• Title/Summary/Keyword: nit

Search Result 232, Processing Time 0.027 seconds

Optimum Hybrid SVPWM Technique for Three-level Inverter on the Basis of Minimum RMS Flux Ripple

  • Nair, Meenu D.;Biswas, Jayanta;Vivek, G.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.413-430
    • /
    • 2019
  • This paper presents an optimum hybrid SVPWM technique for three-level voltage source inverters (VSIs). The proposed hybrid SVPWM technique aims to minimize total harmonic distortion (THD). A new parameter is introduced to incorporate the heterogeneous nature of switching sequences of SVPWM technique. The proposed hybrid SVPWM technique is implemented on a low-cost PIC microcontroller (PIC18F452) and verified experimentally with a 2 KVA three-phase three-level insulated gate bipolar transistor-based VSI. Optimum switching sequence results in the three-level inverter configuration are demonstrated. The proposed hybrid SVPWM technique improves the THD performance by 17.3% compared with the best available three-level SVPWM technique.

Numerical simulation of wedge splitting test method for evaluating fracture behaviour of self compacting concrete

  • Raja Rajeshwari B.;Sivakumar, M.V.N.;Sai Asrith P.
    • Computers and Concrete
    • /
    • v.33 no.3
    • /
    • pp.265-273
    • /
    • 2024
  • Predicting fracture properties requires an understanding of structural failure behaviour in relation to specimen type, dimension, and notch length. Facture properties are evaluated using various testing methods, wedge splitting test being one of them. The wedge splitting test was numerically modelled three dimensionally using the finite element method on self compacting concrete specimens with varied specimen and notch depths in the current work. The load - Crack mouth opening displacement curves and the angle of rotation with respect to notch opening till failure are used to assess the fracture properties. Furthermore, based on the simulation results, failure curve was built to forecast the fracture behaviour of self-compacting concrete. The fracture failure curve revealed that the failure was quasi-brittle in character, conforming to non-linear elastic properties for all specimen depth and notch depth combinations.

Parametric investigation involving response reduction for a semi-submersible floater with shape alteration, stepping, and tilting of columns and pontoons

  • Anand B. Vishnu;Abdul M. Akbar
    • Ocean Systems Engineering
    • /
    • v.14 no.3
    • /
    • pp.261-276
    • /
    • 2024
  • Numerical investigation was carried out to analyze the hydrodynamic response of 4-column semi-submersible floaters, incorporating variations such as stepping and alterations in the shape/geometry of columns and pontoons, as well as tilting of main columns. Utilizing Ansys-AQWA, a hydrodynamic software based on panel method, simulations were executed for these scenarios. The simulations yielded insights into responses, excitation forces/moments, and pressure on the structure, facilitating a comparison between the models through a parametric study. It was observed that stepping of pontoons and tilting of columns led to reduced responses, forces, and pressures, reaching balance through appropriate stepping and tilting. Additionally, altering the geometry of columns and pontoons indicated the potential benefits of employing elliptical pontoons and pentagonal columns for enhanced response control.

Clinical Benefits of Self-monitoring of Blood Glucose in Non-insulin Treated Patients with Type 2 Diabetes : A systematic Review and Meta-analysis (제 2형 당뇨 환자에서 자가혈당측정의 임상적 유용성 : 체계적문헌고찰 및 메타분석)

  • Choi, Yoon-Young;Sohn, Hyun-Soon;Shin, Hyun-Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.183-192
    • /
    • 2010
  • While Self-monitoring of blood glucose (SMBG) has been recommended in some diabetes mellitus (DM) patients population according to the 2010 American Diabetes Association (ADA), 2007 Korean Diabetes Association (KDA), 2005 International Diabetes Federation guideline, it is excluded from a routine insurance coverage for outpatients in Korea. The objective of this study is to meta-analyze the impact of SMBG on HbA1c in non insulin-treated diabetes mellitus (NIT) DM patients. Published clinical literatures were identified through electronic database searches from inception and until May 2010. Studies were selected if they met the following inclusion criteria: 1) randomized controlled trials (RCTs), 2) comparing SMBG with non-SMBG in NIT type 2 diabetes, 3) measuring HbA1c as an outcome. Literature qualities were assessed by the Scottish Intercollegiate Guidelines Network Checklist. The mean difference of HbA1c between the 2 groups was pooled from non-heterogeneous 6 RCTs by meta-analysis using Review Manger (RevMan) Version 5.0 program. Pooled results demonstrated that SMBG is associated with a statistically significant improvement in glycemic control (mean HbA1c difference -0.23, 95%CI -0.32, -0.13). Sensitivity analysis showed that glycemic controls were significantly improved in patients with shorter study duration, more frequent self-monitoring, higher baseline HbA1c value, and without prior SMBG experiences. Conclusively SMBG is effective in improving glycemic control in NIT DM patients, but additional evidences from further researches in Korean patients and cost-effectiveness analysis would be necessary to make a suggestion for coverage expansion.

A Design of Low-power/Small-area Arithmetic Units for Mobile 3D Graphic Accelerator (휴대형 3D 그래픽 가속기를 위한 저전력/저면적 산술 연산기 회로 설계)

  • Kim Chay-Hyeun;Shin Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.857-864
    • /
    • 2006
  • This paper describes a design of low-power/small-area arithmetic circuits which are vector processing unit powering nit, divider unit and square-root unit for mobile 3D graphic accelerator. To achieve area-efficient and low-power implementation that is an essential consideration for mobile environment, the fixed-point f[mat of 16.16 is adopted instead of conventional floating-point format. The vector processing unit is designed using redundant binary(RB) arithmetic. As a result, it can operate 30% faster and obtained gate count reduction of 10%, compared to the conventional methods which consist of four multipliers and three adders. The powering nit, divider unit and square-root nit are based on logarithm number system. The binary-to-logarithm converter is designed using combinational logic based on six-region approximation method. So, the powering mit, divider unit and square-root unit reduce gate count when compared with lookup table implementation.

Analytical evaluation and experimental validation of energy harvesting using low-frequency band of piezoelectric bimorph actuator

  • Mishra, Kaushik;Panda, Subrata K.;Kumar, Vikash;Dewangan, Hukum Chand
    • Smart Structures and Systems
    • /
    • v.26 no.3
    • /
    • pp.391-401
    • /
    • 2020
  • The present article reports the feasibility of the electrical energy generation from ambient low-frequency vibration using a piezoelectric material mounted on a bimorph cantilever beam actuator. A corresponding higher-order analytical model is developed using MATLAB in conjunction with finite element method under low-frequency with both damped and undamped conditions. An alternate model is also developed to check the material and dimensional viability of both piezoelectric materials (mainly focussed to PVDF and PZT) and the base material. Also, Genetic Algorithm is implemented to find the optimum dimensions which can produce the higher values of voltage at low-frequency frequencies (≤ 100 Hz). The delamination constraints are employed to avoid inter-laminar stresses and to increase the fracture toughness. The delamination has been done using a Teflon sheet sandwiched in between base plates and the piezo material is stuck to the base plate using adhesives. The analytical model is tested for both homogenous and isotropic material characteristics of the base material and extended to investigate the effect of the different geometrical parameters (base plate dimensions, piezo layer dimensions and placement, delamination thickness and placement, excitation frequency) on the model responses of the bimorph cantilever beam. It has been observed that when the base material characteristics are homogenous, the efficiency of the model remains higher when compared to the condition when it is of isotropic material. The necessary convergence behaviour of the current numerical model has been established and checked for the accuracy by comparing with available published results. Finally, using the results obtained from the model, a prototype is fabricated for the experimental validation via a suitable circuit considering Glass fibre and Aluminium as the bimorph material.

Manufacture Technology of Monoammonium phosphate from LCD Waste Acid (LCD 제조공정의 혼합폐산으로부터 일인산암모늄 제조 기술)

  • Lee, Ha-Young;Lee, Sang-Gil;Park, Sung-Kook;Kim, Ju-Han;Kim, Ju-Yup;Kim, Jun-Young
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.253-257
    • /
    • 2009
  • The waste solution discharged form the LCD(Liquid Crystal Display) manufacturing process contains phosphoric acid, nitric acid, acetic acid and metal ions such Al and other impurities. In this study, vacuum evaporation and diffusion dialysis was developed to commercialize an efficient system for recovering the high-purity phosphoric acid and manufacturing monoammonium phosphate. By vacuum evaporation, almost 99% of nitric and acetic acid was removed. Also, by diffusion dialysis, about 97.5% of Al was removed. Monoammonium phosphate was manufactured from purified phosphoric acid and ammonium hydroxide. In order to get the optimum manufacturing condition, the molar ratio of ammonium hydroxide and phosphoric acid, pH and temperature was controlled. Using this optimum condition, we obtained the recovery rate of monoammonium phosphate of about 90%.

Changes of Nitrifying Bacteria Depending on the Presence and Absence of Organic Pollutant in Nak-Dong River (낙동강에서의 유기성 오염 유무에 따른 질화세균의 변화)

  • Jin, Seon-Yeong;Lee, Young-Ok
    • Korean Journal of Microbiology
    • /
    • v.49 no.2
    • /
    • pp.137-145
    • /
    • 2013
  • This study was performed at 2 sites of Nak-Dong River to investigate the changes of nitrifiers depending on the presence and absence of organic pollutants (due to the effluents of domestic wastewater treatment plant, WWTP). Conventional chemical parameters such as T-N, $NH_4$-N, $NO_2$-N, $NO_3$-N were measured and the quantitative nitrifiers at the 2 sites were analyzed comparatively by fluorescent in situ hybridization (FISH) with NSO190 and NIT3, after checking the presence of gene amoA of ammonia oxidizing bacteria (AOB) and 16S rDNA signature sequence for Nitrobacter sp. that belongs to nitrite oxidizing bacteria (NOB). Also ${\alpha}{\cdot}{\beta}{\cdot}{\gamma}$-Proteobacteria were detected using FISH to get a glimpse of the general bacterial community structure of the sites. Based on the distribution structure of the ${\alpha}{\cdot}{\beta}{\cdot}{\gamma}$-Proteobacteria and the measurement of nitrogen in different phases, it could be said that the site 2 was more polluted with organics than site 1. Corresponding to the above conclusion, the average numbers of AOB and NOB detected by NSO160 and NIT3, respectively, at site 2 [AOB, $9.3{\times}10^5$; NOB, $1.6{\times}10^6$ (cells/ml)] was more than those at site 1 [AOB, $7.8{\times}10^5$; NOB, $0.8{\times}10^6$ (cells/ml)] and also their ratios to total counts were higher at site 2 (AOB, 27%; NOB, 34%) than those at site 1 (AOB, 18%; NOB, 23%). Thus, it could be concluded that the nitrification at site 2 was more active due to continuous loading of organics from the effluents of domestic WWTP, compared to site 1 located closed to raw drinking water supply and subsequently less polluted with organics.