• Title/Summary/Keyword: near-fault

Search Result 358, Processing Time 0.029 seconds

Coulomb stress transfer due to reverse faulting displacement field (역단층성 변위에 의한 Coulomb stress transfer)

  • Ko, Min-Suk;Chang, Chan-Dong;Lee, Jun-Bok;Shim, Taek-Mo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.149-154
    • /
    • 2008
  • We analyzed the Coulomb stress transfer near a small-scale reverse fault. For the modeling we used the geometry of a Quaternary fault in Gyeongju area, Eupcheon fault. For an assumed reverse faulting slip of 10cm, the resulting values of the Coulomb stress change are relatively higher (>2 bar) near the edges (both downward and lateral) of the fault, and diminish slightly upward and downward. The equivalents are negative in the zone immediately below and above the fault, exhibiting a "T" shape of low stress zone in the vertical profile of the fault. This study demonstrates the possible ranges and directions the aftershock energy would propagates after a reverse faulting.

  • PDF

Studies on Mineral Composition of Fault Clay in Quaternary Ipsil Fault: High Resolution Powder Diffraction Analysis (제4기 입실 단층 파쇄대에서 나타나는 단층점토의 산출상태에 따른 광물조성 연구: 고해상도분말회절 분석을 중심으로)

  • Park, Sung-Min;Kang, Han;Jang, Yun-Deuk;Im, Chang-Bock;Kim, Jeong-Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.2 s.52
    • /
    • pp.83-89
    • /
    • 2007
  • XRD, HRPD and SEM were used for mineralogical characterization of fault clay in fracture zone from Ipsil. Variations of color in fault clay exhibit significant mineral composition difference. Fault clays from Ipsil are composed mainly of smectite, laumontite, and quartz. Laumontite, a distinct fault clay in Ipsil fault, might be resulted from alteration of bed rock in fracture zone based on the result that no laumontite was found near fault rock. Fault clays from Ipsil are composed mainly of smectite.

Implications of bi-directional interaction on seismic fragilities of structures

  • Pramanik, Debdulal;Banerjee, Abhik Kumar;Roy, Rana
    • Coupled systems mechanics
    • /
    • v.5 no.2
    • /
    • pp.101-126
    • /
    • 2016
  • Seismic structural fragility constitutes an important step for performance based seismic design. Lateral load-resisting structural members are often analyzed under one component base excitation, while the effect of bi-directional shaking is accounted per simplified rules. Fragility curves are constructed herein under real bi-directional excitation by a simple extension of the conventional Incremental Dynamic Analysis (IDA) under uni-directional shaking. Simple SODF systems, parametrically adjusted to different periods, are examined under a set of near-fault and far-fault excitations. Consideration of bi-directional interaction appears important for stiff systems. Further, the study indicates that the peak ground accelertaion, velocity and displacement (PGA, PGV and PGD) of accelerogram are relatively stable and efficient intensity measures for short, medium and long period systems respectively. '30%' combination rule seems to reasonably predict the fragility under bi-directional shaking at least for first mode dominated systems dealt herein up to a limit state of damage control.

A Phase-to-Phase Distance Relaying Algorithm Using Direct 3 Phase Calculation (직접계산을 이용한 상간단락 거리계전 알고리즘)

  • Hyun, Seung-Ho;Lee, Sung-O
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.333_335
    • /
    • 2009
  • It is expected, in the near future, that the use of distributed generation systems should be increased considerably. In this case, distance relay algorithm should be developed in the manner that it can reduce the error due to the in-feed effect. This paper presents a method to consider the fault current rushed from the remote end of a line. In the steady-state, the relays in both ends exchange the voltages of upper nodes. If a fault is perceived, the relay calculates fault location taking the fault current from the remote end by using voltage data of the remote ends obtained just before the fault. Even though this method has inevitable error, it can show more precise fault allocation. The suggested method is applied to a typical transmission system with two power sources in both ends to verify its effectiveness.

  • PDF

A Study on the Development of GUI Software using MATLAB (MATLAB을 이용한 GUI 소프트웨어 개발에 관한 연구)

  • Kim, B.C.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.449-451
    • /
    • 2000
  • Arcing fault on overhead lines can be detected by amplitude of the arc voltage using numerical algorithm. In the case of transient fault, the arc voltage has any high value. In the case of permanent fault, the arc voltage is near zero. Thus, fault distance estimation should be performed by digital distance relay algorithm[3]. The purpose of this study is to build a structure for modeling of arcing fault detection and fault distance estimation algorithm using Matlab programming. Additionally, this algorithm has been designed in Graphical User Interface(GHI). So, this method using GUI interface of Matlab can reduce the number of simulation steps in modeling the distance relay.

  • PDF

Comparison of Fault Current Reduction Effects by the SFCL Introduction Locations

  • Kim Jong Yul;Lee Seung Ryul;Yoon Jae Young
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.16-20
    • /
    • 2005
  • As power systems grow more complex and power demands increase, the fault current tends to gradually increase. In the near future, the fault current will exceed a circuit breaker rating for some substations, which is an especially important issue in the Seoul metropolitan area because of its highly meshed configuration. Currently, the Korean power system is regulated by changing the 154kV system configuration from a loop connection to a radial system, by splitting the bus where load balance can be achieved, and by upgrading the circuit breaker rating. A development project applying 154kV Superconducting Fault Current Limiter (SFCL) to 154kV transmission systems is proceeding with implementation slated for after 2010. In this paper, SFCL is applied to reduce the fault current in power systems according to two different application schemes and their technical impacts are evaluated. The results indicate that both application schemes can regulate the fault current under the rating of circuit breaker, however, applying SFCL to the bus-tie location is much more appropriate from an economic view point.

Strain Analysis of Longitudinal Reinforcing Steels of RC Bridge Piers Under Shaking Test (진동대 실험에 의한 RC교각의 주철근 변형률 분석)

  • Hong, Hyun-Ki;Yang, Dong-Wook;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.93-96
    • /
    • 2008
  • The near fault ground motion(NFGM) is characterized by a single long period velocity pulse of large magnitude. NFGM's have been observed in recent strong earthquakes, Turkey Izmit (1999), Japan Kobe(1995), Northridge(1994), etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the far fault ground motion(FFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this study is to investigate and analyze the effect of near-fault ground motions on RC bridge piers without lap-spliced longitudinal reinforcing steels. The seismic performance of two RC bridge piers under near-fault ground motions was investigated on the shake table. In addition, Two of four identical RC bridge piers were tested under a quasi-static load, and the others were under a pseudo-dynamic load. The respectively two RC bridge pier is comparatively subjected to Pseudo-dynamic loadings and Quasi-Static loadings. This paper indicated that more gives bigger ultimate strain of longitudinal steels to be fractured at bigger PGA motion.

  • PDF

Near-surface geophysical studies in the Ulsan Fault Zone of Korea (한국 울산단층대에서의 천부지구물리 연구)

  • Kim, Ki-Young;Kim, Dong-Hoon;Lee, So-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.78-84
    • /
    • 2008
  • Recent earthquakes near nuclear power plants in Korea have triggered public concerns about possible seismicity of the Ulsan Fault Zone in the south-eastern part of the Korean peninsula. To reveal subsurface structures of this fault zone, we conducted high-resolution seismic refraction and reflection surveys, and closely spaced gravity measurements in the Dongchon River valley north of Ulsan, Korea. Here alluvium covers the north-south trending fault zone in a 1-km wide valley. Both source points and receivers were spaced at 5-m intervals for the 24-channel seismic refraction and reflection methods, along two profiles of 835 m and 415 m length. Gravity data were also measured along these profiles at 131 stations using a 10-m interval. Synergetic interpretation of seismic refraction, high-resolution seismic reflection, and gravity surveys across the valley indicates that the Ulsan Fault Zone was formed by apparent north-south strike-slip motions during the Cretaceous, and that some faults may have been reactivated by east-west compressional or transpressional stresses during the Tertiary or Quaternary.

Serial Communication-Based Fault Diagnosis of a BLDC Motor Using Bayes Classifier

  • Suh, Suhk-Hoon;Woo, Kwang-Joon
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.3
    • /
    • pp.308-314
    • /
    • 2003
  • This paper presents a serial communication based fault diagnosis scheme for a brushless DC (BLDC) motor using parameter estimation and Bayes classifier. The presented scheme consists of a smart network board, and a fault detection and isolation (FDI) master. The smart network board is installed near the BLDC motor drive system to acquire motor data and transmit motor data to the FDI-master via serial communication channel. The FDI-master estimates BLDC motor resistance to detect symptom of faults, and assign symptom to fault type using Bayes classifier. In this scheme, since communication time delay has a serious effect on performance, periodic and fixed communication protocol is designed. Hence, the delay time is priory known. By experiment result, presented scheme was verified.

Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju (전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조)

  • 손호응
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF