• Title/Summary/Keyword: normal flow

Search Result 1,928, Processing Time 0.027 seconds

Deployment and Performance Analysis of Nation-wide OpenFlow Networks over KREONET (KREONET 기반의 광역 규모 오픈플로우 네트워크 구축 및 성능 분석)

  • Hong, Won-Taek;Kong, Jong-Uk;Chung, Jin-Wook
    • The KIPS Transactions:PartC
    • /
    • v.18C no.6
    • /
    • pp.423-432
    • /
    • 2011
  • Recently, OpenFlow has been paid attention to as a fundamental technology which provides a function of virtualization and programmability in network. In Korea, deployment of OpenFlow networks in campuses and the interconnection between them through tunneling in layer 3 has been performed. However, the performance of the interconnected networks is decreased due to delay in IP layer. In this paper, we design and deploy nation-wide, not local, OpenFlow networks in a pure layer 2 environment over KREONET. After that, we do end-to-end Round-trip Time measurements and TCP/UDP performance tests in OpenFlow and normal networks, and do comparison and analysis on the test results. The results show that the nation-wide OpenFlow networks provide equal performance to normal networks except for the initial packet loss for UDP streaming. In regards to the performance decrease due to early UDP packet loss, we can mitigate it by implementing exceptional procedures in a controller which deal with the same continuous "Packet_in" events.

The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility (하나로 유동모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

Performance prediction of mixed-flow pumps (혼류 펌프의 성능 해석)

  • O, Hyeong-U;Yun, Ui-Su;Jeong, Myeong-Gyun;Ha, Jin-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.1
    • /
    • pp.70-78
    • /
    • 1998
  • The present study has tested semi-empirical loss models for a reliable performance prediction of mixed-flow pumps with four different specific speeds. In order to improve the predictive capabilities, this paper recommends a new internal loss model and a modified parasitic loss model. The prediction method presented here is also compared with that based on two-dimensional cascade theory. Predicted performance curves by the proposed set of loss models agree fairly well with experimental data for a variety of mixed-flow pumps in the normal operating range, but further studies considering 'droop-like' head performance characteristic due to flow reversal in mixed-flow impellers at low flow range near shut-off head are needed.

Mean Streamline Analysis for Performance Prediction of Cross- Flow Fans

  • Kim, Jae-Won;Oh, Hyoung-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1428-1434
    • /
    • 2004
  • This paper presents the mean streamline analysis using the empirical loss correlations for performance prediction of cross-flow fans. Comparison of overall performance predictions with test data of a cross-flow fan system with a simplified vortex wall scroll casing and with the published experimental characteristics for a cross-flow fan has been carried out to demonstrate the accuracy of the proposed method. Predicted performance curves by the present mean streamline analysis agree well with experimental data for two different cross-flow fans over the normal operating conditions. The prediction method presented herein can be used efficiently as a tool for the preliminary design and performance analysis of general-purpose cross-flow fans.

In vitro study of downstream flow passing through heart valve prostheses (인공 심장판막 하류 유동의 in vitro 연구)

  • Kim Hyoung-Bum;Lanning Craig
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • The left ventricular filling flow is now considered as an indicator which can be used for early diagnosing of cardiovascular diseases. Because the understanding of left ventricular flow physics is critical for this purpose, the downstream flow characteristics of the artificial heart valve are investigated using particle image velocimetry (PIV) method. In this study, we investigated the wake characteristics of flows passing through three different artificial valves (St.Jude medical bileaflet mechanical valve. Bjork-Shiley monostrut mechanical valve and St.Jude medical Biocor bio valve). The downstream flow field has remarkably altered according to the different valves. SJM MHV has the flow field similar to the pulsating circular jet and BS MHV has oblique pulsating jet. SJM BHV shows the similar flow field of clinical data of normal heart.

  • PDF

Warm-Start of Interior Point Methods for Multicommodity Network Flow Problem (다수상품 유통문제를 위한 내부점 방법에서의 Warm-Start)

  • 임성묵;이상욱;박순달
    • Korean Management Science Review
    • /
    • v.21 no.1
    • /
    • pp.77-86
    • /
    • 2004
  • In this paper, we present a methodology for solving the multicommodity network flow problems using interior point methods. In our method, the minimum cost network flow problem extracted from the given multicommodity network flow problem is solved by primal-dual barrier method in which normal equations are solved partially using preconditioned conjugate gradient method. Based on the solution of the minimum cost network flow problem, a warm-start point is obtained from which Castro's specialized interior point method for multicommodity network flow problem starts. In the computational experiments, the effectiveness of our methodology is shown.

Flow Analysis for Design Modification of Marine Generator Fan (박용 발전기 냉각 팬 설계변경에 따른 유동해석)

  • Kim, Hong-Won;Seol, Sin-Su;Ha, Ji-Soo;Kim, Jin-O
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.840-844
    • /
    • 2003
  • A study for increase of fan flow rate by geometric modification has been conducted to decrease temperature rise of marine generator inner part. Through experiment of a real product, a performance curve for various flow resistances was obtained. Flow analyses for each cases were done by using commercial code-FLUENT and the results were very similar to experimental data (0.7% deviation at normal operating condition). Through flow analysis results for various design geometric modification, a scroll type fan was adopted as a best design geometry with 100Pa more pressure and 22% more flow rate than original fan.

  • PDF

Ultrasonic Transducers for Measuring Both Flow Velocity and Pipe Thickness (유속 및 파이프 두께 측정 겸용 초음파 트랜스듀서)

  • Kim, Ju Wan;Piao, Chunguang;Kim, Jin Oh;Park, Doo-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.559-567
    • /
    • 2015
  • The paper deals with an ultrasonic transducer invented for measuring both flow velocity and pipe thickness. The structure of the transducer is based on the conventional transducers for measuring flow velocity by obliquely transmitting ultrasonic waves to the flow direction. The transducer additionally generates ultrasonic waves transmitting vertically to a pipe for measuring pipe thickness. By measuring flow velocity with the invented transducer and a conventional oblique-incidence transducer and comparing their results, the accuracy of the flow velocity measurement of the invented one was evaluated. By measuring specimen thickness with the invented transducer and a conventional normal-incidence transducer and comparing their results, the accuracy of the thickness measurement of the invented one was evaluated.

An Experimental Research on Changes of Properties in Flow by Slump Flow Type Concrete Mix Design Adjustment of the Way according to the Various Gmax Size (굵은 골재 최대치수 변경에 따른 슬럼프 플로 타입 콘크리트의 배합조정방법별 유동특성변화에 대한 실험적 연구)

  • Kwon, Hae-Won;Seo, Il;Lee, Jin-Woo;Park, Hee-Gon;Lee, Jae-Sam;Lee, Jong-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.67-68
    • /
    • 2010
  • Recently, there were not enough studies regarding the mix adjustment and changes of normal physical properties of slump flow type concrete in domestically. Therefore in this paper, it is aimed securing the fundamental data about flow its mix design method by experimental research. The experiment includes the adjustment of the way for slump flow type concrete by the variation of size of coarse aggregate. In the result, it is advisable raising the ratio of fine aggregate and unit water amount by considering the specific surface when increasing the Gmax size.

  • PDF

Instability of pipes and cables in non-homogeneous cross-flow

  • Riera, Jorge D.;Brito, J.L.V.
    • Wind and Structures
    • /
    • v.1 no.1
    • /
    • pp.59-66
    • /
    • 1998
  • The vibrations of bodies subjected to fluid flow can cause modifications in the flow conditions, giving rise to interaction forces that depend primarily on displacements and velocities of the body in question. In this paper the linearized equations of motion for bodies of arbitrary prismatic or cylindrical cross-section in two-dimensional cross-flow are presented, considering the three degrees of freedom of the body cross-section. By restraining the rotational motion, equations applicable to circular tubes, pipes or cables are obtained. These equations can be used to determine stability limits for such structural systems when subjected to non uniform cross-flow, or to evaluate, under the quasi static assumption, their response to vortex or turbulent excitation. As a simple illustration, the stability of a pipe subjected to a bidimensional flow in the direction normal to the pipe axis is examined. It is shown that the approach is extremely powerful, allowing the evaluation of fluid-structure interaction in unidimensional structural systems, such as straight or curved pipes, cables, etc, by means of either a combined experimental-numerical scheme or through purely numerical methods.