• 제목/요약/키워드: non-orthogonal

검색결과 444건 처리시간 0.028초

금속재료 표면층의 급격한 응력구배에 대한 X-Ray회절 특성값과 측정된 변형률의 해석방법 (Analysis Method of X-Ray Diffraction Characteristic Values and Measured Strain for Steep Stress Gradient of Metal Material Surface Layer)

  • 한창석;이찬우
    • 한국재료학회지
    • /
    • 제33권2호
    • /
    • pp.54-62
    • /
    • 2023
  • The most comprehensive and particularly reliable method for non-destructively measuring the residual stress of the surface layer of metals is the sin2ψ method. When X-rays were used the relationship of εφψ-sin2ψ measured on the surface layer of the processing metal did not show linearity when the sin2ψ method was used. In this case, since the effective penetration depth changes according to the changing direction of the incident X-ray, σφ becomes a sin2ψ function. Since σφ cannot be used as a constant, the relationship in εφψ-sin2ψ cannot be linear. Therefore, in this paper, the orthogonal function method according to Warren's diffraction theory and the basic profile of normal distribution were synthesized, and the X-ray diffraction profile was calculated and reviewed when there was a linear strain (stress) gradient on the surface. When there is a strain gradient, the X-ray diffraction profile becomes asymmetric, and as a result, the peak position, the position of half-maximum, and the centroid position show different values. The difference between the peak position and the centroid position appeared more clearly as the strain (stress) gradient became larger, and the basic profile width was smaller. The weighted average strain enables stress analysis when there is a strain (stress) gradient, based on the strain value corresponding to the centroid position of the diffracted X-rays. At the 1/5 Imax max height of X-ray diffraction, the position where the diffracted X-ray is divided into two by drawing a straight line parallel to the background, corresponds approximately to the centroid position.

XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구 (Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT)

  • 정한성;김영주;오오성;이세호;전호상;이승욱
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.143-152
    • /
    • 2015
  • 본 연구에서는 두 개의 치료빔 가속기가 사용되는 구조에서 종양 위치 추적을 하는 두 쌍의 kV 영상시스템의 기하학적 설계 및 종양 위치 추적 정확도 분석을 목표로 하고 있다. 특히, 병변의 위치추적을 위한 수식 및 알고리즘을 수립하였고, 두 쌍의 kV 영상 시스템이 비직교 위치에 놓일 때 검출기 해상도가 종양 위치 추적 오차에 미치는 영향에 대해서 모의실험으로 분석하여 보았다. 병변의 위치추적을 위한 수식 및 알고리즘을 수립하기 위해서 각 엑스선원, 검출기 등의 절대좌표는 동차방정식을 이용하여 설정하였으며, 삼차원 상의 두 직선의 방정식을 통하여 병변의 절대위치를 찾아내도록 하였다. XCAT 프로그램을 이용한 모의실험을 통해서 영상 검출기의 해상도가 미치는 영향을 두 개의 kV 영상시스템의 각도에 따라서 분석하여보았다. XCAT 소프트웨어를 이용하여서 팬텀에 병변 추적을 위한 금속 기점 마커를 삽입하였고, CT projection 프로그램을 이용하여 각 kV 영상시스템의 각도별, 검출기의 해상도별 영상을 획득할 수 있다. 모의실험 결과, 두 kV영상시스템의 각도가 $90^{\circ}$에서 $50^{\circ}$까지는 검출기 해상도가 1.5 mm/pixel보다 고해상도 일 때 약 1 mm 이하의 위치 오차를 보였다. 하지만, 검출기의 해상도가 1.5 mm/pixel 이상으로 나빠질수록 오차가 약 1 mm 이상으로 나타날 뿐만 아니라 각도에 따른 오차의 변동이 컸다. 검출기의 해상도가 개선될 수록 그 각도별 오차의 변동이 줄어들고, $90^{\circ}$에서 가장 적은 오차가 발생 하는 것을 볼 수 있었다. 충분한 해상도의 검출기가 사용된다면 듀얼헤드 겐트리 시스템과 같이 공간적으로 제한된 방사선 치료기기에 두 개의 kV 영상시스템을 예각으로 설치하여도 된다는 결론을 도출할 수 있었다. 본 연구에서 개발한 모의실험 방법론은 병변의 위치, 검출기의 특성, kV 영상 시스템의 기하학적 배치에 따른 종양추적 위치 추적시스템의 정확도를 분석하는 도구로서 유용하게 사용될 수 있을 것이다.

고에너지 선형가속기에 의한 입체방사선수술의 선량특성 (Dose Characteristics of Stereotactic Radiosurgery in High Energy Linear Accelerator Proton Beam)

  • 최태진;김옥배
    • Radiation Oncology Journal
    • /
    • 제10권2호
    • /
    • pp.137-145
    • /
    • 1992
  • 전산화단층촬영에 근거를 둔 3차원선량계산은 소형의 뇌종양에 대한 방사선수술에 있어서 가장 기본이 된다. 본 연구의 방사선수술 프로그램은 전산화단층촬영을 통해 표적 위치, 크기와 모양을 3차원공간에서 결정하고 최적조사면적을 구할 수 있었다. 방사선수술의 선량은 선형가속기의 6메가볼트 고에너지 광자선을 이중 비공면의 회전조사를 가상두부에 실시하여 계산된 3차원적 선량분포와 필름선량계의 실측선량을 비교한 바 거의 일치됨을 확인하였다. 본 연구의 방사선수술에서 $80\%$에서 $50\%$까지 선량곡선의 기울기는 전회전각이 1120도 일때 10 mm 조사면적에서 약 $16.7\%$/mm 였고 30 mm 에서 는 $13.0\%$/mm를 보였다. 또한 표적 주위의 선량분포는 표적내 최대선량값이 $90\%$ 에서 $50\%$ 까지 선량분포의 최대폭은 직경 10 mm조사면에서 2.3 mm를 나타내었으며, $90\%$에서 $20\%$까지의 거리는 5.6 mm를 나타내었으며, 30 mm직경의 조사면에서는 각각 3.5 mm와 9.8 mm를 보였다. 이러한 선량분포의 급격한 기울기는 방사선수술시 표적주위의 치명부위의 손상을 최소화하기 위한 선량최적화 작업에 지침이 될 것으로 생각되며, 또한 방사선수술방법의 차이에 따라 비교자료가 될 수 있을 것으로 생각된다.

  • PDF

대칭형 2자유도 수평 공진기를 이용한 마이크로 자이로스코프의 동특성 해석 및 평가 (Dynamic Analysis and Evaluation of a Microgyroscope using Symmetric 2DOF Planar Resonator)

  • 홍윤식;이종현;김수현
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2001
  • 기존의 진동형 마이크고 자이로스코프는 고감도화를 이루기 위해 구동 모드와 검출 모드를 동조시킬 필요성이 있었다. 본 연구에서는 고유하게 조율된 두 개의 공진 모드를 갖는 광진기를 이용하여 자가동조 특성을 갖는 마이크로 자이로스프로의 응용에 대한 타당성을 검증한다. 진동하는 두 축에 대해 대칭의 구조를 가지는 2자유도 수평 공진기가 모드 동조의 필요성을 최소화하는 자이로스코프로의 응용을 위해 소개된다. 자이로스코프의 적용을 고려한 동역학적 모델이 도출되고 이는 제조된 마이크로 자이로스코프와 실험을 통해 비교 검증 된다. 마이크로 자이로스코프의 구조체는 산화막 위의 폴리실리콘 박막으로 구성되어 간단한 2마스크 공정으로 제조 가능하다. 자가동조 특성을 갖는 진동형 자이로스코프로서의 타당성이 해석 결과와 실험을 통해 검증되었다. 8개의 실험 시편에 대해서 구동 및 검출 모드의 공진 주파수를 측정했을 때, 구동 및 검출 모드의 공진 주파수에 대한 표준편차가 각각 1232Hz와 1214HZ인데 반해 비동조 주파수의 평균값은 91.75Hz를 나타내 우수한 자가동조 특성을 보였다. 샘플 중 최소 비동조 주파수는 68Hz였고 이때의 감도는 $0.034mV/sec/^{\circ}$로 측정되어 공정의 불균일성이 개선되면 녹은 감도를 구현학 수 있는 자이로스코프로서의 타당성을 확인할 수 있었다.

  • PDF

비정질구조의 ZTO 박막에서 커패시턴스와 이동도 분석 (Analysis of Capacitance and Mobility of ZTO with Amorphous Structure)

  • 오데레사
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.14-18
    • /
    • 2019
  • 반도체의 전도성은 주로 케리어에 의해서 결정된다. 전도성이 높아지려면 케리어의 수가 많고 에너지 내의 트랩 준위를 만들어서 케리어들이 낮은 에너지로도 금지대역을 넘어설수 있도록 하는 도핑기법을 주로 사용한다. 케리어들은 결정질 결합구조를 갖으며, 계면불일치에 의하여 전도성이 떨어지는 경향도 있지만 대체적으로 고농도 도핑은 이동도를 높이는 대표적인 방법에 속한다. 하지만 비정질 결합구조에서도 전도성이 높아지는 현상이 나타나며, 본 연구에서는 트래핑현상과는 다른 터널링 현상에 의한 공간전하제한 전류가 흐르면서 전도성이 향상되고 이동도가 높아지는 현상에 대하여 관찰하였다. 비정질구조에서는 케리어수가 낮고 저항이 높아지며, 커패시턴스의 on/off 특성이 향상되면서 이동도가 높아지는 것을 확인하였다. ZTO 박막은 150도에서 열처리한 경우 커패시턴스의 on/off 특성이 향상되었으며, 충전과 방전하는 실험에서는, 충전과 방전되는 형상에 있어서 시간차이가 있었으며, n형과 p형의 구분이 없었으며, 공핍층과 같은 비정질 결합구조를 보여주었다. 비정질 결합구조는 전위장벽으로 볼 수 있으며, 전위장벽은 공간전하제한전류가 흐르게 되는 원천이기도 하며, 터널링현상에 의한 전도현상이 나타나는 원인이 된다. 따라서 비정질구조에서 이동도가 증가하는 현상이 나타났으며, 케리어가 희박함에도 불구하고 전도성이 증가하는 것을 확인하였다.

Age-related Changes in Multi-finger Synergy during Constant Force Production with and without Additional Mechanical Constraint

  • Park, Yang Sun;Kwon, Hyun Joon;Koh, Kyung;Shim, Jae Kun
    • 한국운동역학회지
    • /
    • 제26권2호
    • /
    • pp.175-181
    • /
    • 2016
  • Objective: The aim of this study was to investigate age-related changes of multi-finger synergy during a constant force production task with and without an additional mechanical constraint. Method: Fourteen elderly subjects (age: $78.50{\pm}4.63yrs$, height: $157.29{\pm}8.97cm$, weight: $65.13{\pm}6.93kg$) and 14 young subjects (age: $21.13{\pm}1.35yrs$, height: $171.57{\pm}8.43cm$, weight: $70.29{\pm}16.77kg$) participated in this study. The subjects were asked to place their index and middle fingers on two force transducers fixed on a small non-moving teeterboard and produce 10 N by pressing the sensors while watching force feedback on a computer screen under the no additional constraint condition (NAC). The subjects also performed the same task with an additional mechanical constraint (AC) where the subjects were asked to balance a teeterboard that could be rotated by finger forces. An uncontrolled manifold approach was used to calculate within-trial and between-trial multi-finger synergy indices, variance in uncontrolled subspace ($V_{UCM}$), and variance in subspace orthogonal to UCM subspace ($V_{ORT}$). Two-way repeated measured ANOVA was performed with the within-factor of task condition (with and without an additional constraint) and the between factor of groups (elderly and young). Results: The elderly group showed significantly increased within-trial $V_{ORT}$ in AC compared with NAC (p < .05) while the young group showed no significant difference between AC and NAC. There was no significant group difference for within-trial $V_{UCM}$. Between-trial $V_{ORT}$ remained unchanged between groups and conditions. However, between-trial $V_{UCM}$ for the elderly group significantly decreased in AC as compared to NAC, along with no significant difference for the young group. For multi-finger synergy, there was no significant group difference of within-trial synergy. However, between-trial synergy for the elderly group significantly decreased in AC as compared to NAC (p < .05). Conclusion: Our results indicate that aging decreased consistency (i.e., ability to perform the task on a moment-to-moment basis) with an additional mechanical constraint. In addition, aging was associated with decreased multi-finger synergy on a trial-to-trial basis.

MIMO 시스템을 위한 다채널 FFT 프로세서의 설계 및 구현 (Design and Implementation of Multi-channel FFT Processor for MIMO Systems)

  • 정용철;조재찬;정윤호
    • 한국항행학회논문지
    • /
    • 제21권6호
    • /
    • pp.659-665
    • /
    • 2017
  • 본 논문에서는 MIMO(multiple input multiple output) 시스템을 위한 저복잡도 FFT(fast Fourier transform) 프로세서의 설계 및 구현 결과를 제시하였다. 무선랜을 이용한 다양한 멀티미디어 서비스 등을 이용하기 위해 높은 채널 용량과 Gbps급 전송이 가능한 시스템에 대한 요구와 함께 IEEE 802.11ac 규격이 채택되었다. MIMO-OFDM (orthogonal frequency duplex multiplexing) 기술을 사용하는 IEEE 802.11ac 규격의 무선랜 시스템은 최대 8개의 안테나 구성 및 20-160 MHz 대역폭을 지원해야한다. 따라서, 제안된 FFT 프로세서는 8채널 64, 128, 256, 512 point 가변길이를 지원한다. 또한, 비단순 승산기의 수를 감소시키기 위해서 MRMDC(mixed-radix multipath delay commutator) 구조를 적용하였고, 이로 인해 제안된 FFT 프로세서는 기존 FFT 프로세서에 비해 현저히 낮은 복잡도로 구현 가능하다. 구현 결과, 제안된 FFT processor는 기존 방식인 radix-2 SDF 구조 대비 gate count가 50 % 감소 가능하였고, 8 채널 MR-2/2/2/4/2/4/2 MDC 구조와 8채널 MR-2/2/2/8/8 MDC 구조 대비 logic gate 수를 각각 18 %와 17 % 감소 가능함이 확인되었다.

4 병렬 동기 구조를 이용한 MB-OFDM UWB 수신기 설계 및 평가 (A MB-OFDM UWB Receive Design and Evaluation Using 4. Parallel Synchronization Architecture)

  • 신철호;최상성;이한호;백정기
    • 한국전자파학회논문지
    • /
    • 제16권11호
    • /
    • pp.1075-1085
    • /
    • 2005
  • 본 논문은 IEEE802.15.3a Alt-PHY로 표준화중인 MB-OFDM WB(Multi-Band Orthogonal Frequency Division Multiplexing Ultra Wide Band) 시스템 수신기 설계 방안을 제시하고 링크 마진(link margin) 설계를 위해 4 병렬 구조에 의한 구현 손실을 정량적으로 분석하는 것이다. 먼저 MB-OFDM UWB 시스템의 전송 방식을 설명하고, 동기 구조를 완전한 디지털 방식으로 설계하기 위해 반송 주파수 옵셋(carrier frequency offset)과 샘플링 클락옵셋(sampling clock offset)이 MB-OFDM UWB 시스템에 미치는 영향을 분석하였다. 그리고 이러한 반송 주파수 옵셋과 샘플링 클락 옵셋을 추정하고 보상하기 위한 알고리즘과 VLSI 구현을 위하여 MB-OFDM UWB 시스템의 패킷 전송 구조를 이용한 4 병렬 동기 구조를 제시하였다. 본 논문에서 제시한 시스템 동기를 위한 수신 구조와 단순화된 4 병렬 구조에 의한 구현 손실 값은 UWB-OFDM 시스템 규격에서 제시한 최대 허용 가능한 반송 주파수 옵셋 및 샘플링 클락 옵셋에서 최대 3.08 dB로 시뮬레이션을 통해 분석되었다.

C형 및 H형 철근콘크리트 구조벽체의 2축 상호작용과 등하중법 (Biaxial Interaction and Load Contour Method for Reinforced Concrete C- and H-shaped Structural Walls)

  • 남혜성;엄태성
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.189-200
    • /
    • 2017
  • C형 및 H형 단면의 구조벽체는 고층 건물에서 횡력저항시스템으로 널리 이용된다. 이러한 이형벽체는 축력과 함께 x축 및 y축에 대한 2방향 휨모멘트를 동시에 받으므로, 안전한 벽체설계를 위해서는 휨-압축 상호작용을 정확히 고려해야 한다. 이 연구에서는, 대칭단면을 갖는 기둥을 위하여 개발된 기존 등하중법을 수정하여, 2방향으로 재하된 C형 및 H형 벽체를 위한 근사설계방법을 제안하였다. 다양한 단면형상을 갖는 이형벽체에 대하여 2방향 모멘트강도를 계산할 수 있는 단면해석 프로그램을 개발하고, 실험결과와 비교를 통하여 프로그램의 정확성을 검증하였다. 또한 개발한 프로그램을 사용한 변수연구를 통하여, C형 및 H형 이형벽체 단면에 대한 2축 상호작용 특성을 분석하였다. 분석 결과, C형 및 H형 이형벽체의 2축 상호작용은 모멘트 방향과 압축력 크기에 의하여 크게 영향을 받는 것으로 나타났다. 이러한 변수연구를 통하여 일정한 압축력에서 2축 모멘트강도의 상관관계를 나타내는 정규화된 컨투어 설계식을 제안하였다. 또한 실무에서 쉽게 활용할 수 있도록, 제안된 컨투어 설계식을 사용한 이형벽체 설계절차와 설계예제를 제시하였다.

차세대 이동통신 시스템에 PAPR 감소기법을 적용한 다항식 사전왜곡 기법에 관한 연구 (A Study on Polynomial Pre-Distortion Technique Using PAPR Reduction Method in the Next Generation Mobile Communication System)

  • 김완태;박기식;조성준
    • 한국항행학회논문지
    • /
    • 제14권5호
    • /
    • pp.684-690
    • /
    • 2010
  • 차세대 이동통신 시스템은 다양한 서비스의 융합과 멀티모드를 지원하기 위한 구조로 연구되고 있다. 또한 다양한 서비스를 제공받기 위한 사용자의 요구는 점차 증가되고 있으며, 서비스 지원을 위한 대용량 데이터 전송을 위한 많은 통신방식들이 출현하고 있다. 그 중 대표적인 시스템으로 OFDM(Orthogonal Frequency Division Multiplexing) 방식을 이용하는 WiBro(Wireless Broadband), WLAN(Wireless Local Area Network) 등이 있다. 하지만 차세대 이동통신 시스템에서는 하나의 단말로 OFDM 방식을 이용한 통신방식 이외 CDMA(Code Division Multiple Access), WCDMA(Wideband CDMA) 방식을 동시에 지원 받고자한다. 통합된 시스템은 SoC(System on Chip) 기술 적용으로 빠른 발전을 이루고 있지만, 무선통신 시스템에서 필수적으로 요구되는 요소 중 전력 증폭기의 비선형 특성으로 인한 신호의 왜곡을 유발시켜 인접채널 간섭을 성화 시키고 시스템의 효율을 떨어뜨리는 문제를 해결해야 한다. 전력증폭기의 문제점을 해결하기 위해 많은 선형화 기법들이 제시되었으며, 다항식 사전왜곡 기법은 증폭기로 입력되는 신호가 증폭기의 역 특성을 갖도록 하는 기법으로 다항식을 통하여 증폭기를 모델링하기 때문에 수렴 속도가 빠르고 다른 기법들과 비교하여 우수한 성능을 보인다. 본 논문에서는 차세대 이동통신 서비스를 위한 모뎀 구조를 제시하고 OFDM 방식 사용에 있어 발생 되는 PAPR(Peak-to-Average Power Ratio) 감소 기법을 적용한 후 다항식 사전왜곡 기법을 적용하여 차세대 이동통신 시스템을 분석하였다.