• 제목/요약/키워드: natural evaporation

검색결과 150건 처리시간 0.021초

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

딥워터 호라이즌호 유출유 수지분석 모델의 국내 적용성 검토 (A review of Deepwater Horizon Oil Budget Calculator for its Application to Korea)

  • 김충기;오정환;강성길
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제19권4호
    • /
    • pp.322-331
    • /
    • 2016
  • 연안 및 해양에 유출된 기름의 자연적 또는 인위적 제거 경로와 양을 파악하고 방제활동이 필요한 잔류기름 양을 산정하는 것을 유출유 수지분석이라 한다. 2010년 멕시코만 딥워터 호라이즌호 사고 시 개발된 유출유 수지분석 모델은 현장 방제기술 분석 수단의 하나로서 미국 국가사고지휘본부에 방제전략 수립를 위한 핵심적인 정보를 제공하였고 방제활동의 언론 및 대국민 홍보 등에 성공적으로 활용되었다. 본 연구에서는 유출유 수지분석 기법의 이론적 내용을 분석하고 향후 국내 적용 가능성을 검토하였다. 국내외의 재난적 해양오염사고들의 유출유 수지분석 결과를 비교해보면, 유회수기를 활용한 기계적 수거로 유출량 대비 3~8%, 소각 1~5%, 유처리제에 의한 화학적 분산으로 4.8~16%의 기름이 제거되었고, 자연적 풍화작용(증발, 용해, 자연분산 등)에 의해서 37~56%가 제거된 것으로 분석되었다. 이는 유회수기와 함께 소각 및 화학적 분산이 효과적인 해상방제 기술로 적용될 수 있으며, 자연적인 풍화작용 또한 유출유 제거에 효과적임을 보여준다. 유출유 수지분석 모델이 국내 방제활동에 활용되기 위해서는 국내의 계절적 해양환경, 유류 및 방제장비 특성, 방제방법 등을 고려한 최적화된 매개변수 설정연구가 선행되어야 하며, 해안방제에 의한 유출유 제거량 산정 기법이 새로이 개발되어야 한다. 향후 국내 환경에 최적화된 유출유 수지분석 모델을 개발하여 방제 현장에 적용할 경우 보다 체계적이며 신뢰성 있고 일관성 있는 방제전략 수립, 방제작업 현장관리, 대국민 홍보 및 언론 보도 등에 유용하게 활용가능 할 것으로 사료된다.

공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰- (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -)

  • 최영돈;강용태;김내현;김만회;박경근;박병윤;박진철;홍희기
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

물-시멘트비 변화에 따른 경량콘크리트와 일반콘크리트의 물리적 성질 (Physical Properties of Lightweight and Normal Weight Concretes due to Water-Cement Ratio Changes)

  • 이창수;김재남;림연;마문학
    • 한국방재학회 논문집
    • /
    • 제9권4호
    • /
    • pp.11-20
    • /
    • 2009
  • 천연골재 고갈과 환경파괴문제 해결을 위한 방안과 경량콘크리트의 구조물 적용 실용화를 위해 폐기물 활용 인공경량골재를 이용하여 경량콘크리트를 제조하고, 물-결합재비에 따른 기본 물성을 평가하였다. 연구과 경량골재의 사전 흡수수 관리를 위한 방안을 제시하였으며, 굳지 않은 콘크리트의 특성은 경량골재를 사전 흡수하여 적용할 경우 물-결합재비에 관계없이 일반콘크리트와 유사한 방법으로 제어할 수 있는 것으로 나타났다. 경량콘크리트의 경화 후 단위용적질량은 물-결합재비, 건조 조건, 철근고려에 따라 1,668${\sim}$1,998 $kg/m^3$의 범위로서 일반콘크리트에 비해 14.6${\sim}$21.0% 의 감소를 나타내었다. 경량골재 사전 흡수수는 물-결합재비에 따라 상이한 증발수량을 나타내었으며, 물-결합재비가 낮을수록 노건조 증발수가 커져 내부양생수로서의 역할 가능성이 증가할 것으로 생각된다. 동일 물-시멘트비에서 경량콘크리트는 일반콘크리트에 비하여 골재의 강도차이로 인해 낮은 강도를 나타내며, 기건 양생 시 일반콘크리트의 경우 물-시멘트비 0.3은 물-시멘트비 0.4, 0.5에 비해 강도 증진 효과가 감소하지만, 경량콘크리트의 경우 물-결합재비가 낮을수록 강도 증진 효과가 증가하는 것으로 나타났다.

CO2고정화(固定化)를 위한 전기로제강(電氣爐製鋼)슬래그의 칼슘성분(成分) 침출(浸出) (The Extraction of Ca in Electric arc Furnace Slag for CO2 Sequestration)

  • 윤기병
    • 자원리싸이클링
    • /
    • 제22권1호
    • /
    • pp.64-71
    • /
    • 2013
  • 지구온난화 원인으로 지목되고 있는 $CO_2$가스를 저감시키기 위한 방안 중의 하나로 칼슘이나 마그네슘 등을 함유하는 천연규산염 광물의 탄산염화가 제안되고 있다. 전기로제강슬래그는 칼슘, 마그네슘 등 을 주성분으로 하는 규산염들로 구성되고 있어, 이 슬래그를 천연규산염 광물 대신에 탄산염화의 대상원료로 사용하면 $CO_2$가스저감은 물론 탄산칼슘과 같은 산업원료를 제조, 활용할 수 있는 가능성이 있다. 전기로제강슬래그 탄산염화에 의한 탄산칼슘 제조공정은 칼슘성분의 분리단계와 분리된 칼슘성분의 탄산염화단계로 구성된다. 슬래그 중의 칼슘성분 분리를 위한 초산침출 연구결과는 이미 보고되어 있으며 분리된 침출용액 중의 칼슘이온의 탄산염화는 고압의 $CO_2$가스 하에서도 반응속도가 매우 느린 것으로 예측되고 있다. 본 연구에서는 보다 효율적인 침출 및 탄산염화 공정의 개발을 위하여 염산수용액 침출에 의한 칼슘성분 분리에 관한 실험을 수행하였으며 그 침출결과를 초산침출 실험결과와 비교, 분석하였다. 용액 중의 $Ca^{2+}$$CO_2$가스에 의한 탄산염화 반응에 대한 열역학적 자료를 통하여 용액의 pH에 따른 $Ca^{2+}$$CaCO_3$의 phase boundary를 고찰하였다. 슬래그 중의 칼슘성분 분리를 위해서는 염산이 초산에 비하여 더욱 효율적인 침출용매이며, 염산을 침출용매로 사용 시는 침출용액 중의 미반응산의 회수 및 재순환이 유리할 것으로 기대된다.

Evaporative Stress Index (ESI)의 국내 가뭄 심도 분류 기준 제시 (Percentile Approach of Drought Severity Classification in Evaporative Stress Index for South Korea)

  • 이희진;남원호;윤동현;홍은미;김태곤;박종환;김대의
    • 한국농공학회논문집
    • /
    • 제62권2호
    • /
    • pp.63-73
    • /
    • 2020
  • Drought is considered as a devastating hazard that causes serious agricultural, ecological and socio-economic impacts worldwide. Fundamentally, the drought can be defined as temporarily different levels of inadequate precipitation, soil moisture, and water supply relative to the long-term average conditions. From no unified definition of droughts, droughts have been divided into different severity level, i.e., moderate drought, severe drought, extreme drought and exceptional drought. The drought severity classification defined the ranges for each indicator for each dryness level. Because the ranges of the various indicators often don't coincide, the final drought category tends to be based on what the majority of the indicators show and on local observations. Evaporative Stress Index (ESI), a satellite-based drought index using the ratio of potential and actual evaporation, is being used as a index of the droughts occurring rapidly in a short period of time from studies showing a more sensitive and fast response to drought compared to Standardized Precipitation Index (SPI), and Palmer Drought Severity Index (PDSI). However, ESI is difficult to provide an objective drought assessment because it does not have clear drought severity classification criteria. In this study, U.S. Drought Monitor (USDM), the standard for drought determination used in the United States, was applied to ESI, and the Percentile method was used to classify drought categories by severity. Regarding the actual 2017 drought event in South Korea, we compare the spatial distribution of drought area and understand the USDM-based ESI by comparing the results of Standardized Groundwater level Index (SGI) and drought impact information. These results demonstrated that the USDM-based ESI could be an effective tool to provide objective drought conditions to inform management decisions for drought policy.

Combined Skin Moisturization of Liposomal Serine Incorporated in Hydrogels Prepared with Carbopol ETD 2020, Rhesperse RM 100 and Hyaluronic Acid

  • Kim, Hyeongmin;Ro, Jieun;Barua, Sonia;Hwang, Deuk Sun;Na, Seon-Jeong;Lee, Ho Sung;Jeong, Ji Hoon;Woo, Seulki;Kim, Hyewon;Hong, Bomi;Yun, Gyiae;Kim, Joong-Hark;Yoon, Young-Ho;Park, Myung-Gyu;Kim, Jia;Sohn, Uy Dong;Lee, Jaehwi
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제19권6호
    • /
    • pp.543-547
    • /
    • 2015
  • We investigated the combined moisturizing effect of liposomal serine and a cosmeceutical base selected in this study. Serine is a major amino acid consisting of natural moisturizing factors and keratin, and the hydroxyl group of serine can actively interact with water molecules. Therefore, we hypothesized that serine efficiently delivered to the stratum corneum (SC) of the skin would enhance the moisturizing capability of the skin. We prepared four different cosmeceutical bases (hydrogel, oil-in-water (O/W) essence, O/W cream, and water-in-oil (W/O) cream); their moisturizing abilities were then assessed using a $Corneometer^{(R)}$. The hydrogel was selected as the optimum base for skin moisturization based on the area under the moisture content change-time curves (AUMCC) values used as a parameter for the water hold capacity of the skin. Liposomal serine prepared by a reverse-phase evaporation method was then incorporated in the hydrogel. The liposomal serine-incorporated hydrogel (serine level=1%) showed an approximately 1.62~1.77 times greater moisturizing effect on the skin than those of hydrogel, hydrogel with serine (1%), and hydrogel with blank liposome. However, the AUMCC values were not dependent on the level of serine in liposomal serine-loaded hydrogels. Together, the delivery of serine to the SC of the skin is a promising strategy for moisturizing the skin. This study is expected to be an important step in developing highly effective moisturizing cosmeceutical products.

FGR 시스템 동력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구 (A Study on Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in a Power Plant Boiler with FGR System)

  • 배명환;정광호;박성범
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.263-273
    • /
    • 2016
  • 자연순환식 압입 송풍식 수관보일러에 FGR시스템을 설치하여 보일러 부하 및 공기량 댐퍼개도를 파라미터로 해서 FGR률에 따른 성능 및 배기 배출물에 미치는 재순환 배기의 영향을 조사하였다. 본 연구의 목적은 $NO_x$ 배출물을 저감시키기 위하여 동력플랜트 보일러에 FGR시스템을 적용하는 것이다. 연소를 활성화시키기 위해 0 ~ 20%의 연소용 공기를 화염 내에 공급한다. 공기상자 상부에 설치된 2단 연소시스템의 흡입댐퍼를 $0^{\circ}{\sim}90^{\circ}$ 사이에서 레버를 조작하여 열면, 버너로 공급되는 연소용 공기가 변화된다. 증발률당의 연료소비율은 FGR률의 증가에 따라 증가 혹은 감소의 명확한 경향을 나타내지 않았고, 동일 공기량 댐퍼개도에서는 FGR률이 증가할수록, 또한, 보일러 부하가 감소할수록 $NO_x$ 배출물이 감소되었다. 매연 배출물은 전기 집진기에서 86.7%의 포집효율로 매연이 제거되었기 때문에, 보일러 부하, 공기량 댐퍼 개도 및 FGR률의 운전조건에 관계없이 극소량의 매연이 배출되었다.

LID 시설 관리를 위한 사물인터넷(IoT) 활용 복합 센싱 적용기술 개발 (Development of Composite Sensing Technology Using Internet of Things (IoT) for LID Facility Management)

  • 이승재;전민수;이정민;김이형
    • 한국습지학회지
    • /
    • 제22권4호
    • /
    • pp.312-320
    • /
    • 2020
  • 도시 환경문제 및 개발사업 환경영향 저감을 위하여 자연적 물 순환 기능을 가진 다양한 LID가 적용되고 있다. 그러나 LID 시설의 과도한 침투와 증발산은 LID 내부 토양을 건조화시켜 식물과 미생물 활동성을 떨어뜨리고 환경저감 능력을 감소시킨다. 본 연구는 LID 시설의 관리 방안을 도출하기 위하여 복합적인 센서를 적용한 실시간 측정 시스템을 개발하고자 하였다. 측정 가능한 센서와 사물인터넷(IoT) 적용 실험은 아크릴 상자에 형상화한 인공습지에서 수행되었다. 적용되는 센서는 분산형으로 설치되는 LID를 고려하여 저비용으로 구축하고자 하였으며 비교적 저렴하면서 상용화되어있는 아두이노와 라즈베리 파이를 기반으로 하였다. 그리고 LID 시설의 현재 상태와 유지관리 및 이상기후 시 영향을 분석하기 위해 복합적인 센서 측정 개발에 목표를 두었다. 센서는 풍향·풍속, 강우량, 이산화탄소, 미세먼지, 온도·습도, 산성도, 위치 정보 등을 실시간으로 측정하도록 하였다. 또한 측정된 데이터의 수집, 전송 및 결과 확인을 위하여 데이터 수집 장치, 저장 서버 프로그램 및 PC와 모바일 활용 결과 확인 프로그램을 개발하였다. 각 센서를 통해 얻은 측정값들은 Wifi 모듈을 통해 관리 서버로 전달되고 실시간으로 데이터베이스 서버에 저장된다. 본 연구에서 수행한 4개월간의 측정 결과를 분석한 결과 LID 시설에 ICT 기술 적용의 안정성과 적용 가능성을 확인하였다. 실시간으로 측정된 값은 LID 시설의 기능 평가 및 유지관리 방안 도출을 위한 빅데이터 활용이 가능한 것으로 나타났다.

양송이 버섯의 생리적 특성에 대한 감마선 조사 영향 (Effect of Ionizing Radiation of Physiological Characteristics of Fresh Mushrooms (Agaricus bisporus L.))

  • 변명우;권중호;조한옥;차보숙;강세식;김중만
    • 한국식품과학회지
    • /
    • 제21권5호
    • /
    • pp.669-675
    • /
    • 1989
  • 감마선 조사 (0, 1, 2, 3kGy)에 의한 생양송이 버섯의 저장성 연장에 관한 연구결과는 다음과 같다. $9{\pm}1^{\circ}C,\;80{\pm}7%$ RH 저장조건에서 비조사구는 저장 3일경부터 갓핌과 줄기가 크게 신장하고 노후현상을 보여 상품가치를 상실한데 반해 감마선 조사구는 자연적 숙성으로 지연으로 1kGy 조사구는 10일정도, 2-3kGy 조사구는 20일까지도 신선도를 유지하였다. 양송이의 조직은 저장기간 동안 모든 시험구에서 연화를 보였으나 감마선 조사구가 비조사구에 비해 양호하였다. 중량 변화는 골판지 상자에 양송이를 담고 polyethylene 필름으로 겉씌우기를 한 것이 골판지 단독 포장구보다 중량감소 억제효과가 매우 현저하였고, 저장 5일 이후부터는 2-3kGy 조사구가 비조사구에 비해 중량 감소율이 낮았다. 이러한 결과는 생양송이에 2-3kGy의 감마선 조사 후 $9{\pm}1^{\circ}C,\;80{\pm}7%$ RH 의 저장조건에서 숙도지연에 따른 고려할 만한 저장성 연장효과를 나타내었다.

  • PDF