MANAGING A PROLONGED STATION BLACKOUT CONDITION IN AHWR BY PASSIVE MEANS |
Kumar, Mukesh
(Reactor Engineering Division Reactor Design and Development Group Bhabha Atomic Research Centre)
Nayak, A.K. (Reactor Engineering Division Reactor Design and Development Group Bhabha Atomic Research Centre) Jain, V (Reactor Engineering Division Reactor Design and Development Group Bhabha Atomic Research Centre) Vijayan, P.K. (Reactor Engineering Division Reactor Design and Development Group Bhabha Atomic Research Centre) Vaze, K.K. (Reactor Engineering Division Reactor Design and Development Group Bhabha Atomic Research Centre) |
1 | D. Hinds and C. Maslak, "Next-generation nuclear energy: The ESBWR", Nuclear News, 2006. |
2 | W.E. Cummins, M.M. Corletti, T.L. Schulz, "Westinghouse AP1000 Advanced Passive Plant", Proceedings of ICAPP '03, Cordoba, Spain, May 4-7, 2003. |
3 | Y. Mizuno, H. Ninokata and D. J. Finnicum, "Risk-informed design of IRIS using a level-1 probabilistic risk assessment from its conceptual design phase", Reliability Engineering and System Safety, 87, 201-209, 2005. DOI ScienceOn |
4 | P.E. Juhn, J. Kupitz, J. Cleveland, B. Cho and R.B. Lyon, "IAEA activities on passive safety systems and overview of international development", Nucl. Eng. Des., 201, 41-59, 2000. DOI ScienceOn |
5 | R.K. Sinha and A. Kakokar, "Design and development of the AHWR-the Indian thorium fuelled innovative nuclear reactor", Nucl. Engg. and Des., 236, 683-700, 2006. DOI ScienceOn |
6 | Amit Mangal, Vikas Jain, A.K. Nayak, "Capability of the RELAP5 code to simulate natural circulation behavior in test facilities" Progress in Nuclear Energy, Volume 61, 1-16, 2012. DOI ScienceOn |