• Title/Summary/Keyword: normal wear

Search Result 420, Processing Time 0.031 seconds

Changes in Centration of Contact Lenses on Cornea and Blink Rate Associated with Overusage of Disposable Lenses (일일 착용 렌즈의 착용기간 초과시 유발되는 렌즈의 중심 안정 위치 및 순목횟수 변화)

  • Park, Mijung;Yang, Jae Heon;Kim, Sun Mi;Park, Sang-Il;Park, Sang Hee;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Purpose: This study was assessed to investigate adverse effect induced by overuse of disposable soft contact lenses (CL). Methods: Three disposable lenses (etafilcon A, hilabilcon A, and nelfilcon A) were applied to 19 normal subjects free from any eye diseases for either a single day or variable periods by when subjects complained any discomforts. On the first and last days, localizations of lens' center on corneal surface and blink rates were recorded at every case. Results: Among CL wearers, 10.5% and 47.4% of total subjects quit wearing on the second day and third day, respectively. The case of stopping disposable lens wear was continuously increased with extended hour of lens application. On fourth day, 70.2% of CL wearers reported severe discomforts such as redness, dryness, irritation, pain and blurred vision. When subjects stopped CL wear, decentration of lens from the center of cornea was observed when it compared to the case of single usage of disposable CL. Also about 80% of total subjects showed increased blink rate when CL were worn for more than 2 days. These changes in lens centration and blink rate were consistantly shown regardless of lens types. Conclusions: Blurred vision and acute/chronic discomforts could occur to CL wearers by decentration of lens and increased blink rate when CL were overused more than 2 days even the numbers of two parameters measured in this study were variable by each subject or lens types. Therefore, consideration of individual characteristics and lens types is critical to prevent adverse effects may induced by overusage of disposable lens.

  • PDF

Convergent Influence Effect on the High - Quality CPR of 119 Paramedics by Wearing Personal Protective Equipment by Level (구급대원의 수준별 개인용 보호구 착용에 따른 심폐소생술 품질에 미치는 융합적인 영향)

  • Shin, Dong-Min;Cho, Byung-Jun;Yang, Hyun-Mo;Jeon, Seong-Man;Han, Yong-Taek
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.71-78
    • /
    • 2020
  • The purpose of this study is to investigate the effect of wearing clothes, Level B, and Level C PPE on normal CPR using mannequins. The paramedics who participated in this experiment were 20 paramedics with more than 5 years of experience in firefighting area C. It was found that chest compressions in the process that hand off time was 11.9 seconds in the uniform wearing group, 11.4 seconds in the level C PPE wearing group, and 13.1 seconds in the SCBA wearing group. In other words, wearing personal protective equipment prevents the movement of paramedics and uses compensatory movements, which may increase the difficulty of efficient first aid. If this situation persists, it may cause fatigue and damage to the body of paramedics. Rescue and paramedics should wear level personal protective equipment in case of emergencies and conduct rescue and CPR training.

A Comparative Study on Chinese Adult women's constitutional components and Somatotype Characteristic (지역별.연령별 중국 성인여성(地域別.年齡別 中國 成人女性)의 체형구성 요인(體型構成 要因)과 유형 비교 연구(類型 比較 硏究))

  • Wee, Hye-Jung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.10 no.5
    • /
    • pp.58-73
    • /
    • 2006
  • The purpose of this study was to improve of fittness and coverage rate of exporting domestic clothing to China for Chinese Adult Female. For study, It was measured 1381 female women aged between 19 and 50 who resident in Beijing and Shanghai in China. as a sample, 1360 female women was seleted for development of apparel sizing system. As for the method of this study was made of 111 items by indirect measures done during Jun. 23 $\sim$ Aug. 7, 2004. Data analysis were processed by SPSS WIN 10.0 Program was used to for technical statistical analysis, correlation analysis, factor analysis, ANOVA(t-test and F-test), duncan's multiple test. The result was as follows: Chinese Adult women's constitutional components determined by factor analysis, six components could be identified: factor 1:constitutional obesty and width size, factor 2: longistudinal body size, factor 3: shoulder form and size, factor 4: longistudinal upper body size, factor 5: under body size, factor 6: shoulder dropping. According to the Women's Wear Specifications(GB/T 1335.2-1997) by drop, body types of Chinese Adult female was classified into six types, it was Y, A, B, C and Z, D. In order, A type as standard somatotype(49.8%), B type(26.9%), Y type (18.8%), C type(2.9%). Y type had the average height and shoulder, bust girth. They were slimmer in overall terms. A type had a normal obesity and body size in height, shoulder, bust girth. They were average Chinese Women. B type had a smaller then A type. They were more obes and thick waist girth. C type had the highest obesity, the widest shoulder and bust girth, and thick waist girth. The characteristics of each body type following the body type structure factor are Y-type for slender type, A-type for standard type, B-type for slightly large type, and C-type for obese type. For each region, the Beijing area had in the order of A-type, Y-type, B-type and C-type, and the Shanghai area had in the order of A-type, B-type, Y-type and C-type.

One-Stage Achilles Tendon Reconstruction Using the Free Composite Dorsalis Pedis Flap in Complex Wound (족배부 복합 피부-건 유리피판을 이용한 Achilles건의 일단계 재건술)

  • Kim, Sug Won;Lee, Won Jai;Seo, Dong Wan;Chung, Yoon Kyu;Tark, Kwan Chul
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • The soft tissue defects including the Achilles tendon are complex and very difficult to reconstruct. Recently, several free composite flaps including the tendon have been used to reconstruct large defects in this area in an one-stage effort. Our case presents a patient reconstructed with free composite dorsalis pedis flap along with the extensor digitorum longus and superficial peroneal nerve for extensive defects of the Achilles tendon and surrounding soft tissue. A 36-year-old-man sustained an open injury to the Achilles tendon. He was referred to our department with gross infection of the wound and complete rupture of the tendon associated with loss of skin following reduction of distal tibial bone fracture. After extensive debridement, $6{\times}8cm$ of skin loss and 8cm of tendon defect was noted. Corresponding to the size of the defect, the composite dorsalis pedis flap was raised as a neurosensory unit including the extensor digitorum longus to provide tendon repair and sensate skin for an one-stage reconstruction. One tendon slip was sutured to the soleus musculotendinous portion, the other two were sutured to the gastrocnemius musculotendinous portion with 2-0 Prolene. The superficial peroneal nerve was then coaptated to the medial sural cutaneous nerve. The anterior tibial artery and vein were anastomosed to the posterior tibial artery and accompanying vein in an end to end fashion. After 12 months of follow-up, 5 degrees of dorsiflexion due to the checkrein deformity and 58 degrees of plantar flexion was achieved. The patient was able to walk without crutches. Twopoint discrimination and moving two-point discrimination were more than 1mm at the transferred flap site. The donor site healed uneventfully. Of the various free composite flaps for the Achilles tendon reconstruction when skin coverage is also needed, we recommand the composite dorsalis pedis flap. The advantages such as to control infection, adequate restoration of ankle contour for normal foot wear, transfer of the long tendinous portion, and protective sensation makes this flap our first choice for reconstruction of soft tissue defect including the Achilles tendon.

  • PDF

Study on the Characteristics of Noise/Vibration in the Upright Laying Hen House (직립식 산란계사 내의 소음 진동 발생 현황 조사연구)

  • Lee S.J.;Chang D.I.;Chang H.H.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • This study was carried out to measure and analyze the characteristics of noise and vibration, and to analyze their effects on the productivity of layers, mechanical troubles, and abnormal wear-out failure of facilities and equipment of the layer house. The measurements of noise and vibration were taken at 13 layer farms nationwide for the operations of feed supplier system, feed distribution system, automatic egg collection system, ventilation system, blot conveyer for layer feces, and fur the case of with and without their operation by a sound level meter and a vibration measuring system in the layer house equipped with upright multi-tier cages. Measurement results showed that normal times were noise(N) 82 dB and vibration(V) 0.2072 cm/s, feed supplier system were 90 dB(N) and 2.8560 cm/s(V), feed distribution system were 90 dB(N) and 2.0222 cm/s(V), automatic egg collection system were 87 dB(N) and 0.1865 cm/s(V), ventilation system 88 dB(N) and 2.5364 cm/s(V), belt conveyer fur layer feces were 88 dB(N) and 0.2387 cm/s(V), and then maximum values of noise and vibration were 90 dB and 2.8560 cm/s, respectively, when feeding systems(feed supplying system and feed distribution system) were operated. Based on these results, an experiment is being conducted to find out the effect of noise and vibration on the productivity of layers in the layer house equipped with upright multi-tier cages.

  • PDF

A Study on Face Types and Glasses Wear of Young Peoples (청년들의 얼굴형태와 안경착용에 관한 연구)

  • Kim, Hye-Dong;Kim, Hyun-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.35-38
    • /
    • 2007
  • This study surveyed on eye size, face types and glasses wears of normal 100 young peoples from 20 to 30 years old. The analysis of data resulted in as follows: 1. The vertical eye size were in case of below 2.4 mm (2%), 2.5-2.9 mm (40%), 3.0-3.5 mm (57%), and in case of high 3.6 mm (1%). 2. The horzontal eye size were in case of below 1.1 mm (52%), 1.2-1.4 mm (28%), 1.5-1.7 mm (18%), and in case of high 1.8 mm (2%). 3. As a whole, the face types were oval type (29%), round type (24%), square type (18%), and triangle type (2%). 4. As the male, the face types were oval type (32%), round type (10%), square type (26%), and triangle type (32%). 5. As the female, the face types were oval type (18%), round type (40%), square type (12%), and triangle type (30%). 6. As a whole, the FPD size were in case of larger than PD (49%), in case of suitable (25%), in case of smaller than PD (49%). 7. As the male, the FPD size were in case of larger than PD (28%), in case of suitable (36%), and in case of smaller than PD (32%). 8. As the female, the FPD size were in case of larger than PD (44%), in case of suitable (26%), and in case of smaller than PD (30%).

  • PDF

Relationship of Types of Foot Shape and Favorite Shoes Shape of Female University Students (여대생의 발 유형과 선호 구두 형태와의 관계)

  • Lee, Jin-Hee;Kim, Kyung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.12 no.1
    • /
    • pp.75-84
    • /
    • 2003
  • The objective of this paper was to analyse the foot type of female university students by the direct and indirect measure of foot and the measures of foot outline. The results were as follow: 1. The length and the width of foot were small and ankle slender and the modification of the big toe slight. 2. The analysis on the 16 measure items revealed five factors; the first factor was related to the width and girth of foot, the second one to the length of foot, the third one to the transformation of the little toe, the fourth one to the height of foot, the fifth one to transformation of the big toe. 3. The grouping on the shape of foot revealed three types. The inline angle of foot was the smallest in average in the type 1, while it appeared to be middle in the other types. The wider foot shapes were grouped as type 2 because their inline and outline angles of foot were the biggest in average. In the type 3, the big toe was curved a lot, since it was the largest in average. 4. From the naked eye measuring method, classification from which toe was popped-out told that Egyptian foot was 30.9%, Greek foot 27.9%. On the other hand, the instrumental method showed that Egyptian foot was 57.3%, Squared foot 35.3% and Greek foot 7.4%. 5. The result from the analysis about the traits of foot shape by the degree of the arch formation of bottom foot, showed that 33.8% had the normal foot, 66.2% slightly flat foot or middle one. There was no one with rigid flat foot. 6. The shoes size they declared were that 240cm was 33.3%, 235cm 18.1% and 245cm 18.1%. The shape of their shoe heel were flat heel(34.8%), cuban heel(25.5%), and narrow straight heel(19.9%); and that of the shoe toe were round toe(25.4%), oval toe(20.4%) and squared toe(20.4%). 7. The discomforting parts when they wear shoes were the little toe(35.4%), the rear of foot(13.9%), and the width of foot(13.9%), which was related to their dislike of shoe with the pointed toe.

  • PDF

A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants (발전소의 스팀제어용 유압서보 액추에이터의 공기배출 밸브에 관한 연구)

  • Lee, Yong Bum;Lee, Jong Jik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.397-402
    • /
    • 2016
  • To produce adequate electricity in nuclear and thermal power plants, an optimal amount of steam should be supplied to a generator connected to high- and low-pressure steam turbines. A turbine output control device, which is a special steam valve employed to supply or interrupt the steam to the turbine, is operated using a hydraulic servo actuator. In power plants, the performance of servo actuators is degraded by the air generated from the hydraulic system, or causes frequent failures owing to an increase in the wear of the seal. This is due to the seal being burnt as generated heat using the produced compressed air. Some power plants have exhausted air using a fixed orifice, and thus they encounter power loss due to mass flow exhaust. Failures are generated in hydraulic pumps, electric motors, and valves, which are frequently operated. In this study, we perform modeling and analysis of the load-sensing air-exhaust valves, which can be passed through very fine flow under normal use conditions, and exhaust mass flow air at the beginning stage as with existing fixed orifices. Then, we propose a method to prevent failures due to the compressed air, and to ensure the control accuracy of hydraulic servo actuators.

EFFECT OF FLUORIDE VARNISH ON DEVELOPMENT OF ARTIFICIAL CARIES (불소 바니쉬가 인공 우식 병소의 발생에 미치는 영향)

  • Cho, Nan-Ju;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.613-622
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of fluoride varnish on prevention of enamel demineralization. Eighty bovine enamel blocks were divided randomly into 4 groups of 20 specimens: Group I served as the control with no topical application of fluoride. Group II was treated with APF gel for 4 minutes. Group III was treated with Fluor $Protector^{(R)}$. Group IVV was treated with $CavityShield^{TM}$. After 24 hours of treatment, samples were brushed with a soft bristled tooth brush to stimulate normal mechanical wear of varnish. Early caries lesions were produced by placing each specimen into demineralization solution at pH 4.0 for 48 hours. Then the optical density of the lesions was measured by light fluorescence induced by plasma light and the surface microhardness were measured by the vicker's hardness test. The results were as follows: 1. The optical densities of group III, IV were significantly higher than that of group II, but no significant difference was noted between group III and IV. 2. The surface microhardness of group IV was the highest, followed by group III, II, and I(p<0.05). 3. There were no significant differences between group III and IV in optical density. However, the surface microhardness of group IV was significantly higher than that of group III. The results of present study indicate that the fluoride varnish is more effective than APF gel for prevention of dental caries.

  • PDF

The Second Animal Tests of Artificial Heart Valves (인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험-)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF