• 제목/요약/키워드: normal speakers

검색결과 90건 처리시간 0.019초

정상 성인의 말속도 및 유창성 연구 (A Study af Speech Rate and Fluency in Narmal Speakers)

  • 신문자;한숙자
    • 음성과학
    • /
    • 제10권2호
    • /
    • pp.159-168
    • /
    • 2003
  • The purpose of this study was to assess the speech rate, fluency and the type of dysfluencies of normal adults in order to provide a basic data of normal speaking. The number of subjects of this study were 30(14 females and 16 males), and their ages ranged 17 to 36. The rate was measured as syllables per minute (SPM). The speech rates in reading ranged 273-426 with a mean of 348 SPM and in speaking ranges 118-409 (mean=265). The average of their fluencies was 99.1% in reading and 96.9% in speaking. The rater reliability of speech rate in the data assessed by video was very high (r=0.98) and the rater reliability of speech fluency was moderately high (r=0.67). The disfluency types were also analysed from 150 disfluency episodes. Syllable repetition and word interjection were the most common disfluent types.

  • PDF

Acoustic Characteristics of Korean Deaf Speakers

  • 이상한;한명진;정옥란;조태환
    • 음성과학
    • /
    • 제2권
    • /
    • pp.89-94
    • /
    • 1997
  • This study was attempted to analyze the acoustic characteristics of profoundly deaf students. The 59 profoundly hearing-impaired and 36 normal subjects were divided into 3 age groups: 6-10 yrs group, 11-15 yrs group, and 16-20 yrs group. The voice was sampled in /a/ prolongation, counting, reading, and conversation using the Computerized Speech ,Lab (CSL). The vocal pitch of the deaf subjects was significantly higher than the normal subjects. The younger in age was tended to be higher in pitch and jitter values of the deaf subjects. The three age groups of the deaf subjects did not show any difference in loudness and shimmer, excepted to minimum loudness. The pitch mean of males was significantly lower than that for females.

  • PDF

발화속도가 경계앞 음절 길이에 미치는 영향 (The Effects of the Speaking Rate on the Duration of Syllable before Boundary)

  • 이순향;구희산
    • 음성과학
    • /
    • 제1권
    • /
    • pp.103-111
    • /
    • 1997
  • The purpose of this study was to investigate the effect of the speaking rate on the duration of syllable before boundary. The materials used were four types of syllable-boundary sequences(Go-'Ga' Boundary-Gu) in a paragraph. The duration of 'Ga' syllables before 4 level of boundary was measured, and all of the measurements were taken from signals and spectrograms made by the $Signalyze^{TM}$ 3.04 for Power Mac 7200. Subjects were six female speakers who read the materials at fast, normal, and slow speed five times. The results show that (1) the slower the speaking rate becomes, the longer the duration of syllable before boundary, (2) the duration rank of syllable before each boundary does not correspond to the level of boundary, eg. at fast speed, = < #, + < $ ; at normal speed, +, #, = < $ ; at slow speed, + < =, #, $, and (3) the syllable before sentence boundary is less influenced than syllable before another boundary.

  • PDF

한국어 원거리 음성의 운율적 특성 (Prosodic Characteristics of Korean Distance Speech)

  • 이숙향;김선희;김종진
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2005년도 추계 학술대회 발표논문집
    • /
    • pp.87-90
    • /
    • 2005
  • The aim of this paper is to investigate the prosodic characteristics of Korean distant speech. 36 2-syllable words of 4 speakers (2 males and 2 females) produced in both distant-talking and normal environments were used. The results showed that ratios of second syllable to first syllable in vowel duration and vowel energy were significantly larger in the distant-talking environment compared to the normal environment and f0 range also bigger in the distant-talking environment. In addition, 'HL%' contour boundary tone in the second syllable and/or 'L +H' contour tone in the first syllable were used in the distant-talking environment.

  • PDF

다채널 음성분석장치를 이용한 정상 성인에서의 발성 방식에 따른 음성변수 분석 (Analysis of Voice Parameters on Different Phonatory Tasks using Multi-Channel Phonatory Function Analyzer in Healthy Adults)

  • 성명훈;이상준;김광현;노종렬;권택균;이강진;박광석;최종민
    • 대한후두음성언어의학회지
    • /
    • 제13권2호
    • /
    • pp.132-138
    • /
    • 2002
  • Background and Objectives : The complex physiologic structure of the larynx can vibrate in three or more different ways that yield acuostically and perceptually distinct vocal quality. The purpose of this study is to examine the normal range of voice parameters in Multi-Channel Phonatory Function Analyzer and investigate the difference of voice parameters according to the phonatory patterns. Materials and Methods : Forty normal adult speakers (20 men and 20 women) with age ranging from third to forth decades pronounce low, comfortable, and high tone /a/ ; comfortable tone /${\ae}$/, /i/, /o/, and /u/ : fry, falsetto. Voice was analyzed by Newly developed multi-channel phonatory function analyzer. Results : The normal range of voice parameters in this system was similar to the existing data. Fry shows high jitter and falsetto low SQ. Fry and falsetto show low OQ in men but no difference in women. Jitter, OQ and SQ were different between men and women in modal register, whereas there was no gender difference in fry and falsetto. In frequency magnitude spectrum and EGG, modal register, fry and falsetto have distinguishing pattern. Conclusions : Modal register, fry and falsetto are distinguishable in voice parameters and show different vibratory patterns.

  • PDF

중학교 일반교실 실내음향 시뮬레이션에 관한 연구 (A Study on the Computer Simulation of Acoustic Characteristics in Middle School Lecture Room)

  • 모승준;이민섭
    • 교육시설
    • /
    • 제10권4호
    • /
    • pp.5-20
    • /
    • 2003
  • The purpose of the research on the noise of educational facilities is to build up pleasant environments by minimizing the influence on the students in the school. This study provides fundamental data for acoustic design by measuring, computer simulation and analyzing the room acoustic characteristics of the lecture room in middle school. For measurement on the factors of room acoustic, RT of lecture room and noise reductions depending on various walls of different structures were measured and analyzed. The lecture system being installed and carried out on the normal lecture room was divided into 4 types-employment of multimedia machines, employment of multimedia machines and loud speakers, employment of loud speaker, and existing verbal speaking-and SPL for each type was measured and analyzed. Based on the measured characteristics of acoustic characteristics for normal lecture room, the problems for environment of noise were understood through computer simulation, applications for improvements of performance for each facility were studied, schemes for improvements of performance by using the effects were presented, necessary fundamental data were secured, and schemes to enhance flexibility on the existing facilities of school against changing educational courses were secured.

한국어 파열자음의 인두내압, 폐쇄기 및 Voice Onset Time(VOT)에 관한 실험적 연구 (The Experimental Study on the Intraoral Pressure, Closure Duration, and Voice Onset Time(VOT) of Korean Stop Consonants)

  • 표화영;심현섭;박헌이;최재영;최성희;안성복;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제10권1호
    • /
    • pp.50-57
    • /
    • 1999
  • A study to get the data of normal stop consonants production as preliminary study for cleft palate patients was performed. Normal Korean native 21 speakers were pronounced $VCV(V=/a/,C=/P/,/{P^1}/,/P^h/,/t/,/{t^1}/,/{t^h}/,/k/,/{k^1}/,/{k^h}/)$ syllables with natural speech rate and intensity. With intrapharyngeal pressure waveforms by pressure sensor in oropharyngeal cavity, amplitude and time duration of intrapharyngeal pressure were analyzed, and with acoustic waveforms and spectrograms, closure duration and VOT were analyzed. As results, the highest amplitude of intrapharyngeal pressure showed in alveolars and heavily aspirated consonants. Velars and unaspirated consonants were higher than bilabials and slightly aspirated ones each, in intrapharyngeal pressure. Bilabilas, alveolars and velars showed similar rise time of intrapharyngeal pressure build-up, but in decay time and total duration time, bilabials were slightly shorter than alveolars and velars, with no statistic significance. In the aspects of tensity, unaspirated consonants showed the longest rise time, heavily aspirated, the second, and slightly aspirated consonants, the shortest, which were also seen in decay time and total duration time. In closure duration, slightly aspirated consonants had the shortest closure duration, and the heavily aspirated ones, the second, and unaspirated consonants showed the longest. In VOT, heavily aspirated consonants showed the longest, slightly aspirated ones, the second and unaspirated ones showed the shortest.

  • PDF

The comparative study of resonance disorders for Vietnamese and Korean cleft palate speakers using nasometer

  • Shin, Yu-Jeong;Kim, Yongsoo;Kim, Hyun-Gi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.9.1-9.5
    • /
    • 2017
  • Background: Nasalance is used to evaluate the velopharyngeal incompetence in clinical diagnoses using a nasometer. The aim of this study is to find the nasalance differences between Vietnamese cleft palate children and Korean cleft palate children by measuring the nasalance of five oral vowels. Methods: Ten Vietnamese cleft palate children after surgery, three Vietnamese children for the control group, and ten Korean cleft palate children after surgery with the same age participated in this experimentation. Instead of Korean control, the standard value of Korean version of the simplified nasometric assessment procedures (kSNAP) was used. Result: The results are as follows: (1) the highest nasalance score among the Vietnamese normal vowels is the low vowel /a/; however, that of Korean normal vowels is the high vowel /i/. (2) The average nasalance score of Korean cleft palate vowels is 18% higher than that of Vietnamese cleft palate vowels. There was a nasalance score of over 45% among the vowels /e/ and /i/ in Vietnamese cleft palate patients and /i/, /o/, and /u/ in Korean cleft palate patients. Conclusion: These different nasalance scores of the same vowels seem to cause an ethnic difference between Vietnamese and Korean cleft palate children.

한국어 원거리 음성의 운율적 특성 (Prosodic Characteristics of Korean Distant Speech)

  • 김선희;김종진;이숙향
    • 한국음향학회지
    • /
    • 제25권3호
    • /
    • pp.137-143
    • /
    • 2006
  • 본 논문의 목적은 한국어 원거리 음성의 운율적 특성을 규명하는 것으로, 36개의 2음절어를 4명의 화자 (여성 화자 2명, 남성 화자 2명)가 원거리 환경과 일반환경에서 발화한 총 288개의 2음절어를 분석대상으로 하였다. 실험 결과 지속시간과 에너지의 경우는 일반 음성에 비하여 원거리 음성의 첫음절에 대한 둘째음절의 비율이 유의미하게 큰 것으로 나타났다. F0 대역폭의 경우에도 원거리 음성에서의 대역폭이 평이 음성에 비해 큰 값을 보였다. 억양 패턴에 있어서는 원거리 음성의 경우에 둘째음절에 'HL%'의 복합 경계성조가 실현되거나 첫음절에 'L+H' 성조가 실현되기도 하였으며 이 두 가지가 한 단어에 모두 실현되는 경우도 있었다.

Phonation Threshold Flow and Phonation Threshold Pressure in Patients with Adductor Spasmodic Dysphonia

  • Choi, Seong-Hee;Jiang, Jack J.;Yun, Bo-Ram;Lee, Ji-Yeoun;Lim, Sung-Eun;Choi, Hong-Shik
    • 말소리와 음성과학
    • /
    • 제2권3호
    • /
    • pp.157-164
    • /
    • 2010
  • This study investigated the characteristics of two aerodynamic indices, PTP (Phonation threshold pressure) and PTF (Phonation threshold flow) in patients with ADSD (adductor spasmodic dysphonia) and to see if two new aerodynamic indices can differentiate between normal and ADSD group. Additionally, PTP and PTF values were compared in terms of overall severity of ADSD in the patient group. The severity of ADSD was rated on a 7-point rating scale by two experienced speech language pathologists. The Kay Elemetrics Phonatory Aerodynamic System (PAS) (Kay Elemetrics Corp., Lincoln Park, NJ) was used to collect PTP and PTF measurements from 16 female normal subjects, 31 female patients with ADSD. Significantly lower PTF values (P< 0.05) were observed in ADSD when compared to those of normal control. Also, significantly lower PTF values in severe ADSD patients (P<.001). However, PTP could not distinguish patients with ADSD from control groups (P=0.119) and among the ADSD groups according to the severity (P=0.177). Consequently, PTF was more sensitive than PTP which might differentiate between normal speakers and ADSD and among different levels of severity within ADSD, suggesting that PTF could be a useful diagnostic parameter to measure the aerodynamic function of ADSD and provide the neurolaryngeal dysfunction in patients with ADSD.

  • PDF