• 제목/요약/키워드: neutral heating

검색결과 98건 처리시간 0.023초

Performance of Beam Extractions for the KSTAR Neutral Beam Injector

  • Chang, D.H.;Jeong, S.H.;Kim, T.S.;Lee, K.W.;In, S.R.;Jin, J.T.;Chang, D.S.;Oh, B.H.;Bae, Y.S.;Kim, J.S.;Cho, W.;Park, H.T.;Park, Y.M.;Yang, H.L.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.240-240
    • /
    • 2011
  • The first neutral beam injector (NBI-1) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. A first long pulse ion source (LPIS-1) has been installed on the NBI-1 for an auxiliary heating and current drive of KSTAR core plasmas. Performance of ion and neutral beam extractions in the LPIS-1 was investigated initially on the KSTAR NBI-1 system, prior to the neutral beam injection into the main plasmas. The ion source consists of a JAEA magnetic bucket plasma generator with multi-pole cusp fields and a set of KAERI prototype-III tetrode accelerators with circular apertures. The inner volume of plasma generator and accelerator column in the LPIS-1 is approximately 123 liters. Final design requirements for the ion source were a 120 kV/ 65 A deuterium beam and a 300 s pulse length. The extraction of ion beams was initiated by the formation of arc plasmas in the LPIS-1, called as an arc-beam extraction method. A stable ion beam extraction of LPIS-1 has been achieved up to an 100 kV/42 A for a 4 s pulse length and an 80 kV/25 A for a 14 s pulse length. Optimum beam perveance of 1.21 microperv has been found at an accelerating voltage of 80 kV. Neutralization efficiency has been measured by using a water flow calorimetry (WFC) method of calorimeter and an operation of bending magnet. The full-energy species of ion beams have been detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6~1.1 A/kW depending on the operating conditions of arc discharge.

  • PDF

산성컬러 염색제로 모발 염색 시 열처리에 따른 세척 전과 세척 건조 후 색차 및 색변화에 관한 연구 (The Research on the Differences & Changes in Hair Color Before v.s. After shampoo and Dry on Different Heat Processes When Acid Hair Color Dyeing)

  • 안현경
    • 패션비즈니스
    • /
    • 제16권1호
    • /
    • pp.69-82
    • /
    • 2012
  • This thesis aimed to reduce the differences of hair color when hair coloring, so it researched the differences & changes in hair color before shampoo v.s. after shampoo and dry on different heat processes when acid hair color dyeing. Five hair color dyes (Y, R, B, G, Br) manufactured by two different corporations were used. The acid hair color dyes were tinted on black and bleached hair pieces subjected to 3 different heat process; 1. Normal Temperature($25^{\circ}C$, 30min.) / 2. Heating($40^{\circ}C$, 15min.)+Normal Temperature($25^{\circ}C$, 15min.) / 3. Heating($40^{\circ}C$, 30min.). Color numbers were divided by NCS value, chroma, and hue. Statistical averages were derived and t-test was conducted using SPSS V12. Hair color differences and changes were drawn on an NCS chart using Photo Shop PS. The conclu is; If acid hair colorings are separated by a heating process, hair value & chroma change before shampoo vs. after shampoo & dry regardless of the color of hair and the heat process. Hue is not changed or shifted counter clockwise NCS color circle, but some exceptions, and it's the same when the total heat process results are combined. Black hair's value shifted downward and chroma left, and hue stayed either neutral or one color or it shifted counter clockwise on NCS color circle. Bleached hair's value shifted upward and chroma right, and hue stayed one color or shifted counter clockwise, but some exceptions. And it can be shown on NCS chart.

SF6/N2 혼합기체의 DC 플라즈마 특성 분석 (The Analysis of DC Plasmas Characteristics on SFSF6 and N2 Mixture Gases)

  • 소순열
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1485-1490
    • /
    • 2014
  • $SF_6$ gas has been used for power transformers or gas insulated switchgears, because it has the superior insulation property and the stable structure chemically. It has been, however, one of global warming gases and required to reduce the its amount. Some papers have reported that its amount could be reduced by mixing with other gases, such as $N_2$, $CF_4$, $CO_2$ and $C_4F_8$ and their mixture gases would cause the synergy effect. In this paper, we investigated the characteristics of DC plasmas on $SF_6$ mixture gases with $N_2$ at atmospheric pressure. $N_2$ gas is one of cheap gases and has been reported to show the synergy effect with mixing $SF_6$ gas, even though $N_2$ plasmas have electron-positive characteristics. 38 kinds of $SF_6/N_2$ plasma particles, which consisted of an electron, two positive ions, five negative ions, 30 excitation and vibration particles, were considered in a one dimensional fluid simulation model with capacitively coupled plasma chamber. The results showed that the joule heating of $SF_6/N_2$ plasmas was mainly caused by positive ions, on the other hand electrons acted on holding the $SF_6/N_2$ plasmas stably. The joule heating was strongly generated near the electrodes, which caused the increase of neutral gas temperature within the chamber. The more $N_2$ mixed-ratio increased, the less joule heating was. And the power consumptions by electron and positive ions increased with the increase of $N_2$ mixed-ratio.

SMA 선이 삽입된 복합재 보의 굽힘 및 비틀림 해석 (The Bending and Twisting Analysis of SMA/Composite Beams)

  • 박범식;김철
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.151-154
    • /
    • 2001
  • Shape memory alloy (SMA) has demonstrated its potentials for various smart structure applications. SMA wires undergo a reversible phase transformation from martensite to austenite as temperature increases. This transformation leads to shape recovery and associated recovery strains. If SMA actuators are embedded off the neutral surface and are oriented in arbitrary angles with respect to a beam axis, then the beam bends and twists due to the coupling effects of recovery strains activated. In this study, the bending and twisting of a SMA/Composite beam were controlled by both electric resistive heating and passive elastic tailoring. 3-dimensional finite element formulations were derived and validated to analyze the responses of the SMA/Composite beam. Numerical results show that the shape of the SMA/Composite beam can be controlled by judicious choices of control temperatures, SMA angles, and elastic tailoring.

  • PDF

유체 모델을 기반으로 하는 유도 결합 플라즈마 시뮬레이터 개발 현황 (The Present Status of Development of Inductively Coupled Plasma Simulator based on Fluid Model)

  • 권득철;윤남식
    • 한국진공학회지
    • /
    • 제18권3호
    • /
    • pp.151-163
    • /
    • 2009
  • 유체 모델을 기반으로 하는 국내의 유도 결합 플라즈마원의 시뮬레이터 개발 현황을 정리하였다. 전체 시뮬레이터를 구성하는 각 부분으로서, 전자 가열, 하전 입자 및 중성종 수송, sheath를 포함한 표면 반응, 그리고 GUI (Graphic User Interface) 및 전후처리기 등의 순으로 설명되었다. 현재까지 시뮬레이터에 구현된 화학 반응 데이터와 swarm 데이터도 정리하여 보았고, 앞으로의 개발 방향을 전망하여 보았다.

Thermo-mechanical damage of tungsten surfaces exposed to rapid transient plasma heat loads

  • Crosby, Tamer;Ghoniem, Nasr M.
    • Interaction and multiscale mechanics
    • /
    • 제4권3호
    • /
    • pp.207-217
    • /
    • 2011
  • International efforts have focused recently on the development of tungsten surfaces that can intercept energetic ionized and neutral atoms, and heat fluxes in the divertor region of magnetic fusion confinement devices. The combination of transient heating and local swelling due to implanted helium and hydrogen atoms has been experimentally shown to lead to severe surface and sub-surface damage. We present here a computational model to determine the relationship between the thermo-mechanical loading conditions, and the onset of damage and failure of tungsten surfaces. The model is based on thermo-elasticity, coupled with a grain boundary damage mode that includes contact cohesive elements for grain boundary sliding and fracture. This mechanics model is also coupled with a transient heat conduction model for temperature distributions following rapid thermal pulses. Results of the computational model are compared to experiments on tungsten bombarded with energetic helium and deuterium particle fluxes.

Numerical Simulation of Ion Beam Acoustic Instability by Single Ion Beams

  • Kim, S.Y.
    • Journal of Astronomy and Space Sciences
    • /
    • 제3권2호
    • /
    • pp.117-122
    • /
    • 1986
  • 최근에 지구 자기권의 magnetotail 부분에서 주파수 범위가 매우 넓은 정전기적 교란이 발견되었다. 이 불안정성은 이 지역에서 발견되는 이온층으로부터 날라오는 이온빔에 의하여 발생된다는 사실을 알고 있다. Magnetotail 속에서 얼어나는 이온빔 acoustic 불안정성의 컴퓨터 모의실험 결과를 제시한다. 이 불안정성으로 안하여 위성에 의하여 관측된 이온들의 heating이 얻어짐을 확인하였다.

  • PDF

THE VELOCITY FIELD OF SUPERNOVA-DRIVEN TURBULENCE IN THE INTERSTELLAR MEDIUM

  • KIM JONGSOO
    • 천문학회지
    • /
    • 제37권4호
    • /
    • pp.237-241
    • /
    • 2004
  • We perform numerical experiments on supernova-driven turbulent flows in order to see whether or not supernovae playa major role in driving turbulence in the interstellar medium. In a $(200pc)^3$ computational box, we set up, as initial conditions, uniformly magnetized gas distributions with different pairs of hydrogen number densities and magnetic field strengths, which cover the observed values in the Galactic midplane. We then explode supernovae at randomly chosen positions at a Galactic explosion rate and follow up the evolution of the supernova-driven turbulent flows by integrating numerically the ideal MHD equations with cooling and heating terms. From the numerical experiments we find that the density-weighted velocity dispersions of the flows are in the range of 5-10 km $s^{-l}$, which are consistent with the observed velocity dispersions of cold and warm neutral media. Additionally, we find that strong compressible flows driven by supernova explosions quickly change into solenoidal flows.

ECR 플라즈마를 이용한 실리콘화박막증착 (Silicon Nitride Thin Film Deposition Using ECR Plasma)

  • 송선규;장홍영
    • 한국표면공학회지
    • /
    • 제23권4호
    • /
    • pp.218-224
    • /
    • 1990
  • Silicon nitride thin(SiNx) is deposited onto 3 inch silicon wafor using ECR plasma apparatus. For the two different plasma extraction windows size, the thin films which were deposited by changing the SiH4/N2 gas fole at at 1.5mTorr without substrate heating are analyzed through the XPS and wlliposometer measurements. The very uniform and good quality silicon nitride thin film were obtained with the analyzed results of the deposited films, and particularly, ion temperature perpendicular to the magnetic filed was nearly same as the neutral gas temperature. The large amount of plasma loss in the transport process following magnetic field lines could be seen from the plasma emission intensity measurements.

  • PDF

제주지역 직장어린이집 보육실의 겨울철 실내온열환경 실태 (Winter Indoor Thermal Environment Status of Nursery Rooms in Workplace Daycare Centers in Jeju Island)

  • 김봉애;고연숙
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.81-90
    • /
    • 2017
  • This study was conducted to investigate the thermal environment status of nursery rooms in workplace daycare centers in Jeju and propose measures to improve their indoor physical thermal environment. For this purpose, measurements were performed in the winter indoor physical environment of 51 nursery rooms in 11 workplace daycare centers and a psychological evaluation survey on the thermal environment of nursery rooms was conducted for 70 nursery teachers. The investigation was carried out over 11 days in January 2017. The results are as follow. The average indoor temperature of the nursery rooms was $21.3^{\circ}C$($18.7-23.8^{\circ}C$) and the indoor temperatures of 47 nursery rooms (92.9%) were higher than the environmental hygiene management standard for domestic school facilities ($18-20^{\circ}C$). The average relative humidity was 33.9% (16.4-56.0%), and 37 nursery rooms (86.3%) showed a lower average relative humidity than the standard (40-70%). The average absolute humidity was $9.1g/m^3$ ($4.7-13.6g/m^3$), which was lower than the standard for preventing influenza ($10g/m^3$). When the indoor temperature and humidity of the nursery rooms were compared with international standards, it was found that 85% or more of the 51 nursery rooms maintained appropriate indoor temperatures, but 40-50% of the nursery rooms maintained a low humidity condition. Therefore, they need to pay attention to maintaining the appropriate humidity of the nursery room to keep the children healthy. The average indoor temperature of the nursery rooms showed a weak negative correlation with the average relative humidity. The indoor temperature had a significant effect on the relative humidity: a higher indoor temperature resulted in lower relative humidity. Regarding the fluctuations in the average indoor temperature of the nursery rooms during the day, in daycare centers that used floor heating, the indoor temperature gradually increased form the morning to the afternoon and tended to decrease during lunch time and the morning and afternoon snack times, due to ventilation. The daycare centers that used both floor heating and ceiling-type air conditioners showed a higher indoor temperature and greater fluctuations in temperature compared to the daycare centers that used floor heating only. In the survey results, the average value of the whole body thermal sensation was 3.0 (neutral): 32 respondents (62.7%) answered, "Neutral", Which was the largest number, followed by 21 respondents (30%) who answered, "Slightly hot" and 17 respondents (24.2%) who answered, "Slightly cold." Twenty-nine respondents answered, "Slightly dry," which was the largest number, followed by 28 respondents (54.9%) who answered, "Neutral" and 10 respondents (19.6%) who answered, "Dry." The total number of respondents who answered, "Slightly dry" or "Dry" was large at 39 (56.4%), which suggests the need for indoor environment management to prevent a low-humidity environment. To summarize the above results about the thermal environment of nursery rooms, as the indoor temperature increased, the relative humidity decreased. This suggests the effect of room temperature on the indoor relative humidity; however, frequent ventilations also greatly decrease the relative humidity. Therefore, the ventilation method and the usage of air conditioning systems need to be re-examined.