• Title/Summary/Keyword: number of measurements

Search Result 1,711, Processing Time 0.032 seconds

Study on the Radiation Pattern of Radiated Emission above 1 GHz (1 GHz 이상에서의 복사 방출 방사 패턴에 관한 연구)

  • Chung, Yeon-Choon;Lee, Soon-Yong;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.336-344
    • /
    • 2011
  • The purpose of this study is to analyze the radiation-pattern characteristics above 1 GHz for the electromagnetic wave radiated from multi-slot such as ventilations, etc. on the enclosure of an EUT and so to make recommendations for suitable test methods. An experimental EUT was formed by putting a comb-generator at the center of a rectangular enclosure with 4 slots, and its radiation pattern was analyzed in the frequency range of 1~6 GHz. As analysis results, multi-lobe appears above 2 GHz and the number of multi-lobes is growing as the frequency increases. And real radiated-emission measurements were performed for the experimental EUT by scanning a receiving antenna in the height of 1~4 m and tilting toward maximum radiation, as well as setting the height of a receiving antenna to the central position of the EUT which is prescribed at the present standards. The measured results are +12.8 dB in the scanning and +16.4 in the scanning and tilting compared with the present standard test method. Therefore, the latter must be revised in order to consider the radiation pattern above 1 GHz.

Bhumipol Dam Operation Improvement via smart system for the Thor Tong Daeng Irrigation Project, Ping River Basin, Thailand

  • Koontanakulvong, Sucharit;Long, Tran Thanh;Van, Tuan Pham
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.164-175
    • /
    • 2019
  • The Tor Tong Daeng Irrigation Project with the irrigation area of 61,400 hectares is located in the Ping Basin of the Upper Central Plain of Thailand where farmers depended on both surface water and groundwater. In the drought year, water storage in the Bhumipol Dam is inadequate to allocate water for agriculture, and caused water deficit in many irrigation projects. Farmers need to find extra sources of water such as water from farm pond or groundwater as a supplement. The operation of Bhumipol Dam and irrigation demand estimation are vital for irrigation water allocation to help solve water shortage issue in the irrigation project. The study aims to determine the smart dam operation system to mitigate water shortage in this irrigation project via introduction of machine learning to improve dam operation and irrigation demand estimation via soil moisture estimation from satellite images. Via ANN technique application, the inflows to the dam are generated from the upstream rain gauge stations using past 10 years daily rainfall data. The input vectors for ANN model are identified base on regression and principal component analysis. The structure of ANN (length of training data, the type of activation functions, the number of hidden nodes and training methods) is determined from the statistics performance between measurements and ANN outputs. On the other hands, the irrigation demand will be estimated by using satellite images, LANDSAT. The Enhanced Vegetation Index (EVI) and Temperature Vegetation Dryness Index (TVDI) values are estimated from the plant growth stage and soil moisture. The values are calibrated and verified with the field plant growth stages and soil moisture data in the year 2017-2018. The irrigation demand in the irrigation project is then estimated from the plant growth stage and soil moisture in the area. With the estimated dam inflow and irrigation demand, the dam operation will manage the water release in the better manner compared with the past operational data. The results show how smart system concept was applied and improve dam operation by using inflow estimation from ANN technique combining with irrigation demand estimation from satellite images when compared with the past operation data which is an initial step to develop the smart dam operation system in Thailand.

  • PDF

A Study on the Application of Universal Design Principles to Collective Housing for Senior citizen who lives alone - Focused on the 'Carnation House' in Gyeounggi-do ara - (독거노인을 위한 노인공동생활시설의 유니버설 디자인 적용성 평가 연구 - 경기도 지역 '카네이션하우스'를 중심으로 -)

  • Moon, Ja-Young;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.95-104
    • /
    • 2014
  • Today, the number of the elderly living alone without any family members is on a sharp rise, and those aged people living alone are making these social issues such as solitary death, depression and suicide more popular. In order to resolve the issues, some of the local governments have been supporting the elderly living alone in common houses that would be used by senior citizens only. This study became interested in this 'carnation house' which has been carried out targeting the elderly living alone in Gyeonggi-do, and selected elementary universal design factors that should be applied to general residential environments of the aged people and analyzed the factors. As a case study, this research investigated four carnation houses as research subjects and came up with these following ideas about how to make improvements. First, the study found out that all the entrances did not have raised letters and that UD has not been satisfactorily applied to both the thresholds and the effective widths, and that is considered something to be fixed. Second, in case of regular rooms and living rooms, none of the rooms failed to have safety doorknobs which should have been installed and plus, thresholds and stepped pulleys need to be removed, Third, it goes the same with the kitchens, and the thresholds should be eliminated while cabinets are secured. In addition, furniture that understands the elderly's measurements should be used. Fourth, in terms of restrooms, they should be designed to be spacious enough not to cause anyone in wheelchairs inconvenience, and the study suggests that the effective widths should be widened and that both the safety doorknobs and the emergency calls must be installed. Basically, after the test on the UD adaptability, the study concluded that the application rates in connection with the adaptability were low which led the study to assume that such result has been gained due to the lack of installation standards in relation to the common living facilities of the elderly. The study now argues that purposes of buildings should be first clarified and then, these detailed space planning guidelines that deal with general characteristics of the aged people should be established.

Estimation of Representative Area-Level Concentrations of Particulate Matter(PM10) in Seoul, Korea (미세먼지(PM10)의 지역적 대푯값 산정 방법에 관한 연구 - 서울특별시를 대상으로)

  • SONG, In-Sang;KIM, Sun-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.118-129
    • /
    • 2016
  • Many epidemiological studies, relying on administrative air pollution monitoring data, have reported the association between particulate matter ($PM_{10}$) air pollution and human health. These monitoring data were collected at a limited number of fixed sites, whereas government-generated health data are aggregated at the area level. To link these two data types for assessing health effects, it is necessary to estimate area-level concentrations of $PM_{10}$. In this study, we estimated district (Gu)-level $PM_{10}$ concentrations using a previously developed pointwise exposure prediction model for $PM_{10}$ and three types of point locations in Seoul, Korea. These points included 16,230 centroids of the largest census output residential areas, 422 community service centers, and 610 centroids on the 1km grid. After creating three types of points, we predicted $PM_{10}$ annual average concentrations at all locations and calculated Gu averages of predicted $PM_{10}$ concentrations as representative Gu-estimates. Then, we compared estimates to each other and to measurements. Prediction-based Gu-level estimates showed higher correlations with measurement-based estimates as prediction locations became more population representative ($R^2=0.06-0.59$). Among the three estimates, grid-based estimates gave lowest correlations compared to the other two(0.35-0.47). This study provides an approach for estimating area-level air pollution concentrations and assesses air pollution health effects using national-scale administrative health data.

Experimental Analysis of a Supersonic Plasma Wind Tunnel Using a Segmented Arc Heater with the Power Level of 0.4 MW (0.4 MW 급 분절형 아크 히터를 이용한 초음속 플라즈마 풍동 특성 실험)

  • Kim, Min-Ho;Lee, Mi-Yeon;Kim, Jeong-Soo;Choi, Chea-Hong;Seo, Jun-Ho;Moon, Se-Yeon;Hong, Bong-Guen
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.700-707
    • /
    • 2013
  • Experimental analyses on a supersonic plasma wind tunnel of CBNU (Chonbuk National University) were carried out. In these experiments, a segmented arc heater was employed as a plasma source and operated at the gas flow rates of 16.3 g/s and the total currents of 300 A. The input power reached ~350 kW with the torch efficiency of 51.4 %, which is defined as the ratio of total exit enthalpy to the input power. The pressure of plasma gas in the arc heater was measured up to 4 bar while it was down to ~45 mbar in a vacuum chamber through a Laval nozzle. During this conversion process, the generated supersonic plasma was expected to have a total enthalpy of ~11 MJ/kg from the measured input power and torch efficiency. In addition to the measurement of total enthalpy, a cone type probe was inserted into the supersonic plasma flow in order to estimate the angle between shock layer and surface of the probe. From these measurements, the temperature and the Mach number of the supersonic plasma were predicted as ~2,950 K and ~3.7, respectively.

A Study on Separation Control by Local Suction in Front of a Hemisphere in Laminar Flow (층류경계층 내 반구 전방의 국부적인 흡입에 의한 표면 박리 제어)

  • Kang, Yong-Duck;An, Nam-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.1
    • /
    • pp.92-100
    • /
    • 2018
  • Vortical systems are considered a main feature to sustain turbulence in a boundary layer through interaction. Such turbulent structures result in frictional drag and erosion or vibration in engineering applications. Research for controlling turbulent flow has been actively carried out, but in order to show the effect of vortices in a turbulent boundary layer, it is necessary to clarify the mechanism by which turbulent energy is transferred. For this purpose, it is convenient to demonstrate and capture phenomena in a laminar boundary layer. Therefore, in this study, the interactions of disturbed flow around a hemisphere on a flat plate in laminar flow were analyzed. In other words, a street of hairpin vortices was generated following a wake region formed after flow separation occurred over a hemisphere. Necklace vortices surrounding the hemisphere also appeared due to a strong adverse pressure gradient that brought high momentum fluid into the wake region thereby leading to an increase in the frequency of hairpin vortices. To mitigate the effect of these necklace vortices, local suction control was applied through a hole in front of the hemisphere. Flow visualization was recorded to qualitatively determine flow modifications, and hot-film measurements quantitatively supported conclusions on how much the power of the hairpin vortices was reduced by local wall suction.

Energy Based Source Location by Using Acoustic Emission for Damage Detection in Steel and Composite CNG Tank (금속 및 복합재 CNG 탱크에서의 손상 검출을 위한 음향방출 에너지 기반 위치표정 기술)

  • Kim, Il-Sik;Han, Byeong-Hee;Park, Choon-Su;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.332-340
    • /
    • 2015
  • Acoustic emission (AE) is an effective nondestructive test that uses transient elastic wave generated by the rapid release of energy within a material to detect any further growth or expansion of existing defects. Over the past decades, because of environmental issues, the use of compressed natural gas (CNG) as an alternative fuel for vehicles is increasing because of environmental issues. For this reason, the importance and necessity of detecting defects on a CNG fuel tank has also come to the fore. The conventional AE method used for source location is highly affected by the wave speed on the structure, and this creates problems in inspecting a composite CNG fuel tank. Because the speed and dispersion characteristics of the wave are different according to direction of structure and laminated layers. In this study, both the conventional AE method and the energy based contour map method were used for source location. This new method based on pre-acquired D/B was used for overcoming the limitation of damage localization in a composite CNG fuel tank specimen which consists of a steel liner cylinder overwrapped by GFRP. From the experimental results, it is observed that the damage localization is determined with a small error at all tested points by using the energy based contour map method, while there were a number of mis-locations or large errors at many tested points by using the conventional AE method. Therefore, the energy based contour map method used in this work is more suitable technology for inspecting composite structures.

Mangrove Height Estimates from TanDEM-X Data (TanDEM-X 자료를 활용한 망그로브 식생 높이 측정)

  • Lee, Seung-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.325-335
    • /
    • 2020
  • Forest canopy height can be used for estimate of above-ground forest biomass (AGB) by means of the allometric equation. The remote locations and harsh conditions of mangrove forests limit the number of field inventory data stations needed for large-scale modeling of carbon and biomass dynamics. Although active and passive spaceborne sensors have proven successful in mapping mangroves globally, the sensors generally have coarse spatial resolution and overlook small-scale features. Here we generate a 12 m spatial resolution mangrove canopy height map from TanDEM-X data acquired over the world largest intact mangrove forest located in the Sundarbans. With single-pol. TanDEM-X data from 2011 to 2013, the proposed technique makes use of the fact that the double-bounce scattering that occurs between the water and mangrove trees yields water surface level elevation over mangrove forest areas, thus allowing us to estimate forest height with the assumption of an underlying flat topography. Our observations have led to a large-scale mangrove canopy height map over the entire Sundarbans region at a 12 m spatial resolution. Our canopy height estimates were validated with ground measurements acquired in 2015, a correlation coefficient of 0.83 and a RMSE of 0.84 m. With globally available TanDEM-X data, the technique described here will potentially provide accurate global maps of mangrove canopy height at 12 m spatial resolution and provide crucial information for understanding biomass and carbon dynamics in the mangrove ecosystems.

Preparation and Gas Permeability Measurements of PVDF-HFP/Ionic Liquid Gel Membranes (PVDF-HFP/이온성 액체 겔 분리막 제조 및 기체 투과도 측정)

  • Ko, Youngdeok;Park, Doohwan;Baek, Ilhyun;Hong, Seong Uk
    • Applied Chemistry for Engineering
    • /
    • v.25 no.6
    • /
    • pp.559-563
    • /
    • 2014
  • It is well known that $CO_2$ can be dissolved easily in imidazolium-based room temperature ionic liquids (RTILs). Because of the high $CO_2$ solubility in RTILs, membranes containing RTILs can separate easily gas mixtures such as $CO_2/N_2$ and $CO_2/CH_4$. In this study, we prepared poly(vinylidene fluoride)-hexafluoropropyl copolymer (PVDF-HFP) gel membranes with several RTILs and measured permeabilities of several gases. When the anion of ionic liquids was tetrafluoroborate($BF{_4}^-$), both $CO_2$ permeability and selectivities decreased as the carbon number of the cation increased. When the cation of ionic liquids was 1-ethyl-3-methylimidazolium[emim], $CO_2$ permeability of gel membranes containing bis(trifluoromethane) sulfoneimide($Tf_2N^-$) anion was double compared to those containing tetrafluoroborate($BF{_4}^-$) anion. However, $CO_2/N_2$ and $CO_2/CH_4$ selectivities of the $Tf_2N^-$ case were decreased, whereas the $H_2$ selectivity was almost the same for two cases.

Velocity and Discharge Measurement using ADCP (ADCP를 이용한 유속과 유량 측정)

  • Lee, Chan-Joo;Kim, Won;Kim, Chi-Young;Kim, Dong-Gu
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.10 s.159
    • /
    • pp.811-824
    • /
    • 2005
  • The ADCP is an instrument based on Doppler effect, which measures discharge of a river in a short time while crossing it. In this study we aim to make a comparison of the discharge results from a moving-vessel ADCP with those measured by velocity-area method at the same cross-section, and to investigate the characteristics of velocity and discharge data using ADCP. Bathymetry measured by ADCP almost coincides with that by direct depth measurements. Because velocity data from ADCP are essentially instantaneous, individual velocity profiles obtained by ADCP are rather different from time-averaged velocity profiles. But spatially averaged velocity profiles of the individual ADCP data near the comparable verticals have similar vertical velocity pattern with the time-averaged ones. The average velocity profile from repeatedly crossed data is also similar with the time-averaged one. In case of the velocity distribution, individual and spatially averaged data for the sub-width of mid-section method Have good agreement with those by velocity-area method. Discharge data determined by averaging several ADCP measurement transects have $0.1\%{\~}9.3\%$ of difference with those from velocity-area method, and as the number of measurement increases, the relative difference to the velocity-area method decreases.