• Title/Summary/Keyword: nm23

Search Result 951, Processing Time 0.027 seconds

Study of optimum growth condition of phase change Ge-Sb-Te thin films as an optical recording medium using in situ ellipsometry (In situ 타원법을 사용한 광기록매체용 Ge-Sb-Te 박막의 최적성장조건 연구)

  • Kim, Sang-Youl;Li, Xue-Zhe
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 2003
  • The spectroe-ellipsometric constant $\Delta$, Ψ and the ellipsometric growth curves at the wavelength of 632.8 nm are collected. These are critically examined to find out the optimum growth condition of phase change $Ge_2Sb_2Te_5(GST)$ thin films as an optical recording medium. GST films are prepared using DC magnetron sputtering technique, under the selected experimental conditions of Ar gas pressure (5 mTorr, 7 mTorr and 10 mTorr), DC power of sputtering gun (15 W, 30 W and 45 W), and substrate temperature (from room temperature to 18$0^{\circ}C$). Based on the three film model, the density distribution of deposited GST films are obtained versus Ar gas pressure and DC power by analyzing spectro-ellipsometric data. The calculated evolution curves at the wavelength of 632.8 nm, are fit into the in situ observed ones to get information about the evolution of density distribution during film growth. The density distribution showed different evolution curves depending on deposition conditions. The GST films fabricated at DC power of 30 W or 45 W, and at Ar gas pressure of 7 mTorr turned out to be the most homogeneous one out of those prepared at room temperature, even though the maximum density difference between the dense region and the dilute region of the GST film was still significant (~50%). Finally, in order to find the optimum growth condition of homogeneous GST thin films, the substrate temperature is varied while Ar gas pressure is fixed at 7 mTorr and DC power at 30 W and 45 W respectively. A monotonic decrease of void fraction except for a slight increase at 18$0^{\circ}C$ is observed as the substrate temperature increases. Decrease of void fraction indicates an increase of film density and hence an improvement of film homogeneity. The optimum condition of the most homogeneous GST film growth turned out to be 7 mTorr of Ar gas pressure, 15$0^{\circ}C$ of substrate temperature. and 45 W of DC power. The microscopic images obtained using scanning electron microscope, of the samples prepared at the optimum growth condition, confirmed this conclusion. It is believed that the fabrication of homogeneous GST films will be quite beneficial to provide a reliable optical recording medium compatible with repeated write/erase cycles.

Antioxidative Activity and Componential Analysis of Chamaecyparis obtusa Leaf Extract (편백나무 잎 추출물의 항산화 활성과 성분분석에 관한 연구)

  • Lee, Dong Sook;Lim, Myoung Sun;Kwan, Soon Sik;Kim, Sun Young;Park, Soo Nam
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.93-99
    • /
    • 2012
  • In this study, the evaluation of antioxidative activity and componential analysis of C. obtusa leaf extracts was carried out. Reactive oxygen species (ROS) scavenging activities ($OSC_{50}$) of C. obtusa leaf extracts on ROS generated in $Fe^{3+}-EDTA/H_2O_2$ system were investigated using the luminol-dependent chemiluminescence assay. The ethyl acetate fraction ($OSC_{50}$; 0.22 ${\mu}g/mL$) and aglycone fraction of C. obtusa leaf extracts (0.20 ${\mu}g/mL$) showed about 7 times more prominent ROS scavenging activity than L-ascorbic acid (1.50 ${\mu}g/mL$). The cellular protective effects of fractions obtained from C. obtusa leaf extracts on the rose-bengal sensitized photohemolysis of human erythrocytes were investigated. The ethyl acetate fraction and aglycone fraction of C. obtusa leaf extracts showed the cellular protective effects in a concentration dependent manner (5~25 ${\mu}g/mL$). The inhibitory effect ($IC_{50}$) of ethyl acetate fraction and aglycone fraction on tyrosinase exhibited 74.43 and 53.80 ${\mu}g/mL$, repectively. The aglycone fraction showed four times higher tyrosinase inhibitory effect than arbutin (226.88 ${\mu}g/mL$), known as a whitening agent. The aglycone fraction of C. obtusa leaf extracts showed three bands in TLC chromatogram and three peaks in HPLC chromatogram (360 nm). Three compounds were identified as taxifolin, quercetin and kaempferol. These results indicate that the fractions of C. obtusa leaf extracts can function as antioxidants in biological systems, particularly skin exposed to UV radiation by scavenging $^1O_2$ and other ROS, and protect cellular membranes against reactive oxygen species. The fractions of C. obtusa leaf extracts can be applicable to new functional cosmetics for antioxidan and whitening effects.

Antibacterial Activity of Hippophae rhamnoides Leaf Extract and the Stability of a Cream with the Extract (비타민나무 잎 추출물의 항균 활성 및 크림의 안정성)

  • Chae, Kyo-Young;Kim, Jung-Eun;Park, Soo-Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.1
    • /
    • pp.43-49
    • /
    • 2012
  • In this study, we investigated the antibacterial activity and stability of a cream containing Hippophae rhamnoides leaf extract. The MIC values of ethyl acetate fraction from an H. rhamnoides leaf on Escherichia coli, Pityrosporum ovale, Propionibacterium acnes and Staphylococcus aureus were 0.5%, 0.25%, 0.25% and 0.06%, respectively. Stability evaluations, pH, viscosity and absorbance of the cream containing 0.25% ethyl acetate fraction of H. rhamnoides, were performed. The cream was measured under 4 different temperature conditions under sunlight at 2-week intervals for 12 weeks. The viscosity and pH were measured by a comparison of the experimental cream with a similar control cream. The H. rhamnoides extract was found to have contributed to the stability of the emulsion product via a protective effect in maintaining the viscosity of the cream against sunlight. The absorbance variations of the experimental cream at 270 nm were, under sunlight; $45^{\circ}C$, $37^{\circ}C$, $25^{\circ}C$, and $4^{\circ}C$. In addition, any change in color or smell was not observed through the 12 weeks of the experimental period. These results indicated that the cream containing 0.25% ethyl acetate fraction of H. rhamnoides leaf extract was stable. Accordingly, this suggests that further study is needed to provide additional information for manufacturers, who are seeking the application of the extract to improve anti-oxidant and antibacterial activities and the stability of cosmetic products.

Effects of Humic Acid on the pH-dependent Sorption of Europium (Eu) to Kaolinite (PH 변화에 따른 카올리나이트와 유로퓸(Eu)의 흡착에 대한 휴믹산의 영향)

  • Harn, Yoon-I;Shin, Hyun-Sang;Rhee, Dong-Seok;Lee, Myung-Ho;Chung, Euo-Cang
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.23-32
    • /
    • 2009
  • The sorption of europium (Eu (III)) onto kaolinite and the influence of humic acids over a range of pH 3 ~ 11 has been studied by batch adsorption experiment (V/m = 250 : 1 mL/g, $C_{Eu(III)}\;=\;1\;{\times}\;10^{-5}\;mol/L$, $C_{HA}\;=\;5{\sim}50\;mg/L$, $P_{CO2}=10^{-3.5}\;atm$). The concentrations of HA and Eu(III) in aqueous phase were measured by UV absorbance at 254nm (e.g., $UV_{254}$) and ICP-MS after microwave digestion for HA removals, respectively. Results showed that the HA sorption onto kaolinite was decreased with increasing pH and their sorption isotherms fit well with the Langmuir adsorption model (except pH 3). Maximum amount ($q_{max}$) for the HA sorption at pH 4 to 11 was ranged from 4.73 to 0.47 mg/g. Europium adsorption onto the kaolinite in the absence of HA was typical, showing an increases with pH and a distinct adsorption edge at pH 3 to 5. However in the presence of HA, Eu adsorption to kaolinite was significantly affected. HA was shown to enhance Eu adsorption in the acidic pH range (pH 3 ~ 4) due to the formation of additional binding sites for Eu coming from HA adsorbed onto kaolinite surface, but reduce Eu adsorption in the intermediate and high pH above 6 due to the formation of aqueous Eu-HA complexes. The results on the ternary interaction of kaolinte-Eu-HA are compared with those on the binary system of kaolinite-HA and kaolinite-Eu and adsorption mechanism with pH was discussed.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Validation of Method Determining Coixol in Coix lachryma-jobi var. ma-yuen Roots Extract (율무근 추출물의 Coixol 성분 분석법 검증)

  • Kwon, Jin Gwan;Seo, Changon;Choi, Yun-Hyeok;Choi, Chun Whan;Kim, Jin Kyu;Jeong, Wonsik;Lee, Ji Eun;O, Kyeong Hee;Hong, Seong Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.8
    • /
    • pp.952-956
    • /
    • 2017
  • An high performance liquid chromatography (HPLC) analysis method was developed for standard determination of coixol as a functional cosmetic material in Coix lachryma-jobi var. ma-yuen roots extract. HPLC was performed on a $C_{18}$ Unison US column ($4.6{\times}250mm$, $5{\mu}m$ column) using a gradient elution of 0.1% (v/v) trifluoroacetic acid and acetonitrile at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 290 nm. The HPLC method was validated in accordance with the International Conference on Harmonization guideline of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limit of detection and quantitation were 0.07 and 0.25 mg/mL, respectively. Calibration curves showed good linearity ($R^2$>0.9995), and the precision of analysis was satisfied (less than 0.29%). Recoveries of quantified compounds ranged from 98.36 to 100.30%. This result indicates that the established HPLC method is very useful for the determination of a marker compound in C. lachryma-jobi var. ma-yuen roots extracts.

Comparison of Food Intakes and Serum Lipid Levels in Overweight and Obese Women by Body Mass Index (과체중 및 비만여성의 식습관, 식이섭취실태 및 혈청지질 양상 비교)

  • Kim, Ok-Hyun;Jung, Ha-Na;Kim, Jung-Hee
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.1
    • /
    • pp.40-49
    • /
    • 2007
  • This study was done to investigate the health-related habits, dietary intakes and serum lipid levels in overweight and obese women by body mass index(BMI). Subjects were 137 pre-menopausal women aged 19 to 49 years. They were divided by 3 groups, overweight($23{\leqq}BMI<25$), obese($25{\leqq}BMI<30$) and morbidly obese($BMI{\geq}30$) according to their BMI. Body composition was determined by bioelectrical impedance analysis(BIA) method. Dietary intakes were examined by 3-day record method and nutrient intakes were analyzed by the Computer Aided Nutritional analysis program for professionals(CAN-pro 3.1). Serum lipid levels were measured using automatic biochemical analyzer(Selectra E). The average age, height weight and BMI of subjects were 31.7 years old, 159.3cm, 69.4kg, and $27.4kg/m^2$, respectively. Their average consumption of energy were 1712kca1 and 86.4% of estimated energy requirement(EER). Their mom ratio of carbohydrate:protein:fat was 55.2:14.6:30.2. Particularly, the fat consumption of subjects tended to be elevated with increasing BMI. There was no significant difference in nutrient intakes among 3 groups. But the mom intakes of Ca, Fe, vitamin C and Na of all the subjects were 70.1%, 81.2%, 75.7% of recommended intake(RI) and 258.9% of adequate intake(AI), respectively, The intakes of vegetables and seaweeds were significantly higher in morbidly obese group while the intake of fruits was higher in overweight group compared to the other groups. Serum lipid analysis showed that there were no significant differences in the levels of total cholesterol, triglyceride and LDL-cholesterol among the groups. But the serum HDL-cholesterol level of the overweight group was significantly higher than that of the other groups. LDL-/HDL-cholesterol ratio and AI index were significantly higher in the morbidly obese group compared to the other groups. In addition, The systolic blood pressure of morbidly obese group was significantly higher compared to the other groups. Overall data suggest that morbidly obese women have to more concern about reducing systolic blood pressure and nm lipid levels by decreasing their fat consumption and salt intakes as well as loosing body fat. In addition, all the subjects participated in this study have to be careful about their meals and health-related behaviors in order to prevent obesity-related chronic diseases.

A Clinical Study on the Therapeutic Effects of the Pulsed Nd:YAG Laser on Dentinal Hypersensitivity (상아질지각과민증에 대한 펄스형 Nd: YAG 레이저의 치료효과에 관한 임상적 연구)

  • 최순정;신금백;김문현
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.11-20
    • /
    • 1998
  • 저자는 치과용 레이저를 이용한 상아질지각과민증 치료효과를 임상적으로 평가하고자 상아질지각과민증환자 24명을 대상으로 각 환자마다 상아질 지각과민 치아 중 레이저로 치료 할 치아1개(실험군)와 치료하지 않을 치아 1개(대조군)를 선정하여, 치과용 air-syringe에 의한 냉자극과 치과용 탐침자에 의한 기계적 자극을 가한 후 Visual Analogue Scale(VAS)을 통해 지각과민증 정도를 평가하였으며, 이후 실험군 치아의 치경부 마모면에 광섬유 레이저에너지 전달방식의 펄스형 Nd:YAG 레이저의 일종인 Sunlase Master(Sunrise Technologies Inc., U.S.A., 파장 1064nm, 펄스지속시간 120(sec, 광섬유직경 320(m)를 사용하여, 0.3-1.0W, 10Hz 조건으로 환자의 반응에 따라 1회2분을 초과하지 않는 범위 내에서 비접촉식과 접촉식을 병행하여 3회에 걸쳐(초진 당일, 1일후, 3일후) 레이저를 조사한 후 처음조사 직후, 그리고 초진 1일후, 3일후, 7일후, 14일후 VAS를 채득하여 조사전과 비교, 분석, 평가하였던 바, 상아질 지각과민증이 각각 약 50%, 약36%, 약45%, 약 53% 감소하였으나 (p(0.05) 경시적으로는 유의한 차이를 보이지 않았다. 그리고 24명중 9명에 대해서는 초진 30일 후 까지 레이저조사치료효과를 평가하였던 바, 상아질지각과민증이 처음조사 직후, 감소하였으며 (p(0.05)역시 경시적으로는 유의한 차이를 보이지 않았다. 초진 30일 후 상아질지각과민증이 초진 14일 후에 비해 약간 증가되는 경향을 보여, 레이저조사 치료효과가 약화되는 경향인지 여부에 대해 향후 추가적인 연구가 필요할 것으로 사료된다.안되었다.기란 현실적으로 불가능하므로, 본 연구에서는 이러한 제약점을 극복할 수 있는 근사적인 지체시간을 계산하는 방법을 제시한 점에서 의미를 갖을 수 있다.수들은 직업의 선택이나 소득을 예측하기 위한 요소들로 포함될 수 없었다. 따라서 후속연구에서는 이를 보완해야 할 것이며, 최근 들어 우리 나라에서도 재택근무에 대한 관심이 대두되고 있으나 아직 개념정의나 그 중요성과 가치, 그리고 실태 파악과 같은 연구가 활발히 이루어지지 못하고 있으므로 이에 대한 심층적인 연구가 행해져야 할 것이다.d similar flower proceeding dates in all branches. but "Daepung" showed similar flower proceeding dates in all branches.est in HB. Mean period of wetting duration was in the order of DS>HB>MB, while the dew point depression was greatest in DS.ANCOVA, Pearson correlation을 이용하여 분석하였으며, 그 결과는 다음과 같다. 캠프 프로그램은 소아 당뇨병 환자의 자기 효능을 증진시키고 환자 역할 행위 이행을 높여주는데 효과적 이었다. 소아 당뇨병 환자의 자기 효능은 환자 역할 행위 이행과 순 상관 관계가 있어, 자기 효능이 증진될수록 환자 역할 행위 이행 정도가 높아졌다. 무조건 사주지 않는다(8.0%), 무조건 사준다(3.1%)로 식품광고에 나오는 식품 요구시 부모의 70.3%가 거절하는 것으로 나타났다. 거절 이유는 건강에 나쁘다는 것이 가장 큰 이유였으며 강남과 강북 어린이간에 유의적인 차이가 있었다(p<0.001).

  • PDF

Descending Aorta Blood Flow Characteristics before the Development of Necrotizing Enterocolitis in Preterm Neonates

  • Kim, Kyung Min;Kim, Hyo Sup;Yoon, Ji Hong;Lee, Eun-Jung;Yum, Sook Kyung;Moon, Cheong-Jun;Youn, Young-Ah;Kwun, Yoo Jin;Lee, Jae Young;Sung, In Kyung
    • Neonatal Medicine
    • /
    • v.25 no.2
    • /
    • pp.78-84
    • /
    • 2018
  • Purpose: To investigate the hemodynamic risk factors for necrotizing enterocolitis (NEC), we analyzed the characteristics of descending aorta (DA) blood flow in preterm neonates, who later developed NEC. Methods: This was an observational case-control study on 53 preterm neonates at a tertiary referral center. Clinical and echocardiographic data were collected from 23 preterm neonates with NEC (NEC group), and compared with those of 30 preterm neonates without NEC (control group). Echocardiography was done at a median (interquartile range) of 5 (3-9) days after birth and 2 (1-2.5) days before the diagnosis of NEC. Results: Basic clinical characteristics including gestational age, birth weight, Apgar score, breast feeding status, use of umbilical catheters, and mode of invasive ventilator care were similar between the groups. Compared with the control group, the lowest diastolic velocity of DA was significantly decreased, whereas the diastolic reverse flow and the ratio of diastolic reverse to systolic forward flows were significantly increased in the NEC group. In addition, the resistive index (RI) of DA was significantly increased in the NEC group and showed a positive association with the development of NEC. Multivariate logistic regression analysis showed that increasing RI of DA was an independent risk factor for the development of NEC (P=0.008). Conclusion: Significant changes in DA flow characteristics including decreased diastolic velocity and increased diastolic reverse flow along with increased peripheral vascular resistance were observed before the development of NEC in preterm neonates. These findings may help clinicians stratify in advance neonates at a risk of developing NEC and may help improve outcomes in these neonates.