• Title/Summary/Keyword: non-detection zone

Search Result 50, Processing Time 0.029 seconds

A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System (PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

Detection Performance and THD Analysis of Active Frequency Drift for Anti-Islanding (단독운전 방지를 위한 능동적 주파수 변환 기법의 검출 성능 및 THD 분석)

  • Jo, Yeong-Min;Choi, Ju-Yeop;Song, Seung-Ho;Choy, Ick;Lee, Young-Kwoun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.11-19
    • /
    • 2015
  • Islanding is a phenomenon that EPS(Electric Power System) is continuously energized by PV PCS(Photovoltaic Power Conditioning System) even when EPS is isolated from the grid. Unintentional islanding will result in safety hazard, power quality degradation and many other issues. So, islanding protection of grid-connected PV PCS is a key function for standards compliance. Nowadays, many anti-islanding schemes are researched. But existing anti-islanding schemes used in PV PCS have power quality degradation and non-detection zone issues. This paper analyses not only detection performance of existed anti-islanding schemes using active frequency drift but also THD of PCS output current according to each value disturbance for anti-islanding. In addition, the lowest value of disturbance in each scheme was tabulated under guarantee of anti-islanding condition.

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement (Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.539-547
    • /
    • 2018
  • Grid-connected inverter is required to cut off the power supplied to the grid at the islanding condition, immediately. For this reason, an islanding detection is an indispensable function for grid-connected distributed generation system. Slip-Mode frequency Shift (SMS) islanding detection method is very popular method to determine the grid state. SMS method supplies the reactive power to the load according to the grid frequency. In the islanding condition of grid, this injected reactive power pulls out the grid frequency from the allowable range, then the inverter system can detect the islanding condition of the grid. The SMS method can detect the islanding state well and does not generate any harmonics of the grid current. However, the reactive power would be generated and the power quality is reduced even though the grid is not islanding condition, but normal condition. In this paper, a modified SMS method is proposed to remove the reactive power in the normal condition. The performance of the proposed method is evaluated by 600W single phase inverter experimental results.

Detection of High-Risk Human Papillomaviruses in the Prevention of Cervical Cancer in India

  • Baskaran, Krishnan;Kumar, P Kranthi;Karunanithi, Santha;Sethupathy, Subramanian;Thamaraiselvi, B;Swaruparani, S
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8187-8190
    • /
    • 2016
  • Human papillomaviruses (HPVs) are small, non-enveloped, double-stranded DNA viruses that infect epithelial tissues. Specific genotypes of human papillomavirus are the single most common etiological agents of cervical intraepithelial lesions and cervical cancer. Cervical cancer usually arises at squamous metaplastic epithelium of transformation zone (TZ) of the cervix featuring infection with one or more oncogenic or high-risk HPV (HR-HPV) types. A hospital-based study in a rural set up was carried out to understand the association of HR-HPV with squamous intraepithelial lesions (SILs) and cervical cancer. In the present study, HR-HPV was detected in 65.7% of low-grade squamous intraepithelial lesions (LSILs), 84.6% of high-grade squamous intraepithelial lesions (HSILs) and 94% of cervical cancer as compared to 10.7% of controls. The association of HPV infection with SIL and cervical cancer was analyzed with Chi square test (p<0.001). The significant association found confirmed that detection of HR-HPV is a suitable candidate for early identification of cervical precancerous lesions and in the prevention of cervical cancer in India.

Anti-islanding Method for Indirect Current Control based Utility Interactive Inverter (간접전류제어 기반의 계통연계형 인버터를 위한 단독운전방지 기법)

  • Oh, Hyeongmin;Kim, Youngwoo;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.207-208
    • /
    • 2011
  • 중요부하를 갖는 계통연계 인버터에서 계통이상시 독립운전으로 전환하여 중요부하에 지속적인 전력을 공급하여야 한다. 기존의 제어 방식은 독립운전시 전압제어를 계통연계시 전류제어를 하기 때문에 모드전환시 과도상태가 발생하고 단독운전 검출전에도 부하의 전압과 주파수가 변동하여 중요부하에 심각한 영향을 줄 수 있다. 본 논문에서는 모드 전환시 과도상태를 최소화하면서 단독운전 검출전에도 부하 전압과 주파수가 일정하게 유지하는 간접전류제어 기반의 계통연계 인버터에서 전압 고조파를 주입함으로써 NDZ(Non-Detection Zone)를 갖지 않는 단독운전방지 기법을 제안한다.

  • PDF

Modeling and Evaluation of Slip-Mode Frequency Shift Method for Anti-islanding Method (슬립모드 방식을 이용한 단독운전 검출기법의 모델링과 평가)

  • Yu, Byung-Gyu;Jung, Young-Seok;So, Jung-Hun;Yu, Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.520-522
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift (SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection zone (NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through the modeling and verified visually by simulation and experiment.

  • PDF

A Novel Anti-Islanding Scheme for Distributed Generation System via accurate Analysis of NDZ (정밀한 불검출영역 해석을 통한 분산전원 시스템의 새로운 단독운전 방지기법)

  • Jo, Yeong-Min;Gu, Bon-Ha;Choy, Ick;Song, Seung-Ho;Choi, Ju-Yeop;Lee, Young-Kwoun;Cho, Sang-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.121-122
    • /
    • 2015
  • 본 논문에서는 기존의 불검출영역(Non Detection Zone; NDZ) 해석보다 수식적으로 더욱 정밀하게 NDZ를 분석한다. 또한, 이런 NDZ를 벗어나게 하는 최소 이득의 Positive-feedback loop를 가지는 새로운 단독운전 방지기법을 설계하고, 이를 시뮬레이션과 실험을 통해 단독운전 검출 성능을 검증하고 제안하는 기법이 전력품질에 끼치는 영향을 분석한다.

  • PDF

A Study on Precision Rectification Technique of Multi-scale Satellite Images Data for Change Detection (변화탐지를 위한 인공위성영상자료의 정밀보정에 관한 연구)

  • 윤희천;이성순
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.1
    • /
    • pp.81-90
    • /
    • 2004
  • Because satellite images include geometry distortions according to photographing conditions and sensor property, and their spatial and radiational resolution and spectrum resolution are different, it is so difficult to make a precise results of analysis. For comparing more than two images, the precise geometric corrections should be preceded because it necessary to eliminate systematic errors due to basic sensor information difference and non-systematic errors due to topographical undulations. In this study, we did sensor modeling using satellite sensor information to make a basic map of change detection for artificial topography. We eliminated the systematic errors which can be occurred in photographing conditions using GCP and DEM data. The Kompsat EOC images relief could be reduced by precise rectification method. Classifying images which was used for change detections by city and forest zone, the accuracy of the matching results are increased by 10% and the positioning accuracies also increased. The result of change detection using basic map could be used for basic data fur GIS application and topographical renovation.

Anti-islanding using Active Frequency Shake Method for Grid-connected PV Generation System (계통연계형 태양광발전시스템의 AFS 기법을 이용한 단독운전 방지)

  • Ock, Seungkyu;Kang, Moonsung;Yang, Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.127-136
    • /
    • 2013
  • The islanding detection and prevention function in the important performance of the grid-connected inverter is the essential details which should be considered for worker's safety to maintain the system. This paper tries to suggest the active frequency shake islanding detection technique in the grid-connected PV generation system using sunlight. The existing active frequency drift method algorithm is described to suggest active frequency shake method algorithm. And, the algorithm which can reduce the non-detection zone, improve THD, and improve the detection speed in comparison with the existing algorithm is suggested. And we applied the proposed algorithm to the 3kW grid-connected photovoltaic inverter generation and verified the feasibility of the technique through the simulation and experiments.