• Title/Summary/Keyword: needle technique

검색결과 302건 처리시간 0.029초

약침용 불량 Needle의 미세 형태 관찰 (Observation of Fine Structures of Defective Herbal Acupuncture Needles)

  • 박원필;김현도;권기록
    • 대한약침학회지
    • /
    • 제8권1호
    • /
    • pp.67-71
    • /
    • 2005
  • Objectives : This study was conducted to observe the tip of needles which induce poor needle sensation upon injection of herbal acupuncture. Methods : Among the syringes used for herbal acupuncture, needles which cause poor sensation were collected and evaluated by SEM (scanning electron microscope) for changes in structure, existence of impure matters, physical damage, and etc. Results : 1. Various forms contributed to poor needle sensation. Bent needle body, damaged or crooked needle tip, and blunted tip 2. Poor needles could be made during the manufacturing process, during insertion of the needle into the vial(except for the lubricants), and repeated procedures with one needle at different regions. Conclusion : Poor needles induce unnecessary pain and discomfort not only to the patients but also to administrators during injection. Herbal acupuncture is a treatment technique injecting herbal extract on the meridian points, and strict quality check must be enforced to prevent occurrence of poor needles.

Y needle을 이용한 간단한 이중검 수술 (SIMPLE DOUBLE EYELID OPERATION (ORIENTAL BLEPHAROPLASTY) USING Y NEEDLE)

  • 양병은;김성곤;김용관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권2호
    • /
    • pp.157-161
    • /
    • 2004
  • 본 방법을 통해 수술할 경우 몇 가지 장점이 있다. Y needle의 경우 5mm간격으로 고안되어 있어 3부위에서 일정량의 조직결찰이 가능하고 고안에 따라 여러 가지 간격으로 만들어 질 수 있어 환자의 상태에 따라 적용가능하다. 또한 피부부위에서 결막으로 들어가는 부위가 수직이어서 원하는바 정확한 이중검 위치를 만들어 줄 수 있다. 초심자가 시행하더라도 관통부위를 eyelash 경계와 비교적 평행하게 만들어 줄 수 있다. Needle의 삽입이 2개가 한꺼번에 삽입되므로 환자가 느끼는 통증이 감소되며 술자의 편의도도 증가하리라 생각된다. 부분절개법을 사용하여 잉여지방 및 조직을 제거하였고 매몰하여 흉터와 부작용을 최소화하였고 회복기간과 수술시간을 감소시킬 수 있었다. 본 방법은 모든 경우의 이중검수술에 이용될 수는 없겠으나 고찰에서 기술한 비절개식이나 부분절개식 이중검수술의 적응증에 해당되는 경우에 이용할 경우 아주 간단하고 임상적으로 표준화 될수 있는 방법으로 응용될 수 있을 것으로 사료되어 문헌고찰과 함께 보고하는 바이다.

천미골 접합부를 이용한 외톨이 신경절 차단법 (Modified Approach through the Sacrococcygeal Junction to Block the Ganglion Impar)

  • 송선옥;권오득;김성기
    • The Korean Journal of Pain
    • /
    • 제10권2호
    • /
    • pp.254-257
    • /
    • 1997
  • Ganglion impar lies immediately anterior to the sacrococcygeal junction and blockade of the ganglion is used to treat anorectal and perineal pain. Although the technique introduced by Plancarte et at is widely practised, the bent needle is sometimes difficult to position precisely and patients find the procedure painful. We modified this approach of block of ganglion impar by positioning the needle into the sacrococcygeal junction and using the loss of resistance technique. With the patient in the lateral position, a skin wheal was raised at 1-1.5cm below the sacral hiatus. Twenty-three gauge short needle was directly placed into the sacrococcygeal junction with aid of fluoroscopic guidance. From 1 cm behind the anterior margin of the vertebral body in lateral view, we used the loss of resistance technique to confirm the retroperitoneal space. We found this modified approach easier to perform during six blocks for three patients with anorectal or perineal pain. Our modified approach through the sacrococcygeal junction may provide opportunity for wider administration of this procedure because of its simple technique, reduced pain during procedure and decreased risk of infection.

  • PDF

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

  • El Hajj, Ihab I.;Wu, Howard;Reuss, Sarah;Randolph, Melissa;Harris, Akeem;Gromski, Mark A.;Al-Haddad, Mohammad
    • Clinical Endoscopy
    • /
    • 제51권6호
    • /
    • pp.576-583
    • /
    • 2018
  • Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissue acquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguided sampling of solid lesions and compare it with the historical FNA technique. Methods: $Acquire^{(R)}$ 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtained using $Expect^{(R)}$ 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independently evaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantly lower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNA groups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNB group. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to those obtained by FNA, but with fewer passes.

애주 무게별 온침의 침체간부 온도 변화 특성 연구 (A Characteristics on Temperature Change of Warm Needle's Body Depended on Moxa-Corn Weights)

  • 안성훈;홍덕;권오상;김유리;김재효;손인철
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.71-78
    • /
    • 2010
  • Objectives : The warm needling technique is a combination of acupuncture and moxibustion. The purpose of this study was to find the physical and thermal characteristics in order to identify the effects and mechanisms of the warm needling technique. Methods : In this study, the thermal changes were observed with a testo 845 device, which is an infra-red thermometer specifically designed for measuring a combustion of corn shaped moxibustion(moxa-corn). The thermal changes at the apex of the moxa-corn placed on the top of the an acupuncture were observed at the level of 1 cm and 2 cm from the apex to understand heat conduction through acupuncture needle for combustion of moxa-corn. Results and Conclusions : The thermal conduction through acupuncture needle from the moxa-corn was relative to the weight of moxa-corn and was inversely relative to the distance of the moxa-corn and acupuncture needle length. And the value of thermal conduction to the apex of the acupuncture needle from the moxa-corn was about $3{\sim}5^{\circ}C$. The above results suggest that the present study may be useful in finding the mechanism and effects of the warming needling technique.

한조절(汗調節) 혈위(穴位) 합곡(合谷) 복류(復溜)의 보사(補瀉)에 따른 침자(鍼刺)가 지한(止汗)에 미치는 영향(影響) (The effect of acupuncture using tonification and sedation manipulation at LI4(Hegu) and KI7(Fuliu) on the control of sweating)

  • 송민선;최찬헌;윤대환;김지현;나창수
    • Korean Journal of Acupuncture
    • /
    • 제25권4호
    • /
    • pp.133-145
    • /
    • 2008
  • Objectives : The purpose of this study was to exam the effectiveness of acupuncture using the tonification & sedation manipulation for LI4(Hegu) and KI7(Fuliu) which was known to promote sweating for lack sweating and inhibit for excessive sweating. Methods : The subject of this study was 60 people who agreed with participating. The participants were divided into 6 groups as control group without acupuncture, acupuncture group with needle inserted perpendicularly at LI4, KI7 without manipulation(AT-A), acupuncture group with needle inserted and twisted at LI4 using sedation technique and KI7 using tonificaton technique(AT-B), acupuncture group with needle inserted and twisted at LI4 using tonificaton technique and KI7 using sedation technique(AT-C), acupuncture group with needle inserted and twisted at LI4 and KI7 using tonificaton technique(AT-D) and acupuncture group with needle inserted and twisted at LI4 and KI7 using sedation technique(AT-E). We obtained baseline data at a stable condition with the temperature of $25^{\circ}C$. After having the participant stay at $40^{\circ}C$ for 10 minute and treated with acupuncture for 10 minute, we measured the parameters such as sweating rate, water content in subcutaneous, water content in skin surface, systolic blood pressure, diastolic blood pressure, pulse rate, oxygen saturation and body temperature. Results : After the tonification & sedation manipulation at LI4 and KI7, the sweating rate was significantly decreased in AT-B, AT-D and AT-E groups. The water contents in skin surface was significantly decreased in AT-B and AT-E groups. The water contents in subcutaneous was significantly decreased in AT-B, AT-C, AT-D and AT-E groups. However, there were no significant changes in systolic blood pressure, diastolic blood pressure, pulse rate, oxygen saturation and body temperature. Conclusions : Acupuncture at LI4 and KI7 is effective in controling sweating, and the effect varies according to the tonification & sedation manipulation technique.

  • PDF

십이지장 궤양으로 발현된 전이성 간세포암종 1예 (A Case of Hepatoma with Duodenal Metastasis Proved by Liver Aspiration Cytology and Gastrofiberscopic Duodenal Biopsy)

  • 김성진;박석건;한동선;김성숙
    • 대한세포병리학회지
    • /
    • 제2권2호
    • /
    • pp.105-110
    • /
    • 1991
  • We report a case of hepatoma with duodenal metastasis in a 53 year-old male patient. Hepatoma was confirmed by fine needle aspiration cytology technique, and duodenal metastasis by gastrofiberscopic biopsy. Duodenal metastasis of hepatoma is rare. We briefly review the role of fine needle aspiration cytology technique in diagnosis of hepatoma.

  • PDF

Unilateral, Single Needle Approach Using an Epidural Catheter for Bilateral Superior Hypogastric Plexus Block

  • Baik, Ji-Seok;Choi, Eun-Joo;Lee, Pyung-Bok;Nahm, Francis Sahn-Gun
    • The Korean Journal of Pain
    • /
    • 제25권1호
    • /
    • pp.43-46
    • /
    • 2012
  • The superior hypogastric plexus block (SHPB) is used for treating pelvic pain, especially in patients with gynecological malignancies. Various approaches to this procedure have been reported due to the anatomic obstacles of a high iliac crest or large transverse process of the $5^{th}$ lumbar vertebra. Here, we report a new technique of superior hypogastric plexus block using a unilateral single-needle approach to block the bilateral superior hypogastric plexus with a Tuohy needle and epidural catheter. We have confidence that this new technique can be another option in performing the SHPB when the conventional bilateral approach is difficult to perform.

NaOH 수용액을 이용한 전기화학적 방전가공법에 의한 유리기판의 미세가공 (Microdrilling of Glass Substrates by Electrochemical Discharge Machining in NaOH Solution)

  • 홍석우;정귀상;최영규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.427-430
    • /
    • 1998
  • Electro Discharge Machining (EDM) is a so-call non-conventional machining technique. This paper presents the experimental results of an EDM technique for the fabrication of microholes on #7440 pyrex glass substrates. With various applied voltages and at various concentration of NaOH solution, the glass substrates have been microdrilled using the copper electrodes of which diameters are 250 $\mu\textrm{m}$ to 450 $\mu\textrm{m}$. The machined throughholes have been observed the top diameter, the bottom diameter and machining time have been measured. The experimental results show that the machining time decreases as the concentration of NaOH solution increases, the applied voltage increases and the needle diameter decreases. Also, the top diameter increases as the needle diameter increases or the applied voltage increases. The bottom diameter decreases as the needle diameter decreases or the applied voltage decreases.

  • PDF

점성 유체중에 자유낙하 하는 니들과 스프링의 거동에 관한 연구 (STUDY ON THE BEHAVIOR OF NEEDLES AND SPRINGS FALLING FREELY IN A VISCOUS FLUID)

  • 고담;서용권
    • 한국전산유체공학회지
    • /
    • 제19권2호
    • /
    • pp.30-39
    • /
    • 2014
  • We report in this paper the analysis of the motion of a needle and a spring in a viscous fluid under the influence of gravitational force. Lateral shift as well as vertical motion of a needle falling in a viscous fluid has been observed from a simple experiment. We also observed the combined rotation and translation of a falling spring. The trajectory and velocity of the falling needle and the spring were obtained by using an image processing technique. We also conducted numerical simulation for both problems. For the falling-needle problem, we employed a theory; but it turns out that significant correction is required for the solutions to match the numerical and experimental data. For the falling spring problem various theoretical formula were tested for their justification, but none of the existing theories can successfully predict the numerical and experimental results.