• Title/Summary/Keyword: neutral line

Search Result 327, Processing Time 0.029 seconds

H1R4: Mock 21cm intensity mapping maps for cross-correlations with optical surveys

  • Asorey, Jacobo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.56.3-56.3
    • /
    • 2019
  • We are currently living in the era of the wide field cosmological surveys, either spectroscopic such as Dark Energy Spectrograph Instrument or photometric such as the Dark Energy Survey or the Large Synoptic Survey Telescope. By analyzing the distribution of matter clustering, we can use the growth of structure, in combination with measurements of the expansion of the Universe, to understand dark energy or to test different models of gravity. But we also live in the era of multi-tracer or multi-messenger astrophysics. In particular, during the next decades radio surveys will map the matter distribution at higher redshifts. Like in optical surveys, there are radio imaging surveys such as continuum radio surveys such as the ongoing EMU or spectroscopic by measuring the hydrogen 21cm line. However, we can also use intensity mapping as a low resolution spectroscopic technique in which we use the intensity given by the emission from neutral hydrogen from patches of the sky, at different redshifts. By cross-correlating this maps with galaxy catalogues we can improve our constraints on cosmological parameters and to understand better how neutral hydrogen populates different types of galaxies and haloes. Creating realistic mock intensity mapping catalogues is necessary to optimize the future analysis of data. I will present the mock neutral hydrogen catalogues that we are developing, using the Horizon run 4 simulations, to cross-correlate with mock galaxy catalogues from low redshift surveys and I will show the preliminary results from the first mock catalogues.

  • PDF

LYα LINE FORMATION IN HUBBLE-TYPE SPHERICAL OUTFLOWS IN STARBURST GALAXIES

  • AHN SANG-HYEON;LEE HEE-WON
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.4
    • /
    • pp.175-185
    • /
    • 2002
  • Almost half of primeval galaxies show P-Cygni type profiles in the Ly$\alpha$ emission line. The main underlying mechanism for the profile formation in these systems is thought to be the frequency re-distribution of the line photons in expanding scattering media surrounding the emission source. A Monte Carlo code is developed to investigate the Ly$\alpha$ line transfer in an optically thick and moving medium with a careful consideration of the scattering in the damping wings. Typical column densities and expansion velocities of neutral hydrogen investigated in this study are $N_{H1}{\~}10^{17-20}\;cm^{-2}$ and ${\Delta}V{\~} 100 km\;s^{-1}$. We investigate the dependence of the emergent profiles on the kinematics and on the column density. Our numerical results are applied to show that the damped Ly$\alpha$ absorbers may possess an expanding H I supershell with bulk flow of ${\~}200 km\;s^{-l}$ and H I column density $N_{H1}{\~}10^{19}\;cm^{-2}$. We briefly discuss the observational implications.

Comparison of Voltage Unbalance Factor for Line and Phase Voltage (선간전압과 상전압에 대한 전압불평형율의 비교)

  • Kim Jong-Gyeum;Park Young-Jeen;Lee Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.403-407
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetric components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved by the unbalanced load at the 3-phase 4-wire system. Line and phase voltage unbalance leads to different results due to zero-sequence component. So that it is difficult to analyse voltage unbalance factor by the conventional analytical method, This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

A Study of the Pitch Measurement Location and Reference Line for a Research of Declination in Korean (한국어의 점진하강(declination) 연구를 위한 음높이 측정 위치와 기준선 고찰)

  • Kwak, Soook-Young;Shin, Ji-Young
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.75-84
    • /
    • 2009
  • The aim of this paper is to find an adequate method to study declination in Korean. In previous studies of declination in Korean, maximum and minimum pitch values in an accentual phrase were measured. But this method is inadequate when an accentual phrase is located at the intonational phrase. So in order to exclude the final tone of an intonational phrase, we propose to measure pitch values of the first and second tone in an accentual phrase when the tonal pattern of the accentual phrase is 'LHLH'. In this case, the line that connects every first tone of an accentual phrase is the baseline, and the line that connects every second tone of an accentual phrase is the topline. By a comparison of declination between focused and neutral utterances, we will show that the topline of declination is more direct to the speaker's plan than the baseline.

  • PDF

Nitric Oxide Production Ability and its Formation Mechanisms in Macrophage TIB 71 Cell Line by Polysaccharide Extracted from Ganoderma lucidum (영지버섯 다당체의 Nitric Oxide 생성능 및 생성기전 연구)

  • 김성환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.2
    • /
    • pp.333-337
    • /
    • 1998
  • This study was carried out to get infomation on the nitric oxide production ability and its formation mechanisms of polysaccharides extracted from Ganoderma lucidum(PSG) by using murine macrophage cell line. The cultured mycelial cells of Ganoderma lucidum were extracted by alkali, and than neutralized by acid. The extract were passed through the column of DEAE cellulose for more purification. The neutral fraction was concentrated and precipitated with 95% ethanol. The precipitate was lyophilized and PSG was obtained. The immunomodulating effects of PSG on macrophage were performed by using murine macrophage cell line ATCC TIB 71 cells with PSG 0.5mg. PSG alone could not induce the production of nitrite, but it had a significant potential effect on nitrite secretion when the cells were primed and triggered with BCG and Interferon(IFN)-${\gamma}$. Also it was prominent by using calcium channel blocker(verapamil) and adenylate cyclase activator(forskolin).

  • PDF

태양활동영역에서 Magnetic Polarity Inversion Line의 기하학적, 물리적 특성에 대한 통계적 연구

  • Lee, Eo-Jin;Park, Seong-Hong;O, Su-Yeon;Lee, Yu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.114.2-114.2
    • /
    • 2012
  • 태양 광구표면에서 시선방향 자기장 자료를 살펴보면 그 극성이 변하는 지점들이 선의 형태로 보이는데 이것을 Magnetic Polarity Inversion Line(MPIL) 혹은 Neutral Line이라 부른다. 기존의 연구에 의하면 태양활동영역에서 MPIL의 길이가 길수록 플레어 및 코로나물질방출(CME)과 같은 큰 규모의 분출현상들이 일어나는 빈도가 높다는 사실이 보고된 바 있다. 이런 점에서 볼 때 MPIL이 우주환경 예보의 측면에서 중요한 도구가 될 수 있을 것으로 기대된다. 하지만 여전히 MPIL의 기하학적, 물리적 특성 및 그 형성과 진화과정에 대한 이해가 부족한 상황이다. 우리는 본 연구에서 SOHO/MDI 시선방향 자기장 자료를 사용하여 태양활동 23주기에 나타난 308개의 태양활동영역에 대하여 MPIL의 길이, 곡률과 같은 기하학적인 특성을 연구하였고, 또한 MPIL주변의 자기장(평균 자기선속, 총 자기선속 등) 및 magnetic fragment들의 속도장(평균속력, 수렴 및 발산정도, vorticity 등)과 같은 물리적인 특성에 대한 통계적 조사를 수행하였다.

  • PDF

The surge characteristics research of an electrodeless fluorescent lamp system (무전극 형광램프 시스템의 서어지 특성 연구)

  • Lee, Se-Hyun;Shin, Sang-Wuk;Cho, Mee-Ryoung;Hwang, Myung-Keun;Ham, Jung-Keol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.141-148
    • /
    • 2004
  • In this paper, we have investigated the inductive voltages, currents, frequencies of output line of electrodeless fluorescent lamp system as an surge is supplied and have analyzed the surge characteristics as an phase alteration of input voltage with an surge suppling. A result os measurement is that the inductive over-voltages(H-PE, N-PE) on output line of electrodeles fluorescent lamp system showed more high than inductive overvoltages of H(hot)-N(neutral) line. Therefore, designer of system will lay emphasis on an protective circuit with considening an overvoltage(H-PE, N-PE) or phase of input voltage.

  • PDF

The Basic Insulation Design of 60 kV Bushing for Netural Line of 154 kV Class HTS Transformer (154 kV급 고온초전도 변압기의 중성선용 60 kV 부싱의 기초 절연설계)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.32-35
    • /
    • 2008
  • A common problem in many fields of cryogenic power engineering is applying high voltage to cold parts of superconducting apparatus. In many cases, a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The 60 kV class cryogenic high voltage bushing for neutral line of the 154 kV / 100MVA high temperature superconducting (HTS) transformer was described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors; in the axial direction, there was a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, electrical insulation characteristics of the GFRP were discussed in this paper.

An Induced Voltage Calculation on Telecommunication Line of Two Step Type Pole in Distribution Lines (2단 장주로 구성된 배전선로의 인접 통신선에 대한 유도전압 계산)

  • Kim, Hyoun-Su;Rhee, Sang-Bong;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.148-150
    • /
    • 2007
  • This paper presents a calculation method of an induced voltage on telecommunication lines using primitive impedance matrix. The advantages of the method are using actual neutral current value and not using screening factor for considering the overhead ground wire and neutral wire. To verify the effectiveness and accuracy of the method, case studies are performed with EMTP (Electro-Magnatic Transient Program).

  • PDF

Determination of neutral reactor and reclosing time for long 400 kV transmission line (400 kV 급 장거리 송전선로의 Neutral Reactor 용량과 재폐로 무전압 시간산정)

  • Kwak, J.S.;Kang, Y.W.;Joo, H.J.;Kweon, D.J.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.664-666
    • /
    • 2005
  • 본 논문에서는 장거리 초고압 송전선로에서의 단상재폐로시에 발생가능한 과전압과 2차아크전류를 EMTP를 이용하여 예측계산 하였다. 예측계산결과로부터 과전압을 억제하고 재폐로 동작이 가능한 최적의 중성점 리액터와 400 kV 급 수평배열 1회선 선로를 단상으로 재폐로 하는데 필요한 재폐로 무전압시간을 구하였다.

  • PDF