• Title/Summary/Keyword: normalized energy

Search Result 332, Processing Time 0.041 seconds

Degradation of Chlorinated Hydrocarbons via a Light-Emitting Diode Derived Photocatalyst

  • Jo, Wan-Kuen;Lee, Joon Yeob
    • Environmental Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • In this study, the applicability of visible light-emitting-diodes (LEDs) to the photocatalytic degradation of indoor-level trichloroethylene (TCE) and perchloroethylene (PCE) over N-doped $TiO_2$ (N-$TiO_2$) was examined under a range of operational conditions. The N-$TiO_2$ photocatalyst was calcined at $650^{\circ}C$ (labeled N-650) showed the lowest degradation efficiencies for TCE and PCE, while the N-$TiO_2$ photocatalysts calcined at $350^{\circ}C$, $450^{\circ}C$, and $550^{\circ}C$ (labeled as N-350, N-450, and N-550, respectively) exhibited similar or slightly different degradation efficiencies to those of TCE and PCE. These results were supported by the X-ray diffraction patterns of N-350, N-450, N-550, and N-650. The respective average degradation efficiencies for TCE and PCE were 96% and 77% for the 8-W lamp/N-$TiO_2$ system, 32% and 20% for the violet LED/N-$TiO_2$ system, and ~0% and 4% for the blue LED/N-$TiO_2$ system. However, the normalized photocatalytic degradation efficiencies for TCE and PCE for the violet LED-irradiated N-$TiO_2$ system were higher than those from the 8-W fluorescent daylight lamp-irradiated N-$TiO_2$ system. Although the difference was not substantial, the degradation efficiencies exhibited a decreasing trend with increasing input concentrations. The degradation efficiencies for TCE and PCE decreased with increasing air flow rates. In general, the degradation efficiencies for both target compounds decreased as relative humidity increased. Consequently, it was indicated that violet LEDs can be utilized as energy-efficient light sources for the photocatalytic degradation of TCE and PCE, if operational conditions of N-$TiO_2$ photocatalytic system are optimized.

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

A Study on the Comparison of Spatial Evapotranspiration between SEBAL and SWAT model results (SEBAL 모형과 SWAT 모형의 공간 증발산량 산정결과 비교 연구)

  • LEE, Yong-Gwan;JUNG, Chung-Gil;AHN, So-Ra;KIM, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.470-470
    • /
    • 2015
  • 본 연구의 목적은 위성영상 기반의 SEBAL(Surface Energy Balance Algorithm for Land) 모형과 SWAT(Soil and Water Assessment Tool) 수문모형을 용담댐 유역($922.3km^2$)에 적용하여 증발산량을 산정하고 모형 간 공간 증발산량의 비교를 통해 각 모형의 적용성을 평가하는데 있다. 이를 위해 SEBAL모형의 입력자료로 Terra MODIS(Moderate Resolution Imaging Spectrometer) Product 중 Normalized Distribution Vegetation Index(NDVI), Albedo 영상을 2012년부터 2013년까지 월단위로 구축하고, 일단위의 Land Surface Temperature(LST) 영상을 구축하였다. 지형자료로는 Digital Elevation Model(DEM)과 Land use를 구축하였으며 SEBAL 모형의 구동을 위한 위성영상 및 지형자료는 500 m의 공간해상도로 재구축하였다. SWAT 모형의 모의를 위해 기상 및 유량 자료를 2000년부터 2013년까지 일단위로 구축하였고, DEM, Land use, 토양도의 지형자료를 30 m의 공간해상도로 구축하였다. SWAT 모형의 유출 검보정 후 수위관측소 지점에서 평균 $R^2$를 산정한 결과 도치(0.80), 동향(0.72), 석정(0.64), 주천(0.80), 천천(0.80), 용담댐(0.72)로 높은 상관성을 나타냈으며, 유출 검보정 후 SWAT 모형의 증발산량 모의 결과를 바탕으로 SEBAL 모형과의 공간 증발산량을 비교하였다. 두 모형의 증발산량은 SEBAL 모형의 경우 지형에 따라 SWAT 모형은 토양 특성에 따라 분포하는 경향이 다르게 나타났다. SEBAL 모형은 주로 저지대에서 증발산량이 높게 산정되며 고지대로 갈수록 감소하여 증발산량이 지형의 고저차에 따라 분포하는 모습을 보였다. SWAT 모형은 토양 특성에 따라 증발산량이 분포하며 유역 내에서 뚜렷한 차이를 나타내지는 않았다. 월별 총 증발산량은 SWAT 모형의 경우 7~8월에 약 90 mm/mon로 가장 높게 나타나고 1~2월은 0 mm/mon로 계절별 변화폭이 컸으나, SEBAL 모형의 경우 5~6월에 증발산량이 약 60 mm/mon로 가장 높게 나타났고 계절별 변화 폭이 SWAT 모형에 비해 적은 모습을 보였다. 이는 위성영상을 기반으로 하는 SEBAL 모형의 특성상 장마 기간에 해당하는 7~8월은 구름으로 인해 일사량이 적게 계산되고, 그 결과 5~6월에 비해 증발산량이 작게 산정되는 것으로 판단된다.

  • PDF

Study on the Photocatalytic Characteristic and Activity of Cu2O/TiO2 Heterojunction Prepared by Ultrasonification (초음파 합성 적용 Cu2O/TiO2 이종접합 소재의 특성 및 활성도 평가에 관한 연구)

  • Choi, Jeong-Hak;Lee, Joon Yeob
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1213-1222
    • /
    • 2020
  • In the current study, a Cu2O/TiO2 photoinduced nanocomposite materials prepared by ultrasonification method was evaluated the photocatalytic oxidation efficiency of volatile organic compounds (BTEX) under visible-light irradiation. The results of XRD confirmed the successful preparation of photoinduced nanocomposite materials. However, diffraction peaks belonging to TiO2 were not confirmed for the Cu2O/TiO2. The possible reason for the absence of Cu2O peak is their low content and small particle size. The result of uv-vis spectra exhibited that the fabricated Cu2O/TiO2 can be activated under visible light irradiation. The FE-SEM/EDS and TEM showed the formation of synthesized nanocomposites and componential analysis in the undoped TiO2 and Cu2O/TiO2. The photocatalytic oxidation efficiencies of benzene, toluene, ethylbenzene, and o-xylene with Cu2O/TiO2 were higher than undoped TiO2. According to light sources, the average oxidation efficiencies for BTEX by Cu2OT-0.5 were exhibited in the orer of 8 W day light > violet LEDs > white LEDs. However, the photocatalytic oxidation efficiencies normalized to supplied electric power were calculated to be in the following order of violet LEDs > white LEDs > 8 W day light, indicating that the LEDs could be a much more energy efficient light source for the photo-oxidation of gaseous BTEX using Cu2O/TiO2.

Growth and Characterization of InGaP/InGaAs p-HEMI Using Compound Source MBE (Compound Source MBE를 이용한 InGaP/InGaAs p-HEMT 구조의 성장 및 특성 분석)

  • Kim, J.H.;S.J. Kang;S.J. Jo;J.D. Song;Lee, Y.T.;J.I. Song
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.16-19
    • /
    • 2000
  • DC and low frequency noise characteristics of InGaP/InGaAs pseudomorphic HEMTs (p-HEMTs) grown by compound source MBE are investigated for temperature range of 150K to 370K. Equivalent input noise spectra( $S_{iv}$ ) were measured as a function of frequency and temperature. $S_{iv}$ was measured to be 3.4 $\times$ 10$^{-12}$ $V^2$/ Hz at 1kHz for 1.3 X 50${\mu}{\textrm}{m}$$^2$InGaP/InGaAs p-HEMT at room temperature. Measurements of the low-frequency noise spectra of the p-HEMT as a function of temperature show that the trap with an activation energy level around 0.589 eV is a dominant trap that accounts for the low-frequency noise behavior of the device. The normalized extrinsic gm frequency dispersion of the p-HEMT. was as low as 2.5% at room temperature, indicating that the device has well-behaved low-frequency noise characteristics. Sub-micron (0.25 $\times$ 50${\mu}{\textrm}{m}$$^2$) gate p-HEMT showed $f_{T}$ and $f_{max}$ of 40GHz and 108GHz, respectively.y.y.

  • PDF

Assessment of Topographic Normalization in Jeju Island with Landsat 7 ETM+ and ASTER GDEM Data (Landsat 7 ETM+ 영상과 ASTER GDEM 자료를 이용한 제주도 지역의 지형보정 효과 분석)

  • Hyun, Chang-Uk;Park, Hyeong-Dong
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.4
    • /
    • pp.393-407
    • /
    • 2012
  • This study focuses on the correction of topographic effects caused by a combination of solar elevation and azimuth, and topographic relief in single optical remote sensing imagery, and by a combination of changes in position of the sun and topographic relief in comparative analysis of multi-temporal imageries. For the Jeju Island, Republic of Korea, where Mt. Halla and various cinder cones are located, a Landsat 7 ETM+ imagery and ASTER GDEM data were used to normalize the topographic effects on the imagery, using two topographic normalization methods: cosine correction assuming a Lambertian condition and assuming a non-Lambertian c-correction, with kernel sizes of $3{\times}3$, $5{\times}5$, $7{\times}7$, and $9{\times}9$ pixels. The effects of each correction method and kernel size were then evaluated. The c-correction with a kernel size of $7{\times}7$ produced the best result in the case of a land area with various land-cover types. For a land-cover type of forest extracted from an unsupervised classification result using the ISODATA method, the c-correction with a kernel size of $9{\times}9$ produced the best result, and this topographic normalization for a single land cover type yielded better compensation for topographic effects than in the case of an area with various land-cover types. In applying the relative radiometric normalization to topographically normalized three multi-temporal imageries, more invariant spectral reflectance was obtained for infrared bands and the spectral reflectance patterns were preserved in visible bands, compared with un-normalized imageries. The results show that c-correction considering the remaining reflectance energy from adjacent topography or imperfect atmospheric correction yielded superior normalization results than cosine correction. The normalization results were also improved by increasing the kernel size to compensate for vertical and horizontal errors, and for displacement between satellite imagery and ASTER GDEM.

Detection Characteristics of Gamma-Irradiated Korean Medicinal Herbs by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석에 의한 감마선 조사 한약재의 검지 특성)

  • Yang, Hee-Sun;Park, Yong-Dae;Jin, Chang-Hyun;Choi, Dae-Seong;Chung, Hyung-Wook;Byun, Myung-Woo;Jeong, Il-Yun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1529-1533
    • /
    • 2008
  • The detection characteristics of gamma-irradiated ($0{\sim}10.0\;kGy$) medicinal herbs (Platycodon grandiflorum, Acanthopanax chiisanensis) were investigated by photostimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of the PSL, a first screening method in comparison with the TL, showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples, while the non-irradiated samples yielded photon counts less than 700 counts/60 s (negative). The TL was also applied for the detection method of irradiated medicinal herbs and showed that the non-irradiated sample revealed a glow curve with a low intensity, while the irradiated samples showed a higher intensity. These results were normalized by re-irradiating the mineral grains with a irradiation dose of 1.0 kGy, and a second glow curve was recorded. The ratio of the intensity of the first glow curve ($TL_1$) to that after the normalization dose ($TL_2$) was determined and compared with the recommended threshold values. TL ratio ($TL_1/TL_2$) was below 0.007 for the non-irradiated sample and higher than 0.1 for all irradiated samples (above 1.0 kGy). ESR spectroscopy revealed specific signals (6.065 mT) derived from free radicals in cellulose containing irradiated medicinal herbs. The P. grandiflorum showed clearer signals than A. chiisanensis. From the results of our studies, the PSL, TL, and ESR determinations were found to be suitable for the detection of irradiated medicinal herbs such as P. grandiflorum and A. chiisanensis.

Region Analysis of Business Card Images Acquired in PDA Using DCT and Information Pixel Density (DCT와 정보 화소 밀도를 이용한 PDA로 획득한 명함 영상에서의 영역 해석)

  • 김종흔;장익훈;김남철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1159-1174
    • /
    • 2004
  • In this paper, we present an efficient algorithm for region analysis of business card images acquired in a PDA by using DCT and information pixel density. The proposed method consists of three parts: region segmentation, information region classification, and text region classification. In the region segmentation, an input business card image is partitioned into 8 f8 blocks and the blocks are classified into information and background blocks using the normalized DCT energy in their low frequency bands. The input image is then segmented into information and background regions by region labeling on the classified blocks. In the information region classification, each information region is classified into picture region or text region by using a ratio of the DCT energy of horizontal and vertical edge components to that in low frequency band and a density of information pixels, that are black pixels in its binarized region. In the text region classification, each text region is classified into large character region or small character region by using the density of information pixels and an averaged horizontal and vertical run-lengths of information pixels. Experimental results show that the proposed method yields good performance of region segmentation, information region classification, and text region classification for test images of several types of business cards acquired by a PDA under various surrounding conditions. In addition, the error rates of the proposed region segmentation are about 2.2-10.1% lower than those of the conventional region segmentation methods. It is also shown that the error rates of the proposed information region classification is about 1.7% lower than that of the conventional information region classification method.

A Numerical Model for Predicting the Radial Power Profile in CANDU-PHWR Fuel Pellet (CANDU-PHWR 핵연료 소결체의 반경방향 출력분포 수치모형)

  • Woan Hwang;Suk, Ho-Chun;Jae, Won-Mok
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.444-455
    • /
    • 1991
  • An accurate and fast running NEDAR model for calculating radial power profile throughout fuel life in both solid and annular pellets for existing and advanced CANDU-PHWR-fuel was developed in this work. This model contains resultant flux depression equations and neutron depression data tables which have been developed for CANDU-PHWR fuel of pellet with the diameter 8.0 to 19.5 mm and enrichment 0.71-6.0 wt % U-235, over a bumup range of 0 to 840 MWh /kgU (35000 MWD/T). In order to obtain the neutron flux distribution in the fuel pellet, the CE-HAMMER physics code was run for a neutron flux spectrum appropriate to a CANDU-PHWR to give predictions of radial power profile for several ranges of fuel design parameters. The results, which were calculated by the CE-HAMMER physics code, were fitted to an equation which is solved in terms of Bessel and exponential functions in order to obtain the parameters, $textsc{k}$, $\beta$ and λ in the resultant equation. The present NEDAR model produce a radial profile which, when normalized to unity at the pellet surface, is slightly higher than the profile of the original ELESIM data table. The predictions of the fission gas release by KAFEPA-NEDAR are in slightly better agreement with the experiments than those of ELESIM. The NEDAR model described in this study has been shown to provide an effective, reliable, and accurate method for determining radial power profiles in CANDU-PHWR fuel rods without incurring a significant increase in computing time.

  • PDF

Characteristics of Photon Beam through a Handmade Build-Up Modifier as a Substitute of a Bolus (Bolus를 대체하기 위해 자체 제작된 선량상승영역 변환기를 투과한 광자선의 특성)

  • Kim, Sung Joon;Lee, Seoung Jun;Moon, Su Ho;Seol, Ki Ho;Lee, Jeong Eun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.225-232
    • /
    • 2014
  • We evaluated the effect of scatter on a build-up region based on the measured percent depth dose (PDD) of high-energy photon beams that penetrated a handmade build-up modifier (BM) as a substitute of bolus. BM scatter factors ($S_{BM}$) were calculated based on the PDDs of photon beams that penetrated through the BM. The calculated $S_{BM}$ values were normalized to 1 at the square field side (SFS) of 30 mm without a BM. For the largest SFS (200 mm), the SBM values for a 6-MV beam were 1.331, 1.519, 1.598, 1.641, and 1.657 for the corresponding BM thickness values. For a 10-MV beam, the $S_{BM}$ values were 1.384, 1.662, 1.825, 1.913, and 2.001 for the corresponding BM thickness values. The BM yielded 76% of the bolus efficiency. We expect BM to become useful devices for deep-set patient body parts to which it is difficult to apply a bolus.