Browse > Article

A Non-invasive Measurement of Abdominal Pressure on Ambulatory Urodynamics Study Using Surface Electromyography  

Kim, Keo-Sik (Chonbuk Natl. Univ.)
Song, Chul-Gyu (Chonbuk Natl. Univ.)
Seo, Jeong-Hwan (Chonbuk Natl. Univ. Medical School)
Publication Information
Abstract
Conventional rectal catheters which are used for the measurement of abdominal pressure can cause erroneous result affecting detrusor pressure, and the catheter itself is not comfortable to the patients. To reduce these problems, we invented a new method for measuring abdominal pressure in non invasive manner using surface electromyography (EMG) signals of the rectus abdominis muscle. Our results showed that the correlation coefficient and root mean square error (RMSE) between the measured abdominal pressures by the conventional rectal catheters and the estimated values by our proposed algorithm were $0.79{\pm}0.06$ and $0.10{\pm}0.07$, respectively. These findings suggest that the surface EMG of rectus abdominis muscle might be used indirectly for more convenient measurement of abdominal pressure on ambulatory urodynamic study.
Keywords
Ambulatory urodynamics monitoring; Electromyography; Abdominal pressure; Regression modeling;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 E. Katsavrias. E. Primetis, N.Karandreas, 'A new electromyographic technique and normal motor unit action potential values', Clin. Neurophysiol., Vol. 116, pp. 2528-2532, 2005   DOI   ScienceOn
2 W. Schafer, P. Abrams, L. Liao, A. Mattiasson, F. Pesce, A. Spangberg, A. M. Sterling, N. R. Zinner and P. Van Kerrebroeck, 'Good urodynamic practices: Uroflowmetry, filling cystometry and pressure-flow studies', Neurourol. Urodyn., Vol. 21, pp. 261-274, 2002   DOI   ScienceOn
3 P. C. Ridings, G. L. Bloomfield, C. R. Blocher, 'Cardiopulmonary effects of raised intra- abdominal pressure before and after intravascular volume expansion', J. Trauma, Vol. 39, pp. 1071-1075, 1995   DOI
4 G. Amarenco, S. S. Ismael, D. Lagauche, P. Raibaut, P. Rene-Corail, N. Wolff, P. Thoumie and F. Haab, 'Couch anal reflex: Strict relationship between intravesical pressure and pelvic floor muscle electromyography activity during cough', Urol., Vol. 173, pp. 149-152, 2005   DOI   ScienceOn
5 C. Nordander, J. Willner, G. A. Hansson, B. Larsson, J. Unge, L. Granquist, S. Skerfving, 'Influence of the subcutaneous fat layer, as measured by ultrasound, skinfold calipers and BMI, on the EMG amplitude', Eur. J. Appl. Physiol., Vol. 89, pp. 514-519, 2003   DOI
6 J. Finsterer, 'EMG-interference pattern analysis', J. Electromyogr. Kinesiol., Vol. 11, pp. 231-246, 2001   DOI   ScienceOn
7 A. MacDonald, P. J.Paterson, J. N. Baxter, I. G. Finlay, 'Relationship between intra-abdominal pressure and intra-rectal pressure in the proctometrogram', Br. J. Surg., Vol. 80, pp. 1070-1071, 1993   DOI   ScienceOn
8 J. H. Seo, K. M. Kim, M. H. Ko, S. H. Park, N. G. Kim, 'Motor unit action potentials of the rectus abdominis muscle according to changes of abdominal pressure', J. Korean Acad. Rehab. Med., Vol. 29, pp. 457-461, 2005
9 P. Neumann and V. Gill, 'Pelvic floor and abdominal muscle interaction: EMG activity and intra-abdominal pressure', Int. Urogynecol. J., Vol. 13, pp. 125-132, 2002   DOI   ScienceOn
10 F. Demaria, R. Porcher, S. S. Ismael, G. Amarenco, X. Fritel, P. Madelenat and J. L. Benifla, 'Using intercostals muscle EMG to quantify maternal expulsive efforts during vaginal delivery : A pilot study', Neurourol. Urodyn., Vol. 23, pp. 675-678, 2004   DOI   ScienceOn
11 E. W. Van Doorn, K. Anders, V. Khullar, S. Kulsenh-Hanssen, F. Pesce, A. Robertson, D. Rosario, W. Schafer, 'Standardisation of ambulatory urodynamic monitoring : Report of the standardisation sub-committee of the international continence society for ambulatory urodynamic studies', Neurourol. Urodyn. Vol. 19, pp. 113-125, 2000   DOI   ScienceOn
12 J. H. Seo, Y. C. Jeong, C. G. Song, M. H. Ko, S. H. Park, 'Change of intra-abdominal pressure on daily activities in patients with spinal cord injury', J. Korean Continence Society, Vol. 6, pp. 54-61, 2002   DOI
13 M. L. N. G. Malbrain, 'Different technique to measure intra-abdominal pressure(IAP)', Intensive Care Med., Vol. 30, pp. 357-371, 2004   DOI
14 W. S. Cobb, J. M. Burns, K. W. Kercher, B. D. Matthews, H. J. Norton and T. H. Heniford, 'Normal intra-abdominal pressure in healthy adults', J.Surg. Res., Vol. 129, pp. 231-235, 2005   DOI   ScienceOn