• 제목/요약/키워드: non-testing methods

검색결과 490건 처리시간 0.028초

Assessment of DVC measurement uncertainty on GFRPs with various fiber architectures

  • Bartulovic, Ante;Tomicevic, Zvonimir;Bubalo, Ante;Hild, Francois
    • Coupled systems mechanics
    • /
    • 제11권1호
    • /
    • pp.15-32
    • /
    • 2022
  • The comprehensive understanding of the fiber reinforced polymer behavior requires the use of advanced non-destructive testing methods due to its heterogeneous microstructure and anisotropic mechanical proprieties. In addition, the material response under load is strongly associated with manufacturing defects (e.g., voids, inclusions, fiber misalignment, debonds, improper cure and delamination). Such imperfections and microstructures induce various damage mechanisms arising at different scales before macrocracks are formed. The origin of damage phenomena can only be fully understood with the access to underlying microstructural features. This makes X-ray Computed Tomography an appropriate imaging tool to capture changes in the bulk of fibrous materials. Moreover, Digital Volume Correlation (DVC) can be used to measure kinematic fields induced by various loading histories. The correlation technique relies on image contrast induced by microstructures. Fibrous composites can be reinforced by different fiber architectures that may lead to poor natural contrast. Hence, a priori analyses need to be performed to assess the corresponding DVC measurement uncertainties. This study aimed to evaluate measurement resolutions of global and regularized DVC for glass fiber reinforced polymers with different fiber architectures. The measurement uncertainties were evaluated with respect to element size and regularization lengths. Even though FE-based DVC could not reach the recommended displacement uncertainty with low spatial resolution, regularized DVC enabled for the use of fine meshes when applying appropriate regularization.

노인의 악력과 보행 가변성 간의 연관성: 예비연구 (Association between Hand Grip Strength and Gait Variability in Elderly: Pilot Study)

  • 이도연;이윤곤;신성훈
    • PNF and Movement
    • /
    • 제20권1호
    • /
    • pp.125-134
    • /
    • 2022
  • Purpose: The aim of this study was to establish an association between grip strength and gait variability in the elderly. Methods: The participants in this experiment (n = 20) were aged 65 or older. Power grip and lateral pinch forces were obtained in grip strength tests, and spatiotemporal gait parameters were collected from IMU sensors during 6 min actual walking to test the gait of participants. The collected gait parameters were converted to coefficient of variation (CV) values. To confirm the association between grip strength and gait variability, a partial correlation analysis was conducted in which height, weight, and gait speed were input as controlling variables. Results: Grip power showed a significant negative correlation with the stride length CV (r = -0.52), and the lateral pinch force showed a significant negative correlation with the stance CV (r = -0.65) and swing CV (r = -0.63). Conclusion: This study reveals that gait variability decreases as grip strength increases, although height, weight, and gait speed were controlled. Thus, grip strength testing, a simple aging evaluation method, can help identify unstable gait in older adults at risk of falling, and grip strength can be utilized as a non-invasive measurement method for frailty management and prevention.

Healthcare Systems and COVID-19 Mortality in Selected OECD Countries: A Panel Quantile Regression Analysis

  • Jalil Safaei;Andisheh Saliminezhad
    • Journal of Preventive Medicine and Public Health
    • /
    • 제56권6호
    • /
    • pp.515-522
    • /
    • 2023
  • Objectives: The pandemic caused by coronavirus disease 2019 (COVID-19) has exerted an unprecedented impact on the health of populations worldwide. However, the adverse health consequences of the pandemic in terms of infection and mortality rates have varied across countries. In this study, we investigate whether COVID-19 mortality rates across a group of developed nations are associated with characteristics of their healthcare systems, beyond the differential policy responses in those countries. Methods: To achieve the study objective, we distinguished healthcare systems based on the extent of healthcare decommodification. Using available daily data from 2020, 2021, and 2022, we applied quantile regression with non-additive fixed effects to estimate mortality rates across quantiles. Our analysis began prior to vaccine development (in 2020) and continued after the vaccines were introduced (throughout 2021 and part of 2022). Results: The findings indicate that higher testing rates, coupled with more stringent containment and public health measures, had a significant negative impact on the death rate in both pre-vaccination and post-vaccination models. The data from the post-vaccination model demonstrate that higher vaccination rates were associated with significant decreases in fatalities. Additionally, our research indicates that countries with healthcare systems characterized by high and medium levels of decommodification experienced lower mortality rates than those with healthcare systems involving low decommodification. Conclusions: The results of this study indicate that stronger public health infrastructure and more inclusive social protections have mitigated the severity of the pandemic's adverse health impacts, more so than emergency containment measures and social restrictions.

Analyzing the Influence of Spatial Sampling Rate on Three-dimensional Temperature-field Reconstruction

  • Shenxiang Feng;Xiaojian Hao;Tong Wei;Xiaodong Huang;Pan Pei;Chenyang Xu
    • Current Optics and Photonics
    • /
    • 제8권3호
    • /
    • pp.246-258
    • /
    • 2024
  • In aerospace and energy engineering, the reconstruction of three-dimensional (3D) temperature distributions is crucial. Traditional methods like algebraic iterative reconstruction and filtered back-projection depend on voxel division for resolution. Our algorithm, blending deep learning with computer graphics rendering, converts 2D projections into light rays for uniform sampling, using a fully connected neural network to depict the 3D temperature field. Although effective in capturing internal details, it demands multiple cameras for varied angle projections, increasing cost and computational needs. We assess the impact of camera number on reconstruction accuracy and efficiency, conducting butane-flame simulations with different camera setups (6 to 18 cameras). The results show improved accuracy with more cameras, with 12 cameras achieving optimal computational efficiency (1.263) and low error rates. Verification experiments with 9, 12, and 15 cameras, using thermocouples, confirm that the 12-camera setup as the best, balancing efficiency and accuracy. This offers a feasible, cost-effective solution for real-world applications like engine testing and environmental monitoring, improving accuracy and resource management in temperature measurement.

화재 피해를 입은 철근콘크리트 슬래브의 잔존 구조성능 평가기법 (Evaluation Techniques for Residual Structural Performance of a Reinforced Concrete slab under Fire Damage)

  • 최광호
    • 한국산학기술학회논문지
    • /
    • 제21권2호
    • /
    • pp.588-594
    • /
    • 2020
  • 이 연구에서는 철근콘크리트 건축물의 슬래브에 대해 화재 후 잔존 구조성능을 상온 시 내구성 진단과는 다르게, 고온특성을 보다 정확히 평가하기 위하여 전기로를 이용 800 ℃까지의 가열실험을 수행하였고 가열 전 후의 잔존 구조성능을 반발경도법과 초음파속도법 등의 비파괴 검사와 아울러 진동실험으로 구한 고유진동수로 처짐계산에 사용되는 강성을 평가하는 기법을 제안하였다. 반발경도를 이용한 압축강도 평가에서는 두꺼운 두께와 물/시멘트비(W/C)가 큰 실험체의 잔존 압축강도가 크게 나타났다. 콘크리트를 투과하는 초음파속도로 상온 대비 고온수열 콘크리트의 균질도를 평가하였으며 W/C와 부재 두께의 차이는 초음파 속도법의 결과에 큰 차이가 없는 것으로 판단되었다. 화재 피해 슬래브의 처짐 증가에 영향을 미치는 강성을 평가하기 위한 기법으로, 진동실험에 의해 고유진동수를 측정하고 이를 강성과의 관계식에 대입하였으며, 이를 슬래브 실험체에 적용해 본 결과 매우 합리적인 평가기법이 될 수 있음을 보여주었다. 또한, 고온 수열 후 부재의 잔존강도를 평가하기 위해 가열중과 가열 후 가력실험을 수행한 결과 800 ℃ 내력은 상온의 부재 내력에 비해 22%의 감소를 나타내었다.

도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구 (The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal)

  • 김희진;김부섭
    • 대한치과기공학회지
    • /
    • 제32권3호
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

편평세포암종 임파절 전이에 대한 인공 신경망 시스템의 진단능 평가 (Artificial Neural Network System in Evaluating Cervical Lymph Node Metastasis of Squamous Cell Carcinoma)

  • 박상욱;허민석;이삼선;최순철;박태원;유동수
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.149-159
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate cervical lymph node metastasis of oral squamous cell carcinoma patients by MRI film and neural network system. Materials and Methods: The oral squamous cell carcinoma patients(21 patients. 59 lymph nodes) who have visited SNU hospital and been taken by MRI. were included in this study. Neck dissection operations were done and all of the cervical lymph nodes were confirmed with biopsy. In MR images. each lymph node were evaluated by using 6 MR imaging criteria(size. roundness. heterogeneity. rim enhancement. central necrosis, grouping) respectively. Positive predictive value. negative predictive value. and accuracy of each MR imaging criteria were calculated. At neural network system. the layers of neural network system consisted of 10 input layer units. 10 hidden layer units and 1 output layer unit. 6 MR imaging criteria previously described and 4 MR imaging criteria (site I-node level II and submandibular area. site II-other node level. shape I-oval. shape II-bean) were included for input layer units. The training files were made of 39 lymph nodes(24 metastatic lymph nodes. 10 non-metastatic lymph nodes) and the testing files were made of other 20 lymph nodes(10 metastatic lymph nodes. 10 non-metastatic lymph nodes). The neural network system was trained with training files and the output level (metastatic index) of testing files were acquired. Diagnosis was decided according to 4 different standard metastatic index-68. 78. 88. 98 respectively and positive predictive values. negative predictive values and accuracy of each standard metastatic index were calculated. Results: In the diagnosis of using single MR imaging criteria. the rim enhancement criteria had highest positive predictive value (0.95) and the size criteria had highest negative predictive value (0.77). In the diagnosis of using single MR imaging criteria. the highest accurate criteria was heterogeneity (accuracy: 0.81) and the lowest one was central necrosis (accuracy: 0.59). In the diagnosis of using neural network systems. the highest accurate standard metastatic index was 78. and that time. the accuracy was 0.90. Neural network system was more accurate than any other single MR imaging criteria in evaluating cervical lymph node metastasis. Conclusion: Neural network system has been shown to be more useful than any other single MR imaging criteria. In future. Neural network system will be powerful aiding tool in evaluating cervical node metastasis.

  • PDF

Diagnostic Evaluation of Non-Interpretable Results Associated with rpoB Gene in Genotype MTBDRplus Ver 2.0

  • Singh, Binit Kumar;Sharma, Rohini;Kodan, Parul;Soneja, Manish;Jorwal, Pankaj;Nischal, Neeraj;Biswas, Ashutosh;Sarin, Sanjay;Ramachandran, Ranjani;Wig, Naveet
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권4호
    • /
    • pp.289-294
    • /
    • 2020
  • Background: Line probe assay (LPA) is standard diagnostic tool to detect multidrug resistant tuberculosis. Non-interpretable (NI) results in LPA (complete missing or light wild-type 3 and 8 bands with no mutation band in rpoB gene region) poses a diagnostic challenge. Methods: Sputum samples obtained between October 2016 and July 2017 at the Intermediate Reference Laboratory, All India Institute of Medical Sciences Hospital, New Delhi, India were screened. Smear-positive and smear-negative culture-positive specimens were subjected to LPA Genotype MTBDRplus Ver 2.0. Smear-negative with culture-negative and culture contamination were excluded. LPA NI samples were subjected to phenotypic drug susceptibility testing (pDST) using MGIT-960 and sequencing. Results: A total of 1,614 sputum specimens were screened and 1,340 were included for the study (smear-positive [n=1,188] and smear-negative culture-positive [n=152]). LPA demonstrated 1,306 (97.5%) valid results with TUB (Mycobacterium tuberculosis) band, 24 (1.8%) NI, three (0.2%) valid results without TUB band, and seven (0.5%) invalid results. Among the NI results, 22 isolates (91.7%) were found to be rifampicin (RIF) resistant and two (8.3%) were RIF sensitive in the pDST. Sequencing revealed that rpoB mutations were noted in all 22 cases with RIF resistance, whereas the remaining two cases had wild-type strains. Of the 22 cases with rpoB mutations, the most frequent mutation was S531W (n=10, 45.5%), followed by S531F (n=6, 27.2%), L530P (n=2, 9.1%), A532V (n=2, 9.1%), and L533P (n=2, 9.1%). Conclusion: The present study showed that the results of the Genotype MTBDRplus assay were NI in a small proportion of isolates. pDST and rpoB sequencing were useful in elucidating the cause and clinical meaning of the NI results.

위상배열초음파를 이용한 손상된 열가소성 플라스틱배관 전기융착부 비파괴검사 (Non-Destructive Testing of Damaged Thermoplastic Pipes Electrofusion Joints Using Phased Array Ultrasonic)

  • 길성희;김병덕;권정락;윤기봉
    • 한국가스학회지
    • /
    • 제17권5호
    • /
    • pp.64-68
    • /
    • 2013
  • 열가소성 플라스틱배관의 전기융착부에 대한 비파괴검사방법은 융착부의 안전성을 확보하고 장기적인 신뢰성을 확보하기 위한 방법이다. 정상적인 방법에 의하여 융착된 접합부에서도 배관의 진원도와 전기융착 소켓과의 진원도 차이 또는 기공 등에 의해 융착부에 결함이 발생할 수 있다. 본 연구에서는 위상배열초음파를 이용하여 손상된 폴리에틸렌 전기융착부의 검사를 수행하였다. 검사 대상인 250mm 직경의 폴리에틸렌 배관 전기융착부는 1994년 12월에 융착되었으며 실제 작동 압력은 2.45kPa이다. 2004년 2월 소켓 이음부 근처에서 가스가 누설되어 수거되었다. 손상된 전기융착부에 대하여 첫 번째로 육안검사를 실시하고 다음에 위상배열초음파를 이용한 비파괴검사를 실시하였다. 그리고 절단 검사를 실시하여 각각의 검사 결과와 비교하였으며 위상배열 초음파를 이용한 검사결과와 절단 검사 결과가 동일함을 확인하였다.

비유기수은 종자소독제개발에 관한 연구 (Studies on the development of seed disinfectant in non-mercurious compounds)

  • 이두형
    • 한국응용곤충학회지
    • /
    • 제18권2호
    • /
    • pp.63-71
    • /
    • 1979
  • 비유기수은 종자소독제의 개발을 목적으로 배도열병균, 벼깨씨무늬병균 및 벼키다리병균에 감염된 증자 4개품종을 공시하고 Blotter 법, 물한천평판법 및 유묘 검정법 등을 통해서 12종의 약제에 대한 약효를 검정하는 동시에 검정방법별 차이를 검토하고 약해발현 여부등을 조사하였으며, 그 결과는 다음과 같다. 벼${\cdot}$도열병, 벼${\cdot}$깨씨무늬병 및 벼${\cdot}$키다리병에 대하여 종합적으로 약효가 좋았던 것은 Sisthane, $P_{242}$ 및 Sodium Omadine이었다. Benlate T 및 Homai는 깨씨무늬병에 대한 약효가 낮았으며, Busan 30 및 Panoctine은 유묘검정에서 키다리병에 대한 약효가 낮았다. 약효검정방법으로서는 도열병에 대해서는 Blotter법이, 깨씨무늬병과 키다리병에 대해서는 물한천평판법이 좋았다. 발아율 및 초기생육에 미치는 약제의 최아전종자소독 결과, 약해의 유발은 없었다.

  • PDF