• Title/Summary/Keyword: needle electrode

Search Result 252, Processing Time 0.029 seconds

Effect of Radius of Curvature of a Corona Needle on Ionic Wind Generation (방전 침전극의 곡률반경이 이온풍 발생에 미치는 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.604-608
    • /
    • 2010
  • An electric fan for cooling high density electronic devices is limited and operated in very low efficiency. The corona discharge is utilized as the driving mechanism for an ionic gas pump, which allows for air flow control and generation with low noise and no moving parts. These ideal characteristics of ionic pump give rise to variety applications. However, all of these applications would benefit from maximizing the flow velocities and yields of the ionic pump. In this study, a needle-mesh type ionic pump has been investigated by focusing on the radius of curvature of corona needle points elevating the ionic wind velocity and efficiency. It is found that the radius of curvature of the corona discharge needle point influences significantly to produce the ionic wind and efficiency. As a result, an elevated ionic wind velocity and increased ionic wind generation yield can be obtained by optimized the radius of curvature of the corona needle electrode.

A Study on the Effects of Needle Electrode Electrical Stimulation on the Number of c-Fos Response Cells and c-Fos Expression in the Global Ischemic Rats

  • Kim, Sung Won;Song, Young Wha;Lee, Jung Sook
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1031-1036
    • /
    • 2016
  • c-Fos is known to related to synaptic plasticity and apoptosis in damage from ischemia or external injury. The purpose of this study was to investigate whether needle electrode electrical stimulation(NEES) is effective in increasing the number of c-Fos response cells and c-Fos expression in striatum after global ischemia in rats. There were no treatment and occlusion in the control group, global ischemia(GI) group were no treatment after carotid artery occlusion, and needle electrode electrical stimulation(NEES) group were treated with NEES after GI induced. The number of striatum c-Fos response cells and c-Fos protein expression significantly decreased in the NEES group compared to the GI group after 12, 24, 48 hours. The results of the present study suggest that NEES is ineffective in improving global ischemia in rats and may also be ineffective in the globally ischemic human brain.

Effects of Pressure and Temperature of Airflow on Performance of Nozzle-type Electrostatic Eliminator

  • CHOI Kwang-Seok;MOGAMI Tomofumi;SUZUKI Teruo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.228-232
    • /
    • 2005
  • The effects of the pressure and temperature of airflow were experimentally investigated to improve the performance of a nozzle-type electrostatic eliminator. The pressure ($A_P$) and the temperature ($A_T$) of the airflow toward the needle electrode were controlled in the ranges of 0 Mpa to 0.3 Mpa and of $25^{\circ}C$ to $125^{\circ}C$, respectively. It was confirmed that the ion-generation ability was increased depending on the magnitude of the $A_P$ and the $A_T$ of the airflow provided to the surrounding region of the needle electrode in the nozzle-type electrostatic eliminator. In addition, it was clear that the mixed effect of the $A_P$ and the $A_T$ of the airflow was large. These results were attributed mainly to (1) the activation of the corona discharge by the $A_T$, (2) the change of the decomposition and production of a suppression gas by the $A_T$, (3) the blow-off of the suppression gas near the needle electrode by the $A_P$, and (4) the change of the distribution of the current densities on the needle electrode by the $A_P$.

Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation (장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

The Effect of Needle Electrode Electrical Stimulation on the Change of Caspase-3, 9 and Neuronal Nitric Oxide Synthase Immunoreactive Cells in the Sprague Dawley Rats (침전극 저주파자극이 흰쥐의 Caspase-3, 9와 Neuronal Nitric Oxide Synthase 면역반응세포 변화에 미치는 영향)

  • Kim, Soo-Han;Choi, Houng-Sik;Kim, Tack-Hoon;Cynn, Heon-Seock;Kim, Ji-Sung;Song, Chi-Won
    • Physical Therapy Korea
    • /
    • v.11 no.2
    • /
    • pp.47-63
    • /
    • 2004
  • In most tissues, apoptosis plays a pivotal role in normal development and in regulation of cell number. Therefore inappropriate apoptosis is revealed in a variety of diseases. This study was carried out to investigate the effects of acupuncture and needle electrode electrical stimulation on the change of caspase-3, 9 and neuronal nitric oxide synthase (nNOS) immunoreactive cells in the sprague dawley rats (SD rat). In immobilized SD rats (n=5), enhanced caspase-3 and caspase-9 expression were detected in the reticular part of substantia nigra, and enhanced nNOS was detected in the dorsolateral periaqueductal gray (DL-PAG) of midbrain and the paraventricular nucleus (PVN) of the hypothalamus using immunohistochemistry. Following the immobilization, acupuncture (n=5) and needle electrode electrical stimulation (n=5, 2 Hz) was applied at H$\acute{e}$g$\breve{u}$ (LI4) acupoint of SD rats, respectively. The stress-induced enhancement in the expression of caspase-3, 9 and nNOS were The present results demonstrate that and needle electrode electrical stimulation are effective in the modulation of expression of caspase-3, 9 and nNOS induced by immobilization.

  • PDF

Experiment on the Polish Condition of Needle Electrode on the Insulation Properties of Gas Mixtures (침전극 가공상태에 따른 혼합가스의 절연특성에 관한 실험)

  • Go, Yeon-Seong;Yeo, Dong-Goo;Seo, Ho-Joon;Lee, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.339-340
    • /
    • 2006
  • AC spark discharge voltage of SF6/CO2and SF6/N2 containing various mixed rate in volume percent (1, 5 and 10%) of SF6 in non-uniform fields are investigated. The needle to plane electrode gap spacing was 5 and 10 mm, and the gas pressure was varied within the range of 0.1~0.7 MPa. We have observed a N-characteristic typical for the electronegative gases even in gas mixtures of 1% SF6 with CO2 and N2 as buffer gases. Especially, the materials of the needle electrode affect the insulation properties of the gas mixtures drastically. On the contrary to the case of needle electrodes made by mild steel or high carbon steel, the N-characteristics are hardly perceived in the case of stainless steel needle in this experiment.

  • PDF

Manufacturing of Micro-needle Using Micro-EDM Process (마이크로 EDM공정을 이용한 마이크로 바늘의 제조)

  • Lee, Choon-Mee;Kwon, Won Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.285-291
    • /
    • 2017
  • Micro-needles are used as transferring devices for sampling of tiny constitute substances from biological bodies. Typically, nickel is used as a coating to improve the rigidity of micro-needles. This study introduces the methodology to manufacture a WC needle with very high hardness and toughness. Micro-EDM technology was used to manufacture micro-needles with holes $130{\mu}m$ in diameter and $2300{\mu}m$ in length. A micro-needle was aligned to the micro-EDM electrode using a custom two degree-of-freedom alignment system. A three-step manufacturing technique was developed to drill a micro-hole using a WC electrode. In the first process, an electrode $105{\mu}m$ in diameter was used to make a hole. Electrodes of 90 and $105{\mu}m$ diameters were used in the second and third process, respectively. Consequently, a WC micro-needle with an inner hole of $135{\mu}m$ diameter, length of $2300{\mu}m$, and outer diameter of $300{\mu}m$ was developed.

Discharge Characteristics of SF6 Mixture Gases due to Processing Status of needle electrode under Non-Uniform Fields (불평등 전계 하에서의 침전극 가공상태에 따른 SF6혼합가스의 방전특성)

  • Go, Y.S.;Seo, H.J.;Rhie, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.198-199
    • /
    • 2006
  • AC spark discharge voltage of SF6/C02and SF6/N2 containing various mixed rate in volume percent (1, 5 and 10%) of SF6 in non-uniform fields are investigated. The needle to plane electrode gap spacing was 5 and 10 mm, and the gas pressure was varied within the range of 0.1${\sim}$0.7 MPa. We have observed a N-characteristic typical for the electronegative gases even in gas mixtures of 1% SF6 with CO2 and N2 as buffer gases. Especially, the materials of the needle electrode affect the insulation properties of the gas mixtures drastically. On the contrary to the case of needle electrodes made by mild steel or high carbon steel, the N-characteristics are hardly perceived in the case of stainless steel needle in this experiment.

  • PDF

Study of Laryngeal Evoked Electromyography Method in Rats (백서를 이용한 후두 유발 근전도 검사 방법에 대한 연구)

  • 조선희;이재연;민선식;신유리;정성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.2
    • /
    • pp.178-184
    • /
    • 2000
  • Laryngeal evoked EMG is the objective and quantitative method to measure the innervation of laryngeal muscle. If there is a mobility disorder of vocal cords, the cause and location of neural lesion co be understood by the laryngeal evoked EMG and if there is a vocal cord paralysis, the degree of recovery and the policy of treatment can be determined by it. Recently, the studies of reinnervation after recurrent laryngeal nerve injury have been actively carried out. Laryngeal evoked EMC is useful to these studies. The aim of study is to know whether noninvasive methods for stimulating the recurrent laryngeal nerve and for recording of compound action potential(CAP) using surface electrode are as useful as the invasive method using needle electrode. We obtained EMG of laryngeal muscle by various stimulating and recording methods : 1) Direct nerve stimulation by placing nerve cuff electrode made out of silastic tube and platinum wire and recording by insertion of hook wire electrode into posterior cricoarytenoid(PCA) and thyroarytenoid(TA) muscles, respectively. 2) Recording of compound action potential by surface electrode after stimulation of recurrent laryngeal nerve by the insertion of 27 gauge of needle electrode. 3) Recording of compound action potential by surface electrode after stimulating the recurrent laryngeal nerve by transcutaneous blunt rod electrode at tracheoesophageal groove. The amplitude, duration and latency of the CAP evoked by recurrent laryngeal nerve stimulation were compared among the three groups. The amplitude of CAP was smallest in the group recorded from posterior cricoarytenoid and hyroarytenoid muscle, and that recorded by surface electrode after stimulation by needle electrode was largest. The difference in amplitude between the group by hook wire recording and the two groups by surface electrode recording was significant statistically. There is no significant difference in duration and latency among three groups. Since the waveform of CAP from all three methods has similar duration, latency, we concluded that noninvasive method is a useful as invasive methods.

  • PDF

Contemporary Application of Roller Needle and Stamp Needle: A Patent Review (국내 특허 분석을 통한 롤러침 및 도장침의 현대적 활용)

  • Jeong, Seung-Yeon;Park, Ji-Yeun;Kim, Youn-Sub;Kim, Song-Yi
    • Korean Journal of Acupuncture
    • /
    • v.36 no.3
    • /
    • pp.139-149
    • /
    • 2019
  • Objectives : A dermal needle is one of the therapeutic method by stimulating or tapping on the certain points of skin. Recently, roller or stamp-needle have been applied to various diseases in combination with microneedle technology. In this study, we analyzed the trend of roller and stamp-needle in Korean patent. Methods : Electronic search for Korean patent of roller or stamp needle was performed in Korea Intellectual Property Right Information Service database to April, 2019. Results : Sixty seven patents (51, roller-needle; 15, stamp-needle; 1, both types of needle) met the inclusion criteria. According to patent details, 34 of 67 patents were skin stimulation, 14 patents were intended to increase the efficiency of drug delivery through skin stimulation, 16 patents combined skin stimulation with technologies such as electrode or high frequency, and three patents applied both electrode or high frequency stimulation, and drug application as well as physical skin stimulation. Each of these patents aims to increase the efficiency of the needle manufacturing process (n=24), to facilitate the use of tools or to increase the efficiency of the technology (n=61), or to increase the technical skill of the needle itself (n=23). Conclusions : This study confirms that technological advances were being made by combining various types of stimuli to dermal needle and there have been attempts to expand the scope of drug delivery in terms of application of dermal needle. In the future, more research and development is needed in order to apply the dermal needle to modern technology.