• Title/Summary/Keyword: natural venting

Search Result 11, Processing Time 0.026 seconds

A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent (수직 배연구의 자연배연 성능에 관한 수치해석연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • In this study, the effects of vent location, outside temperature, wind velocity and fire size on the performance of natural venting of the vertical vent designed according to NFPA 204 standard and fire characteristics were numerically investigated using CFAST. In cases of the Vent located on most upper wall, lower outside temperature and lower wind velocity, vents met the performance criteria of venting. The larger fire size becomes, the more mass flow rate through a vent becomes, but the lower interface height of smoke layer becomes, so that vent didn't meet the performance criteria of venting. It should be noted that a natural vertical vent be designed considering maximum outside temperature and maximum wind velocity and developing a design fire accurately in order to meet the performance criteria of venting.

Natural gas hydrate occurrence and detection in the Sea of Okhotsk

  • Jin Young-Keun;CHAOS Scientific Party CHAOS Scientific Party
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.47-49
    • /
    • 2006
  • The Sea of Okhotsk is the unique area providing the highest methane production rate of the northern hemisphere. The area of focused fluid venting offshore the NE Sakhalin continental slope was investigated during the CHAOS (Hydro-Carbon Hydrate Accumulations in the Okhotsk Sea) expeditions onboard of RV "Akademik Lavrentyev" In 2003, 2005 and 2006. The International Research Project CHAOS (Russia-Korea-Japan) aimed at the study of gas hydrate formation processes associated with the fluid venting in the Sea of Okhotsk. Several new gas hydrate accumulations were discovered during the cruise. Hydrate-associated structures have been named as KOPRI, VNIIOKeangeologia, POI and KIT (the names of cruise participant institutes) Some of hydrate-bearing cores contain big amount of gas hydrates: massive gas hydrate layers (up to 35cm thick) were recovered. The shallowest submarine gas hydrate accumulations in the world (at the depth less then 400m) were discovered during the cruise.

  • PDF

A Study on the Effectiveness to the Life Safety by Enlarging Smoke Vent Size and/or Sprinklered System (배연창 크기와 스프링클러 작동이 인명안전에 미치는 영향 연구)

  • Kim, Hak-Joong;Park, Yong-Hwan;Lim, Choe-Hyun;Kim, Bum-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • Recently, evacuation safety of a resident of building become the major concern, because building has been higher and more complicated. Buildings in Korea should install the natural smoke venting or mechanical smoke exhaust equipment according to the building law. The smoke control is the most important to guarantee the evacuation safety. This study evaluate the influence to the height and temperature of smoke layer by enlarging smoke vent size and operating sprinkler system using CFAST (Version 6). Smoke venting size is larger, the effect to height and temperature of smoke layer is increased in below 5 MW fire. But, the correlation of these is decreased in above 10 MW fire. The case that opened smoke vent and sprinklered are applied, life safety criteria are satisfied regardless of fire size. After design the fire scenario according to the service and size of building. Install the smoke vent suitable for the fire size and verify that by experiment or simulation.

A Study on the Comparison of Natural Ventilation Standards for Domestic and Foreign Logistics Warehouses (국내외 물류창고의 자연배연기준 비교에 관한 연구)

  • Kim, Yun-Seong;Choi, Yun-Ju;Huh, Ye-Rim;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.67-68
    • /
    • 2022
  • Foreign countries stipulate that ventilation and smoke control facilities are installed in logistics warehouses. On the other hand, in Korea, the design guidelines and standards of ventilation and smoke control facilities for logistics warehouses are not clear even in the situation where the number of human casualties caused by smoke has increased until recently. Accordingly, the smoke descent time according to the vent was calculated. As a result, when there was no vent, the smoke descent time was 369s. On the other hand, when the vent was installed, smoke did not fall because the amount of smoke was greater than the amount of smoke generated.

  • PDF

Hydrocarbons in shallow sediments of the western Ulleung Basin (서부 울릉분지 천부 퇴적층의 탄화수소)

  • Ryu, Byong-Jae;Kim, Ji-Hoon;Lee, Young-Joo;Kim, Il-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.597-599
    • /
    • 2007
  • Studies on the hydrocarbons in shallow sediments of the East Sea of Korea have been carried out by the Korea Institute of Geoscience and Mineral Resources (KIGAM) since 2000. 4946 L-km of 2D multichannel reflection seismic data, 3250 L-km of high-resolution Chirp profiles and 16 selected piston cores were analyzed to determine the presence of hydrocarbons in shallow sediments of the western deep-water Ulleung Basin. The seismic data show a number of blanking zones that probably reflect widespread fluid and gas venting. The blanking zones are often associated with velocity pull-up structures. These upwelling structures are interpreted to be the result of high-velocity natural gas hydrate. There are also several bottom-simulating reflectors that are associated with free gas and probably overlying gas hydrate. Numerous pockmarks were also observed in the Chirp profiles. They are seafloor depressions caused by the removal of near-seafloor soft sediments by escaping of fluid and gas. In piston cores, cracks generally oriented parallel to bedding suggest significant gas content some of which may have been contained in gas hydrate in situ.

  • PDF

A Study on Effective Removal Method of Odorant Smell in Natural Gas using Sodium Hypochlorite (차아염소산나트륨을 이용한 천연가스 부취냄새 효과적 탈취방법 연구)

  • Lim, Hyung-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.154-159
    • /
    • 2018
  • Intentional releases occur frequently during maintenance in gas supplying companies, which may result in unpleasant odors, and the possible mistaken belief of a gas accident. Therefore, this study developed a chemical process for effective odorant removal in natural gas using an active chemical that is released intentionally during maintenance and inspection. To develop an effective treatment process for removing the odorant from released natural gas, the effluent concentrations of the odorant in the released gas were measured after a chemical oxidation reaction with a sodium hypochlorite solution in a compact gas scrubbing equipment newly devised in this study. The device was based on a mixed gas vent after the solution inject odorant in the gas through the energy of the venting gas. The cascade combination of a venturi pipe and mixing chamber was developed to remove the odorant effectively from the purposely-released natural gas using an oxidative reaction between the mercaptan compounds (odorant) and the sodium hypochlorite solution. On the other hand, the developed method could be applied limitedly to a relatively small gas release from a low-pressure source. Further studies will be needed to apply the developed process to a large-scale gas release from a high-pressure source.

Study on Adiabatic Performance of LNG Storage Tank for Vehicles (차량용 LNG연료용기의 단열성능에 관한 연구)

  • Han, Jeong-Ok;Lee, Young-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • Natural gas vehicles are being applied to city buses for improving air quality in metropolitan and have proved the effective way to reduce the pollutant emissions. Liquified Natural Gas(LNG) has also attempted a vehicle fuel in order to raise the fuel storage density that is a disadvantage of Compressed Natural Gas(CNG). This paper described insulation characteristic of a LNG storage tank. From the results, adiabatic coefficient of a tested tank was around $40J/h{\cdot}^{\circ}C{\cdot}m^2$ and it was the lower level than gas safety regulation limit. Two experimental methods were adopted to justify the evaluation results and they were revealed that the results were very similar to each other. Also, through testing relief valve operation characteristic it was investigated venting amount of boiled off gas.

  • PDF

Gas hydrate-bearing venting strucutres in the Sea of Okhotsk (오호츠크해의 가스하이드레이트 함유 가스분출구조)

  • Jin, Young-Keun;Chung, Kyoung-Ho;Party, Chaos Scientific
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.501-503
    • /
    • 2007
  • 오호츠크해 사할린 북동 해저사면지역은 세계적인 가스수화물 산출지역으로 알려져있다. 이미 2005년 탐사에서 50 cm 두께의 순수 가스수화물 시료를 해저면에서 채취한 지역이다. 2006년 탐사에서는 다양한 주파수대역의 고해상도 지구불리장비를 사용하여 탐사를 실시하였다. Side-scan Sonal와 3.5 kHz SBP 탐사, 수중음향 탐사를 통해 대규모 하도구조가 가스수화물지역의 북쪽 경계를 형성하고 있음을 밝혔다. 가스수화물의 BSR은 수심에 얕아짐에 따라 계속해서 심도가 감소하여 수심 약 300 m에서 해저면에 다다름. 이는 연구지역에서의 가스수화물 안정대의 상부경계가 약 300 m임을 시사한다 가스수화물 분출구조들은 약 1000m 수심을 경계로 천부에 분포하고, 해저면에는 원형의 가스분출구조들이 특징적으로 나타난다. 반면에 1000 m 수심보다 깊은 지역에서는 mud-dirpir의 상승구조로 판단되는 상승구조들이 해저면에 굴곡지형을 형성하고 있다. 해수중으로 분출하는 가스기둥들은 수심 111.2 m에서 1226.4 m 지점까지 다양한 수심에서 분포하며, 상승높이는 최대 750 m에 이르며, 약 150 m 수심까지 도달한다. 이는 해저에서 분출되는 메탄가스가 해수에 흡수되지 않고 해수면까지 이동하여 대기중으로 발출될 수 있음을 시사한다.

  • PDF

Provenance of Sediments and Evidence of Hydrothermal Venting Adjacent to the Fonualei Rift and Spreading Center, Lau Basin, Southwest Pacific (남서태평양 라우분지 푸누아레이 열곡확장대 인근 퇴적물의 기원과 열수 분출의 증거)

  • Kim, Mun Gi;Hyeong, Kiseong;Seo, Inah;Yoo, Chan Min
    • Ocean and Polar Research
    • /
    • v.42 no.1
    • /
    • pp.33-47
    • /
    • 2020
  • The bulk and partition geochemistry was studied in two sediment cores collected from the axial valley of the north-central Fonualei Rift and Spreading Center (FRSC), Lau back-arc Basin, southwest Pacific. The sediments consist of mostly volcanic ash, although minor amounts of biogenic and other components were present in some intervals. The major element composition of bulk sediments recalculated to a carbonate-free basis was in good agreement with the magma compositions of the adjacent Tofua Arc and the FRSC, with only significant difference in Mn content. The enrichment of Mn and other associated elements (e.g. Cu, Co, Ni, and P) is attributed to hydrothermal input to the sediments, as evidenced by their significant partitioning in the non-detrital phases according to the partition geochemistry. Hydrogenetic and diagenetic inputs were assessed to be relatively insignificant. Estimated hydrothermal Mn fluxes during the Holocene ranged between 5.0 and 37.1 mg cm-2 kyr-1, with the higher values in younger sediments, suggesting enhanced hydrothermal activity. The hydrothermal Mn fluxes comparable to or higher than those reported from other spreading centers with strong hydrothermal activities may indicate the presence of unknown hydrothermal vent sites and/or topographic restriction on the dispersal of hydrothermal plumes in the northern part of the FRSC.

MANAGING A PROLONGED STATION BLACKOUT CONDITION IN AHWR BY PASSIVE MEANS

  • Kumar, Mukesh;Nayak, A.K.;Jain, V;Vijayan, P.K.;Vaze, K.K.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.605-612
    • /
    • 2013
  • Removal of decay heat from an operating reactor during a prolonged station blackout condition is a big concern for reactor designers, especially after the recent Fukushima accident. In the case of a prolonged station blackout condition, heat removal is possible only by passive means since no pumps or active systems are available. Keeping this in mind, the AHWR has been designed with many passive safety features. One of them is a passive means of removing decay heat with the help of Isolation Condensers (ICs) which are submerged in a big water pool called the Gravity Driven Water Pool (GDWP). The ICs have many tubes in which the steam, generated by the reactor core due to the decay heat, flows and condenses by rejecting the heat into the water pool. After condensation, the condensate falls back into the steam drum of the reactor. The GDWP tank holds a large amount of water, about 8000 $m^3$, which is located at a higher elevation than the steam drum of the reactor in order to promote natural circulation. Due to the recent Fukushima type accidents, it has been a concern to understand and evaluate the capability of the ICs to remove decay heat for a prolonged period without escalating fuel sheath temperature. In view of this, an analysis has been performed for decay heat removal characteristics over several days of an AHWR by ICs. The computer code RELAP5/MOD3.2 was used for this purpose. Results indicate that the ICs can remove the decay heat for more than 10 days without causing any bulk boiling in the GDWP. After that, decay heat can be removed for more than 40 days by boiling off the pool inventory. The pressure inside the containment does not exceed the design pressure even after 10 days by condensation of steam generated from the GDWP on the walls of containment and on the Passive Containment Cooling System (PCCS) tubes. If venting is carried out after this period, the decay heat can be removed for more than 50 days without exceeding the design limits.