• 제목/요약/키워드: non-linear static

검색결과 294건 처리시간 0.027초

A TRUST REGION METHOD FOR SOLVING THE DECENTRALIZED STATIC OUTPUT FEEDBACK DESIGN PROBLEM

  • MOSTAFA EL-SAYED M.E.
    • Journal of applied mathematics & informatics
    • /
    • 제18권1_2호
    • /
    • pp.1-23
    • /
    • 2005
  • The decentralized static output feedback design problem is considered. A constrained trust region method is developed that solves this optimal control problem when a complete set of state variables is not available. The considered problem is interpreted as a non-linear (non-convex) constrained matrix optimization problem. Then, a decentralized constrained trust region method is developed for this problem class exploiting the diagonal structure of the problem and using inexact computations. Finally, numerical results are given for the proposed method.

Seismic performance evaluation for steel MRF: non linear dynamic and static analyses

  • Calderoni, B.;Rinaldi, Z.
    • Steel and Composite Structures
    • /
    • 제2권2호
    • /
    • pp.113-128
    • /
    • 2002
  • The performance of steel MRF with rigid connections, proportioned by adopting different capacity design criteria, is evaluated in order to highlight the effectiveness of static non-linear procedure in predicting the structural seismic behavior. In the framework of the performance-based design, some considerations are made on the basis of the results obtained by both dynamic time histories and push-over analyses, particularly with reference to the damage level and the structure ability to withstand a strong earthquake.

고고도 장기체공무인기 주익 Spar 비선형 구조 해석 (Non-linear Structural Analysis of Main Wing Spar of High Altitude Long Endurance UAV)

  • 박상욱;신정우;이무형;김태욱
    • 한국항공운항학회지
    • /
    • 제23권1호
    • /
    • pp.24-29
    • /
    • 2015
  • In order to increase endurance flight efficiency of long endurance electric powered UAV, main wing of UAV should have high aspect ratio and low structural weight. Since a spar which consists of thin and slender structure for weight reduction can cause catastrophic failure during the flight, it is important to develop verification method of structural integrity of the spar with the light weight design. In this paper, process of structural analysis using non-linear finite element method was introduced for the verification of structural integrity of the spar. The static strength test of the spar was conducted to identify structural characteristic under the static load. Then, the experimental result of the spar was compared to the analytical result from the non-linear finite element analysis. It was found that the developed process of structural analysis could predict well the non-linear structural behavior of the spar under ultimate load.

선형행렬부등식을 이용한 정적출력궤환 제어기 설계 (Design of a Static Output Feedback Stabilization Controller by Solving a Rank-constrained LMI Problem)

  • 김석주;권순만;김춘경;문영현
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.747-752
    • /
    • 2004
  • This paper presents an iterative linear matrix inequality (LMI) approach to the design of a static output feedback (SOF) stabilization controller. A linear penalty function is incorporated into the objective function for the non-convex rank constraint so that minimizing the penalized objective function subject to LMIs amounts to a convex optimization problem. Hence, the overall procedure results in solving a series of semidefinite programs (SDPs). With an increasing sequence of the penalty parameter, the solution of the penalized optimization problem moves towards the feasible region of the original non-convex problem. The proposed algorithm is, therefore, convergent. Extensive numerical experiments are Deformed to illustrate the proposed algorithm.

정적 및 동적 하중을 받는 외팔보 거동에 관한 선형 및 CR 정식화 비선형 예측의 비교 (Linear Analysis and Non-linear Analysis with Co-Rotational Formulation for a Cantilevered Beam under Static/Dynamic Tip Loads)

  • 고정우;빈영빈;은원종;신상준
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.467-475
    • /
    • 2015
  • 본 논문에서는 구조물에 작용하는 하중의 크기와 진동수에 따른 거동의 비선형성을 확인하고 정확한 예측을 위한 방법을 모색하기 위하여 외팔보의 정적 및 동적해석의 수행에서 선형, 비선형 해석의 결과를 비교하는 연구를 진행하였다. 우선 보의 자유단에 수직방향의 정적 및 동적 하중을 가한 상황을 예측하였다. 선형 해석방법으로 고전 외팔보 이론을 적용하였고, co-rotational dynamic 유한요소해석 기법을 개발하여 비선형 해석방법으로 사용하였다. 먼저 정적해석에서 외력의 크기가 달라질 때 선형 및 비선형 해석 예측이 어떠한 차이를 보이는지 비교하였다. 그리고 동적해석을 통해 가진 진동수의 변화에 따른 보 끝단의 무차원화된 변위의 양상을 연구하였고, 공진진동수 근방에서의 상당한 변위가 발생함을 보였다. 마지막으로 주파수 지연현상을 조사하기 위해 특정 진동수에서의 시간 경과에 따른 보의 변위를 확인하였다.

선형 시스템 수동화를 위한 병렬 앞먹임 보상기 설계방법 연구 (Design Method of a Parallel Feedforward Compensator for Passivation of Linear Systems)

  • 손영익
    • 제어로봇시스템학회논문지
    • /
    • 제10권7호
    • /
    • pp.590-596
    • /
    • 2004
  • A passivity-based dynamic output feedback controller design is considered for a finite collection of non-square linear systems. Design of a single controller for a set of plants i.e. simultaneous stabilization is an important issue in the area of robust control design. We first determine a squaring gain matrix and an additional dynamics that is connected to the systems in a feedforward way, then a static passivating control law is designed. Consequently, the actual feedback controller will be the static control law combined with the feedforward dynamics. A necessary and sufficient condition for the existence of the parallel feedforward compensator is given by the static output feedback formulation. In contrast to the previous result [1], a technical condition for constructing the parallel feedforward compensator is removed by proposing a new type of the parallel compensator.

입력 차수 보상기를 이용한 비정방 선형 시스템의 출력 궤환 수동화 (Output Feedback Passivation of Non-square Linear Systems Using an Input-Dimensional Compensator)

  • 손영익
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권1호
    • /
    • pp.10-15
    • /
    • 2004
  • We present a state-space approach to make non-square linear systems strictly passive by using an input-dimensional parallel feedforward compensator. A necessary and sufficient condition for the existence of the parallel feedforward compensator is given by the static output feedback formulation, which enables to utilize linear matrix inequality. By modifying the structure of the compensator the additional technical assumption in the previous result [1] is removed. The effectiveness of the proposed method is illustrated by some numerical examples which can be stabilized by the proportional-derivative (PD) and proportional-derivative-integral (PID) control laws. The proposed control scheme can successfully replace the measurements of derivative terms in the control laws.

쌍입력 기술함수를 갖는 비선형 보상기를 이용한 유연한 빔의 제어 (The Control of Flexible Beam using Nonlinear Compensator with Dual-Input Describing Function)

  • 권세현;이형기;최부귀
    • 제어로봇시스템학회논문지
    • /
    • 제4권5호
    • /
    • pp.644-650
    • /
    • 1998
  • In this paper , a state space model for flexible beam is presented using the assumed-modes approach. The state space equation is derived for a flexible beam in which one end is connected to a motor and is driven by a torque equation and the other end is free. Many of the transfer function proposed thus far use the torque to the flexible beam as the input and the tip deflection of the flexible beam as the output. The Technique for the analysis and synthesis of the dual-input describing function(DIDF) is introduced here and the construction of a non-linear compensator, based on this technique, is proposed. This non-linear compensator, properly connected in the direct path of a closed-loop linear or non-linear control system. The above non-linear network is used to compensate linear and non-linear systems for instability, limit cycles, low speed of response and static accuracy. The effectiveness of the proposed scheme is demonstrated through computer simulation and experimental results.

  • PDF

A Solid State Controller for Self-Excited Induction Generator for Voltage Regulation, Harmonic Compensation and Load Balancing

  • Singh Bhim;Murthy S. S.;Gupta Sushma
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.109-119
    • /
    • 2005
  • This paper deals with the performance analysis of static compensator (STATCOM) based voltage regulator for self­excited induction generators (SEIGs) supplying balanced/unbalanced and linear/ non-linear loads. In practice, most of the loads are linear. But the presence of non-linear loads in some applications injects harmonics into the generating system. Because an SEIG is a weak isolated system, these harmonics have a great effect on its performance. Additionally, SEIG's offer poor voltage regulation and require an adjustable reactive power source to maintain a constant terminal voltage under a varying load. A three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC- VSI) known as STATCOM is used for harmonic elimination. It also provides the required reactive power an SEIG needs to maintain a constant terminal voltage under varying loads. A dynamic model of an SEIG-STATCOM system with the ability to simulate varying loads has been developed using a stationary d-q axes reference frame. This enables us to predict the behavior of the system under transient conditions. The simulated results show that by using a STATCOM based voltage regulator the SEIG terminal voltage can be maintained constant and free from harmonics under linear/non linear and balanced/unbalanced loads.

Structural identification and seismic performance of brick chimneys, Tokoname, Japan

  • Aoki, T.;Sabia, D.
    • Structural Engineering and Mechanics
    • /
    • 제21권5호
    • /
    • pp.553-570
    • /
    • 2005
  • Dynamic and static analyses of existing structures are very important to obtain reliable information relating to actual structural properties. For this purpose a series of material test, dynamic test and static collapse test of the existing two brick chimneys, in Tokoname, are carried out. From the material tests, Young's modulus and compressive strength of the brick used for these chimneys are estimated to be 3200 MPa and 7.5 MPa, respectively. The results of static collapse test of the existing two brick chimneys are discussed in this paper and composed with the results from FEA (Finite Element analysis). From the results of dynamic tests, the fundamental frequencies of Howa and Iwata brick chimneys are estimated to be about 2.69 Hz and 2.93 Hz, respectively. Their natural modes are identified by ARMAV (Autoregressive Moving Average Vectors) model. On the basis of the static and dynamic experimental tests, a numerical model has been prepared. According to the European code (Eurocode n. 8: "Design of structures for earthquake resistance") non-linear static (Pushover) analysis of the two chimneys is carried out and they seem to be vulnerable to earthquakes with 0.25 to 0.35 g.