• Title/Summary/Keyword: non-invasive sample

Search Result 40, Processing Time 0.024 seconds

Invasive and non-invasive methods for estimating the optical properties of tissue at laser wavelengths (레이저 파장에서의 생체 침습적 및 비침습적 광학계수 측정 방법)

  • Yoon, Gil-Won
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.147-150
    • /
    • 1994
  • To predict light propagation in biological tissues irradiated by laser, the optical properties such as absorption and scattering coefficients are required. There have been various techniques for measuring these coefficients. One method requires tissue samples, often a slab of thin tissue, is invasive. On the other hand, non-invasive method usually measures back-scattered light from a subject with no physical intervent ions. Advantages and disvantages of using different methods are investigated. A careful attention should be made in order to select the best method for a given experimental condition since, even either for invasive or non-invasive method, accuracy is subject to governing models and sample preparations.

  • PDF

A Non-invasive Real-time Respiratory Organ Motion Tracking System for Image Guided Radio-Therapy (IGRT를 위한 비침습적인 호흡에 의한 장기 움직임 실시간 추적시스템)

  • Kim, Yoon-Jong;Yoon, Uei-Joong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.676-683
    • /
    • 2007
  • A non-invasive respiratory gated radiotherapy system like those based on external anatomic motion gives better comfortableness to patients than invasive system on treatment. However, higher correlation between the external and internal anatomic motion is required to increase the effectiveness of non-invasive respiratory gated radiotherapy. Both of invasive and non-invasive methods need to track the internal anatomy with the higher precision and rapid response. Especially, the non-invasive method has more difficulty to track the target position successively because of using only image processing. So we developed the system to track the motion for a non-invasive respiratory gated system to accurately find the dynamic position of internal structures such as the diaphragm and tumor. The respiratory organ motion tracking apparatus consists of an image capture board, a fluoroscopy system and a processing computer. After the image board grabs the motion of internal anatomy through the fluoroscopy system, the computer acquires the organ motion tracking data by image processing without any additional physical markers. The patients breathe freely without any forced breath control and coaching, when this experiment was performed. The developed pattern-recognition software could extract the target motion signal in real-time from the acquired fluoroscopic images. The range of mean deviations between the real and acquired target positions was measured for some sample structures in an anatomical model phantom. The mean and max deviation between the real and acquired positions were less than 1mm and 2mm respectively with the standardized movement using a moving stage and an anatomical model phantom. Under the real human body, the mean and maximum distance of the peak to trough was measured 23.5mm and 55.1mm respectively for 13 patients' diaphragm motion. The acquired respiration profile showed that human expiration period was longer than the inspiration period. The above results could be applied to respiratory-gated radiotherapy.

Compensation of Variation from Long-Term Spectral Measurement for Non-invasive Blood Glucose in Mouse by Near-Infrared Spectroscopy (근적외분광분석법을 이용한 생쥐꼬리에서의 비침습 혈당 정량시 장기간 측정에 따른 변이 요인의 보정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.48 no.3
    • /
    • pp.177-181
    • /
    • 2004
  • Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period with the collection of near-infrared (NIR) spectra. Spectral variations from long-term measurement (10 weeks) from dramatic and nonlinear changes in the optical properties of the live tissue sample were compensated by chemometrics techniques such as principle component analysis (PCA) and partial least squares (PLS) regression. The effect from mouse body temperature changes on NIR spectral data was also considered. This study showed that the compensation of variations from long-term measurement and temperature changes improved calibration accuracy of non-invasive blood glucose measurement.

Optimization of a fiber optic probe for non-invasive blood glucose monitoring

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Lee, Hyun-Chul;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.407.3-408
    • /
    • 2002
  • A portable near infrared (NIR) system which was newly integrated by our lab has been used to develop a non-invasive blood glucose monitoring. The portable NIR system includes a tungsten halogen lamp, a photo diode array type-InGaAs detector, and specialized reflectance fiber optic probes. The shape of probes is composed of two parts. one for illumination into sample and the other for receiving the radiation from sample. Three kinds of probes with different distance between illumination and receiving part. such as 0.03. 0.1. and 0.5mm, were investigated for optimization. (omitted)

  • PDF

Testing microsatellite loci and preliminary genetic study for Eurasian otter in South Korea

  • Jo, Yeong-Seok;Won, Chang-Man;Jung, Jongwoo
    • Journal of Species Research
    • /
    • v.1 no.2
    • /
    • pp.240-248
    • /
    • 2012
  • We used a non-invasive technique with microsatellite primers to investigate genetic variation among Eurasian otters Lutra lutra in eastern South Korea. We collected twenty two otter spraints in January and six in August 2008. We used spraints from five dead otters from five different river systems for the present genetic analysis. We extracted DNA from 20 spraints from the January sample. Ten microsatellite primers (Lut435, Lut453, Lut457, Lut604, Lut615, Lut701, Lut715, Lut717, Lut733, and Lut832) for Eurasian otters were tested, and four loci were successfully amplified for further analyses. The results of genotyping the otter population with microsatellite loci lead to the identification of 9 individuals from the Ungokcheon Stream. The Ungokcheon population also showed a genetic structure represented by the Hardy-Weinberg equilibrium.

Minimally Invasive Lumbar Spinal Decompression : A Comparative Study Between Bilateral Laminotomy and Unilateral Laminotomy for Bilateral Decompression

  • Kim, Seok-Won;Ju, Chang-Il;Kim, Chong-Gue;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.195-199
    • /
    • 2007
  • Objective : Bilateral laminotomy and unilateral laminotomy for bilateral decompression are becoming the minimally invasive procedures for lumbar spinal stenosis (LSS). With the aim of less invasiveness and better preservation of spinal stability. these techniques have been developed. But there are no large randomized studies to show the surgical results between these two techniques. The objective of this study was to examine the safety and efficacy of these two minimally invasive techniques. Methods : A total of 80 patients were included in this study (Group I : bilateral laminotomy, Group II : Unilateral laminotomy for bilateral decompression). Perioperative parameters and complications were analyzed. Symptoms and scores such as visual analog scale (VAS) scores, Oswestry Disability Index (ODI) scores, and SF-36 scores of prospectively accrued patients were assessed preoperatively and at 1 month and 12 months after surgery. Paired-t test, two-sample student-t tests, and non parametric tests were used to determine cross-sectional differences between two groups. Results : No major complications such as spinal instability or deaths occurred during follow-up periods. VAS, ODI scores and SF-36 body pain and physical function scores showed statistically significant improvements in both groups (p<0.001). The significant widening of the spinal canal diameter was also noted in both groups. But, in Group II. there were minor postoperative complications such as dural tear (2 cases 5.0%), fracture of ipsilateral inferior facet (1 case 2.5%), and 5 cases of transient leg symptoms of contralateral side. Conclusion : Both bilateral laminotomy and unilateral laminotomy for bilateral decompression allow achievement of adequate and long-lasting operative results in patients with LSS. But postoperative complications are more frequent in Group II (unilateral laminotomy and bilateral decompression). These results indicate that bilateral laminotomy is the preferred minimally invasive technique to treat symptomatic LSS.

Application of infrared thermography to the pulp vitality test

  • Terada, R.;Hosoya, N.;lino, F.;Komoriyama, M.;Hirano, S.;Arai, T.
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.581-581
    • /
    • 2003
  • The purpose of this study was to search non-invasive and reproductive pulp test. Temperature of the crown surface was measured using the infrared thermography, and the pulp test was investigated with difference of crown temperature of the vital and the non-vital tooth in vitro and in vivo. Twenty extracted human maxillary central incisors were used in this study. Two sample teeth after access cavity preparation were arranged setting with one pair. Then, the each tooth wes estimated as the vital and the non-vital tooth.(중략)

  • PDF

Problems in the Pathologic Diagnosis of Suspected Lung Cancer

  • Soo Han Kim;Mi-Hyun Kim;Min Ki Lee;Jung Seop Eom
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.3
    • /
    • pp.176-182
    • /
    • 2023
  • Since the introduction of low-dose computed tomography (CT) screening for patients at high risk of lung cancer, the detection rate of suspicious lung cancer has increased. In addition, there have been many advances in therapeutics targeting oncogenic drivers in non-small cell lung cancer. Therefore, accurate pathological diagnosis of lung cancer, including molecular diagnosis, is increasingly important. This review examines the problems in the pathological diagnosis of suspected lung cancer. For successful pathological diagnosis of lung cancer, clinicians should determine the appropriate modality of the diagnostic procedure, considering individual patient characteristics, CT findings, and the possibility of complications. Furthermore, clinicians should make efforts to obtain a sufficient amount of tissue sample using non- or less-invasive procedures for pathological diagnosis and biomarker analysis.

Spectral Analysis for Non-Invasive Total Hemoglobin Measurement in the Region from 400 to 2500nm (총헤모글로빈 농도를 비침습적으로 측정하기 위한 400-2500nm 대역의 흡수 스펙트럼 분석)

  • Jeon, Kye-Jin;Kim, Yoen-Joo;Kim, Su-Jin;Kim, Hong-Sig;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.273-278
    • /
    • 2001
  • Absorption spectra of blood components have been measured for the purpose of predicting the total hemoglobin concentration. We obtained absorption spectra of major blood components from the visible to near-infrared of $400{\sim}2500nm$ region. In the near-infrared, water is the main absorbing constituent. The amount of water in the sample cell varies depending on the volume of solute concentration(water displacement). We acquired water-compensated spectra by considering the variation of water volume depending on the variation of analyze concentration. Those spectra show inherent absorption peaks of analyzes and linearity with respect to concentration. We selected wavelengths for non-invasive measurement of hemoglobin concentration considering the scattering effect of tissue and the interference of other blood components.

  • PDF

Ecological Studies of Wild boars(Sus scrofa) in Yeongwol Hanbando Wetland Inferred through DNA Analysis of Non-invasive Samples (비침습 샘플 DNA 분석으로 유추한 영월 한반도습지 내 멧돼지(Sus scrofa)의 생태 연구)

  • Kim, Minkyung;Lee, Sang-im;Park, Hyomin;Lee, Sangdon
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.3
    • /
    • pp.230-238
    • /
    • 2020
  • This study inferred the ecology of habitat use of the wild boars (Sus scrofa) in Yeongwol Hanbando wetland through DNA analysis using non-invasive samples of hairs. From November 2018 to May 2019, hair samples were collected from rubbing trees and hairtraps within the Hanbando wetland (2.772 ㎢). We extracted DNA from the hair samples and conducted PCR to verify the species and identify sex of the individuals. In addition we analysed 6 microsatellite markers to identify individuals and genetic relationship among the pairs of individuals. A total of 16 boar hairs were sampled, which turned out to be from 10 individual (7 females and 3 males) boars. We found that 9 pairs, out of 45 possible pairs, were most likely to be relatives. The result from kinship data and the location of the sampled hairs suggest that wild boars in this area live as family groups that consist of a mother and her offspring, which is consistent with known habits of wild boars. It is needed to include more samples and microsatellite markers for better precise estimation of kinship among the boar individuals.