• Title/Summary/Keyword: noise reducing

Search Result 1,152, Processing Time 0.024 seconds

Design for PN code Synchronous Acquisition System of DS-SS/CDMA Receiver Using New SW-DMF (새로운 SW-DMF를 이용한 DS-SS/CDMA 시스템 수신기의 PN 코드동기 포착 시스템의 설계)

  • Cho, Byung-Lok;Rhee, Kang-Hyeon;Ha, Suk-Ki
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.4
    • /
    • pp.22-32
    • /
    • 2001
  • In this paper, we propose an average acquisition time and hardware design of high speed PN code synchronous acquisition system using DMF(Digital Matched Filter) with new switching method in DS-SS/CDMA(Direct Sequence Spread Spectrum Code Division Multiple Access). In reality, the PN code synchronous acquisition system using DMF has very complicated hardware, high cost and high power consumption. The PN code synchronous acquisition system using proposed switching method DMF can overcome those disadvantages. Therefore, we can make hardware simple and obtain low power and high density by reducing the area by 1/5 against the conventional approaches of using either the matched filters or the serial correlators. The proposed system architecture is also simple and easily controllable since there is no square-term circuit after execution of digital filtering.

  • PDF

Saptio-temporal Deinterlacing Based on Edge Direction and Spatio-temporal Brightness Variations (에지 방향성과 시공간 밝기 변화율을 고려한 시공간 De-Interlacing)

  • Jung, Jee-Hoon;Hong, Sung-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.16 no.5
    • /
    • pp.873-882
    • /
    • 2011
  • In this paper, we propose an efficient deinterlacing algorithm which interpolates the missing scan lines by weighted summing of the intra and the inter interpolation pixels according to the spatio-temporal variation. In the spatial interpolation, we adopt a new edge based spatial interpolation method which includes edge directional refinement. The conventional edge dependent interpolation algorithms are very sensitive to noise due to the failure of estimating edge direction. In order to exactly detect edge direction, our method first finds the edge directions around the pixel to be interpolated and then refines edge direction of the pixel using weighted maximun frequent filter. Futhermore, we improve the accuracy of motion detection by reducing the possibility of motion detection error using 3 tab median filter. In the final interpolation step, we adopt weighted sum of intra and inter interpolation pixels according to spatio-temporal variation ratio, thereby improving the quality in slow moving area. Simulation results show the efficacy of the proposed method with significant improvement over the previous methods in terms of the objective PSNR quality as well as the subjective image quality.

Development of Data Acquistion and Processing System for the Analysis of Biophysiological signal (생체신호 처리를 위한 시스템 개발)

  • 이준하;이상학;신현진
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 1992
  • This study describes the design of the biophysiological signal processing analyzer which can collect and analyze the biosignal raw data. System hardware is consisted of the IBM PC AT. pre-amplifier. AID converter, Counter/Timer. and RS-232C processor. Biophysiological signal data were processed by the software digital filter. FFT and graphic processing routine. The tachogram and FFT of the the peak to peak interval time was accomplished by the Graphic user interface software using the biophysiological signal processed data. Using this system. the powerspectrum of the heart rate variability during the long term could be observed. Experimental results of this system approach our purpose. which is improved the cost performance. easy to use. reducing raw-data noise and optimizing model for digital filter.

  • PDF

Dynamic Characteristic Analysis of Active Gurney Flap Considering Rotational Effect (회전 효과를 고려한 Active Gurney Flap 의 동특성 해석)

  • Kee, YoungJung;Kim, TaeJoo;Kim, DeogKwan
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.183-191
    • /
    • 2015
  • In this study, the finite element analysis was carried out to investigate dynamic characteristics of the AGF(Active Gurney Flap) which is under development for reducing vibration and noise of the helicopter rotor system. The Gurney flap is a kind of small flat plate, mounted normal to the lower surface of the airfoil near to the trailing edge. An electric motor, L-shaped linkages and flap parts were integrated into a rotor bade, and 3~5/rev control was given to the AGF to reduce the vibration in the fixed frame. Thus, an explicit time integration method was adopted to investigate the dynamic response of the AGF with considering both centrifugal force due to the rotor rotation and active control input, and it can be seen that the vertical displacement of the AGF was satisfied to meet the design requirement.

AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System (인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어)

  • Park, Gwi-Geun;Choi, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

A Study on the assessment of stress using Wireless ECG (무선 심전도측정을 통한 스트레스 평가에 관한 연구)

  • Lim, Chae-Young;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2011
  • In this paper, daily life stress monitoring system is proposed. The proposed wireless ECG module, reducing the noise and increasing the size of signal, amplification circuit was designed for. Using HRV(Heart Rate Variability), extracted by measuring R-wave, stress diagnostic algorithms to assess the stress of human emotion were developed. For monitoring the activities, the proposed system is consist of small rectangular size for portable and by simple measurement it is possible to measure at any time. Through experiments, the proposed approach to represent user's stress level can be confirmed. Through that, it can see appropriate structure to obtain R-wave for stress assess as well as high resemblance to the clinical electrocardiogram. In this paper, performed experiments was developed nonrestraint measuring and wearable wireless biometric scanner that is able to monitor the heart's electrical activity of everyday life.Using this, the algorithm system, that is able to assess stress index through time-domain and frequency-domain analysis of the front and the rear of performing stress load protocol, was developed,

Image Quality Evaluation according to the Application of Air Mattress on Computed Tomography Equipment Table (전산화단층촬영장비 테이블의 에어 매트리스 적용에 따른 화질평가)

  • Jeon, Sang-Won;Pak, Jae-Yun;Suh, Tae-Suk
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.819-825
    • /
    • 2020
  • The purpose of this study was to evaluate the usefulness of the developed air mattress for reducing the deterioration of image quality due to the scattered radiation generated on the computed tomography equipment table. 5 cm and 10 cm thick air mattresses were developed and the image quality was measured by scanning the AAPM phantom according to thickness and thickness. Statistical significance was confirmed by One Way Analysis of Variance(ANOVA) Compared with the AAPM phantom scanned in the standard method, the image with the air mattress did not show any difference, but when the air mattress was not applied, the CT number and uniformity were low and the noise was high, and the spatial resolution Respectively. The developed air mattress has no harmful effect on the diagnostic image, it is very effective in improving the image quality and can increase the CT image quality by simply applying Air Mattress to existing equipment without using the technology applied to the latest and high-cost equipment.

OS CFAR Computation Time Reduction Technique to Apply Radar System in Real Time (레이다 시스템 실시간 적용을 위한 OS CFAR 연산 시간 단축 방안)

  • Kong, Young-Joo;Woo, Seon-Keol;Park, Sungho;Shin, Seung-Yong;Jang, Youn Hui;Yang, Eunjung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.791-798
    • /
    • 2018
  • The CFAR algorithm is mainly used for target detection in radar systems. In particular, OS CFAR is used in a non-uniform noise environment. However, it requires a large amount of computation, because it should sort reference cells in ascending order. This makes it difficult to apply the radar system in real time. In this paper, we describe how to reduce the computational burden of OS CFAR. We compared the power of the test cell and reference cell to determine only the presence or absence of target detection. The common reference cells overlapping in the reference cells of the three test cells are obtained. We first compare the test cell with the highest power value among the three test cells to the common reference cells. Next, we compare each test cell to general reference cells, excluding the common reference cells. The computation time is shortened by reducing the power comparison computation amounts.

A Variable Step-Size Adaptive Feedback Cancellation Algorithm based on GSAP in Digital Hearing Aids (가변 스텝 크기 적응 필터와 음성 검출기를 이용한 보청기용 피드백 제거 알고리즘)

  • An, Hongsub;Park, Gyuseok;Song, Jihyun;Lee, Sangmin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1744-1749
    • /
    • 2013
  • Acoustic feedback is perceived as whistling or howling, which is a major complaint of hearing-aids users. Acoustic feedback cancellation is important in hearing-aids because acoustic feedback degrades performance of the hearing aid device by reducing maximum insertion gain. Adaptive systems for estimate acoustic feedback path and feedback suppression algorithms have been proposed in order to solve this problem. A typical feedback cancellation algorithm is LMS(least mean squares) because of its computational efficiency. However it has problem of convergence performance in high correlated input signal. In this paper, we propose a new variable step-size normalized LMS(least mean squares) algorithm using VAD(voice activity detection) to overcome the limitation of the LMS algorithm. The VAD algorithm is GSAP(global speech absence probability) and the feedback cancellation algorithm is normalized LMS. The proposed algorithm applies different step-size between voice and non-voice using VAD, for high stability, fast convergence speed and low misalignment when correlated inputs, such as speech. The result of simulation with white noise mixed speech signal, the proposed algorithm shows high performance then traditional algorithm in terms of stability, convergence speed and misalignment.

Stress-transfer in concrete encased and filled tube square columns employed in top-down construction

  • Kim, Sun-Hee;Yom, Kyong-Soo;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.22 no.1
    • /
    • pp.63-77
    • /
    • 2016
  • Top-down construction is a construction technique in which pit excavation and structure construction are conducted simultaneously. Reducing construction time and minimizing noise and vibration which affect neighboring structures, the technique is widely employed in constructing downtown structures. While H-steel columns have been commonly used as core columns, concrete filled steel tube (CFT) columns are at the center of attention because the latter have less axial directionality and greater cross-sectional efficiency than the former. When compared with circular CFT columns, square CFT columns are more easily connected to the floor structure and the area of percussion rotary drilling (PRD) is smaller. For this reason, square CFT columns are used as core columns of concrete encased and filled square (CET) columns in underground floors. However, studies on the structural behavior and concrete stress transfer of CET columns have not been conducted. Since concrete is cast according to construction sequence, checking the stress of concrete inside the core columns and the stress of covering concrete is essential. This paper presents the results of structural tests and analyses conducted to evaluate the usability and safety of CET columns in top-down construction where CFT columns are used as core columns. Parameters in the tests are loading condition, concrete strength and covering depth. The compressive load capacity and failure behavior of specimens are evaluated. In addition, 2 cases of field application of CET columns in underground floors are analyzed.