• Title/Summary/Keyword: narrow channel

Search Result 358, Processing Time 0.027 seconds

A Study on the Assessment of Environment Stress in Mokpo Approaching Channel (목포항 출입항로의 환경스트레스 평가에 관한 연구)

  • KIM Chol-Seong;JONG Jae-Yong;Park Sung-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.3 s.26
    • /
    • pp.211-218
    • /
    • 2006
  • Recently, many ships such as fishing boats, cargo ships, high speed ferry boats are visiting Mokpo harbor. In particular, many marine accidents have been occurred at this area due to the narrow channel, a thick fog, the existing of the shallow waters etc. However there is no suitable ships' routeing system which takes account of today's traffic situations in this area. This study aims at the settling of hazardous factors to mitigate the danger to vessels in Mokpo harbor and to secure the safety of maritime environment.

  • PDF

Numerical Analysis on the Flow Distribution in Ondol Flue Channel (산고래 온돌연도내의 유동분포에 관한 수치해석)

  • Man Man-Ki;Lee Seung Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.264-274
    • /
    • 1983
  • Two-dimensional jet flows into a couple of confined rectangular enclosures such as an Ondol flue channel and their flow distributions were analyzed by numerical graphics : rectangular space in one enclosure is vacated and the other has 8 rectangular small posts. Both enclosures have a protruded inlet nozzle and on outlet on its center line. Steady state incompressible laminar viscous flow was assumed. The primitive forms of Navier-Stokes equations and continuity equation in a cartesian coordinate system were solved numerically by the Marker and Cell method for Reynolds numbers of 5, 10, 20, 30 and 40. From the numerical graphics it was found that the flow regions in both enclosures were devided into tow parts ; one part was the jet flow localized in a narrow center region of the enclosure and the other part was the very slow recirculating flow occupying the rest of the flow region in the enclosures. However there were a little differences in the shapes of jet flow in both enclosures for Reynolds numbers of 5 and 10 and also in the shapes of recirculating flows in both enclosures for all Reynolds number. Also it was found that waving flow appeared right before the outlet at Reynolds number of 20 and more.

  • PDF

Analysis on Protection Ratio of IBAC DAB System for Co-Channel FM Interferer (동일채널 FM 간섭원에 대한 IBAC DAB 시스템의 혼신 보호비 분석)

  • Jeong, Young-Ho;Park, So-Ra;Kim, Geon;Lee, Hyun;Lee, Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.199-210
    • /
    • 2000
  • The IBAC (In-Band Adjacent-Channel) DAB (Digital Audio Broadcasting) system is to provide multichannel CD quality audio services and multimedia data services including text and picture in FM band (88~105 MHz). As the FM band is being used by the existing analog radio broadcasting, there must he an analysis of the interference effect between IBAC DAB and analog FM signal. Therefore, the protection ratio should be evaluated to verify the system compatibility and allocate the new IBAC DAB channel in FM band. In this paper, among the three types of interferences, FM-to-DAB, DAB-to-FM and DAB-to-DAB, that can be occurred, the Protection ratio of IBAC DAB system for co-channel FM interferer is analyzed by modeling the FM interferer and considering the multipath fading channel. The simulation results show that IBAC DAB system has far better sensitivity than Eureka 147 and needs a relatively high protection ratio for co-channel FM interferer, because of its narrow bandwidth, about one third of that of Eureka 147.

  • PDF

A Study on Leaching Characteristics Change for Sediment Dredging in Yongwon Channel, Busan New Port (부산신항 용원수로에서의 퇴적물 준설에 의한 용출특성 변화 연구)

  • Choo, Min Ho;Kim, Young Do;Jeong, Weon Mu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.541-547
    • /
    • 2017
  • In Yongwon channel, its natural flow of seawater is blocked by the construction of Busan Newport including the container berth. The channel was transformed into a narrow and long one, where it is possible that ships are only allowed to pass through the north-side channel of Gyeonmado located at the point of river mouth to Songjeongcheon. So it is considered that the changes in the terrain characteristics of Yongwon channel is likely to alter the circulation of sea water, thereby changing its water quality. Contaminants are accumulated from the sediment release. In this study, before and after dredging the sediment release test was performed. As a result, after the sediment dredging is performed, the reduction rate was higher at the same point. The results show that the water quality can be improved by dredging. Each group (A~C) reduction rate of the evaluation of the reduction rate of 4.64% T-N, 18.00%, 18.59%, respectively. T-P rate of 24.75% reduction, 24.17%, 44.08%, respectively. COD reduction rate was 18.57%, 19.76%, 38.08%, respectively. These results can be used as basic data for controlling the contamination by dredging in Yongwon channel.

Influences of Vegetation Invasion on Channel Changes in the Deposition Area of Torrential Stream (계상퇴적지내의 식생침입이 유로변동에 미치는 영향)

  • Ma, Ho-Seop;Lee, Heon-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.3
    • /
    • pp.12-19
    • /
    • 2000
  • The purpose of this study is to evaluate the channel changes according to the temporal and spatial distribution of the deposition area by the vegetation invasion in Kyesung-river. The deposition area mainly occurred by landslide and debris flow from the headwater channel. And also the movement of subsequent downstream depends upon the site of deposits by a varity erosional processes. As the age of deposition area is older, it had a tendency to stable by plant invasion relatively. The vegetations grown in deposition area were very effective to estimate a historical deformation process of river-bed occurred by landslide. The vegetations around deposition area consisted of the same as tree species grown in forest area of circumference like Pinus densiflora, Styrax japonica, Quercus acutissima and Salix gracilistyla. If the torrential stream is flooding, the deposition area of 1 to 5 years can be change to the channel easily. Deposition area of 11 to 23 years had a high river-bed because it passed long time since deposited, and amount of sedimention is much more in wide than in narrow channel. It is consider that the change of channel had many influenced by the span of survial time, scale and movement frequency of deposition area after the vegetation invasion.

  • PDF

Interfacial Friction Factor in Arrested Saline Wedge (정상염수(定常塩水)쐐기에 있어서의 계면저항계수(界面低抗係數)의 평가(評價))

  • Lee, Moon Ock;Murota, Akira
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.53-62
    • /
    • 1989
  • In order to determine the form and the length of saline wedge, it is necessary to evaluate interfacial friction factor. Hetherto one dimensional two-layer flow model which assumed pressure as the hydrostatic pressure distribution has been well used to the calculation of saline wedge form, it just then stands in need of relevant interfacial friction factor. For example, in the case where we calculate back to interfacial friction factor out of saline wedge form obtained at a laboratory open channel with comparatively narrow width, it is needed to correct the side-wall effect of a channel, if generally negligible in the river. In this study, we confirmed the influence of a side-wall upon the lateral velocity distributions at laboratory channel and then examined in detail the value of interfacial friction factor in the case where it was corrected by the side-wall effect and not corrected. And then we make clear the influence of a side-wall upon the arrested saline wedge and interfacial faction factor from these results.

  • PDF

Research on Performance Analysis for the Long Distance Air-Ground Wideband Common Data Link (장거리 공중-지상 채널환경에서 대용량 데이터링크의 수신성능 분석방법 연구)

  • Ryu, Young-Jae;Ahn, Jae Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.703-715
    • /
    • 2017
  • In this paper, we analyze the channel characteristics of the long distance air-ground wideband common data link and we propose a mathematical method to analyze the effect of narrowband and wideband interference of air-ground channel on the received signal of wideband data link. In this paper, we analyze the reception performance according to the communication distance using the proposed performance analysis method, and found out that the communication distance is limited by the narrowband and wideband interference of ground reflection wave. As a result of the performance analysis of the method of controlling the receiving antenna upward, not only the narrow band but also the wideband interference is effectively reduced, so that the communication distance is increased even in the existing wideband data link not including the equalizer.

COMPARISON OF DRYOUT POWER DATA BETWEEN CANFLEX MK-V AND CANFLEX MK-IV BUNDLE STRINGS IN UNCREPT AND CREPT CHANNELS

  • JUN JI SU;LEUNG L.K.H.
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.565-574
    • /
    • 2005
  • The CANFLEX Mk-V bundle is designed to improve upon the critical heat flux (CHF) characteristics of the CANFLEX Mk-IV bundle. The main difference between these two bundles is an increase in bearing pad height of about 0.3 mm in the CANFLEX Mk-IV bundle. This change in bearing pad height leads to an increase in gap flow at the bottom of the bundle, primarily eliminating the localized narrow-gap effect that limits the CHF of the CANFLEX Mk-IV bundle. The objective of this paper is to examine the effects of bearing pad height and pressure tube creep on the sheath-temperature distribution, dryout power, and dryout location, as observed ken full-scale bundle tests, between CANFLEX Mk-IV and Mk-V bundles In uncrept and crept channels. A comparison of surface-temperature differences between the top and bottom elements of the bundles showed that increasing the bearing pad height has led to a more homogeneous enthalpy distribution in subchannels of the bundle. Initial dryout locations of the CANFLEX Mk-V bundle were mainly observed at the mid-spacer plane of either the $10^{th}$ (about $80\%$) or $11^{th}$ ($20\%$) bundle in the 12-bundle string, as compared to the mid-spacer and downstream-button planes for the CANFLEX Mk-IV bundle. Dryout power and boiling-length-average (BLA) CHF values exhibit consistent trends and little scatter with varying flow conditions for both types of CANFLEX bundles in uncrept and crept channels. An increase in pressure tube creep has led to a reduction in dryout power (about $20\%$ far the $3.3\%$ crept channel and $27\%$ for the $5.1\%$ crept channel as compared to dryout powers for the uncrept channel). Increasing the bearing pad height of the CANFLEX bundle has led to an increase in the dryout power. Overall, the dryout power of the CANFLEX Mk-V bundle is 7 to $10\%$ higher than that of the CANFLEX Mk-IV bundle at the inlet temperature range of interest (i.e., between 243 and $290^{\circ}C$).

Multi-Channel AD Converters with High-Resolution and Low-Speed (고정밀 저속 다중채널 아날로그-디지털 변환기)

  • Bae, Sung-Hwan;Lee, Chang-Ki
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.3
    • /
    • pp.165-169
    • /
    • 2008
  • Analog-to-Digital converters (ADCs) used in instrumentation and measurements often require high absolute accuracy, including excellent linearity and negligible dc offset. Incremental converters provide a solution for such measurement applications, as they retain most of the advantages of conventional ${\Delta}{\Sigma}$ converters, and yet they are capable of offset-free and accurate conversion. Most of the previous research on incremental converters was for single-channel and dc signal applications, where they can perform extremely accurate data conversion with more than 20-bit resolution. In this paper, a design technique for implementing multiplexed incremental data converters to convert narrow bandwidth ac signals is discussed. A design methodology to optimize the signal-to-quantization+thermal noise ratio of multiplexed IDC is presented. It incorporates the operation principle, topology, and digital decimation filter design. The theoretical results are verified by simulation results.

  • PDF

Studies on Debris Flows by Heavy Rainfall in Osaek Area in July 2006 (2006년 7월 집중호우로 인한 오색천 유역의 토석류 발생과 그 특성)

  • YANG, Heakun;PARK, Kyeong
    • Journal of The Geomorphological Association of Korea
    • /
    • v.15 no.2
    • /
    • pp.25-35
    • /
    • 2008
  • Typhoon Ewiniar and Bilis followed by heavy rainfall in July 2006 triggered massive slope failures and debris flows along the Osaek valley within Seoraksan National Park. Since national road 44 is constructed along the fault-line, the susceptibility of hazard in the area is very high. Debris flows in Osaekcheon are mobilized from landslides near the ridgelines and peaks when heavy rainfall elevates pore pressure and adds weight to the hillslopes, causing failure. Stream flows falling onto the existing colluvium or channel-margin deposits also trigger debris flows. Steep slopes constructed along the road and thin regolith in the slope is the main reason for the landslide in the upper stream. In middle reaches of stream, under-fit drainage utilities and narrow bridges cause the overflow, this then triggers debris flow. Overflowing and erosion in the channel margin deposits is main reasons for the debris flow. The intensities and frequencies of heavy rainfall are certain to increase, so early warning and management system for the landslide-related hazard is urgently needed.