased array antenna has 8 slot-coupled microstrip patch array elements and the beam scanning capability is obtained by using the 4-bit PIN-diode phase shifters as switching devices which are consisted of the loaded line phase shifters for 30.deg. and 60.deg. and the reflection type phase shifters for 90.deg. and 180.deg. repectively. The 4-bits phase shifters which aremade by connecting each phase shifter have about 2.deg.-3.deg. phase errors and their insertion loss are about 3dB for each phase state. The fabricated 8-element phased array antenna with 4-bits phase shifters provides 12.deg.-14.deg. beamwidths depending on the scanning angle and is capable of scanning its beam to .+-.45.deg. with 9.deg. intervals, and the gain 12dBi. The overall results show that the slot-coupled phased array antenna has great advantages of wideband, high gain and reduced spurious radiation. Also, the antenna can be made small and thin. Furthermore, the scanning property of this antenna allows for its application in several areas, such as mobile communication system and PCS.

  • PDF

A study on characteristics of the autonomic nervous system in students with Keongke - Using Heart Rate Variability and Pupil Size Variability - (경계(驚悸) 증상을 지닌 학생 집단의 자율 신경 기능 특성에 대한 연구 - 심박변이도와 동공크기 변이도를 중심으로 -)

  • Lee, Seung-Gi;Lee, Jeong-Chan;Kim, Ji-Eun;Park, Kyung-Mo;Kang, Hee-Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.17 no.2
    • /
    • pp.133-145
    • /
    • 2006
  • Objective : The purpose of this experimental-controlled study was to investigate the characteristics of the autonomic nervous system in students with Keongke by using HRV(Heart rate variability) and PSV(Pupil size variability). Method : The study group was consisted of 11 students with self recognition as the experimental group, and 25 normal students as the control group. Informations on gender and age were obtained by medical charts and personal interviews. By using heart rate variability and pupil size variability, we measured the value of HRT(Heart rate), SDNN(Standard deviation of NN intervals), LFnorm(Low frequency normalization), HFnorm(High frequency normalization), LF/HF ratio, Pupil area, B.S.(Basic size), C.R.(Max Constriction Rate) and 1s.d.(1sec Dilation Rate). I compared the degrees of the sympathetic and parasympathetic activity. Result : 1. In the result of heart rate variability between experimental and control group, none of the parameters of experimental group were significantly different from control group. And even though there were no statistical significance, there were some numerical differences in SDNN, LF norm, HF norm. 2. In pupil size variability, C.R. and 1s.d. of the experimental group were increased compared to control group. Conclusion : The study results suggest that the group with Keongke has differences of autonomic nervous system as compared to those in normal state. Measurement value of PSV is a new technical approach to estimate the autonomic nervous system.

  • PDF

Hydroelastic Analysis of Structural Vibration in Contact with Fluid (접수구조물 진동의 유력탄성해석)

  • K.T. Chung;Y.B. Kim;H.S. Kang;J.H. Roh
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.135-142
    • /
    • 1992
  • In the vibration analysis or submerged of floating bodies such as ship and offshore structures, the coupled system between structure and fluid satisfying the compatibility conditions on the wetted surface should be considered. It is well known that the hydroelastic analysis of structural vibration in contact with fluid can be solved by applying the finite element method to structure and the boundary element method to fluid domain. However such an approach is impractical, because fluid added mass matrix is fully coupled on whole wetted surface. To overcome this shortcoming, an efficient approach based on reanalysis scheme is proposed in this paper. The proposed method can be applied for cases with higher modes lacking 3-D reduction factor J as well as beam-like modes of marine structures. It is well known the traditional method using 2-D added mass and J-factor is good only for beam-like modes with reliable J values. The validity and the calculation efficiency of the proposed method are proved with numerical examples.

  • PDF

Nonlinear transient analysis of FG pipe subjected to internal pressure and unsteady temperature in a natural gas facility

  • Soliman, Ahmed E.;Eltaher, Mohamed A.;Attia, Mohamed A.;Alshorbagy, Amal E.
    • Structural Engineering and Mechanics
    • /
    • v.66 no.1
    • /
    • pp.85-96
    • /
    • 2018
  • This study investigates the response of functionally graded (FG) gas pipe under unsteady internal pressure and temperature. The pipe is proposed to be manufactured from FGMs rather than custom carbon steel, to reduce the erosion, corrosion, pressure surge and temperature variation effects caused by conveying of gases. The distribution of material graduations are obeying power and sigmoidal functions varying with the pipe thickness. The sigmoidal distribution is proposed for the 1st time in analysis of FG pipe structure. A Two-dimensional (2D) plane strain problem is proposed to model the pipe cross-section. The Fourier law is applied to describe the heat flux and temperature variation through the pipe thickness. The time variation of internal pressure is described by using exponential-harmonic function. The proposed problem is solved numerically by a two-dimensional (2D) plane strain finite element ABAQUS software. Nine-node isoparametric element is selected. The proposed model is verified with published results. The effects of material graduation, material function, temperature and internal pressures on the response of FG gas pipe are investigated. The coupled temperature and displacement FEM solution is used to find a solution for the stress displacement and temperature fields simultaneously because the thermal and mechanical solutions affected greatly by each other. The obtained results present the applicability of alternative FGM materials rather than classical A106Gr.B steel. According to proposed model and numerical results, the FGM pipe is more effective in natural gas application, especially in eliminating the corrosion, erosion and reduction of stresses.

Study on Flow Control of Primitive Structures for Enhancing Particulate Matter Filter Performance (미세먼지 필터 성능향상을 위한 primitive 구조의 유동 제어 연구)

  • J. B. Lee;S. H. Hwang;J. Y. Kim;H. Kim;D. Ahn;S. Y. Jung
    • Transactions of Materials Processing
    • /
    • v.33 no.4
    • /
    • pp.270-276
    • /
    • 2024
  • In order to improve the performance of the PM (Particulate Matter) filter, the TPMS structure was used as a flow controller to control the flow entering the filter. Among various TPMS structures, a primitive structure that is easy to utilize 3D printing technique was selected and the effect of unit cell size was analyzed. In addition, numerical analysis was performed and swirl ratio was analyzed to confirm changes in filter inlet flow characteristics that affect changes in filter performance. Unit cell size is closely related to filter performance, and both PM collection efficiency and pressure drop increase as unit cell size decreases. Through quality factor (QF) comparison, which comprehensively evaluate collection efficiency and pressure drop, it was confirmed that when the unit cell size is 5 mm, PM collection efficiency increases, but the flow controller actually reduces filter performance. QF values are similar for unit cell sizes of 10 and 20 mm, and it is advantageous to select the unit cell size among these two considering collection efficiency and operating costs. The filter's collection performance increases due to the increase in swirl flow caused by the primitive structure, and the filter's collection efficiency increases due to the swirl flow that increases throughout the flow field as the unit cell size becomes smaller.

Coal Ash Combustion Simulation for 500-MW Coal-firing Boiler (500MW급 화력발전 보일러의 석탄회 연소 시뮬레이션)

  • Hwang, Min-Young;Jeon, Chung-Hwan;Song, Ju-Hun;Kim, Gyu-Bo;Kim, Seung-Mo;Park, Myung-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.939-946
    • /
    • 2011
  • In thermal power generation companies, the recycling of refined ash (LOI < 6%) obtained from a PC-firing furnace is beneficial for the companies, e.g., it can be used for making lightweight aggregates. However, ash having a high LOI, which cannot be reused, is still buried in the ground. To obtain refined ash, the re-burning of high-LOI ash (LOI > 6%) in a PC-firing furnace can be an alternative. In this study, a numerical analysis was performed to demonstrate the effects of ash re-burning. An experimental constant value was decided by TGA (thermo-gravimetric analysis), and a DTF (drop-tube furnace) was used in the experiment for calculating the combustion of ash. On the basis of the trajectory of the moving particles of coal and ash, it was concluded that supplying ash near the burner, which is located high above the ground, is appropriate. On the basis of numerical results, it was concluded that an ash supply rate of 6 ton/h is suitable for combustion, without affecting the PC-firing boiler.

A Numerical Study of the Effect of Non-equilibrium Condensation on the Oscillation of Shock Wave in a Transonic Airfoil Flow (비평형 응축이 충격파 진동에 미치는 영향에 관한 수치 해석적 연구)

  • Jeon, Heung Kyun;Kim, In Won;Kwon, Young Doo;Kwon, Soon Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.3
    • /
    • pp.219-225
    • /
    • 2014
  • In this study, to find the characteristics of the oscillation of a terminating shock wave in a transonic airfoil flow with non-equilibrium condensation, a NACA00-12,14,15 airfoil flow with non-equilibrium condensation is investigated through numerical analysis of TVD scheme. Transonic free stream Mach number of 0.81-0.90 with the variation of stagnation relative humidity and airfoil thickness is tested. For the free stream Mach number 0.87 and attack angle of ${\alpha}=0^{\circ}$, the increase in stagnation relative humidity attenuates the strength of the terminating shock wave and inactivates the oscillation of the terminating shock wave. For the case of $M_{\infty}=0.87$ and ${\phi}_0=60%$, the decreasing rate in the frequency of the shock oscillation caused by non-equilibrium condensation to that of ${\phi}_0=30%$ amounts to 5%. Also, as the stagnation relative humidity gets larger, the maximum coefficient of drag and the difference between the maximum and minimum in $C_D$ become smaller. On the other hand, as the thickness of the airfoil gets larger, the supersonic bubble size becomes bigger and the oscillation of the shock wave becomes higher.

Numerical Simulation of Depth-Averaged Flow with a CDG Finite Element Method (CDG 유한요소법을 이용한 수심적분 흐름의 수치모의)

  • Kim, Tae Beom;Choi, Sung-Uk;Min, Kyung Duck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5B
    • /
    • pp.447-457
    • /
    • 2006
  • This paper presents a numerical model for the simulations of 2D depth-averaged flows. The shallow water equations are solved numerically by the Characteristic Dissipative Galerkin (CDG) finite element method. For validation, the developed model is applied to the hydraulic jump. The computed results are compared with the analytical solution, revealing good agreement. In addition, flow in a contracting channel showing standing waves is simulated. The calculated water surface profile appears to be qualitatively consistent with the observed data. The foregoing results indicate that the model is capable of simulating the abrupt change in flow field. Next, the model is applied to the flow in a $180^{\circ}$ curved channel. The simulated results show that the velocity near the inner bank is faster than that near the outer bank and the water depth near the inner bank is shallower than that near the outer bank. However, the simulated results show that the velocity distribution across the channel is almost uniform in the bend except the reach close to the end of the bend. This is due to the limitation of the governing equations in which the transverse convection of momentum by the secondary flows along a channel bend is not taken into account.