• Title/Summary/Keyword: network flow

Search Result 2,350, Processing Time 0.029 seconds

Real-time Phishing Site Detection Method (피싱사이트 실시간 탐지 기법)

  • Sa, Joon-Ho;Lee, Sang-Jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.4
    • /
    • pp.819-825
    • /
    • 2012
  • Nowadays many phishing sites contain HTTP links to victim web-site's contents such as images, bulletin board etc. to make the phishing sites look more real and similar to the victim web-site. We introduce a real-time phishing site detection system which makes use of the characteristic that the phishing sites' URLs flow into the victim web-site via the HTTP referer header field when the phishing site is visited. The detection system is designed to adopt an out-of-path network configuration to minimize effect on the running system, and a phishing site source code analysis technique to alert administrators in real-time when phishing site is detected. The detection system was installed on a company's web-site which had been targeted for phishing. As result, the detection system detected 40 phishing sites in 6 days of test period.

Level of Service Evaluation of Pedestrian Road Using Micro-Simulation (미시적 교통 시뮬레이션을 활용한 보행자도로 서비스 수준 평가)

  • Park, Soon Yong;Cho, Hyerim;Cho, Ga Young;Yun, Ilsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.26-36
    • /
    • 2020
  • The use of existing macroscopic research of pedestrian behavior on the walking link as data is limited in determining an individual pedestrian's moving route and the level of service. In macroscopic studies, it is difficult to make quantitative indices, such as pedestrian flow rate, occupied space, density, and speed for determining the level of service on pedestrian roads. Therefore, the microscopic pedestrian route is required to establish appropriate pedestrian policies. In this study, the Yeok-Sam subway station network was examined using a micro-simulation VISSIM, which was then calibrated and validated statistically. The Pedestrian Road's Level of Service of Yeok-Sam subway station area was evaluated using the pedestrian speed as the evaluating index on the Korean highway capacity handbook.

Analysis of Driving Characteristics of Elderly Drivers on Roads Using Vehicle Simulator (차량 시뮬레이터를 이용한 연속류 도로의 고령운전자 주행특성 분석)

  • LEE, GEUN-HEE;BAE, GI-MOK
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.1
    • /
    • pp.146-159
    • /
    • 2021
  • vehicle simulator as part of an empirical analysis the driving characteristics of elderly drivers. To this end, the driving characteristics of the elderly driver from previous study review. he driving characteristics of the elderly the driving elderly driver and general driverIn summarizing these experimental results, the -test showed different driving characteristics from general drivers in all items except for one side of the lane, such as driving speed and driving operation (brake, throttle, steering operation) at a significance level of 95%. Second, when changing lanes, it was difficult for elderly driver to maintain speed and secure an appropriate distance between carslderly driver changed lanes even in inappropriate situations (short distances between cars). Third, in unexpected situation, elderly drivers needed more distance and time.

An Analysis of Changes in Perception of Metaverse through Big Data - Comparing Before and After COVID-19 - (빅데이터 분석을 통한 메타버스에 대한 인식 변화 분석 - 코로나19 발생 전후 비교를 중심으로 -)

  • Kang, Yu Rim;Kim, Mun Young
    • Fashion & Textile Research Journal
    • /
    • v.24 no.5
    • /
    • pp.593-604
    • /
    • 2022
  • The purpose of this study is to analyze the flow of change in perception of metaverse before and after COVID-19 through big data analysis. This research method used Textom to collect all data, including metaverse for two years before COVID-19 (2018.1.1~2019.11.30) and after COVID-19 outbreak (2020.1.11~2021.12.31), and the collection channels were selected by Naver and Google. The collected data were text mining, and word frequency, TF-IDF, word cloud, network analysis, and emotional analysis were conducted. As a result of the analysis, first, hotels, weddings, and glades were commonly extracted as social issues related to metaverse before and after COVID-19, and keywords such as robots and launches were derived, so the frequency of keywords related to hotels and weddings was high. Second, the association of the pre-COVID-19 metaverse keywords was platform-oriented, content-oriented, economic-oriented, and online promotion-oriented, and post-COVID-19 clusters were event-oriented, ontact sales-oriented, stock-oriented, and new businesses. Third, positive keywords such as likes, interest, and joy before COVID-19 were high, and positive keywords such as likes, joy, and interest after COVID-19. In conclusion, through this study, it was found that metaverse has firmly established itself as a new platform business model that can be used in various fields such as tourism, travel, festivals, and education using smart technology and metaverse.

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen;Sun, Kaichao;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3879-3891
    • /
    • 2021
  • A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.

Research on Backup Protective Coordination for Distribution Network (네트워크 배전계통용 백업 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Kim, JuYong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.15-19
    • /
    • 2022
  • The radial distribution systems (RDS) commonly used around the world has the following disadvantages. First, when the DL is operated on a radial system, the line utilization rate is usually kept low. Second, if a fault occurs in the radial DL, a power outage of 3 to 5 minutes is occurring depending on the operator's proficiency and fault situation until the fault section is separated and the normal section is replaced. To solve this problem, Various methods have been proposed at domestic and foreign to solve this problem, and in Korea, research is underway on the advanced system of operating multiple linked DL always. A system that is electrically linked always, and that is built to enable high-speed communication during the protection coordination is named networked distribution system (NDS). Because the load shares the DL, the line utilization rate can be improved, and even if the line faults, the normal section does not need to be cut off, so the normal section does not experience a power outage. However, since it is impossible to predict in which direction the fault current will flow when a failure occurs in the NDS, a communication-based protection coordination is used, but there is no backup protection coordination method in case of communication failure. Therefore, in this paper, we propose a protective cooperation method to apply as a backup method when communication fails in NDS. The new method is to change TCC by location of CB using voltage drop in case of fault.

A study of communication-based protection coordination for networked distribution system (네트워크 배전계통용 통신기반 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Lee, HakJu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2022
  • Although the distribution system has been structured as complicated as a mesh in the past, the connection points for each line are always kept open, so that it is operated as a radial distribution system (RDS). For RDS, the line utilization rate is determined according to the maximum load on the line, and the utilization rate is usually kept low. In addition, when a fault occurs in the RDS, a power outage of about 3 to 5 minutes occurs until the fault section is separated, and the healthy section is transferred to another line. To improve the disadvantages of the RDS, research on the construction of a networked distribution system (NDS) that linking multiple lines is in progress. Compared to the RDS, the NDS has advantages such as increased facility utilization, load leveling, self-healing, increased capacity connected to distributed generator, and resolution of terminal voltage drop. However, when a fault occurs in the network distribution system, fault current can flow in from all connected lines, and the direction of fault current varies depending on the fault point, so a high-precision fault current direction determination method and high-speed communication are required. Therefore, in this paper, we propose an accurate fault current direction determination method by comparing the peak value polarity of the fault current in the event of a fault, and a communication-based protection coordination method using this method.

Analysis of Agenda-setting Changes in Alpine Agricultural of Uljin-gun Using Text-Mining - Focusing on the Keywords of Mass-media, Blog·Cafe - (텍스트마이닝 기법을 활용한 울진군 금강송 산지농업 의제설정 변화 - 매스미디어와 블로그·카페 키워드를 중심으로 -)

  • Do, Jee-Yoon;Jeong, Myeong-Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.3
    • /
    • pp.47-57
    • /
    • 2022
  • This study attempted to grasp the status and perception of Uljin Geumgangsong by grasping mass media issues and user perception using big data, and to present basic data when constructing monitoring using user perception by examining the establishment relationship of agenda setting from a time-series perspective. The results of collecting and analyzing text data that can identify mass media and visitor awareness are as follows. First, both mass media and visitor keywords were related to the importance of the value and meaning of Uljin Geumgangsong. Second, in the case of the connection network, Geumgang Pine Agriculture was centered, but in the case of difference in perception between mass media and visitors, such results were derived due to the object of interest. Third, in the case of the connection relationship structure, the connection strength was strong because there were many overlapping contents of mass media. Fourth, as a result of the centrality analysis, both mass media and visitor-aware keywords were positively recognized as spaces created and maintained through institutional support, and objective perception could be grasped by finding hidden keywords. Fifth, as a result of time series analysis, it was possible to grasp the flow through the issue keywords that appeared by period, and unlike the past, it was recognized as a place for tourism and travel. Finally, as a result of examining whether the agenda setting is consistent, there is a mass media influence, so it is thought that more diverse and more information and publicity are needed by utilizing it.

A Study on Determination of Optimal Reclosing Guideline on Distribution Lines (배전선로 재폐로 최적 기준 산정에 관한 연구)

  • Cho, Jae-Hun;Lee, Sun-Jung;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.417-422
    • /
    • 2022
  • It is always desirable that the continuation of power flow through the lines should not be interrupted for a long time. The optimized guideline of reclosers on distribution lines is known to improve the reliability of power systems, the protection functions on distribution systems heavily rely on the number and placement of such reclosers. This study reviewed the effect of using protection settings methodology with the number of reclosing operations to reduce the damage sustained during faults on distribution networks. The aim of the study is to determine the number of reclosing operations and fault current conditions based on simulation data of PSCAD/EMTDC for standard distribution networks. It is found that the determination of the number of operations on reclosers, which are the protection function of feeders, helped to optimize the operation and reliability of distribution networks.

Integrating Resilient Tier N+1 Networks with Distributed Non-Recursive Cloud Model for Cyber-Physical Applications

  • Okafor, Kennedy Chinedu;Longe, Omowunmi Mary
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2257-2285
    • /
    • 2022
  • Cyber-physical systems (CPS) have been growing exponentially due to improved cloud-datacenter infrastructure-as-a-service (CDIaaS). Incremental expandability (scalability), Quality of Service (QoS) performance, and reliability are currently the automation focus on healthy Tier 4 CDIaaS. However, stable QoS is yet to be fully addressed in Cyber-physical data centers (CP-DCS). Also, balanced agility and flexibility for the application workloads need urgent attention. There is a need for a resilient and fault-tolerance scheme in terms of CPS routing service including Pod cluster reliability analytics that meets QoS requirements. Motivated by these concerns, our contributions are fourfold. First, a Distributed Non-Recursive Cloud Model (DNRCM) is proposed to support cyber-physical workloads for remote lab activities. Second, an efficient QoS stability model with Routh-Hurwitz criteria is established. Third, an evaluation of the CDIaaS DCN topology is validated for handling large-scale, traffic workloads. Network Function Virtualization (NFV) with Floodlight SDN controllers was adopted for the implementation of DNRCM with embedded rule-base in Open vSwitch engines. Fourth, QoS evaluation is carried out experimentally. Considering the non-recursive queuing delays with SDN isolation (logical), a lower queuing delay (19.65%) is observed. Without logical isolation, the average queuing delay is 80.34%. Without logical resource isolation, the fault tolerance yields 33.55%, while with logical isolation, it yields 66.44%. In terms of throughput, DNRCM, recursive BCube, and DCell offered 38.30%, 36.37%, and 25.53% respectively. Similarly, the DNRCM had an improved incremental scalability profile of 40.00%, while BCube and Recursive DCell had 33.33%, and 26.67% respectively. In terms of service availability, the DNRCM offered 52.10% compared with recursive BCube and DCell which yielded 34.72% and 13.18% respectively. The average delays obtained for DNRCM, recursive BCube, and DCell are 32.81%, 33.44%, and 33.75% respectively. Finally, workload utilization for DNRCM, recursive BCube, and DCell yielded 50.28%, 27.93%, and 21.79% respectively.