• Title/Summary/Keyword: normal plate

Search Result 679, Processing Time 0.031 seconds

Effect of the magnetism(neodymium magnet) on growth factor receptors of osteoblasts (희토류 자석의 자성이 골모세포 성장인자 수용체의 증가에 미치는 영향에 관한 연구)

  • Lee, Sang-Min;Lee, Sung-Bok;Choi, Boo-Byung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.87-96
    • /
    • 2003
  • The purposes of this study were to find out the optimum intensity of magnetic field where magnetism could promote the activity of osteoblast, and to discover the possibility of clinical application in the areas of dental implants and bone grafts by confirming the effect of clinically increasing bone formation. In this experiment, we used the Neodymium magnet, which had magnetic power six times as strong as the current ones and enabled the resistances against the demagnetization up to 20 to 50 times to be minimized with the size of 1mm in sight. In order to culture cells, a specially designed device was used. It was made to adjust the distance and accordingly to control the intensity of the magnetic field, by placing the cell culture plate in the center with a magnet of 1mm long and thick installed on the both ends. Using MC3T3-E1 cell, a kind of osteoblast-like cell, we cultured, for 24 hours, not only the test group which had been cultured under the magnetic fields with different intensity of 5, 10, 50, 100, 500, and 1000 Gauss, but also the control group excluding the influences of the magnetic field. After observing the cell's form and the density of the culture medium through an inverted microscope, we made a series of proceedings needed for the immunofluoroscence staining, such as fixation, normal serum reaction, primary antibody reaction, and secondary antibody reaction. And with a fluorescence microscope, we observed those-above and compared the frequency of expression of IFG-1 receptor. To make a Western immunoblotting analysis, the cells cultured under the same condition as the above had the procedure of the lysis buffer and the acrylamide gel electrophoresis was carried out. Protein transferred into the nitrocellulose membrane and tested on the primary and the secondary antibody reactions was observed and compared. The results were as follows: When observed through an inverted microscope, the nuclear divisions of the cells under the magnetic field of 10 Gauss were the most active, and the density of the cells could be observed the most enormously. As the result of an immunofluoroscence staining of IGF-1 receptor, the expression of IFG-1 was the most frequently observed under the magnetic field of 10 Gauss. On the other hand, few differences of consideration were made between the test group cultured under the magnetic fields of 5, 500, and 1000 Gauss and the control group. In respect of the expression of IFG-1 receptor, the test group cultured under the magnetic fields of 50 and 100 Gauss were higher than the control group, and lower than that cultured under the magnetic field of 10 Gauss.(p<0.05) According to the Western immunoblotting analysis, the band of IFG-1 receptor which had 85KDa of molecular weight was the darkest. Judging from the above-mentioned results, the growth factor receptor of an osteoblast cell which was an important criterion for the bone formation was increased in maximum under the magnetic field of 10 Gauss. Moreover it was observed that the optimum intensity of magnetic field in which magnetism made the activity of the osteoblast cell increase was about 10 Gauss.

Antimutagenic and Antitumor Effects of Adenophora triphylla Extracts (잔대 추출물들의 항돌연변이 및 항종양 효과)

  • Ham, Young-An;Choi, Hyun-Jin;Kim, Soo-Hyun;Chung, Mi-Ja;Ham, Seung-Shi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • This study was carried out to investigate the mutagenic, antimutagenic, cytotoxicity and antitumor effects of Adenophora triphylla (AT). AT was extracted with 70% ethanol and then further fractionated to hexane, chloroform, ethyl acetate, butanol and water. Antimutagenic, cytotoxicity and antitumor effects of AT extracts were measured by using Ames test, SRB method, and the tumor growth inhibition test. AT extracts did not show any mutagenicity in the Ames test; however, 70% ethanol extracts and its fractions had strong antimutagenic effects against mutation induced by N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) and 4-nitroquinoline-1-oxide (4NQO). The ethyl acetate fraction of AT (200 ${\mu}g$/plate) showed approximately 66.5% inhibitory effect on the mutagenesis induced by 4NQO against TA98 strain, whereas 83.3% and 75.1% inhibitions were observed on the mutagenesis induced by MNNG and 4NQO against TA100 strain. In anticancer effects, the cytotoxicity of AT extract and its fractions against cancer cell lines including human cervical adenocarcinoma (HeLa), human hepatocellular carcinoma (Hep3B), human breast adenocarcinoma (MCF-7), human gastric carcinoma (AGS), human lung carcinoma (A549) and transformed primary human embryo kidney (293) were investigated. The treatment of 1 mg/mL AT ethyl acetate faction had the highest cytotoxicity of 79.9%, 74.9%, 66.0%, 71.0% and 74.3% against HeLa, Hep3B, MCF-7, AGS and A549 cells, respectively. In contrast, the extract and its fractions showed only $3{\sim}36%$ cytotoxicity for a normal human kidney cell line (293). In vivo anti-cancer effect of Adenophora triphylla extract was tested using Balb/c mice transplanted sarcoma-180 cells. Adenophora triphylla ethyl acetate fraction showed the highest inhibition rate of 37.2% at the 50 mg/kg concentration.

Application of the Homogenization Analysis to Calculation of a Permeability Coefficient (투수계수 산정을 위한 균질화 해석법의 적응)

  • 채병곤
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2004
  • Hydraulic conductivity along rock fracture is mainly dependent on fracture geometries such as orientation, aperture, roughness and connectivity. Therefore, it needs to consider fracture geometries sufficiently on a fracture model for a numerical analysis to calculate permeability coefficient in a fracture. This study performed new type of numerical analysis using a homogenization analysis method to calculate permeability coefficient accurately along single fractures with several fracture models that were considered fracture geometries as much as possible. First of all, fracture roughness and aperture variation due to normal stress applied on a fracture were directly measured under a confocal laser scaning microscope (CLSM). The acquired geometric data were used as input data to construct fracture models for the homogenization analysis (HA). Using the constructed fracture models, the homogenization analysis method can compute permeability coefficient with consideration of material properties both in microscale and in macroscale. The HA is a new type of perturbation theory developed to characterize the behavior of a micro inhomogeneous material with a periodic microstructure. It calculates micro scale permeability coefficient at homogeneous microscale, and then, computes a homogenized permeability coefficient (C-permeability coefficient) at macro scale. Therefore, it is possible to analyze accurate characteristics of permeability reflected with local effect of facture geometry. Several computations of the HA were conducted to prove validity of the HA results compared with the empirical equations of permeability in the previous studies using the constructed 2-D fracture models. The model can be classified into a parallel plate model that has fracture roughness and identical aperture along a fracture. According to the computation results, the conventional C-permeability coefficients have values in the range of the same order or difference of one order from the permeability coefficients calculated by an empirical equation. It means that the HA result is valid to calculate permeability coefficient along a fracture. However, it should be noted that C-permeability coefficient is more accurate result than the preexisting equations of permeability calculation, because the HA considers permeability characteristics of locally inhomogeneous fracture geometries and material properties both in microscale and macroscale.

$^{99m}Tc$-Glucarate Uptake in Ischemic Tissue of Experimental Models of Cerebral Ischemia (실험적 뇌허혈증 모델에서 허혈 조직의 $^{99m}Tc$-glucarate 섭취)

  • Jeong, Jae-Min;Kim, Young-Ju;Choi, Seok-Rye;Kim, Chae-Kyun;Mar, Woong-Chun;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.484-492
    • /
    • 1996
  • To detect ischemic tissue in experimental model of cerebral ischemia made by middle cerebral artery(MCA)-occlusion, we acquired triple image of $^{99m}Tc$-glucarate, [$^{18}F$]fluoro-deoxyglucose (FDG), and 2,3,5- triphenyltetrazolium (TTC) staining. We made cerebral infarction either with reperfusion (after occlusion of 2 hours) or without reperfusion in 10 Sprague-Dawley rats by inserting thread to MCA through internal carotid artery. After 22 hours, we injected 740 MBq of $^{99m}Tc$-glucarate and 55.5 MBq of [$^{18}F$]FDG through tail vein. Each 1 mm slice of rat brains was frozen and exposed to imaging plate for 20 minutes in freezer to get an [$^{18}F$]FDG image. After 20 hours enough to fade radioactivity of [$^{18}F$]FDG, the slices were again imaged by BAS1500 for $^{99m}Tc$-glucarate uptake. Finally, these brain tissues were stained with TTC. Semi-quantitative visual analysis was done by grading 0 to 3 points according to the degree of uptakes($^{99m}Tc$-glucarate) and decreased uptakes([$^{18}F$]FDG and TTC). Ten rats survived with neurologic symptoms. TTC staining confirmed the development of infarction. The size of the infarction was relatively larger in the group without reperfusion. [$^{18}F$]FDG images were similar to TTC-stained images. However, we found regions with intermediate uptake which were not stained with TTC. We found regions with intermediate [$^{18}F$]FDG uptake where TTC staining was normal. $^{99m}Tc$-glucarate uptake was round only in TTC non-stained region. In the TTC stained regions, there were no uptake of $^{99m}Tc$-glucarate. We could not find clear relation between $^{99m}Tc$-glucarate uptake with [$^{18}F$]FDG uptake. This was partly because percent uptake of $^{99m}Tc$-glucarate was so small (less than 1 percent of injected dose) and because there were quite heterogeneity of patterns of [$^{18}F$]FDG uptake and TTC. With these findings, we could conclude that $^{99m}Tc$-glucarate were taken up only in part of ischemic tissues which were proven to be nonviable. The establishment of MCA-occluded rat model with or without reperfusion and triple imaging for $^{99m}Tc,\;^{18}F$ and TTC helped the characterization of $^{99m}Tc$-glucarate uptakes. Further work is needed to clarify the meaning or diversities or [$^{18}F$]FDG and TTC and their relation with $^{99m}Tc$-glucarate.

  • PDF

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident (방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구)

  • Park, Byeong Ryong;Ha, Wi-Ho;Park, Sunhoo;Lee, Jin Kyeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.194-201
    • /
    • 2015
  • We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by $^{137}Cs$ gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity ($R^2$ > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

Finite element analysis of the effects of mouthguard produced by combination of layers of different materials on teeth and jaw (다양한 물성을 혼용하여 제작된 구강보호장치가 치아 및 악골에 미치는 영향)

  • So, Woong-Seob;Lee, Hyun-Jong;Choi, Woo-Jin;Hong, Sung-Jin;Ryu, Kyung-Hee;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.324-332
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the stress distribution of teeth and jaw on load by differentiating property of materials according to each layer of widely used mouthguard. Materials and methods: A Korean adult having normal cranium and mandible was selected to examine. A customized mouthguard was constructed by use of DRUFOMAT plate and DRUFOMAT-TE/-SQ of Dreve Co. according to Signature Mouthguard system. The cranium was scanned by means of computed tomography with 1mm interval. It was modeled with CANTIBio BIONIX/Body Builder program and simulated and interpreted using Alter HyperMesh program. The mouthguard was classified as follows according to the layers. (1) soft guard (Bioplast)(SG) (2) hard guard (Duran)(HG) (3) medium guard (Drufomat)(MG) (4) soft layer + hard layer (SG + HG) (5) hard layer + soft layer (HG + SG) (6) soft layer + hard layer + soft layer (SG + HG + SG) (7) hard layer + soft layer + hard layer (HG + SG + HG) The impact locations on mandible were gnathion, the center of inferior border, and the anterior edge of gonial angle. And the impact directions were oblique ($45^{\circ}$). The impact load was 800 N for 0.1 sec. The stress distribution was measured at maxillary teeth, TMJ and maxilla. The statistics were conducted using Repeated ANOVA and in case of difference, Duncan test was used as post analysis. Results: In teeth and maxilla, the mouthguard contacting soft layer of mandibular teeth presented lowest stress measure and, in contrast, in condyle, the mouthguard contacting hard layer of mandibular teeth presented lowest stress measure. Conclusion: For all impact directions, soft layer + hard layer + soft layer, the mouthguard with three layers which the hard layer is sandwiched between two soft layers, showed relatively even distribution of stress in impact.

Structural Behavior of the Buried flexible Conduits in Coastal Roads Under the Live Load (활하중이 작용하는 해안도로 하부 연성지중구조물의 거동 분석)

  • Cho, Sung-Min;Chang, Yong-Chai
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.323-328
    • /
    • 2002
  • Soil-steel structures have been used for the underpass, or drainage systems in the road embankment. This type of structures sustain external load using the correlations with the steel wall and engineered backfill materials. Buried flexible conduits made of corrugated steel plates for the coastal road was tested under vehicle loading to investigate the effects of live load. Testing conduits was a circular structure with a diameter of 6.25m. Live-load tests were conducted on two sections, one of which an attempt was made to reinforce the soil cover with the two layers of geo-gird. Hoop fiber strains of corrugated plate, normal earth pressures exerted outside the structure, and deformations of structure were instrumented during the tests. This paper describes the measured static and dynamic load responses of structure. Wall thrust by vehicle loads increased mainly at the crown and shoulder part of the conduit. However additional bending moment by vehicle loads was neglectable. The effectiveness of geogrid-reinforced soil cover on reducing hoop thrust is also discussed based on the measurements in two sections of the structure. The maximum thrusts at the section with geogrid-reinforced soil cover was 85-92% of those with un-reinforced soil cover in the static load tests of the circular structure; this confirms the beneficial effect of soil cover reinforcement on reducing the hoop thrust. However, it was revealed that the two layers of geogrid had no effect on reducing the overburden pressure at the crown level of structure. The obtained values of DLA decrease approximately in proportion to the increase in soil cover from 0.9m to 1.5m. These values are about 1.2-1.4 times higher than those specified in CHBDC.

Development of Prediction Model for Capsaicinoids Content in Red-Pepper Powder Using Near-Infrared Spectroscopy - Particle Size Effect (근적외선 스펙트럼을 이용한 고춧가루의 캡사이신 함량 예측 모델 개발 - 입자의 영향)

  • Mo, Changyeun;Kang, Sukwon;Lee, Kangjin;Lim, Jong-Guk;Cho, Byoung-Kwan;Lee, Hyun-Dong
    • Food Engineering Progress
    • /
    • v.15 no.1
    • /
    • pp.48-55
    • /
    • 2011
  • In this research, the near-infrared absorption from 1,100-2,300 nm was used to measure the content of capsaicinoids in the red-pepper powder by using the Acousto-optic tunable filters (AOTF) spectrometer with sample plate and sample rotating unit. Non-spicy red-pepper samples from one location (Younggwang-gun. Korea) were mixed with spicy one (var. Chungyang) to make samples separated by particle size (below 0.425 mm, 0.425-0.71 mm, and 0.71- 1.4 mm). The Partial Least Squares Regression (PLSR) model to predict the capsaicinoid content on particle sizes was developed with measured spectra by AOTF spectrometer and used to analyze the amount of capsaicinoids by HPLC. The PLSR Model of red-pepper powder of below 0.425 mm, 0.425-0.71 mm, and 0.71-1.4 mm with cross validation had ${R_V}^2$ = 0.948-0.979 and Standard Error of Prediction (SEP) = 6.56-7.94 mg%. The prediction error of smaller particle size of red-pepper powder was low. The best PLSR model was found in pretreatment of Range Normalization, Standard Normal Variate, and 1st Derivatives of red-pepper powder of below 1.4 mm with cross validation, having ${R_V}^2$ = 0.959 and SEP = 8.82 mg%.