• 제목/요약/키워드: noninvasive approach

검색결과 51건 처리시간 0.021초

핵의학적 심혈관 촬영술에 의한 좌우 심단락의 진단 : 시간-방사능 곡선의 분석 (Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Activity Curves)

  • 김옥화;박용휘;김치경
    • 대한핵의학회지
    • /
    • 제21권2호
    • /
    • pp.155-165
    • /
    • 1987
  • The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis-of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intra cardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs, intracardiac shunt could be differenciated from extracardiac shunts.

  • PDF

비색 MOF 가스센서 어레이 기반 고정밀 질환 VOCs 바이오마커 검출을 위한 머신비전 플랫폼 (Machine Vision Platform for High-Precision Detection of Disease VOC Biomarkers Using Colorimetric MOF-Based Gas Sensor Array)

  • 이준영;오승윤;김동민;김영웅;허정석;이대식
    • 센서학회지
    • /
    • 제33권2호
    • /
    • pp.112-116
    • /
    • 2024
  • Gas-sensor technology for volatile organic compounds (VOC) biomarker detection offers significant advantages for noninvasive diagnostics, including rapid response time and low operational costs, exhibiting promising potential for disease diagnosis. Colorimetric gas sensors, which enable intuitive analysis of gas concentrations through changes in color, present additional benefits for the development of personal diagnostic kits. However, the traditional method of visually monitoring these sensors can limit quantitative analysis and consistency in detection threshold evaluation, potentially affecting diagnostic accuracy. To address this, we developed a machine vision platform based on metal-organic framework (MOF) for colorimetric gas sensor arrays, designed to accurately detect disease-related VOC biomarkers. This platform integrates a CMOS camera module, gas chamber, and colorimetric MOF sensor jig to quantitatively assess color changes. A specialized machine vision algorithm accurately identifies the color-change Region of Interest (ROI) from the captured images and monitors the color trends. Performance evaluation was conducted through experiments using a platform with four types of low-concentration standard gases. A limit-of-detection (LoD) at 100 ppb level was observed. This approach significantly enhances the potential for non-invasive and accurate disease diagnosis by detecting low-concentration VOC biomarkers and offers a novel diagnostic tool.

Efficacy of Light and Odor Barriers in Controlling Insect Pest Evasion by Modulating Light and Gas Environments

  • Jahyun Na;Jae Hun Yoo;Yong-Hoo Kwon;Sanghun Yeo;Gyung Deok Han
    • 한국환경과학회지
    • /
    • 제33권8호
    • /
    • pp.575-581
    • /
    • 2024
  • Insect pests are a significant threat to stored crops and can lead to considerable economic losses and reduced crop quality. Traditional pest control methods often involve chemical treatments, which have adverse environmental and health effects. This study evaluated the effectiveness of controlling the environment using LED lighting and plant-derived odor barriers as a dual strategy for insect pest control. The storage environment was altered using LED lights that emitted specific wavelengths (580-585 nm) and by reducing other wavelengths (300-500 nm). This light environment was combined with an insect odor barrier derived from Cinnamomum verum, Illicium verum, and Artemisia annua, and their duel impact on the behavior and frequency of insect pests under real storage conditions was determined. The findings revealed significant changes in the frequencies of various insect orders, indicating differential responses to light wavelengths and odor barriers. Notably, the introduction of an anti-insect light and odor barrier environment reduced Diptera and Hemiptera frequencies, which could potentially reduce pest intrusion. The results underscore the potential use of integrated light and odor barriers as a noninvasive and environmentally friendly approach to pest management. This study identifies the specific wavelengths and odor combinations that effectively deter insect pests and contribute to the development of more efficient and sustainable pest control methods. It also highlights the importance of understanding insect behavior and frequency changes in response to novel deterrent strategies.

유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가 (Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation)

  • 심수영;유호석;김한별;정재훈;이상준;김성민;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

신경계 질환에서 근적외선분광분석법의 적용: 기립불내증을 중심으로 (Application of Near-Infrared Spectroscopy in Neurological Disorders: Especially in Orthostatic Intolerance)

  • 김유환;백승호;;석흥열;전남준;김법민;김병조
    • 대한신경과학회지
    • /
    • 제35권1호
    • /
    • pp.8-15
    • /
    • 2017
  • Near-infrared spectroscopy (NIRS), a noninvasive optical method, utilizes the characteristic absorption spectra of hemoglobin in the near-infrared range to provide information on cerebral hemodynamic changes in various clinical situations. NIRS monitoring have been used mainly to detect reduced perfusion of the brain during orthostatic stress for three common forms of orthostatic intolerance (OI); orthostatic hypotension, neurally mediated syncope, and postural orthostatic tachycardia syndrome. Autonomic function testing is an important diagnostic test to assess their autonomic nervous systems for patients with symptom of OI. However, these techniques cannot measure dynamic changes in cerebral blood flow. There are many experimentations about study of NIRS to reveal the pathophysiology of patients with OI. Research using NIRS in other neurologic diseases (stroke, epilepsy and migraine) are ongoing. NIRS have been experimentally used in all stages of stroke and may complement the established diagnostic and monitoring tools. NIRS also provide pathophysiological approach during rehabilitation and secondary prevention of stroke. The hemodynamic response to seizure has long been a topic for discussion in association with the neuronal damage resulting from convulsion. One critical issue when unpredictable events are to be detected is how continuous NIRS data are analyzed. Besides, NIRS studies targeting pathophysiological aspects of migraine may contribute to a deeper understanding of mechanisms relating to aura of migraine. NIRS monitoring may play an important role to trend regional hemodynamic distribution of flow in real time and also highlights the pathophysiology and management of not only patients with OI symptoms but also those with various neurologic diseases.

줄기세포 연구를 위한 급성신장손상 모델 (Acute Kidney Injury Models: Focus on the Therapeutic Effects of Stem Cell in Preclinical Approach)

  • 남현숙;우재석;우흥명
    • 한국임상수의학회지
    • /
    • 제27권5호
    • /
    • pp.533-539
    • /
    • 2010
  • 최근 줄기세포를 이용한 재생의학분야의 세포치료 연구가 활발히 진행되고 있으나 상대적으로 복잡한 구조를 갖는 신장에서는 난치성 질환인 급성신부전에 대한 줄기세포 치료의 효과는 아직도 논란의 여지가 많다. 이는 연구자마다 다양한 동물모델을 사용하는 것이 한 원인으로 지적되고 있다. 본 연구에서는 줄기세포의 치료효과 분석을 위한 최적의 동물모델 조건을 확립하고자 한다. 쥐를 사용하여 세 종류의 급성신장손상모델을 다음과 같이 다양한 농도와 조건에서 분석하였다: glycerol (대조군, 8 ml/kg, 10 ml/kg), cisplatin (대조군, 5 mg/kg, 10 mg/kg)과 허혈/재관류 (대조군, 35 분 허혈, 45 분 허혈). 줄기세포의 재생능력 평가를 위한 모델의 적합성 정도를 신장손상과 회복의 형태적, 기능적 패턴과 생존률 분석을 통하여 실시하였다. 독성모델인 glycerol과 cisplatin은 각각 10 ml/kg과 7.5 mg/kg 농도에서, 그리고 허혈모델은 45 분 모델에서 대조군 및 다른 비교모델에 비해 장기간의 관찰 기간 동안 신기능의 유의적 차이를 보였다. 또한 45 분 허혈 모델에서 50%의 사망률을 보인 것을 제외하고는 모든 군에서 관찰기간 동안 100% 생존율을 보였다. 조직소견에서 허혈과 glycerol 모델에서는 2일째, cisplatin 모델에서는 5일째 각각 유의적인 조직변화가 관찰되었다. 따라서, 관찰기간 동안 급격한 생존율 감소 없이 안전하고, 조직학적 평가와 신기능에서 대조군과 유의적인 차이를 보이는 cisplatin 7.5 mg/kg, glycerol 10 ml/kg, 35 분 허혈 모델이 치료효과를 평가하기에 적합한 모델로 사료되며, 줄기세포의 세포치료효과 분석에 적합한 급성신장손상 모델로 추천된다.

심실중격결손을 동반하지 않은 대혈관전위증 환자에서 동맥 전환술의 결과 및 위험인자 분석에 관한 연구 (Risk Factors Analysis and Results of the Arterial Switch Operation for Transposition of the Great Arteries with Intact Ventricular Septum)

  • 김용진;오삼세;이정렬;노준량;서경필
    • Journal of Chest Surgery
    • /
    • 제32권2호
    • /
    • pp.108-118
    • /
    • 1999
  • 배경: 동맥전환술의 위험인자와 장기 성적을 알아보고자 후향적 연구를 시행하였다. 대상 및 방법: 1988년 1월부터 1996년 12월까지 심실중격이 온전한 대혈관전위증으로 인해 동맥전환술을 시행 받은 58명의 환자를 대상으로 동맥전환술에 따른 조기 및 만기성적에 대하여 후향적 평가를 시행하였다. 술전 처치로 36례(62.1%)에서 풍선심방절개술을 시행하였으며, 32례(51.7%)에서 PGE1을 사용하였고, 좌우심실의 압력비가 평균 0.53$\pm$0.11이었던 6례(10.3%)의 환아에서는 먼저 폐동맥밴딩을 시행하였다. 결과: 수술당시의 평균연령은 24$\pm$26일(범위 1-137일)이었고 수술당시 평균체중은 3.5$\pm$0.8 kg(범위 1.8~6.1 kg)였다. 전체 조기사망율은 24.1%(14/58)였으며, 최근 3년간의 조기사망율은 8.3%(2/24)였다. 사망과 관련된 위험인자 분석에서는 수술 시행 년도가 유일한 위험인자로 나타났다(p-value < 0.01). 조기 사망한 14례 중 8례는 급성심근부전으로 사망하였으며 주된 원인은 관상동맥부전이었다. 44명의 술후 생존자들을 대상으로 2개월에서 8년까지 평균 36$\pm$27개월 동안 추적관찰을 시행하였으며, 대혈관과 관상동맥의 문합부위, 심실기능, 반월판막의 폐쇄부전, 심박동 이상 등에 중점을 두고 연속적인 비관혈적 검사 및 술후 5개월과 32개월 사이에 모두 21례의 심도자술을 시행하였다. 만기 사망한 경우는 5례(11.4%)였으며 사망원인은 관상동맥의 만기 협착 1례, 흡인 2례, 만성 종격동염 1례, 진행성 대동맥판막폐쇄부전과 심부전 1례 등이었다. 혈류역학적으로 가장 흔한 이상은 폐동맥상부의 협착이었고, 폐동맥협착과 대동맥협착을 보였던 몇몇 경우에 있어서는 점차 협착정도가 진행하는 경우도 관찰되었으나 이로 인한 재수술은 없었다. 9례에서 대동맥판막폐쇄부전 소견을보였으며 7례에서는 그 정도가 가벼웠으나 2례에서는 중정도의 폐쇄부전을 보였고 다소 진행하는 경우도 있었다. 수술전후로 심근허혈의 증거가 없었던 2례에서 관상동맥의 폐쇄가 확인되었다. 나머지 생존자들은 동성박동과 정상적인 좌심기능을 유지한 채 양호한 경과를 보이고 있으며 생명표법에 근거한 8년 생존률은 68.8%였다. 결론: 심실중격이 온전한 대혈관전위증에서 해부학적 교정술은 우선적인 수술방법으로 여겨지나 추후 지속적인 추적관찰이 필요할 것으로 사료된다.

  • PDF

만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사 (Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia)

  • 장중현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권6호
    • /
    • pp.846-855
    • /
    • 1999
  • 연구배경 : 만성 저산소성 폐질환 환자의 폐동맥고혈압은 폐혈류 장애에 따른 악화에 이르는 주요 합병증이다. 폐동맥 고혈압과 이에 수반되는 폐성심의 임상적 진단은 때로 모호하여 폐동맥압의 비관혈적인 심초음파 검사의 중요성이 대두되고 있다. 최근 도플러 심초음파는 기존의 M모드 검사법에 비해 측정치의 정확도, 재생산성과 좋은 창을 얻을 수 있는 상대적인 장점이 있어 폐기종성 환자에서 보다 적용하기 용이한 검사법이다. 본 연구는 만성 저산소성 폐질환의 폐동맥 고혈압 예상 환자에서 도플러 검사법이 갖는 유의한 지표를 확인함에 목적이 있다. 방 법 : 대상환자는 만성 저산소성 폐질환을 보이며 임상소견상 폐동맥 고혈압이 예상되어 심초음파 검사를 시행받은 19명의 환자들을 대상으로 의의있는 폐동맥 고혈압 지표에 대해 조사하였다. 대상 환자들은 와위에서 좌흉골연이나 늑골하에 2.5MHz 진동자를 두고 도플러 및 M모드 심초음파를 시행하였고 특히, 삼첨판 역류시는 도플러 모드로 예측되는 우심실 수축기압(RVSP)이 40mmHg 이상인 군을 그 미만이거나 삼첨판 역류가 없었던 경우와 구분하여 다른 임상지표들에 대하여 비교, 분석하였다. 결 과 : 1) M모드 심초음파의 늑골하 사방관찰에서 RVSP 상승군이 대조군에 비해 수축기말 우심실 직경은 증가하였지만 그외 이완기말 우심실 직경, 수축기 및 이완기말 면적, 우심실 지유벽의 두께, 우심실 출구의 직경과 심실 중벽 두께 등은 두군간 차이가 없었다. 2) 도플러 모드에서 RVSP 상승군의 우심실 출구 수축기 가속기간(AT)은 $82{\pm}9msec$로 대조군 $96{\pm}16msec$에 비해 유의하게 단축되어 있었다. 3) 동맥혈 검사상 RVSP 상승군은 대조군에 비해 산소분압이 감소되어 있었으나 유의한 차이는 없었고 폐기능검사의 노력성 폐활량 및 1초 노력성호기량도 상승군에서 저하되었으나 두군간 유의한 차이는 없었다. 4) AT는 RVSP와 통계학적으로 유의한 역상관관계를 보여주었다. 결 론 : 만성 저산소성 폐질환에서 임상소견상 폐동맥 고혈압이 예상되는 경우 이를 규명하기 위해 심초음파 검사를 하여 컬러도플러로 삼첨판 역류가 확인되면 연속파 도플러로 RVSP를 예측할 수 있으며 이는 간헐파 도플러의 AT의 단축과 관련되어 있음을 확인하였다. 도플러 모드하의 RVSP 및 AT의 측정은 폐동맥 고혈압의 좋은 지표가 될 수 있을 것으로 예상된다.

  • PDF

자연 기흉의 치료에서 8 French 도관삽입의 치료 효과에 대한 장기적 관찰 (The Long-term Follow-up Study of Therapeutic Effects of 8 French Catheter for Spontaneous Pneumothorax)

  • 신종욱;이병훈;안창혁;최재선;유지훈;임성용;강윤정;고형기;김재열;나문준;박인원;손동섭;최병휘;허성호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권5호
    • /
    • pp.1094-1104
    • /
    • 1997
  • 연구배경 : 자연 기흉은 기저 질환이 없는 건강한 사람에서 발생하는 원발성 자연 기흉과, 결핵이나 만성폐쇄성 폐질환에서 발생하는 속발성 자연기흉으로 나뉘어지며, 자연 기흉에 대한 치료는 다양하지만 흔히 흉관 삽입을 우선적으로 고려하고 있다. 흉관삽입법은 특별한 술식과 삽입시 통증, 피하기종, 감염 등의 합병증이 문제되는 바 본 저자들은 흉관에 비해 직경이 훨씬 작은 8 French 도관을 자연 기흉의 치료에 적용했을 때 단기적인 치료 효과가 있음을 이전 연구에서 확인한 바 있다. 본 연구는 의인성 기흉의 치료에 이용되어져 왔던 작은 직경의 도관을 자연 기흉의 치료에 적용하였을 때, 치료 성공후 추적관찰을 통하여 재발율을 조사하여 장기적인 치료적 효과를 살펴보고자 하였다. 방법 : 1990년 1월부터 1996년 1월까지 중앙대학교 부속병원 내과와 흉부외과에서 8 French 도관 또는 흉관 삽입법으로 치료받은 원발성 또는 속발성 자연 기흉 환자 62명을 대상으로 하였으며 이들은 기흉의 크기가 가 25% 이상, 기흉의 크기에 관계없이 호흡곤란이나 흉통이 발생하였을 때, 기흉의 크기가 증가할 때, 다시 재발한 자연 기흉 환자를 대상으로 하였다. 긴장성 기흉, 혈흉, 화학적 흉막유착술이나 흉강경하 기포절제술을 한 경우는 대상에서 제외되었다. 임상특성(성별, 연령별, 과거 기흉의 유무, 기흉의 크기, 기저 질환의 유무)을 조사하고 합병증, 유치기간, 의무기록이나 개인적 접촉을 통하여 관찰 후 재발율을 비교 분석 하였다. 결과 : 8 French 삽입군과 흉관 삽입군의 추적 관찰기간의 중앙값은 각각 28개월, 22개월로 양군간에 유의한 차이를 보이고 있지 않았다. 8 French 도관 삽입군과 흉관 삽입군의 대상환자들의 임상적 특성-성별, 연령별, 기저 질환의 유무, 기흉의 크기의 분포에는 유의한 차이가 없었다. 원발성 및 속발성을 포함한 자연 기흉을 대상으로 비교한 결과, 도관 또는 흉관의 유치기간은 8 French 도관 삽입군이 $6.2{\pm}3.8$일로 흉관삽입군의 $9.1{\pm}7.5$일에 비해 유의하게 짧았다(p=0.047). 원발성 자연 기흉을 대상으로 두군을 비교하여, 8 French 도관 삽입군의 치료와 관련된 합병증은 6.25%로 흉관삽입군의 23.8%에 비해 더 적은 경향을 관찰할 수 있었다(0.041 ; one-tailed, p=0.053, two-tailed). 8 French 도관 삽입군과 흉관 삽입군에서 재발율에 있어서는 유의한 차이를 나타내지 않았다. 결론 : 이상의 결과로 원발성 또는 속발성 자연 기흉에 대한 치료로 지금까지의 흉관삽입법에 대하여 더 작은 직경의 도관을 삽입하여 치료에 의한 합병증의 빈도를 줄이면서, 치료기간을 줄이고 장기적인 재발을 예방할 수 있을 것으로 기대되며, 더 많은 환자를 대상으로하여 전향적인 연구가 앞으로 필요할 것으로 사료된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF