• Title/Summary/Keyword: normal flow

Search Result 1,928, Processing Time 0.033 seconds

Enhancement of Airfoil Post-Stall Characteristics via a Jet Blowing (제트 블로잉에 의한 에어포일의 실속후 특성 향상)

  • Lee, Ki-Young;Chung, Heong-Seok;Cho, Dong-Hyun;Sohn, Myong-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.188-197
    • /
    • 2007
  • Active flow control, in the form of steady and unsteady momentum injection via jet blowing was studied. A jet was obtained by pressing a plenum inside the airfoil and ejecting flow out of a thin slot. The normal and drag forces were measured with leading edge or trailing edge blowing Jet and compared with the results obtained with no blowing. The blowing jet has been shown to improve the aerodynamic performance of the airfoil. The steady jet proved more effective than pulsating jet in these experimental conditions. Furthermore for the case of leading edge steady blowing jet, the alleviation of non-linearity in the normal force curve slope can be seen at higher angles of attack. No effective trailing edge jet was observed in this highly separated flow. This shows that the stall control is highly depends on the characteristics of the boundary layer near the jet slot.

An Experiments Analysis of Comparison of Flow Gradients Across Disposable Arterial Perfusion Cannulas (일회용 각종 송혈관의 관류압차에 대한 비교실험)

  • Kim, Yo-Han;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.18-24
    • /
    • 1986
  • The mean perfusion pressure produced by 20 different design and size of disposable aortic perfusion cannulas [size range: 18F to 20F] at flow rates of 1 to 5 L/min was compared. A roller pump with perfusion tubing 10mm in inner diameter was used with a mixture of 0.9% normal saline and 100% glycerin [mixing ratio of 6.72:13.28] to make the viscosity as normal blood in 20oC as the test solution. Line pressure in these cannulas at a flow rate of 3L/min ranged from 13.2$\pm$4.47 to 157$\pm$1 34 mmHg in a case of absence of resistance, and from 11.4$\pm$1.14 to 227.2$\pm$4.47 mmHg in a case of presence of resistances 14 cannulas had gradients of less than 100Hg at a flow rate of 3L/min and 9 cannulas less than 100mmHg at 4L/min. The following results were obtained from this experimental study: .1] A wide range of line pressure was observed in disposable aortic perfusion cannulas currently in clinical use; 2] Some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; 3] Both the material and design affect function, with some designs safer than others. Cardiac surgeons should base the choice of aortic perfusion cannula on the best performance and safest design available to avoid cannula-related problems during operation.

  • PDF

A Numerical Study on Flow and Heat Transfer Characteristics of Supersonic Second Throat Exhaust Diffuser for High Altitude Simulation (고고도 모사용 초음속 이차목 디퓨저의 유동 및 열전달 특성에 대한 수치적 연구)

  • Yim, Kyungjin;Kim, Hongjip;Kim, Seunghan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.70-78
    • /
    • 2014
  • A numerical study has been conducted to investigate flow and heat transfer characteristics of supersonic second throat exhaust diffusers for high altitude simulation. By changing pressure and configuration, flow and cooling characteristics of the diffuser have been studied. At the normal operation of the diffuser, there were high temperature regions over 3,000 K without cooling, especially near wall and in subsonic diffuser part. If the cooling system of the diffuser is added, flow velocity is increased due to the cooled wall temperature.

Flow based Sequential Grouping System for Malicious Traffic Detection

  • Park, Jee-Tae;Baek, Ui-Jun;Lee, Min-Seong;Goo, Young-Hoon;Lee, Sung-Ho;Kim, Myung-Sup
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3771-3792
    • /
    • 2021
  • With the rapid development of science and technology, several high-performance networks have emerged with various new applications. Consequently, financially or socially motivated attacks on specific networks have also steadily become more complicated and sophisticated. To reduce the damage caused by such attacks, administration of network traffic flow in real-time and precise analysis of past attack traffic have become imperative. Although various traffic analysis methods have been studied recently, they continue to suffer from performance limitations and are generally too complicated to apply in existing systems. To address this problem, we propose a method to calculate the correlation between the malicious and normal flows and classify attack traffics based on the corresponding correlation values. In order to evaluate the performance of the proposed method, we conducted several experiments using examples of real malicious traffic and normal traffic. The evaluation was performed with respect to three metrics: recall, precision, and f-measure. The experimental results verified high performance of the proposed method with respect to first two metrics.

Relationship between the Flow data on the Unit Watersheds and on the Stream Flow Monitoring Network (수질오염총량관리 단위유역 유량자료와 하천유량 측정망 자료의 연계성 분석)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.55-65
    • /
    • 2013
  • It is very difficult to apply stream flow data directly to the management of Total Maximum Daily Loads because there are some differences between the unit watershed and the stream flow monitoring network in their characteristics such as monitoring locations and its intervals. Flow duration curve can be developed by linking the daily flow data of stream monitoring network to 8 day interval flow data of the unit watershed. This study investigated the current operating conditions of the stream flow monitoring network and the flow relationships between the unit watershed and the stream flow monitoring network. Criteria such as missing and zero value data, and correlation coefficients were applied to select the stream flow reference sites. The reference sites were selected in 112 areas out of 142 unit watersheds in 4 river basins, where the stream flow observations were carried out in relatively normal operating conditions. These reference sites could be utilized in various ways such as flow variation analysis, flow duration curve development and so on for the management of Total Maximum Daily Loads.

A Study of Literature Review on Needling Sensation and the Flow of the Needling Sensation (침감(鍼感) 및 침향(鍼響)에 대한 문헌적(文獻的) 고찰(考察))

  • Kim, Sung-chul
    • Journal of Acupuncture Research
    • /
    • v.18 no.3
    • /
    • pp.201-214
    • /
    • 2001
  • Objective : To study needling sensation and the flow of the needling sensation the ancient and the present literatures were reviewed. Results : 1. The needling sensation was getting the Qi and a normal reaction of acupuncture. 2. The flow of the needling sensation was promoted the Qi and normalized the flow of the Qi 3. The needling sensation of a patient expressed soreness, distension, heaviness, numbness, tingling, flushing, fervor, chill, itching, and so forth. 4. The needling sensation of a patient expressed simple or complex syndrome. 5. The needling sensation of a doctor expressed objectively more than the needling sensation of a patient in the hand feeling of a doctor. 6. The doctor was compared good needling sensation and bad needling sensation. 7. The needling sensation and the flow of the needling sensation were processed continuously. 8. The needling sensation and the flow of the needling sensation were connected with a nervous system and expressed variously in the anatomical structure and hand acupuncture tenchnique.

  • PDF

Flow Rate Characteristics of Two Parallel Pumping System (두 대의 펌프가 병렬로 설치되는 계통에서의 유량 특성)

  • Park, Y.C.;Chi, D.Y.;Seo, K.W.;Yoon, H.G.;Park, J.G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.579-586
    • /
    • 2011
  • During a reactor normal operation, a primary coolant was designed to remove the fission reaction heat of the reactor. When one pump is failure and the other pump shall supply the cooling water to cool the reduced power, it is necessary to estimate how much flow will be supplied to cool the reactor. We carried a flow net work analysis for two parallel pumping system as based on the piping net work of the primary cooling system in HANARO. As result, it is estimated that the flow of one pump increased than the rated flow of the pump below the cavitation critical flow.

  • PDF

Water quality forecasting on upstream of chungju lake by flow duration (충주호 상류지역의 유황별 장래수질예측)

  • 이원호;한양수;연인성;조용진
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • In order to define about concern with discharge and water-quality, it is calculated drought flow, low flow, normal flow and wet flow in Chungju watershed from flow duration analysis. Water quality modeling study is performed for forecasting at upstream of Chungju lake. It is devided method of modeling into before and after the equipment of environmental treatment institution. And it is estimated the change of water quality. Before the equipment of environmental treatment, BOD concentration is increased from 23000 to 2006 years at all site and decrease on 2012 years. The rate of increasing BOD concentration is showed height between 2000 years and 2003 years most of all site. And after the equipment of environmental treatment, it is showed first grade of BOD water quality in most of sample site beside Jucheon river. The result of water quality modeling using drought flow showed that a lot of pollution occurred. And water quality using wet flow is good, so much discharge make more improve water quality than little discharge.

Effects of Xingjian(LR2),Shaofu(HT8) by Reinforcing and Reducing on the Regional Cerebral Blood Flow and Mean Arterial Blood Pressure in Normal Rats (행간(行間)·소부(少府) 보사침법(補瀉鍼法)이 국소뇌혈류량(局所腦血流量) 및 평균혈압(平均血壓)에 미치는 영향(影響))

  • Shin, Jeong-cheol;Ryu, Chung-ryul;Cho, Myeng-rae
    • Journal of Acupuncture Research
    • /
    • v.20 no.6
    • /
    • pp.190-200
    • /
    • 2003
  • Objective: The purpose of this study is to examine influences by the order, Reduction and Reinforcement in Acupuncture on cerebral hemodynamics [regional cerebral blood flow(rCBF) and mean arterial blood pressure(MABP)] in normal rats. Methods: This experiments was to to investigate eath other changes of rCBF and MABP at Xingjian(LR2)(1st) Shaofu(HT8)(2nd) Reduction, Xingjian(LR2)(1st) Shaofu(HT8)(2nd) Reinforcement, Shaofu(HT8)(1st) Xingjian(LR2)(2st) Reduction and Shaofu(HT8)(1st) Xingjian(LR2)(2st) Reduction in Acupuncture. Results: 1. LR2(1st) HT8(2nd) Reduction in Acupuncture was decreased rCBF and MABP in compared with normal condition. 2. LR2(1st) HT8(2nd) Reinforcement in Acupuncture was significantly decreased rCBF, and was decreased MABP in compared with normal condition. 3. HT8(1st) LR2(2st) Reduction in Acupuncture was decreased rCBF during acupuncture but was recovered rCBF after with-drawing of the neddle. 4. HT8(1st) LR2(2st) Reduction in Acupuncture was decreased MABP during acupuncture and after withdrawing of the neddle. 5. HT8(1st) LR2(2st) Reinforcement in Acupuncture was significantly increased rCBF during acupuncture and 30min after withdrawing of the neddle. 6. HT8(1st) LR2(2st) Reinforcement in Acupuncture was decreased MABP during acupuncture, but was recovered MABP after withdrawing of the neddle. Conclusions: I suggested that LR2 HT8 Reduction in Acupuncture and LR2 HT8 Reinforcement in Acupuncture cause a diverse response of cerebral hemodynas.

  • PDF

Effects of Daedon($LR_1$) Supplementation and Eumgok($KI_{10}$) Draining on Changes of Cerebral Hemodynamics in Normal Rats (대돈(大敦) 보(補) 음곡(陰谷) 사(瀉) 자침(刺鍼)이 정상 흰쥐의 뇌혈류력학(腦血流力學) 변화(變化)에 미치는 영향(影響))

  • Jung, Ho-Suk;Ryu, Chung-Ryeol;Cho, Myung-Rae
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.31-40
    • /
    • 2009
  • Objectives: The purpose of this study is to investigate the effects of Daedon($LR_1$) Supplementation and Eumgok($KI_{10}$) Draining on changes of cerebral blood flow in normal rats. Methods : Regional cerebral blood flow(rCBF) and mean arterial blood pressure(MABP) in normal rats are observed, and those mechanisms were also investigated with pre-treatment of indomethacin (IDM) and methylene blue(MTB) each. Results : In this study, $LR_1$ supplementation and $KI_{10}$ draining elevated level of rCBF after 30 min, but MABP level was lowered at 30 min, then recovered toward normal level. Pre-treatment with indomethacin (IDM), an inhibitor of cyclooxygenase, inhibited increase of rCBF effectively, and pre-treatment with methylene blue(MTB), an inhibitor of guanylate cyclase, also inhibited increase of rCBF levels. On the other hand pre-treatment with IDM or MTB did not affect MABP levels. Conclusions : In conclusion, these results suggest that $LR_1$ supplementation and $KI_{10}$ draining can increase rCBF, and the mechanisms are thought to be related to both of cyclooxygenase and Guanylate cyclase pathways.

  • PDF