• 제목/요약/키워드: near surface mounted (NSM)

검색결과 46건 처리시간 0.018초

Experimental investigation on optimal shear strengthening of RC beams using NSM GFRP bars

  • Ramezanpour, M.;Morshed, R.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.45-52
    • /
    • 2018
  • Several techniques have been developed for shear strengthening of reinforced concrete (RC) members by using fiber reinforced polymer (FRP) composites. However, debonding of FRP retrofits from concrete substrate still deemed as a challenging concern in their application which needs to be scrutinized in details. As a result, this paper reports on the results of an experimental investigation on shear strengthening of RC beams using near surface mounted (NSM) FRP reinforcing bars. The main objective of the experimentation was increasing the efficiency of shear retrofits by precluding/postponing the premature debonding failure. The experimental program was comprised of six shear deficient RC beams. The test parameters include the FRP rebar spacing, inclination angle, and groove shape. Also, an innovative modification was introduced to the conventional NSM technique and its efficiency was evaluated by experimental observation and measurement. The results testified the efficiency of glass FRP (GFRP) rebars in increasing the shear strength of the test specimens retrofitted using conventional NSM technique. However, debonding of FRP bars impeded exploiting all retrofitting advantages and induced a premature shear failure. On the contrary, application of the proposed modified NSM (MNSM) technique was not only capable of preventing the premature debonding of FRP bars, but also could replace the failure mode of specimen from the brittle shear to a ductile flexural failure which is more desirable.

Behavior and modeling of RC beams strengthened with NSM-steel technique

  • Md. Akter Hosen;Khalid Ahmed Al Kaaf;A.B.M. Saiful Islam;Mohd Zamin Jumaat;Zaheer Abbas Kazmi
    • Structural Engineering and Mechanics
    • /
    • 제88권1호
    • /
    • pp.67-81
    • /
    • 2023
  • The reinforced concrete (RC) structures might need strengthening or upgradation due to adverse environmental conditions, design defects, modification requirements, and to prolong the expected lifespan. The RC beams have been efficiently strengthened using the near surface mounted (NSM) approach over the externally bonded reinforcing (EBR) system. In this study, the performance of RC beam elements strengthened with NSM-steel rebars was investigated using an experimental program and nonlinear finite element modeling (FEM). Nine medium-sized, rectangular cross-section RC beams total in number made up for the experimental evaluation. The beams strengthened with varying percentages of NSM reinforcement, and the number of grooves was assessed in four-point bending experiments up to failure. Based on the experimental evaluation, the load-displacement response, crack features, and failure modes of the strengthened beams were recorded and considered. According to the experimental findings, NSM steel greatly improved the flexural strength (up to about 84%) and stiffness of RC beams. The flexural response of the tested beams was simulated using a 3D non-linear finite element (FE) model. The findings of the experiments and the numerical analysis showed good agreement. The effect of the NSM groove and reinforcement on the structural response was then assessed parametrically.

콘크리트내 표면매립보강된 FRP의 내화단열방법과 연단거리에 따른 온도변화 (Temperature Variation Corresponding to the Protection Method and Edge Distance in Near-Surface-Mounted FRP in Concrete with Fire Protection)

  • 임종욱;서수연
    • 대한건축학회논문집:구조계
    • /
    • 제35권11호
    • /
    • pp.137-146
    • /
    • 2019
  • Recently, the Near-Surface-Mounting method using Fiber reinforced polymer (FRP) has been developed and applied to the reinforcement of many concrete structural members. However, as a part of the fire resistance design, there is a lack of research related to fire insulation for the areas reinforced with FRP. In case of NSM reinforcement, there is a difference in the transferred temperature from the external surface to the groove corresponding to the location of the groove where the FRP is embedded, and the effect of this should be reflected in the fireproof insulation design. Therefore, in this study, after forming grooves for surface embedding in concrete blocks, fireproof insulation reinforcement was performed using Calcium Silicate (CS) fireproof board and an experiment to evaluate the temperature transfer was performed. By observing the temperature at these groove positions, the reduction of temperature transfer according to fireproof insulation detail was studied. As a result, when the NSM-FRP is properly fire-insulated using the CS-based fireproof board, the epoxy inside the groove does not reach its glass transition temperature until the external temperature reaches $800^{\circ}C$.

콘크리트 내에 표면매입 보강된 FRP 판의 부착강도 (Bond Strength of Near Surface-Mounted FRP Plate in RC Member)

  • 서수연
    • 콘크리트학회논문집
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2012
  • 이 연구에서는 FRP 부재를 이용한 표면매입 보강에서, FRP의 부착강도를 평가하기 위하여 총 78개의 기존실험 결과를 분석하고, 기존 연구자들에 의해 제안된 식들을 평가하였다. 그 결과 FRP부재의 형상계수(폭-두께비)와 강성을 반영한 Seracino의 식이 부착내력을 가장 근사하게 예측하는 것으로 나타났다. 그러나 Seracino의 식은 실험 결과를 다소 과소평가하는 양상을 보이고 특히 부착길이가 작을수록 그 경향이 두드러진 것으로 나타났다. 이는 부착길이 증가에 따른 영향이 Seracino의 식에는 전혀 반영되어있지 않기 때문으로 볼 수 있다. 기존 실험 결과의 분석을 통하여 부착길이와 강도와의 상관관계를 찾고 또한 여러 개의 FRP부재를 인접하여 배치시 발생하는 무리효과를 고려하여 Seracino 식을 수정 제안하였다. 이 제시된 식을 이용하여 기존 실험체에 대한 내력을 계산하고 평가한 결과, 제안된 식으로서 표면매입 보강된 FRP의 부착강도를 매우 근사하게 예측할 수 있는 것으로 나타났다.

콘크리트에 표면매입 보강된 FRP판의 매입간격과 길이에 따른 부착강도 (Bond Strength of Near Surface-Mounted FRP Plate in Concrete Corresponding to Space and Bond Length)

  • 서수연;김민식
    • 콘크리트학회논문집
    • /
    • 제25권1호
    • /
    • pp.37-43
    • /
    • 2013
  • 최근 FRP 판을 이용한 표면매입 보강공법에서 FRP와 콘크리트 사이의 계면파괴를 연구하기 위한 실험 및 이론적인 연구가 국내외에서 수행되고 있다. 그 결과 보강재의 형상과 콘크리트 강도 그리고 부착길이 등에 대한 일련의 연구가 수행되었지만, 보강재의 부착길이에 따른 각 보강재의 적정 간격, 그리고 무리효과 등과 같은 영향인자들에 대한 연구 필요성이 제기되고 있다. 이에 따라 이 연구에서는 부착길이와 보강재인 FRP 판의 보강간격을 변수로 부착실험을 실시하고 그에 따른 부착성능의 변화를 연구하고자 한다. 또한 표면매입 보강된 FRP 판의 계면파괴시 강도를 산정하기 위한 기존 제안식과의 비교를 통하여 그 적용성을 평가하고자 한다. 연구 결과, 매입된 FRP의 간격이 넓어질수록 FRP판의 인장파단과 함께 내력이 증가하는 양상을 보이는 반면에 FRP판의 간격이 좁을수록 콘크리트 할렬파괴가 지배하는 것으로 나타났다. 기존 제안식을 이용하여 실험 결과를 비교한 결과, FRP의 부착길이와 무리효과를 고려한 기존 제안식을 사용하여 표면매입 보강된 FRP의 부착강도를 적절히 예측할 수 있는 것으로 나타났다.

채널형 FRP빔으로 보강된 RC보의 전단거동에 관한 실험적 연구 (Experimental Study for Shear Behavior of RC Beam Strengthened with Channel-type FRP Beam)

  • 홍기남
    • 한국안전학회지
    • /
    • 제24권3호
    • /
    • pp.39-46
    • /
    • 2009
  • A recent and promising method for shear strengthening of reinforced concrete(RC) members is the use of near surface mounted(NSM) fiber reinforced polymer(FRP) reinforcement. In the NSM method, the reinforcement is embedded in grooves cut onto the surface of the member to be strengthened and filled with an appropriate binding agent such as epoxy paste or cement grout. This paper illustrates a research program on shear strengthening of RC beams with NSM channel-type FRP beams which is developed in this study. The objective of this study is to clarify the role of channel-type FRP beam embedded to the beam web for shear strengthening of reinforced concrete beams. Included in the study are effectiveness in terms of spacing and angle of channel-type FRP beams, strengthening method, and shear span ratio. the study also aims to understand the additional shear capacity due to glass fiber reinforced polymer beams and carbon reinforced polymer beams. And anther objective is to study the failure modes, shear strengthening effect on ultimate force and load deflection behavior of RC beams embedded with channel-type FRP beams on the shear region of the beams.

FRP 보강근을 이용한 표면매립 및 단면확대공법의 실험적 성능평가 (Experimental Evaluation on Strengthening of NSM and! Section Increment with FRP Rebars)

  • 정상모;이차돈;원종필;황윤국;김정호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.549-554
    • /
    • 2003
  • In order to overcome the brittle failure of strengthening with FRP-rebars inherent to their brittle properties, two approaches have been attempted. One is to improve the properties like ductile Hybrid FRP Rods, and the other is to develop a ductile strengthening with partially unbonded FRP rebars. Experiments on real size specimen were performed to evaluate the performance of NSM (Near Surface Mounted Strengthening) and SIM (Section Increment Methods) with FRP rebars. This paper discusses the results of the tests on 8 slab specimen in terms of flexural resistance, ductility, and fatigue. They show that NSM or S1M with FRP rebars are very effective measures to strengthen existing RC structures. Above all, strengthening with partially unbonded ductile Hybrid FRP Rods shows sufficient ductility similar to that of properly designed RC structures.

  • PDF

NSM 보강 RC보의 부착파괴 제한에 관한 해석적 연구 (An Analytical Study on Limits of Debonding Failure for RC Beams strengthened with NSM Reinforcements)

  • 정우태;박종섭;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.153-156
    • /
    • 2006
  • This paper presents an analytical results on limits of debonding failure for RC beams strengthened with near-surface mounted(NSM) CFRP strips. An analytical model was derived to predict the failure mode and the maximum load. An analytical model has two assumptions. The first is that the debonding failure occurs at the epoxy-concrete interfaces. The second is that the debonding failure occurs at the end of the FRP reinforcement due to concentration of shear stress. Results of the comparison of existing test data and analytical model data have predicted the failure mode and the maximum load well. Also, this paper proposed limits of debonding failure to prevent the debonding using the strengthening area and the groove depth.

  • PDF

Behavior of RC beams strengthened with NSM CFRP strips under flexural repeated loading

  • Fathuldeen, Saja Waleed;Qissab, Musab Aied
    • Structural Engineering and Mechanics
    • /
    • 제70권1호
    • /
    • pp.67-80
    • /
    • 2019
  • Strengthening with near surface mounted carbon fibre reinforced polymers (NSM-CFRP) is a strengthening technique that have been used for several decades to increase the load carrying capacity of reinforced concrete members. In Iraq, many concrete buildings and bridges were subjected to a wide range of damage as a result of the last war and many other events. Accordingly, there is a progressive increase in the strengthening of concrete structures, bridges in particular, by using CFRP strengthening techniques. Near-surface mounted carbon fibre polymer has been recently proved as a powerful strengthening technique in which the CFRP strips are sufficiently protected against external environmental conditions especially the high-temperature rates in Iraq. However, this technique has not been examined yet under repeated loading conditions such as traffic loads on bridge girders. The main objective of this research was to investigate the effectiveness of NSM-CFRP strips in reinforced concrete beams under repeated loads. Different parameters such as the number of strips, groove size, and two types of bonding materials (epoxy resin and cement-based adhesive) were considered. Fifteen NSM-CFRP strengthened beams were tested under concentrated monotonic and repeated loadings. Three beams were non-strengthened as reference specimens while the remaining were strengthened with NSM-CFRP strips and divided into three groups. Each group comprises two beams tested under monotonic loads and used as control for those tested under repeated loads in the same group. The experimental results are discussed in terms of load-deflection behavior up to failure, ductility factor, cumulative energy absorption, number of cycles to failure, and the mode of failure. The test results proved that strengthening with NSM-CFRP strips increased both the flexural strength and stiffness of the tested beams. An increase in load carrying capacity was obtained in a range of (1.47 to 4.49) times that for the non-strengthened specimens. Also, the increase in total area of CFRPs showed a slight increase in flexural capacity of (1.02) times the value of the control strengthened one tested under repeated loading. Increasing the total area of CFRP strips resulted in a reduction in ductility factor reached to (0.71) while the cumulative energy absorption increased by (1.22) times the values of the strengthened reference specimens tested under repeated loading. Moreover, the replacement of epoxy resin with cement-based adhesive as a bonding material exhibited higher ductility than specimen with epoxy resin tested under monotonic and repeated loading.

3-D finite element modelling of prestressed hollow-core slabs strengthened with near surface mounted CFRP strips

  • Mahmoud, Karam;Anand, Puneet;El-Salakawy, Ehab
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.607-622
    • /
    • 2018
  • A non-linear finite element model (FEM) was constructed using a three-dimensional software (ATENA-3D) to investigate the effect of strengthening on the behavior of prestressed hollow-core (PHC) slabs with or without openings. The slabs were strengthened using near surface mounted (NSM)-carbon fiber reinforced polymer (CFRP) strips. The constructed model was validated against experimental results that were previously reported by the authors. The validated FEM was then used to conduct an extensive parametric study to examine the influence of prestressing reinforcement ratio, compressive strength of concrete and strengthening reinforcement ratio on the behavior of such slabs. The FEM results showed good agreement with the experimental results where it captured the cracking, yielding, and ultimate loads as well as the mid-span deflection with a reasonable accuracy. Also, an overall enhancement in the structural performance of these slabs was achieved with an increase in prestressing reinforcement ratio, compressive strength of concrete, external reinforcement ratio. The presence of openings with different dimensions along the flexural or shear spans reduced significantly the capacity of the PHC slabs. However, strengthening these slabs with 2 and 4 (64 and $128mm^2$ that represent reinforcement ratios of 0.046 and 0.092%) CFRP strips was successful in restoring the original strength of the slab and enhancing post-cracking stiffness and load carrying capacity.