• Title/Summary/Keyword: new waveform

Search Result 428, Processing Time 0.022 seconds

Research on Subcutaneous Pulse Shape Measurement by Near-infrared Moiré Technique

  • Chen, Ying-Yun;Liu, Zhizhen;Du, Jian;Chang, Rong-Seng
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • A pulse is generated when the heart pumps blood into the arterial system. The heart pumps blood only when it contracts, not when it relaxes; therefore, blood enters the arterial system in a cyclical form. Artery beating is visible in some parts of the body surface, such as the radial artery of the wrist. This paper mainly uses the feature in which near-infrared spectroscopy penetrates skin to construct a non-invasive measurement system that can measure small vibration in the subcutaneous tissue of the human body, and then uses it for the pulse measurement. This measurement system uses the optical moir$\acute{e}$ principle, together with the fringe displacement made by small vibration in the subcutaneous tissue, and an image analysis program to calculate the height variation from small vibrations in the subcutaneous tissue. It completes a measurement system that records height variation with time, and that together with a fast Fourier transform (FFT) program, they can convert the pulse waveform generated by vibration (time-amplitude) to heartbeat frequency (frequency-amplitude). This is a new and non-invasive medical assistance system for measuring the pulse of the human body, with the advantages of being simple, fast, safe and objective.

A Comparative Study of Glottal Data from Normal Adults Using Two Laryngographs

  • Yang, Byung-Gon;Wang, Soo-Geun;Kwon, Soon-Bok
    • Speech Sciences
    • /
    • v.10 no.1
    • /
    • pp.15-25
    • /
    • 2003
  • A laryngograph was developed to measure the open and closed movements of vocal folds in our laboratory. This study attempted to evaluate its performance by comparing its glottal data with that of the original laryngograph. Ten normal Korean adults Participated in the experiment. Each subject produced a sustained vowel /a/ for about five seconds. This study compared f0 values, contact quotients of the duration of closed vocal folds over one glottal pulse, and area quotients of the closed over open vocal folds derived from glottal waves using both the original and new laryngographs. Results showed that the mean and standard deviation of the two laryngographs were almost comparable with a correlation coefficient 0.662 but minor systematic shift below those of the original laryngograph was observed. The absolute mean difference converged into 1 Hz, which indicates a possibility of adopting some threshold of rejecting inappropriate pitch values beyond a threshold value. The contact quotient of the normal subjects came out slightly over the 50% in a citation speech. Finally, the area quotient converged into 1. We will pursue further studies on the abnormal patients in the future.

  • PDF

Double-tuned Filter Design For HVDC System (HVDC System 적용 Double-tuned 필터의 설계 방법 연구)

  • Lee, Hee-Jin;Nam, Tae-Sik;Son, Gum-Tae;Park, Jung-Wook;Chung, Yong-Ho;Lee, Uk-Hwa;Baek, Seung-Taek;Hur, Kyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1232-1241
    • /
    • 2012
  • The ac side current of an high voltage direct current (HVDC) converter is characterized by highly non-sinusoidal waveform. If the harmonic current is allowed to flow in the connected ac system, it may cause unacceptable levels of distortion. Therefore, ac side filters are required as part of the total HVDC converter station, in order to reduce the harmonic distortion of the ac side current and voltage to acceptably low levels. The ac side filters are also employed to compensate network requested reactive power because HVDC converters also consume substantial reactive power. Among different types of filters, double-tuned filters have been widely utilized for HVDC system. This paper presents two design methods of double-tuned filter; equivalent method and parametric method. Using a parametric method, in particular the paper proposes a new design algorithm for a realistic system. Finally, the performance of the design algorithm is evaluated for a 80kV HVDC system in Jeju island with PSCAD/EMTDC program. The results cleary demonstrate the effectiveness of proposed design method in harmonics elimination and steady-state stability.

Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

A Study on Simple Single phase Air-conditioner of Power factor Correction Circuit (심플한 단상 에어컨의 역률개선회로에 관한 연구)

  • 문상필;서기영;이현우;김영문;김영철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • This paper describes the simple single phase air-conditioner of power factor correction (PFC) circuit. By adopting PFC in the rectifier, we can reduce harmonic into power line, improve the efficiency and lower the total system cost compared to conventional inviter only. Also, system performance is improved by stabilizing the output voltage of PFC. To improve the current waveform of diode rectifiers, we propose a new operating principle for the voltage diode rectifiers. A circuit design method is shown by experimentation and confirmed simulation. It explained that compared conventional pulse-width modulated (PWM) inverter with half pulse-width modulated (HPWM) inverter HPWM inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting.

  • PDF

The Enhanced Power Analysis Using Linear Discriminant Analysis (선형판별분석을 이용한 전력분석 기법의 성능 향상)

  • Kang, Ji-Su;Kim, HeeSeok;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1055-1063
    • /
    • 2014
  • Recently, various methods have been proposed for improving the performance of the side channel analysis using the power consumption. Of those method, waveform compression method applies to reduce the noise component in pre-processing step. In this paper, we propose the new LDA(Linear Discriminant Analysis)-based signal compression method finding unique feature vector. Through experimentations, we are comparing the proposed method with the PCA(Principal Component Analysis)-based method which has known for the best performance among existing signal compression methods.

High Resolution FMCW Level Gauge with Narrowband FMCW Radar (협대역 FMCW 레이더를 이용한 고해상도 레벨게이지)

  • Eum, Soung-Hyun;Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.899-905
    • /
    • 2012
  • Level Gauge using FMCW Radar is widely used and researched in many areas because of contactless, long range and flexibility. However FMCW level gauge requires wideband RF bandwidth for archiving high resolution of cm grade. In this paper we propose a new tx sawtooth waveform and processing algorithm with narrowband RF for wideband performance. The proposed method is based on STFT(Short-time fourier transform) and single sinusoidal carrier estimation method. From some experiments, we show that the resolution is improved upto 8 times with 300MHz FMCW radar.

Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact (광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상)

  • Huh, Young-Jung;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

A Study of Discharge Shape Changes by Magnet Arrangements in a Magnetron Cathode (마그네트론 음극의 자석 배열에 따른 방전의 형상 변화 연구)

  • Jee, Jung-Eun;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.3
    • /
    • pp.94-101
    • /
    • 2008
  • A new convenient magnet array module is designed to investigate effects of magnetic field array on magnetron discharge characteristics. Magnetic field analysis showed good agreement of measured discharge region by a CCD device which has a high quantum efficiency over visible wavelength range. OES (optical emission spectroscopy) showed major emission peaks are from electronic transitions in 400 nm range and 800 nm range. Effects of driving voltage characteristics were analyzed in a point of electron drift trajectories and ionizing collision frequencies. Pulsed dc with a fast rising and falling time was analyzed to have potential to increase ionization collisions by putting a burst of hot electrons and to raise sheath potential. From measured voltage and current waveform, maximum of -1000 V peak was generated with $-400\;V_{rms}$ conditions. Possibility of a properly designed magnetron cathode was shown to be used as a melting device. Cu was successfully melted with power density of a several tens of $W/cm^2$.

Numerical Analysis of the Discharge and Luminous Characteristics of a Planar Type Xe Plasma Flat Lamp (대향형 Xe 플라즈마 평판 램프의 방전 및 발광 특성에 관한 수치적 연구)

  • Kim, Hyuk-Hwan;Lee, Won-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.10
    • /
    • pp.822-833
    • /
    • 2011
  • A Xe plasma flat lamp, which has been noticed as a new eco-friendly LCD (liquid crystal display) backlight, requires the improvement of the luminance and the luminous efficiency although it has several advantages. To improve the performance of a lamp, it is necessary to understand the effects of discharge variables on the luminous characteristics of the lamp. Since it is difficult to diagnose a lamp discharge experimentally, the numerical analysis can be used instead. In this study, the luminous characteristics of a planar type Xe plasma flat lamp were analyzed with the variation of an input voltage and a pulse frequency. The numerical analysis of a lamp discharge was then performed using a RCT (relaxation continuum) model and a LFA (local field approximation) model. The comparison with the experimental results showed that the RCT model is valid for the numerical analysis of the flat lamp. The numerical analysis also showed that the modifications of a high frequency component and a voltage falling rate in the input voltage waveform could improve the luminous characteristics of the lamp.