• Title/Summary/Keyword: new test method

Search Result 3,984, Processing Time 0.043 seconds

Repeatability and Reliability of a New Phoria Test Using Flashed and Auto-flashed Presentation

  • Moon, Byeong-Yeon;Park, Sun-Young;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.418-424
    • /
    • 2012
  • The purpose of this study was to assess repeatability and reliability of a new phoria test as compared to established phoria tests and to assess the possibility of mobile or online testing using the auto-flashed presentation. Near dissociated phoria was measured using the von Graefe method, the Howell card test, the modified Thorington test, and a new dichromatic card test (Red-Blue Phoria card test; RBP card test) on 109 subjects. The inter-examiner difference and test-retest difference were calculated. With the auto-flashed presentation of the RBP card test, near dissociated phoria was measured and the intraclass correlation coefficient and test-retest repeatability was assessed on 26 subjects. The variation in inter-examiner repeatability was the smallest for the modified Thorington test (+3.1/-2.6). The RBP card test was +3.0/-3.1, the Howell card test was +3.5/-2.7, and the von Graefe test was +6.2/-6.0. The variation in test-retest repeatability was the smallest for the RBP card test (+0.4/-1.4). The modified Thorington test was +1.3/-1.3, the Howell card test was +1.27/-1.45, and the von Graefe test was +1.59/-2.20. The ICC was 0.919 for the auto-flashed presentation of the RBP card test. The RBP card test is considered a highly repeatable method clinically and can be made a useful application for testing in mobile or online.

Studies on Sensory Evaluation -[Part IV] New Modified Triangle Test- (관능검사(官能檢査)에 관한 연구(硏究) -[제4보(第4報)] 3점비교법(點比較法)의 신변형(新變形)에 대하여-)

  • Hong, Jin
    • Applied Biological Chemistry
    • /
    • v.20 no.3
    • /
    • pp.285-291
    • /
    • 1977
  • In this paper the new statistical method called "New Modified Triangle Test" is studied. This method is to test the null hypothesis based on the result which comes from evaluating sample size "t", where $t{\geqq}3$, by using Triangle Preference Scale Test. It a confirmed that "New Modified Scheffe's Method 1" can be used for appraising "New Modified Triangle Test". In this report, the weight fraction of in-correct oddity chosen to correct oddity chosen is made 1/2 in terms of chance probability.

  • PDF

A Measurement Using the Test Zig for HDMI Connector (측정용 지그를 활용한 HDMI 콘넥터 측정법)

  • Yi, Sang-Hoi;Jeong, Jae-Yong
    • 전자공학회논문지 IE
    • /
    • v.46 no.3
    • /
    • pp.48-54
    • /
    • 2009
  • In this paper, a test method of HDMI connectors is developed using a test zig. This method is used to test the characteristic for a digital signal connector, and is applied the compliance test specification. The test results of connectors for the two manufactory are implemented by the new proposed method. Finally, it is suggested to the new test method of HDMI connector in this paper, and is applied to the simple test method of connector in manufactory.

A Study on the Pull-out test for Non-Destructive Evaluation of Concrete Strength (콘크리트 비파괴강도 추정을 위한 인발시험법에 대한 연구)

  • 한만엽;김동욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.639-642
    • /
    • 1999
  • Pullout test known as Lok test among the test methods to evaluate concrete strength strength is a test method which is used to decide the form removal time by assessing the early strength of concrete in a new construction, or to control the quality of newly placed concrete. This method has inconvenience to place inserts on the form work in advance, however, the placing work is quite simple and it has advantage that the strength can be measured at field as long as the inserts are placed. In this study, the first step is to investigate the properties of test method itself, by performing the laboratory test which covers deviation of the method and factors affecting the results, etc. The second step is to correlate the result with cylinder strength and other NDT methods such as rebound hammer, ultrasonic method, etc. And that, the results are compared with foreign results to find the differences between the two. In this research, new factors such as moisture content, area of aggregate failure cross section and area of aggregate separation cross section, etc as well as wate-cement ratio and age are investigated.

  • PDF

A Comparative Performance Test for Turbine in Wind Tunnel and Towing Tank (풍동과 예인 수조를 이용한 터빈 성능 비교 시험)

  • Kang, Jung-Min;Lee, Yeong-Ho;Lee, Kyu-Chan
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.42-49
    • /
    • 2011
  • The objective of this paper is to suggest a new method of a wind turbine performance test. The performance test of a wind turbine is generally carried out in a wind tunnel. The test needs not only a high-accuracy measuring system but also durable structure to withstand high speed turbine rotation and wind flow. Therefore, we tried turbine performance test using a towing tank to improve stability and reliability. Because a turbine rotates more slowly and generates more torque in the water than in the wind tunnel under similarity conditions. In this study, we developed turbine performance test systems and verified the turbine test method using a towing tank through comparing results of the wind tunnel and the towing tank test.

New Inspection Skill for Load-test of Hydraulic Elevator without Actual Loads (엘리베이터 하중시험 대체 검사기법 개발)

  • Heo, Yun-Seop;Eom, Yong-Gi
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.127-132
    • /
    • 2013
  • In order to check traction of the elevator, the load-test is positively necessary on the inspection of elevator in Korea. So actual loads are used in the elevator car for the load-test. However, some of advanced countries in Europe, for example Germany, are using the alternative method with no load test instead of traditional load-test. Commonly hydraulic elevator, compared to passenger elevator is mainly used for loading heavy weights. It requires a great deal of labor to carry out load-test. The reason is why we developed a new inspection skill for the load-test of hydraulic elevator without actual loads. The results of studies show that the new method of the load-test can be replace the traditional load-test.

Developing the Optimized Method of Reliability-Growth Target Setting for Complex and Repairable Products from Business View

  • So, Young-Kug;Jeon, Young-Rok;Ryu, Byeong-Jin
    • Journal of Applied Reliability
    • /
    • v.15 no.4
    • /
    • pp.248-255
    • /
    • 2015
  • Purpose : The purpose of this research is to develop the optimized method and process in the reliability-growth target setting, especially for complex and repairable system (or products) such as vehicle and airplane, construction equipment. Method : A reliability-growth test plan specifies a scenario to achieve the planned reliability value (or reliability target). The major elements in test planning are reliability-growth starting time and reliability level at that time, reliability-growth rate and reliability-growth target. All of them except a reliability target can be referred to the previous development data and reference researches. The reliability target level is directly influencing to test period (or time) which is related to test and warranty cost together. There are a few researches about the reliability target setting method and but showing the limitations to consider the views of engineering, business and customer together. There is no research how to handle the target setting process in detail. Result : We develop the optimized method and systematic process in reliability target setting with considering such views. This research also establish the new concept as production capability which means company (or supplier) capability to product its products. Conclusion : In this research result, we apply the new method to a few projects and can set the reasonable test planning. The developing results is showing the good balance between the developing cost and warranty cost at market.

Proposal of Bond Strength Evaluation Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • 장흥균;홍창우;정원경;이봉학;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.349-354
    • /
    • 2002
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesion strength measurement method ignores the effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF

Test Pattern Generation in VHDL Design using Software Testing Method (소프트웨어 검사방법을 이용한 VHDL 설계에서의 테스트 패턴 생성)

  • 박승규;김종현김동욱
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1065-1068
    • /
    • 1998
  • This paper proposes a new test generation method. Most of the test generation methods are gate-level based, but our scheme is VHDL based, especially in other word, behavioral-level based. Our test pattern generation method uses software test method. And we generate deterministic test pattern with this method. The purpose of our method is to reduce the time and effort to generate the test patterns for the end-product test of IC.

  • PDF

Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition (연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석)

  • Kim, Kyungsoo;Yun, Jaeho
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.