• Title/Summary/Keyword: non-proper

Search Result 1,361, Processing Time 0.029 seconds

Non Existence of 𝒫ℛ-semi-slant Warped Product Submanifolds in a Para-Kähler Manifold

  • Sharma, Anil
    • Kyungpook Mathematical Journal
    • /
    • v.60 no.1
    • /
    • pp.197-210
    • /
    • 2020
  • In this paper, we prove that there are no non-trivial 𝒫ℛ-semi-slant warped product submanifolds with proper slant coefficients in para-Kähler manifolds ${\bar{M}}$. We also present a numerical example that illustrates the existence of a 𝒫ℛ-warped product submanifold in ${\bar{M}}$.

Modal identifiability of a cable-stayed bridge using proper orthogonal decomposition

  • Li, M.;Ni, Y.Q.
    • Smart Structures and Systems
    • /
    • v.17 no.3
    • /
    • pp.413-429
    • /
    • 2016
  • The recent research on proper orthogonal decomposition (POD) has revealed the linkage between proper orthogonal modes and linear normal modes. This paper presents an investigation into the modal identifiability of an instrumented cable-stayed bridge using an adapted POD technique with a band-pass filtering scheme. The band-pass POD method is applied to the datasets available for this benchmark study, aiming to identify the vibration modes of the bridge and find out the so-called deficient modes which are unidentifiable under normal excitation conditions. It turns out that the second mode of the bridge cannot be stably identified under weak wind conditions and is therefore regarded as a deficient mode. To judge if the deficient mode is due to its low contribution to the structural response under weak wind conditions, modal coordinates are derived for different modes by the band-pass POD technique and an energy participation factor is defined to evaluate the energy participation of each vibration mode under different wind excitation conditions. From the non-blind datasets, it is found that the vibration modes can be reliably identified only when the energy participation factor exceeds a certain threshold value. With the identified threshold value, modal identifiability in use of the blind datasets from the same structure is examined.

Comparison of Dry-Seeding Methods for Improving Rice Seedling Stand on Reclaimed Saline Soil (간석지 벼 입모율 향상을 위한 건답직파 방법 비교)

  • 이인;성기영
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.3
    • /
    • pp.370-375
    • /
    • 1996
  • This study was conducted to find out the feasibility in direct seeded rice cultivation on the reclaimed saline soil. Seedling emergence was tested under the different application rates of rice straw and seeding depth, and also under combined treatments soil moisture regimes and seeding depth on saline soils in a greenhouse. The comparison of seedling stand and yield performance of rice in rotary till after broadcast seeding and in non-plow after broadcast seeding were tested on a field that reclaimed saline soil. Seedling emergence ratio in application of rice straw(4 and 6 tons /ha) was higher than that in non-application of rice straw. Seedling emergence and plant height were remarkably increased with the shallow seeding depth in the application of rice straw(4 tons /ha). The seedling emergence under proper soil moisture condition(25%) was higher than that under excess soil moisture condition(35%). Under proper soil moisture condition, the plant height was increased with the shallowed seeding depth. The number of seedling stand per m$^2$ in non-plow after broadcast seeding was larger than that in rotary till after broadcast seeding. Panicle number per m$^2$ in non-plow after broadcast seeding was much larger than that in rotary till after broadcast seeding and the yield showed the same trends as panicle number.

  • PDF

FATIGUE DESIGN OF BUTT-WELDED TUBULAR JOINTS

  • Kim, D. S.;S. Nho;F. Kopp
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.127-132
    • /
    • 2002
  • Recent deepwater offshore structures in Gulf of Mexico utilize butt welded tubular joints. Application of welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical because the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimating the fatigue behavior of these tubular members in the design stage is generally conducted by using S-N curves specified in the codes and standards. Applying the stress concentration factor of the welded structure to S-N approach often results in very conservative assessment because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fracture mechanics and fitness for service (FFS) technology have been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves to be used and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. An attempt was made to develop set of S-N curves based on fracture mechanics approach by considering non-uniform stress distribution and a threshold stress intensity factor. Series of S-N curves generated from this approach were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02"). Similar comparison with API X′ was made for tubular joint.. These initial crack depths are larger than the limits of inspection by current Non-destructive examination (NDE) means, such as Automatic Ultrasonic Inspection (AUT). Thus a safe approach can be taken by specifying acceptance criteria that are close to limits of sizing capability of the selected NDE method. The comparison illustrates conservatism built into the S-N design curve.

  • PDF

Non-squamous Cell Tumor of the Larynx (후두의 비편평상피암)

  • Choi Eun-Chang;Kim Kwang-Moon;Hong Won-Pyo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.6 no.2
    • /
    • pp.101-107
    • /
    • 1990
  • Most common laryngeal cancer is squamous cell carcinoma, but various kinds of non-squamous cell tumor also occurs in the larynx. It is quite different from epidermoid carcinoma in the aspect of invasive behavior, metastatic route and treatment modality. Its proper diagnosis is somewhat difficult due to its rarity. This paper presents clinical feature of eight non-squamous cell tumor of the larynx experienced during the past 15 years.

  • PDF

Field Inspection of Phase-Array Ultrasonic for PolyEthylene Electrofusion Joints

  • Kil, Seong-Hee;Jo, Young-Do;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.22-25
    • /
    • 2012
  • Welding and/or fusion in polyethylene(PE) system made on site is focused on the control of the welding or fusion process to follow proper procedure. The process control is important, but it is not sufficient for the long term reliability of a pipe system. To achieve the rate of failure close to zero, Non Destructive Testing(NDT) is necessary in addition to joining process control. For electrofusion joints several non-destructive testing methods are available. The ultrasonic phased array technique is possible to detect various defects including wire deviations and regions with lack of fusion. In this studies, testing was carried to detect the defect after electrofusion joining of polyethylene piping is utilized by the ultrasonic phased array technique. From testing data, ultrasonic phased array technique is recommended as a reliable non-destructive testing method.

Non-regressor Based Adaptive Tracking Control of an Underwater Vehicle-mounted Manipulator (수중 선체에 장착된 로봇팔 궤적의 비귀환형 적응제어)

  • 여준구
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.7-12
    • /
    • 2000
  • This paper presents a non-regressor based adaptive control scheme for the trajectory tracking of underwater vehicle-mounted manipulator systems(UVMS). The adaptive control system includes a class of unmodeled effects is applied to the trajectory control of an UVMS. The only information required to implement this scheme ios the upper bound and lowe bound of the system parameter matrices the upper bound of unmodeled effects the number of joints the position and attitude of the vehicle and trajectory commands. The adaptive control law estimates control gains defined by the combinations of the bounded constants of system parameter matrices and of a filtered error equation. To evaluate the performance of the non-regressor based adaptive controller computer simulation was performed with a two-link planar robot model mounted on an underwater vehicle. The hydrodynamic effects acting on the manipulator are included. It is assumed that the vehicle's motion is slow and can be predicted with a proper compensator.

  • PDF

UNDERSTANDING NON-NEGATIVE MATRIX FACTORIZATION IN THE FRAMEWORK OF BREGMAN DIVERGENCE

  • KIM, KYUNGSUP
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.25 no.3
    • /
    • pp.107-116
    • /
    • 2021
  • We introduce optimization algorithms using Bregman Divergence for solving non-negative matrix factorization (NMF) problems. Bregman divergence is known a generalization of some divergences such as Frobenius norm and KL divergence and etc. Some algorithms can be applicable to not only NMF with Frobenius norm but also NMF with more general Bregman divergence. Matrix Factorization is a popular non-convex optimization problem, for which alternating minimization schemes are mostly used. We develop the Bregman proximal gradient method applicable for all NMF formulated in any Bregman divergences. In the derivation of NMF algorithm for Bregman divergence, we need to use majorization/minimization(MM) for a proper auxiliary function. We present algorithmic aspects of NMF for Bregman divergence by using MM of auxiliary function.

The Vestibuloplasty Using Non-eugenol-based Non-zinc Oxide Oral Dressing Material

  • Ku, Jeong-Kui;Leem, Dae Ho
    • Journal of Korean Dental Science
    • /
    • v.14 no.1
    • /
    • pp.46-50
    • /
    • 2021
  • This study describes a patient with insufficient vestibular depth who was operated with a vestibuloplasty using a non-eugenol-based non-zinc oxide oral dressing material. Partial thickness flap was elevated on recipient. After stabilization of apical positioned flap, the dressing material was applied on the recipient site with additional fixation by suture. The patient presented minimal discomfort such as in pain, food impaction and management of oral hygiene. Adequate vestibular depth without relapse was observed until 4 weeks after surgery. The vestibuloplasty with the oral dressing material may be an option for obtaining proper vestibular depth without complications.

A Historical Study of Non-standard Weight and Measuring Units (역대(歷代) 약물(藥物) 비표준(非標準) 계량단위(計量單位)의 고찰(考察))

  • Yun, Sung-Joong;Moon, Young-Choon;Kim, Ji-Hoon;Jung, Gi-Eun;Kim, Yun-Kyung
    • Herbal Formula Science
    • /
    • v.24 no.4
    • /
    • pp.335-351
    • /
    • 2016
  • Objective : This study was done to clarify ambiguous non-standard weight and measuring units in medical classics. Methods : Using medical classics and research dissertations, we studied the basic definitions of weight and measuring units and the types of non-standard weight and measuring units. We compared non-standard weight and measuring units in the reference literatures, to determine the dose of herbs in the prescriptions. Results : There are three types of units in non-standard weight and measuring units. These are 'Quantity measuring unit', 'Resembrance measuring unit', and 'Eye measuring unit'. And we found historical efforts and progresses for proper ways to convert non-standard weight and measuring units to standard weight and measuring units. Conclusions : This research will be the basic data for the standardization of prescriptions. Additional study was still required for precise weighing and measuring in Korean medicine and pharmacy.