레이저 파장에서의 생체 침습적 및 비침습적 광학계수 측정 방법 (Invasive and non-invasive methods for estimating the optical properties of tissue at laser wavelengths)

  • 윤길원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.147-150
    • /
    • 1994
  • To predict light propagation in biological tissues irradiated by laser, the optical properties such as absorption and scattering coefficients are required. There have been various techniques for measuring these coefficients. One method requires tissue samples, often a slab of thin tissue, is invasive. On the other hand, non-invasive method usually measures back-scattered light from a subject with no physical intervent ions. Advantages and disvantages of using different methods are investigated. A careful attention should be made in order to select the best method for a given experimental condition since, even either for invasive or non-invasive method, accuracy is subject to governing models and sample preparations.

  • PDF

피부 활성점 측정을 위한 회로설계 및 측정방법연구 (A Study on the circuit design and measurement method for the measurement of active points on skin)

  • 김민수;조영창
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.713-718
    • /
    • 2020
  • 피부 활성점(경혈) 측정 방법은 편리성, 저비용 및 비 침습으로 측정하기 때문에 많은 생체정보를 얻기 위한 기술이다. 본 연구에서는 피부 아래에 활성점을 측정할 수 있는 장점이 있는 3전극 측정방법을 사용되었다. 임피던스측정방법은 측정실험 결과와 관련성이 있는 등가전기회로를 통해서 증명되었다. 활성점의 특성주파수는 주변 피부보다 15-30Hz 높고, 리액턴스는 35-77kΩ 더 작게 측정되었다. 이 기술은 비침습 측정 시스템을 이용해서 활성점과 주변피부의 리액턴스와 특성주파수를 정확하고 객관적으로 분석되었다.

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

Validation of Non-invasive Method for Electrocardiogram Recording in Mouse using Lead II

  • Kim, Myung Jun;Lim, Ji Eun;Oh, Bermseok
    • 대한의생명과학회지
    • /
    • 제21권3호
    • /
    • pp.135-143
    • /
    • 2015
  • Electrocardiogram measures the electric impulses generated by the heart during its cycle. Recently genome-wide association studies on electrocardiogram traits revealed many relevant genetic loci. Therefore, these findings need to be validated and investigated to determine the underlying mechanisms using mouse models. Invasive radiotelemetry has been widely used to record the electrocardiogram in mice because it has several advantages over non-invasive measurements. However, radiotelemetry is expensive and requires complicated surgery. On the other hand, a non-invasive method using 3 electrodes (one for earth) for lead II is easy to establish and allows for rapid measurement. In this study, eleven mice were measured with this non-invasive method and no statistical difference among them was found in any ECG measurements. In addition, repeat measurement in the same mouse was performed in 9 sets of experiment and the results indicated that non-invasive method was reliable for reproducibility. Further it was shown that measurements for 1, 5, 10, and 15 minutes were not different so that a short recording such as 5 minutes was enough to estimate the ECG values including heart rate. Further this method was validated by measuring the ECG of Balb/c and FVB that were previously shown to differ in ECG values by radiotelemetry. Significant differences were found in heart rate, PR interval and corrected QT interval between these mouse strains. This study partially proved that non-invasive method also could provide the accuracy and reproducibility. Based on these results, the non-invasive ECG recordings of lead II is recommended as a useful method for quick test in mouse model.

비접촉식 광생체단층촬영 기술을 이용한 맥진 연구 -맥의 빠르기, 크기 및 맥력을 중심으로- (The study of non-contact/non-invasive pulse analyzing system using Optical Coherence Tomography (OCT) for oriental pulse diagnosis)

  • 나창수;윤대환;김영선;이창호;정운상;김지현;최찬헌
    • Korean Journal of Acupuncture
    • /
    • 제26권2호
    • /
    • pp.1-13
    • /
    • 2009
  • Objective: Optical Coherence Tomography (OCT) has emerged as an important optical imaging modality in non-invasive medical diagnostics. Hence, the aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by the non-contact/non-invasive pulse analyzing system using OCT on Chon(寸), Kwan(關), Chuk(尺). Method: Four korean medical doctors and the non-contact/non-invasive pulse analyzing system using OCT have measured the rapidity, the dimension, and the power of pulse waves of 25 volunteers. First, four korean medical doctors measured pulse waves of volunteers. During measuring, four doctors were separated from each other and so were volunteers. And then, the pulse waves of volunteers were measured by OCT. This was performed on the right Chon(寸), Kwan(關), Chuk(尺). Results: The study showed that the traditional method and the OCT based method had the 88% matches on the values of the slow and rapid pulse condition (遲數), 64% matches on the values of the small and big pulse condition(微細弱緩大[洪]), and 72% matches on the values of the weak and strong pulse condition(虛實). Conclusions: Based on the high similarities of the measurements of two approaches, we suggest that the OCT based pulse diagnosis method is useful for compensating the traditional method for the pulse diagnosis.

  • PDF

무채혈 혈당 측정기의 혈당 측정 원리: 혈당 검출방법 중심으로 (Blood Glucose Measurement Principles of Non-invasive Blood Glucose Meter: Focused on the Detection Methods of Blood Glucose)

  • 안원식;김진태
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권3호
    • /
    • pp.114-127
    • /
    • 2012
  • Recent technical advancement allows noninvasive measurement of blood glucose. In this literature, we reviewed various noninvasive techniques for measuring glucose concentration. Optical or electrical methods have been investigated. Optical techniques include near-infrared spectroscopy, Raman spectroscopy, optical coherence technique, polarization, fluorescence, occlusion spectroscopy, and photoacoustic spectroscopy. Electrical methods include reverse iontophoresis, impedance spectroscopy, and electromagnetic sensing. Ultrasound, detection from breath, or fluid harvesting technique can be used to measure blood glucose level. Combination of various methods is also promising. Although there are many interesting and promising technologies and devices, there need further researches until a commercially available non-invasive glucometer is popular.

오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현 (Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method)

  • 강성철;전계록;정도운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.689-692
    • /
    • 2006
  • 본 연구에서는 기존의 침습형 혈압 측정 방법의 위험성 및 불편성 등의 단점과 측정오차를 줄이고자 오실로메크릭법에 의한 혈압측정을 위하여 비관혈적인 방법으로 보다 정확하게 혈압을 추정할 수 있는 시스템을 구현하였다. 구현된 혈압 측정 시스템은 압력 제어부, 신호 측정부 그리고 혈압 신호처리부 등으로 구성하였다. 구현된 혈압측정 실험 시스템의 타당성을 검증하기 위하여 압력 측정부의 특성 평가 실험, 혈압 추정을 위한 특성비율 산출 실험, 오실로메트릭법에 의한 혈압 추정 및 평가 실험을 수행하였다. 본 연구에서 구현된 혈압 측정 실험 시스템으로 성인남성 5명을 실험 대상군으로 선정하여 데이터를 계측하고 혈압을 추정하는 실험을 한 결과 오실로메트릭에 의한 혈압 추정 및 평가 실험에서 청진법과의 평균동맥압, 수축기 혈압, 그리고 이완기 혈압에서 최대 절대편차 비율이 각각 1.38% 1.63 그리고 2.97% 이었고 최대 표준오차가 각각 5.00, 3.72, 그리고 4.34인 혈압 측정 시스템을 구현하였다.

  • PDF

비침습적 혈압 측정 시스템 구현에 관한 연구 (A Study on Implemetation of Non-invasive Blood Pressure)

  • 노영아;이종수;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.451-454
    • /
    • 2000
  • 혈압을 측정하는 방법에는 침습적(Invasive)인 방법과 비침습적(Non-invasive)인 방법이 있는데 침습적인 방법에 의한 혈압측정의 경우 정확한 값을 얻는 반면에 그 사용법이 복잡하고 환자에게 불편하므로 중환자의 경우를 제외한 경우 대부분 비침습적인 방법에 의해 혈압을 측정한다. 현재 전자 혈압계의 경우 대부분이 오실로메트릭(Oscillometric) 방법을 사용하여 기본적인 시스템을 구성하고 여기에 여러 가지 알고리즘을 부가적으로 적용하고 있다. 본 연구에서 이러한 혈압 측정 시스템을 개발하기 위해 커프(Cuff)의 압력을 제어, 측정하고 측정된 데이터를 필터링하여 혈압을 측정할 수 있도록 알고리즘을 구성하였다. 통신방식으로는 개발된 시스템의 모든 기능이 개인용 컴퓨터(Personal Computer)와의 통신을 통해 이루어지도록 구성되어져 있으며, 사용된 통신방식은 비동기 직렬 통신 방식(RS-232)인 패킷방식을 사용하였고 솔레노이드(Solenoid) 밸브를 이용한 자동 또는 급속 배기 방법을 이용하여 커프의 압력을 감압(Deflation)하였다. 혈압측정 알고리즘은 기본적인 오실로메트릭 방법과 최대 진폭 알고리즘(Maximum Amplitude Algorithm)을 사용하였다. 최대진폭 알고리즘에서는 측정된 오실레이션(Oscillation)중 최고의 진폭을 가지는 오실레이션 같은 오차의 원인이 되는 연령이나 체중, 팔의 두께에 따라 다양하게 나타난다. 본 연구에서는 오실레이션의 간에 획일적인 비율을 적용하지 않고 여러 가지 요인들에 대한 가변적인 특정 비율(Characteristic Ratio)반영하여 보다 정확한 최고혈압(Systolic Blood Pressure), 최저혈압(Diastolic Blood Pressure), 평균혈압(Mean Blood Pressure)의 값을 구하는 연구를 하였다. 최고진폭 알고리즘에서 가변적인 특성비율의 적용은 혈압간의 오차를 줄일 수 있을것으로 기대된다.

  • PDF