• 제목/요약/키워드: non-invasive measuring

검색결과 86건 처리시간 0.037초

동추침(東樞鍼)의 비침습적 노궁혈 자극이 심박변이도에 미치는 영향: 예비연구 (The Effect of Non-Invasive Stimulus at Nogung(PC8) by Dong Chu Chim on HRV: A Pilot Study)

  • 윤순모;박수진;이봉효;이상남
    • Korean Journal of Acupuncture
    • /
    • 제30권2호
    • /
    • pp.104-113
    • /
    • 2013
  • Objectives : The purpose of this study is to analyze an effect of medical Qigong therapy using Dong Chu Chim (DCC) which was invented by "Dongchu Han Medicine Institute", by measuring HRV. We compared effects of DCC with non-treatment, filiform acupuncture and filiform acupuncture with natural abdominal breathing. Methods : 1. The authors stimulated Nogung (PC8) of 26 normal adults by using DCC or filiform acupuncture in turn. 2. The natural abdominal breathing has been carried comfortably with consciousness in the lower abdomen. 3. HRV was measured for 5 minutes, three times (pre-treatment, during-treatment and post-treatment). Results and Conclusions : From this study, it seems that the stimulus of DCC, filiform acupuncture, filiform acupuncture with natural abdominal breathing can all affect the autonomic nervous system and control the balance of that. But there were not significant differences between these stimulus groups and the non-treatment group. Therefore, we suggest additional studies about the effect of DCC in the future.

Non-equibiaxial residual stress evaluation methodology using simulated indentation behavior and machine learning

  • Seongin Moon;Minjae Choi;Seokmin Hong;Sung-Woo Kim;Minho Yoon
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1347-1356
    • /
    • 2024
  • Measuring the residual stress in the components in nuclear power plants is crucial to their safety evaluation. The instrumented indentation technique is a minimally invasive approach that can be conveniently used to determine the residual stress in structural materials in service. Because the indentation behavior of a structure with residual stresses is closely related to the elastic-plastic behavior of the indented material, an accurate understanding of the elastic-plastic behavior of the material is essential for evaluation of the residual stresses in the structures. However, due to the analytical problems associated with solving the elastic-plastic behavior, empirical equations with limited applicability have been used. In the present study, the impact of the non-equibiaxial residual stress state on indentation behavior was investigated using finite element analysis. In addition, a new nonequibiaxial residual-stress prediction methodology is proposed using a convolutional neural network, and the performance was validated. A more accurate residual-stress measurement will be possible by applying the proposed residual-stress prediction methodology in the future.

Computer-Aided Detection with Automated Breast Ultrasonography for Suspicious Lesions Detected on Breast MRI

  • Kim, Sanghee;Kang, Bong Joo;Kim, Sung Hun;Lee, Jeongmin;Park, Ga Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.46-54
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the diagnostic performance of a computer-aided detection (CAD) system used with automated breast ultrasonography (ABUS) for suspicious lesions detected on breast MRI, and CAD-false lesions. Materials and Methods: We included a total of 40 patients diagnosed with breast cancer who underwent ABUS (ACUSON S2000) to evaluate multiple suspicious lesions found on MRI. We used CAD ($QVCAD^{TM}$) in all the ABUS examinations. We evaluated the diagnostic accuracy of CAD and analyzed the characteristics of CAD-detected lesions and the factors underlying false-positive and false-negative cases. We also analyzed false-positive lesions with CAD on ABUS. Results: Of a total of 122 suspicious lesions detected on MRI in 40 patients, we excluded 51 daughter nodules near the main breast cancer within the same quadrant and included 71 lesions. We also analyzed 23 false-positive lesions using CAD with ABUS. The sensitivity, specificity, positive predictive value, and negative predictive value of CAD (for 94 lesions) with ABUS were 75.5%, 44.4%, 59.7%, and 62.5%, respectively. CAD facilitated the detection of 81.4% (35/43) of the invasive ductal cancer and 84.9% (28/33) of the invasive ductal cancer that showed a mass (excluding non-mass). CAD also revealed 90.3% (28/31) of the invasive ductal cancers measuring larger than 1 cm (excluding non-mass and those less than 1 cm). The mean sizes of the true-positive versus false-negative mass lesions were $2.08{\pm}0.85cm$ versus $1.6{\pm}1.28cm$ (P < 0.05). False-positive lesions included sclerosing adenosis and usual ductal hyperplasia. In a total of 23 false cases of CAD, the most common (18/23) cause was marginal or subareolar shadowing, followed by three simple cysts, a hematoma, and a skin wart. Conclusion: CAD with ABUS showed promising sensitivity for the detection of invasive ductal cancer showing masses larger than 1 cm on MRI.

폐동맥관을 부착하고 있는 심장수술 환자에 대한 비침습적 체온측정 방법의 정확도, 정밀도 및 발열감별 타당도 (Accuracy, Precision, and Validity of Fever Detection using Non-invasive Temperature Measurement in Adult Coronary Care Unit Patients with Pulmonary Catheters)

  • 주가을;송경애
    • 대한간호학회지
    • /
    • 제42권3호
    • /
    • pp.424-433
    • /
    • 2012
  • Purpose: To investigate the accuracy, precision and validity of fever detection of tympanic membrane (TM), temporal artery (TA) and axillary temperature (AT) compared with pulmonary artery temperature (PA). Methods: Repeated-measures design was conducted for one year on 83 adult cardiac care unit patients with pulmonary artery catheters after open heart surgery. Sequential temperature measurements were taken three times at 20-minute intervals. Accuracy, precision, repeatability, and validity of fever detection were analyzed. Results: Mean pulmonary artery temperature was $37.04^{\circ}C$ (SD $0.70^{\circ}C$). The mean (SD) offsets from PA, with the mean reflecting accuracy and SD reflecting precision, were $-1.31^{\circ}C$ ($0.75^{\circ}C$) for TA, $-0.20^{\circ}C$ ($0.24^{\circ}C$) for TM, and $-0.97^{\circ}C$ ($0.64^{\circ}C$) for AT. Percentage of pairs with differences within ${\pm}0.5^{\circ}C$ was 9.6% for TA, 19.7% for AT, and 91.6% for TM. Repeated measurements with all three methods had mean SD values within $0.04^{\circ}C$. Sensitivity, specificity, and positive and negative predictive values of tympanic measurements were 0.76, 1.0, and 1.0, and 0.90, respectively. Conclusion: Results show that TM best reflects PA, and is most consistent, accurate, and precise. AT tends to underestimate PA, and TA is least accurate and precise. Therefore tympanic membrane measurement is a reliable alternative to other non-invasive methods of measuring temperatures.

휴대용 요역동학 검사 시 근전도 신호를 이용한 복압측정 방법 (A Non-invasive Measurement of Abdominal Pressure on Ambulatory Urodynamics Study Using Surface Electromyography)

  • 김거식;송철규;서정환
    • 전자공학회논문지SC
    • /
    • 제45권6호
    • /
    • pp.132-140
    • /
    • 2008
  • 복압 측정을 위한 기존의 카데터 방법은 배뇨압에 영향을 줄 수 있는 많은 오차를 유발할 수 있으며 환자에게 불편함을 야기한다. 이러한 문제점을 해결하기 위해, 본 연구에서는 표면 근전도를 이용하여 비침습적으로 복압을 측정할 수 있는 새로운 방법을 개발하였다. 연구 결과, 기존 직장 카테터를 이용하여 측정된 복압과 복압측정 알고리즘을 이용하여 추정된 복압 간의 상관계수는 $0.79{\pm}0.06$이었으며, 두 신호간의 오차는 $0.10{\pm}0.07$이었다. 본 연구에서 개발된 복압추정 알고리즘을 이용하면 휴대용 요역동학 검사 시 편리하게 간접적으로 복압을 측정할 수 있을 것으로 생각된다.

Confocal Scanning Laser Microscope (CSLM)을 이용한 신규 미백 효과 측정 연구 (New Measurement of Whitening Effects by Using Confocal Scanning Laser Microscope (CSLM))

  • 김명기;조석철;남개원
    • 대한화장품학회지
    • /
    • 제41권3호
    • /
    • pp.279-285
    • /
    • 2015
  • 여성의 얼굴에 과색소침착이 발생하는 것은 불안감, 특히 미적인 요소에 있어서 많은 고민을 유발한다. 피부의 흑화는 자외선(UV)에 대하여 이를 방어하기 위한 기작으로 멜라닌의 양과 밀접한 관계가 있다. 이러한 피부의 구성성분을 관찰하기 위해, confocal scanning laser microscope (CSLM)은 피부에 직접 현미경 검사를 실시하여 어떠한 조직의 변화 없이 피부를 실시간으로 관찰할 수 있는 비침습적 이미지 장치이다. 본 연구에서는 자외선 조사를 통해 유도된 하박 내측 피부의 과색소침착을 유도하여, 다른 피부색을 평가하는 측정기기와 상관성을 분석하여, CSLM을 이용한 새로운 미백 평가방법을 제시하였다. CSLM을 활용한 미백 효능 평가법은 소비자가 보다 이해하기 쉽도록 미백 제품을 평가하는데 유용할 것으로 생각된다.

측정부 온도 부하에 따른 광용적맥파 파형 요동 특성 분석 (Analysis for the Fluctuation of the Photoplethysmographic Waveform derived by Temperature Stress of Measuring Position)

  • 이충근;신항식
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.304-309
    • /
    • 2015
  • Applicable range of Photoplethysmography (PPG) becomes wider as a non-invasive physiological measurement technique. However, PPG waveform is easy to be distorted by ambient light or vascular variation from temperature changes. Especially, irregular variation of PPG waveform caused by ambient temperature not only severely distorts the PPG, but also leads miss interpretation in clinical applications. Therefore, the investigation of between temperature and PPG waveform is quite important in using PPG. The purpose of this research is to quantify the PPG waveform characteristic and to investigate the waveform variation following the temperature change on measuring site. To quantify the fluctuation of PPG waveform, we use two techniques; detrended fluctuation analysis (DFA) and AC/DC analysis of PPG. We record PPG under temperature stress, which applied by medical use heat pack ($40^{\circ}C$) and ice pack ($0^{\circ}C$). Ten participants were applied to the experiment, and the result was evaluated to approve the temperature effect with statistical method, Wilcoxon signed rank test. The result shows that the AC component (p<0.05) and perfusion index DFS scale exponent (p<0.01) of PPG have the significance to temperature stress except for a DC component of PPG.

전립선 진단을 위한 수압 측정 방식의 새로운 요 유량 계측기법 (New uroflowmetry technique measuring hydraulic pressure for prostate diagnostics)

  • 김경아;최성수;차은종
    • 센서학회지
    • /
    • 제16권3호
    • /
    • pp.179-186
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostate hypertrophy (BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary flow rate. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiment, variance of the pressure signal was more than 50 % smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

한국 여성의 피부 부위 및 연령에 따른 피부 측정 인자와 생물 인자 연구 (A Study of Skin Biophysical Parameters and Biomarkers related to the Anatomical Site and Age in Korean Women)

  • 조석철;남개원
    • 대한화장품학회지
    • /
    • 제41권4호
    • /
    • pp.413-420
    • /
    • 2015
  • 피부는 신체에서 가장 크고 육중한 기관 중 하나로 인간의 생리 및 병리 과정에 참여한다. 피부는 자기 유지 및 치유, 기계적 및 화학적 손상 방어, 자외선 과 외부 병원성 미생물로부터의 방어, 비타민 D 합성 그리고 사회 심리적 기능을 한다고 알려져 있다. 이 연구의 목적은 한국 여성의 부위와 연령에 따라 피부 생물학 인자와 연관된 생물리학 인자의 변화를 평가하는 데 있다. 20 ~ 49세의 약 70명의 건강한 성인 여성이 이 실험에 참여하였다. 측정부위는 하박 내측과 뺨으로 진행하였다. 인체 피부의 생물리학 인자를 측정하기 위하여 여러 가지 비침습적인 방법으로 진행하였다. 피부의 생물학 인자를 분석하기 위하여 코티졸, 파이브로넥틴, 케라틴-1, 10, 11, 인보루크린, 케라틴 6를 인체의 얼굴과 하박내측으로 비교하였다. 또한 비침습적 방법으로 피부 생물리학 인자는 피부 부위와 연령에 따른 차이를 측정하였다. 측정 부위에 따른 결과, 각질층 수분량, 경피수분손실량과 피부색(L과 a값)은 유의적인 차이가 나타났다. 연령에 따른 결과, 오직 피부색에서만 연령에 따른 차이가 유의적으로 나타났다. 코티졸, 케라틴-6, 파이브로넥틴, 케라틴-1, 10, 11 은 연령과 부위간 유의적 차이가 없지만 인볼루크린은 30 ~ 39세 연령대에서 다른 연령대보다 유의적으로 가장 높았다. 이러한 결과는 개인의 피부 환경에 대한 상세한 피부 상태 변화로 설명할 수 있을 것이다.

비침습적 맥파 측정을 위한 압력센서 패키징에 관한 연구 (Pressure Sensor Packaging for Non-invasive Pulse Wave Measurement)

  • 김은근;남기창;허현;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1978.1_1979.1
    • /
    • 2009
  • In this paper, we have proposed and demonstrated a tonometry sensor array for measuring arterial pulse pressure. A sensor module consists of 7 piezoresistive pressure sensor array. Wire-bonded connection was provided between silicon chip and lead frame. PDMS(poly-dimethylsiloxane) was coated on the sensor array to protect fragile sensor while faithfully transmitting the pressure of radial artery to the sensor. Tonometric pulse pressure can be measured by this packaged sensor array that provides the pressure value versus the output voltage.

  • PDF